-
LIGO operates with quantum noise below the Standard Quantum Limit
Authors:
Wenxuan Jia,
Victoria Xu,
Kevin Kuns,
Masayuki Nakano,
Lisa Barsotti,
Matthew Evans,
Nergis Mavalvala,
Rich Abbott,
Ibrahim Abouelfettouh,
Rana Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Naoki Aritomi,
Stuart Aston,
Matthew Ball,
Stefan Ballmer,
David Barker,
Beverly Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Nina Bode,
Edgard Bonilla,
Vladimir Bossilkov
, et al. (146 additional authors not shown)
Abstract:
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Stan…
▽ More
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Standard Quantum Limit (SQL). Reducing quantum noise below the SQL in gravitational-wave detectors, where photons are used to continuously measure the positions of freely falling mirrors, has been an active area of research for decades. Here we show how the LIGO A+ upgrade reduced the detectors' quantum noise below the SQL by up to 3 dB while achieving a broadband sensitivity improvement, more than two decades after this possibility was first presented.
△ Less
Submitted 22 April, 2024;
originally announced April 2024.
-
Photon Counting Interferometry to Detect Geontropic Space-Time Fluctuations with GQuEST
Authors:
Sander M. Vermeulen,
Torrey Cullen,
Daniel Grass,
Ian A. O. MacMillan,
Alexander J. Ramirez,
Jeffrey Wack,
Boris Korzh,
Vincent S. H. Lee,
Kathryn M. Zurek,
Chris Stoughton,
Lee McCuller
Abstract:
The GQuEST (Gravity from the Quantum Entanglement of Space-Time) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present an interferometer design featuring a novel photon counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this des…
▽ More
The GQuEST (Gravity from the Quantum Entanglement of Space-Time) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present an interferometer design featuring a novel photon counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this design to measure space-time fluctuations motivated by recent `geontropic' quantum gravity models. The accelerated accrual of statistical power offered by the photon counting readout enables GQuEST to detect the predicted quantum gravity phenomena within measurement times at least 100 times shorter than equivalent conventional interferometers. The GQuEST design thus enables a fast and sensitive search for signatures of quantum gravity in a laboratory-scale experiment.
△ Less
Submitted 11 April, 2024;
originally announced April 2024.
-
Single-Photon Signal Sideband Detection for High-Power Michelson Interferometers
Authors:
Lee McCuller
Abstract:
The Michelson interferometer is a cornerstone of experimental physics. Its applications range from providing first impressions of wave interference in educational settings to probing spacetime at minuscule precision scales. Interferometer precision provides a unique view of the fundamental medium of matter and energy, enabling tests for new physics as well as searches for the gravitational wave si…
▽ More
The Michelson interferometer is a cornerstone of experimental physics. Its applications range from providing first impressions of wave interference in educational settings to probing spacetime at minuscule precision scales. Interferometer precision provides a unique view of the fundamental medium of matter and energy, enabling tests for new physics as well as searches for the gravitational wave signatures of distant astrophysical events. Optical interferometers are typically operated by continuously measuring the power at their output port. Signal perturbations then create sideband fields, forming a beat-note with the fringe light that modulates that power. When operated at a nearly-dark destructive interference fringe, this readout is a form of homodyne detection, with an imprecision set by a ``standard quantum limit'' attributed to shot noise from quantum vacuum fluctuations. The sideband signal fields carry energy which can, alternatively, be directly observed as photons distinct from the source laser. Without signal energy, vacuum does not form sidebands and cannot spuriously create photon counts or shot noise. Thus, counting can offer improved statistics when searching for weak signals when classical backgrounds are below the standard quantum limit. Here, photon counting statistics are described for optical interferometry, relating the two forms of measurement and showing cases where counting greatly outperforms homodyne readout, even with squeezed state quantum enhancement. The most immediate application for photon counting is improving searches of stochastic signals, such as from quantum gravity or from new particle fields. The advantages of counting may extend to wider applications, such as gravitational wave detectors, and the concept of Fisher-information representative spectral density is introduced to motivate further study.
△ Less
Submitted 8 November, 2022;
originally announced November 2022.
-
Point Absorber Limits to Future Gravitational-Wave Detectors
Authors:
W. Jia,
H. Yamamoto,
K. Kuns,
A. Effler,
M. Evans,
P. Fritschel,
R. Abbott,
C. Adams,
R. X. Adhikari,
A. Ananyeva,
S. Appert,
K. Arai,
J. S. Areeda,
Y. Asali,
S. M. Aston,
C. Austin,
A. M. Baer,
M. Ball,
S. W. Ballmer,
S. Banagiri,
D. Barker,
L. Barsotti,
J. Bartlett,
B. K. Berger,
J. Betzwieser
, et al. (176 additional authors not shown)
Abstract:
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some hig…
▽ More
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some high-power cavity experiments, for example, the Advanced LIGO gravitational wave detector. In this Letter, we present a general approach to the point absorber effect from first principles and simulate its contribution to the increased scattering. The achievable circulating power in current and future gravitational-wave detectors is calculated statistically given different point absorber configurations. Our formulation is further confirmed experimentally in comparison with the scattered power in the arm cavity of Advanced LIGO measured by in-situ photodiodes. The understanding presented here provides an important tool in the global effort to design future gravitational wave detectors that support high optical power, and thus reduce quantum noise.
△ Less
Submitted 17 September, 2021;
originally announced September 2021.
-
LIGOs Quantum Response to Squeezed States
Authors:
L. McCuller,
S. E. Dwyer,
A. C. Green,
Haocun Yu,
L. Barsotti,
C. D. Blair,
D. D. Brown,
A. Effler,
M. Evans,
A. Fernandez-Galiana,
P. Fritschel,
V. V. Frolov,
N. Kijbunchoo,
G. L. Mansell,
F. Matichard,
N. Mavalvala,
D. E. McClelland,
T. McRae,
A. Mullavey,
D. Sigg,
B. J. J. Slagmolen,
M. Tse,
T. Vo,
R. L. Ward,
C. Whittle
, et al. (172 additional authors not shown)
Abstract:
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to furth…
▽ More
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to further expand our gravitational view of the universe. Further reducing quantum noise will require both lowering decoherence from losses as well more sophisticated manipulations to counter the quantum back-action from radiation pressure. Both tasks require fully understanding the physical interactions between squeezed light and the many components of km-scale interferometers. To this end, data from both LIGO observatories in observing run three are expressed using frequency-dependent metrics to analyze each detector's quantum response to squeezed states. The response metrics are derived and used to concisely describe physical mechanisms behind squeezing's simultaneous interaction with transverse-mode selective optical cavities and the quantum radiation pressure noise of suspended mirrors. These metrics and related analysis are broadly applicable for cavity-enhanced optomechanics experiments that incorporate external squeezing, and -- for the first time -- give physical descriptions of every feature so far observed in the quantum noise of the LIGO detectors.
△ Less
Submitted 25 May, 2021;
originally announced May 2021.
-
Point absorbers in Advanced LIGO
Authors:
Aidan F. Brooks,
Gabriele Vajente,
Hiro Yamamoto,
Rich Abbott,
Carl Adams,
Rana X. Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Joseph S. Areeda,
Yasmeen Asali,
Stuart M. Aston,
Corey Austin,
Anne M. Baer,
Matthew Ball,
Stefan W. Ballmer,
Sharan Banagiri,
David Barker,
Lisa Barsotti,
Jeffrey Bartlett,
Beverly K. Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Sebastien Biscans
, et al. (176 additional authors not shown)
Abstract:
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback contro…
▽ More
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback control system. We review the expected surface deformation from point absorbers and provide a pedagogical description of the impact on power build-up in second generation gravitational wave detectors (dual-recycled Fabry-Perot Michelson interferometers). This analysis predicts that the power-dependent reduction in interferometer performance will significantly degrade maximum stored power by up to 50% and hence, limit GW sensitivity, but suggests system wide corrections that can be implemented in current and future GW detectors. This is particularly pressing given that future GW detectors call for an order of magnitude more stored power than currently used in Advanced LIGO in Observing Run 3. We briefly review strategies to mitigate the effects of point absorbers in current and future GW wave detectors to maximize the success of these enterprises.
△ Less
Submitted 25 March, 2021; v1 submitted 14 January, 2021;
originally announced January 2021.
-
Interferometric Constraints on Spacelike Coherent Rotational Fluctuations
Authors:
Jonathan W. Richardson,
Ohkyung Kwon,
H. Richard Gustafson,
Craig Hogan,
Brittany L. Kamai,
Lee P. McCuller,
Stephan S. Meyer,
Chris Stoughton,
Raymond E. Tomlin,
Rainer Weiss
Abstract:
Precision measurements are reported of the cross-spectrum of rotationally-induced differential position displacements in a pair of colocated 39 m long, high power Michelson interferometers. One arm of each interferometer is bent $90^{\circ}$ near its midpoint to obtain sensitivity to rotations about an axis normal to the plane of the instrument. The instrument achieves quantum-limited sensing of s…
▽ More
Precision measurements are reported of the cross-spectrum of rotationally-induced differential position displacements in a pair of colocated 39 m long, high power Michelson interferometers. One arm of each interferometer is bent $90^{\circ}$ near its midpoint to obtain sensitivity to rotations about an axis normal to the plane of the instrument. The instrument achieves quantum-limited sensing of spatially-correlated signals in a broad frequency band extending beyond the 3.9 MHz inverse light travel time of the apparatus. For stationary signals with bandwidth $Δf > 10\;\mathrm{kHz}$, the sensitivity to rotation-induced strain $h$ of classical or exotic origin surpasses $\mathrm{CSD}_{δh} < t_P / 2$, where $t_P = 5.39 \times 10^{-44}\;\mathrm{s}$ is the Planck time. This measurement is used to constrain a semiclassical model of nonlocally coherent rotational degrees of freedom of spacetime, which have been conjectured to emerge in holographic quantum geometry but are not present in a classical metric.
△ Less
Submitted 19 May, 2021; v1 submitted 12 December, 2020;
originally announced December 2020.
-
Demonstration of an amplitude filter cavity at gravitational-wave frequencies
Authors:
Kentaro Komori,
Dhruva Ganapathy,
Chris Whittle,
Lee McCuller,
Lisa Barsotti,
Nergis Mavalvala,
Matthew Evans
Abstract:
Quantum vacuum fluctuations fundamentally limit the precision of optical measurements, such as those in gravitational-wave detectors. Injection of conventional squeezed vacuum can be used to reduce quantum noise in the readout quadrature, but this reduction is at the cost of increasing noise in the orthogonal quadrature. For detectors near the limits imposed by quantum radiation pressure noise (QR…
▽ More
Quantum vacuum fluctuations fundamentally limit the precision of optical measurements, such as those in gravitational-wave detectors. Injection of conventional squeezed vacuum can be used to reduce quantum noise in the readout quadrature, but this reduction is at the cost of increasing noise in the orthogonal quadrature. For detectors near the limits imposed by quantum radiation pressure noise (QRPN), both quadratures impact the measurement, and the benefits of conventional squeezing are limited. In this paper, we demonstrate the use of a critically-coupled 16m optical cavity to diminish anti-squeezing at frequencies below 90Hz where it exacerbates QRPN, while preserving beneficial squeezing at higher frequencies. This is called an amplitude filter cavity, and it is useful for avoiding degradation of detector sensitivity at low frequencies. The attenuation from the cavity also provides technical advantages such as mitigating backscatter.
△ Less
Submitted 12 November, 2020; v1 submitted 18 August, 2020;
originally announced August 2020.
-
Optimal detuning for quantum filter cavities
Authors:
Chris Whittle,
Kentaro Komori,
Dhruva Ganapathy,
Lee McCuller,
Lisa Barsotti,
Nergis Mavalvala,
Matthew Evans
Abstract:
Vacuum quantum fluctuations impose a fundamental limit on the sensitivity of gravitational-wave interferometers, which rank among the most sensitive precision measurement devices ever built. The injection of conventional squeezed vacuum reduces quantum noise in one quadrature at the expense of increasing noise in the other. While this approach improved the sensitivity of the Advanced LIGO and Adva…
▽ More
Vacuum quantum fluctuations impose a fundamental limit on the sensitivity of gravitational-wave interferometers, which rank among the most sensitive precision measurement devices ever built. The injection of conventional squeezed vacuum reduces quantum noise in one quadrature at the expense of increasing noise in the other. While this approach improved the sensitivity of the Advanced LIGO and Advanced Virgo interferometers during their third observing run (O3), future improvements in arm power and squeezing levels will bring radiation pressure noise to the forefront. Installation of a filter cavity for frequency-dependent squeezing provides broadband reduction of quantum noise through the mitigation of this radiation pressure noise, and it is the baseline approach planned for all of the future gravitational-wave detectors currently conceived. The design and operation of a filter cavity requires careful consideration of interferometer optomechanics as well as squeezing degradation processes. In this paper, we perform an in-depth analysis to determine the optimal operating point of a filter cavity. We use our model alongside numerical tools to study the implications for filter cavities to be installed in the upcoming "A+" upgrade of the Advanced LIGO detectors.
△ Less
Submitted 12 November, 2020; v1 submitted 18 August, 2020;
originally announced August 2020.
-
Improving the Robustness of the Advanced LIGO Detectors to Earthquakes
Authors:
Eyal Schwartz,
A Pele,
J Warner,
B Lantz,
J Betzwieser,
K L Dooley,
S Biscans,
M Coughlin,
N Mukund,
R Abbott,
C Adams,
R X Adhikari,
A Ananyeva,
S Appert,
K Arai,
J S Areeda,
Y Asali,
S M Aston,
C Austin,
A M Baer,
M Ball,
S W Ballmer,
S Banagiri,
D Barker,
L Barsotti
, et al. (174 additional authors not shown)
Abstract:
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differenti…
▽ More
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differential motion of the interferometer arms with respect to one another, resulting in a reduction of DARM signal at frequencies below 100\,mHz. Our method greatly improved the interferometers' capability to remain operational during earthquakes, with ground velocities up to 3.9\,$μ\mbox{m/s}$ rms in the beam direction, setting a new record for both detectors. This sets a milestone in seismic controls of the Advanced LIGO detectors' ability to manage high ground motion induced by earthquakes, opening a path for further robust operation in other extreme environmental conditions.
△ Less
Submitted 24 July, 2020;
originally announced July 2020.
-
Frequency-Dependent Squeezing for Advanced LIGO
Authors:
L. McCuller,
C. Whittle,
D. Ganapathy,
K. Komori,
M. Tse,
A. Fernandez-Galiana,
L. Barsotti,
P. Fritschel,
M. MacInnis,
F. Matichard,
K. Mason,
N. Mavalvala,
R. Mittleman,
Haocun Yu,
M. E. Zucker,
M. Evans
Abstract:
The first detection of gravitational waves by the Laser Interferometer Gravitational-wave Observatory (LIGO) in 2015 launched the era of gravitational wave astronomy. The quest for gravitational wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of li…
▽ More
The first detection of gravitational waves by the Laser Interferometer Gravitational-wave Observatory (LIGO) in 2015 launched the era of gravitational wave astronomy. The quest for gravitational wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light is being used to improve the shot noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above $\sim 50$ Hz. Below this frequency, quantum back action, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30Hz, using a 16m long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."
△ Less
Submitted 26 March, 2020;
originally announced March 2020.
-
A compact actively damped vibration isolation platform for optical experiments in ultra-high vacuum
Authors:
Álvaro Fernández-Galiana,
Lee McCuller,
Jeff Kissel,
Lisa Barsotti,
John Miller,
Maggie Tse,
Matthew Evans,
Stuart M. Aston,
Thomas J. Shaffer,
Arnaud Pele,
Janeen H. Romie,
Betsy Weaver,
Richard Abbott,
Peter Fritschel,
Nergis Mavalvala,
Fabrice Matichard
Abstract:
We present a tabletop six-axis vibration isolation system, compatible with Ultra-High Vacuum (UHV), which is actively damped and provides 25 dB of isolation at 10 Hz and 65 dB at 100 Hz. While this isolation platform has been primarily designed to support optics in the Laser Interferometer Gravitational-Wave Observatory (LIGO) detectors, it is suitable for a variety of applications. The system has…
▽ More
We present a tabletop six-axis vibration isolation system, compatible with Ultra-High Vacuum (UHV), which is actively damped and provides 25 dB of isolation at 10 Hz and 65 dB at 100 Hz. While this isolation platform has been primarily designed to support optics in the Laser Interferometer Gravitational-Wave Observatory (LIGO) detectors, it is suitable for a variety of applications. The system has been engineered to facilitate the construction and assembly process, while minimizing cost. The platform provides passive isolation for six degrees of freedom using a combination of vertical springs and horizontal pendula. It is instrumented with voice-coil actuators and optical shadow sensors to damp the resonances. All materials are compatible with stringent vacuum requirements. Thanks to its architecture, the system's footprint can be adapted to meet spatial requirements, while maximizing the dimensions of the optical table. Three units are currently operating for LIGO. We present the design of the system, controls principle, and experimental results.
△ Less
Submitted 24 July, 2019; v1 submitted 24 January, 2019;
originally announced January 2019.
-
The Holometer: An Instrument to Probe Planckian Quantum Geometry
Authors:
Aaron Chou,
Henry Glass,
H. Richard Gustafson,
Craig Hogan,
Brittany L. Kamai,
Ohkyung Kwon,
Robert Lanza,
Lee McCuller,
Stephan S. Meyer,
Jonathan Richardson,
Chris Stoughton,
Ray Tomlin,
Rainer Weiss
Abstract:
This paper describes the Fermilab Holometer, an instrument for measuring correlations of position variations over a four-dimensional volume of space-time. The apparatus consists of two co-located, but independent and isolated, 40m power-recycled Michelson interferometers, whose outputs are cross-correlated to 25 MHz. The data are sensitive to correlations of differential position across the appara…
▽ More
This paper describes the Fermilab Holometer, an instrument for measuring correlations of position variations over a four-dimensional volume of space-time. The apparatus consists of two co-located, but independent and isolated, 40m power-recycled Michelson interferometers, whose outputs are cross-correlated to 25 MHz. The data are sensitive to correlations of differential position across the apparatus over a broad band of frequencies up to and exceeding the inverse light crossing time, 7.6 MHz. A noise model constrained by diagnostic and environmental data distinguishes among physical origins of measured correlations, and is used to verify shot-noise-limited performance. These features allow searches for exotic quantum correlations that depart from classical trajectories at spacelike separations, with a strain noise power spectral density sensitivity smaller than the Planck time. The Holometer in current and future configurations is projected to provide precision tests of a wide class of models of quantum geometry at the Planck scale, beyond those already constrained by currently operating gravitational wave observatories.
△ Less
Submitted 26 February, 2017; v1 submitted 24 November, 2016;
originally announced November 2016.
-
First measurements of high frequency cross-spectra from a pair of large Michelson interferometers
Authors:
Aaron S. Chou,
Richard Gustafson,
Craig Hogan,
Brittany Kamai,
Ohkyung Kwon,
Robert Lanza,
Lee McCuller,
Stephan S. Meyer,
Jonathan Richardson,
Chris Stoughton,
Raymond Tomlin,
Samuel Waldman,
Rainer Weiss
Abstract:
Measurements are reported of the cross-correlation of spectra of differential position signals from the Fermilab Holometer, a pair of co-located 39 m long, high power Michelson interferometers with flat, broadband frequency response in the MHz range. The instrument obtains sensitivity to high frequency correlated signals far exceeding any previous measurement in a broad frequency band extending be…
▽ More
Measurements are reported of the cross-correlation of spectra of differential position signals from the Fermilab Holometer, a pair of co-located 39 m long, high power Michelson interferometers with flat, broadband frequency response in the MHz range. The instrument obtains sensitivity to high frequency correlated signals far exceeding any previous measurement in a broad frequency band extending beyond the 3.8 MHz inverse light crossing time of the apparatus. The dominant but uncorrelated shot noise is averaged down over $2\times 10^8$ independent spectral measurements with 381 Hz frequency resolution to obtain $2.1\times 10^{-20} \ \mathrm{m}/\sqrt{\mathrm{Hz}}$ sensitivity to stationary signals. For signal bandwidths $Δf > 11$ kHz, the sensitivity to strain $h$ or shear power spectral density of classical or exotic origin surpasses a milestone $PSD_{δh} < t_p$ where $t_p= 5.39\times 10^{-44}/\mathrm{Hz}$ is the Planck time.
△ Less
Submitted 18 January, 2017; v1 submitted 3 December, 2015;
originally announced December 2015.