-
A High Efficiency Photon Veto for the Light Dark Matter eXperiment
Authors:
Torsten Åkesson,
Nikita Blinov,
Lene Bryngemark,
Owen Colegrove,
Giulia Collura,
Craig Dukes. Valentina Dutta,
Bertrand Echenard,
Thomas Eichlersmith,
Craig Group,
Joshua Hiltbrand,
David G. Hitlin,
Joseph Incandela,
Gordan Krnjaic,
Juan Lazaro,
Amina Li,
Jeremiah Mans,
Phillip Masterson,
Jeremy McCormick,
Omar Moreno,
Geoffrey Mullier,
Akshay Nagar,
Timothy Nelson,
Gavin Niendorf,
James Oyang,
Reese Petersen
, et al. (6 additional authors not shown)
Abstract:
Fixed-target experiments using primary electron beams can be powerful discovery tools for light dark matter in the sub-GeV mass range. The Light Dark Matter eXperiment (LDMX) is designed to measure missing momentum in high-rate electron fixed-target reactions with beam energies of 4 GeV to 16 GeV. A prerequisite for achieving several important sensitivity milestones is the capability to efficientl…
▽ More
Fixed-target experiments using primary electron beams can be powerful discovery tools for light dark matter in the sub-GeV mass range. The Light Dark Matter eXperiment (LDMX) is designed to measure missing momentum in high-rate electron fixed-target reactions with beam energies of 4 GeV to 16 GeV. A prerequisite for achieving several important sensitivity milestones is the capability to efficiently reject backgrounds associated with few-GeV bremsstrahlung, by twelve orders of magnitude, while maintaining high efficiency for signal. The primary challenge arises from events with photo-nuclear reactions faking the missing-momentum property of a dark matter signal. We present a methodology developed for the LDMX detector concept that is capable of the required rejection. By employing a detailed GEANT4-based model of the detector response, we demonstrate that the sampling calorimetry proposed for LDMX can achieve better than $10^{-13}$ rejection of few-GeV photons. This suggests that the luminosity-limited sensitivity of LDMX can be realized at 4 GeV and higher beam energies.
△ Less
Submitted 11 December, 2019;
originally announced December 2019.
-
ARIADNE -- A Novel Optical LArTPC: Technical Design Report and Initial Characterisation using a Secondary Beam from the CERN PS and Cosmic Muons
Authors:
D. Hollywood,
K. Majumdar,
K. Mavrokoridis,
K. J. McCormick,
B. Philippou,
S. Powell,
A. Roberts,
N. A. Smith,
G. Stavrakis,
C. Touramanis,
J. Vann
Abstract:
ARIADNE is a 1-ton (330 kg fiducial mass) dual-phase liquid argon (LAr) time projection chamber (TPC) featuring a novel optical readout. Four electron-multiplying charge-coupled device (EMCCD) cameras are mounted externally, and these capture the secondary scintillation light produced in the holes of a thick electron gas multiplier (THGEM). Track reconstruction using this novel readout approach is…
▽ More
ARIADNE is a 1-ton (330 kg fiducial mass) dual-phase liquid argon (LAr) time projection chamber (TPC) featuring a novel optical readout. Four electron-multiplying charge-coupled device (EMCCD) cameras are mounted externally, and these capture the secondary scintillation light produced in the holes of a thick electron gas multiplier (THGEM). Track reconstruction using this novel readout approach is demonstrated. Optical readout has the potential to be a cost effective alternative to charge readout in future LArTPCs. In this paper, the technical design of the detector is detailed. Results of mixed particle detection using a secondary beam from the CERN PS (representing the first ever optical images of argon interactions in a dual-phase LArTPC at a beamline) and cosmic muon detection at the University of Liverpool are also presented.
△ Less
Submitted 3 March, 2020; v1 submitted 8 October, 2019;
originally announced October 2019.
-
Radiative transfer in half spaces of arbitrary dimension
Authors:
Eugene d'Eon,
Norman J. McCormick
Abstract:
We solve the classic albedo and Milne problems of plane-parallel illumination of an isotropically-scattering half-space when generalized to a Euclidean domain $\mathbb{R}^d$ for arbitrary $d \ge 1$. A continuous family of pseudo-problems and related $H$ functions arises and includes the classical 3D solutions, as well as 2D "Flatland" and rod-model solutions, as special cases. The Case-style eigen…
▽ More
We solve the classic albedo and Milne problems of plane-parallel illumination of an isotropically-scattering half-space when generalized to a Euclidean domain $\mathbb{R}^d$ for arbitrary $d \ge 1$. A continuous family of pseudo-problems and related $H$ functions arises and includes the classical 3D solutions, as well as 2D "Flatland" and rod-model solutions, as special cases. The Case-style eigenmode method is applied to the general problem and the internal scalar densities, emerging distributions, and their respective moments are expressed in closed-form. Universal properties invariant to dimension $d$ are highlighted and we find that a discrete diffusion mode is not universal for $d > 3$ in absorbing media. We also find unexpected correspondences between differing dimensions and between anisotropic 3D scattering and isotropic scattering in high dimension.
△ Less
Submitted 19 May, 2019;
originally announced May 2019.
-
Light Dark Matter eXperiment (LDMX)
Authors:
Torsten Åkesson,
Asher Berlin,
Nikita Blinov,
Owen Colegrove,
Giulia Collura,
Valentina Dutta,
Bertrand Echenard,
Joshua Hiltbrand,
David G. Hitlin,
Joseph Incandela,
John Jaros,
Robert Johnson,
Gordan Krnjaic,
Jeremiah Mans,
Takashi Maruyama,
Jeremy McCormick,
Omar Moreno,
Timothy Nelson,
Gavin Niendorf,
Reese Petersen,
Ruth Pöttgen,
Philip Schuster,
Natalia Toro,
Nhan Tran,
Andrew Whitbeck
Abstract:
We present an initial design study for LDMX, the Light Dark Matter Experiment, a small-scale accelerator experiment having broad sensitivity to both direct dark matter and mediator particle production in the sub-GeV mass region. LDMX employs missing momentum and energy techniques in multi-GeV electro-nuclear fixed-target collisions to explore couplings to electrons in uncharted regions that extend…
▽ More
We present an initial design study for LDMX, the Light Dark Matter Experiment, a small-scale accelerator experiment having broad sensitivity to both direct dark matter and mediator particle production in the sub-GeV mass region. LDMX employs missing momentum and energy techniques in multi-GeV electro-nuclear fixed-target collisions to explore couplings to electrons in uncharted regions that extend down to and below levels that are motivated by direct thermal freeze-out mechanisms. LDMX would also be sensitive to a wide range of visibly and invisibly decaying dark sector particles, thereby addressing many of the science drivers highlighted in the 2017 US Cosmic Visions New Ideas in Dark Matter Community Report. LDMX would achieve the required sensitivity by leveraging existing and develo** detector technologies from the CMS, HPS and Mu2e experiments. In this paper, we present our initial design concept, detailed GEANT-based studies of detector performance, signal and background processes, and a preliminary analysis approach. We demonstrate how a first phase of LDMX could expand sensitivity to a variety of light dark matter, mediator, and millicharge particles by several orders of magnitude in coupling over the broad sub-GeV mass range.
△ Less
Submitted 15 August, 2018;
originally announced August 2018.
-
The HPS electromagnetic calorimeter
Authors:
Ilaria Balossino,
Nathan Baltzell,
Marco Battaglieri,
Mariangela Bondi,
Emma Buchanan,
Daniela Calvo,
Andrea Celentano,
Gabriel Charles,
Luca Colaneri,
Annalisa D'Angelo,
Marzio De Napoli,
Raffaella De Vita,
Raphael Dupre,
Hovanes Egiyan,
Mathieu Ehrhart,
Alessandra Filippi,
Michel Garcon,
Nerses Gevorgyan,
Francois-Xavier Girod,
Michel Guidal,
Maurik Holtrop,
Volodymyr Iurasov,
Valery Kubarovsky,
Kenneth Livingston,
Kyle McCarty
, et al. (14 additional authors not shown)
Abstract:
The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon." Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HP…
▽ More
The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon." Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015-2016. The calorimeter's main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. The detector is a homogeneous calorimeter, made of 442 lead-tungstate (PbWO4) scintillating crystals, each read out by an avalanche photodiode coupled to a custom trans-impedance amplifier.
△ Less
Submitted 2 February, 2017; v1 submitted 14 October, 2016;
originally announced October 2016.
-
Development of the kaon tagging system for the NA62 experiment at CERN
Authors:
Evgueni Goudzovski,
Marian Krivda,
Cristina Lazzeroni,
Karim Massri,
Francis O. Newson,
Simon Pyatt,
Angela Romano,
Xen Serghi,
Antonino Sergi,
Richard J. Staley,
Helen F. Heath,
Ryan F. Page,
Antonio Cassese,
Peter A. Cooke,
John B. Dainton,
John R. Fry,
Liam D. J. Fulton,
Emlyn Jones,
Tim J. Jones,
Kevin J. McCormick,
Peter Sutcliffe,
Bozydar Wrona
Abstract:
The NA62 experiment at CERN aims to make a precision measurement of the ultra-rare decay $K^{+} \rightarrow π^{+}ν\overlineν$, and relies on a differential Cherenkov detector (KTAG) to identify charged kaons at an average rate of 50 MHz in a 750 MHz unseparated hadron beam. The experimental sensitivity of NA62 to K-decay branching ratios (BR) of $10^{-11}$ requires a time resolution for the KTAG o…
▽ More
The NA62 experiment at CERN aims to make a precision measurement of the ultra-rare decay $K^{+} \rightarrow π^{+}ν\overlineν$, and relies on a differential Cherenkov detector (KTAG) to identify charged kaons at an average rate of 50 MHz in a 750 MHz unseparated hadron beam. The experimental sensitivity of NA62 to K-decay branching ratios (BR) of $10^{-11}$ requires a time resolution for the KTAG of better than 100 ps, an efficiency better than 95% and a contamination of the kaon sample that is smaller than $10^{-4}$. A prototype version of the detector was tested in 2012, during the first NA62 technical run, in which the required resolution of 100 ps was achieved and the necessary functionality of the light collection system and electronics was demonstrated.
△ Less
Submitted 12 September, 2015;
originally announced September 2015.
-
First Demonstration of Imaging Cosmic Muons in a Two-Phase Liquid Argon TPC using an EMCCD Camera and a THGEM
Authors:
K. Mavrokoridis,
J. Carroll,
K. J. McCormick,
P. Paudyal,
A. Roberts,
N. A. Smith,
C. Touramanis
Abstract:
Colossal two-phase Liquid Argon Time Projection Chambers (LAr TPCs) are a proposed option for future long-baseline neutrino experiments. This study illustrates the feasibility of using an EMCCD camera to capture light induced by single cosmic events in a two-phase LAr TPC employing a THGEM. An Andor iXon Ultra 897 EMCCD camera was externally mounted via a borosilicate glass viewport on the Liverpo…
▽ More
Colossal two-phase Liquid Argon Time Projection Chambers (LAr TPCs) are a proposed option for future long-baseline neutrino experiments. This study illustrates the feasibility of using an EMCCD camera to capture light induced by single cosmic events in a two-phase LAr TPC employing a THGEM. An Andor iXon Ultra 897 EMCCD camera was externally mounted via a borosilicate glass viewport on the Liverpool two-phase LAr TPC. The camera successfully captured the secondary scintillation light produced at the THGEM holes that had been induced by cosmic events. The light collection capability of the camera for various EMCCD gains was assessed. For a THGEM gain of 64 and an EMCCD gain of 1000, clear images were captured with an average signal-to-noise ratio of 6. Preliminary 3D reconstruction of straight cosmic muon tracks has been performed by combining the camera images, PMT signals and THGEM charge data. Reconstructed cosmic muon tracks were used to determine THGEM gain and to calibrate the intensity levels of the EMCCD image.
△ Less
Submitted 23 July, 2015;
originally announced July 2015.
-
The Heavy Photon Search Test Detector
Authors:
Marco Battaglieri,
Sergey Boyarinov,
Stephen Bueltmann,
Volker Burkert,
Andrea Celentano,
Gabriel Charles,
William Cooper,
Chris Cuevas,
Natalia Dashyan,
Raffaella DeVita,
Camille Desnault,
Alexandre Deur,
Hovanes Egiyan,
Latifa Elouadrhiri,
Rouven Essig,
Vitaliy Fadeyev,
Clive Field,
Arne Freyberger,
Yuri Gershtein,
Nerses Gevorgyan,
Francois-Xavier Girod,
Norman Graf,
Mathew Graham,
Keith Griffioen,
Alexander Grillo
, et al. (39 additional authors not shown)
Abstract:
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm th…
▽ More
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm that the trigger rates and occupancies are as expected. This paper describes the HPS Test Run apparatus and readout electronics and its performance. In this setting, a heavy photon can be identified as a narrow peak in the e$^+$e$^-$ invariant mass spectrum, above the trident background or as a narrow invariant mass peak with a decay vertex displaced from the production target, so charged particle tracking and vertexing are needed for its detection. In the HPS Test Run, charged particles are measured with a compact forward silicon microstrip tracker inside a dipole magnet. Electromagnetic showers are detected in a PbW0$_{4}$ crystal calorimeter situated behind the magnet, and are used to trigger the experiment and identify electrons and positrons. Both detectors are placed close to the beam line and split top-bottom. This arrangement provides sensitivity to low-mass heavy photons, allows clear passage of the unscattered beam, and avoids the spray of degraded electrons coming from the target. The discrimination between prompt and displaced e$^+$e$^-$ pairs requires the first layer of silicon sensors be placed only 10~cm downstream of the target. The expected signal is small, and the trident background huge, so the experiment requires very large statistics. Accordingly, the HPS Test Run utilizes high-rate readout and data acquisition electronics and a fast trigger to exploit the essentially 100% duty cycle of the CEBAF accelerator at JLab.
△ Less
Submitted 4 June, 2015; v1 submitted 23 June, 2014;
originally announced June 2014.
-
Optical Readout of a Two Phase Liquid Argon TPC using CCD Camera and THGEMs
Authors:
K. Mavrokoridis,
F. Ball,
J. Carroll,
M. Lazos,
K. J. McCormick,
N. A. Smith,
C. Touramanis,
J. Walker
Abstract:
This paper presents a preliminary study into the use of CCDs to image secondary scintillation light generated by THick Gas Electron Multipliers (THGEMs) in a two phase LAr TPC. A Sony ICX285AL CCD chip was mounted above a double THGEM in the gas phase of a 40 litre two-phase LAr TPC with the majority of the camera electronics positioned externally via a feedthrough. An Am-241 source was mounted on…
▽ More
This paper presents a preliminary study into the use of CCDs to image secondary scintillation light generated by THick Gas Electron Multipliers (THGEMs) in a two phase LAr TPC. A Sony ICX285AL CCD chip was mounted above a double THGEM in the gas phase of a 40 litre two-phase LAr TPC with the majority of the camera electronics positioned externally via a feedthrough. An Am-241 source was mounted on a rotatable motion feedthrough allowing the positioning of the alpha source either inside or outside of the field cage. Developed for and incorporated into the TPC design was a novel high voltage feedthrough featuring LAr insulation. Furthermore, a range of webcams were tested for operation in cryogenics as an internal detector monitoring tool. Of the range of webcams tested the Microsoft HD-3000 (model no:1456) webcam was found to be superior in terms of noise and lowest operating temperature.
In ambient temperature and atmospheric pressure 1 ppm pure argon gas, the THGEM gain was approximately 1000 and using a 1 msec exposure the CCD captured single alpha tracks. Successful operation of the CCD camera in two-phase cryogenic mode was also achieved. Using a 10 sec exposure a photograph of secondary scintillation light induced by the Am-241 source in LAr has been captured for the first time.
△ Less
Submitted 20 February, 2014; v1 submitted 2 January, 2014;
originally announced January 2014.
-
Argon Purification Studies and a Novel Liquid Argon Re-circulation System
Authors:
K. Mavrokoridis,
R. G. Calland,
J. Coleman,
P. K. Lightfoot,
N. McCauley,
K. J. McCormick,
C. Touramanis
Abstract:
Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a comprehensive study of the effects of electronegative impurity on gaseous and liquid argon scintillation light, an analysis of the efficacy of various purificat…
▽ More
Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a comprehensive study of the effects of electronegative impurity on gaseous and liquid argon scintillation light, an analysis of the efficacy of various purification chemicals, as well as the Liverpool LAr setup, which utilises a novel re-circulation purification system. Of the impurities tested - Air, O_2, H_2O, N_2 and CO_2 in the range of between 0.01 ppm to 1000 ppm - H_2O was found to have the most profound effect on gaseous argon scintillation light, and N_2 was found to have the least. Additionally, a correlation between the slow component decay time and the total energy deposited with 0.01 ppm - 100 ppm O_2 contamination levels in liquid argon has been established. The superiority of molecular sieves over anhydrous complexes at absorbing Ar gas, N_2 gas and H_2O vapour has been quantified using BET isotherm analysis. The efficiency of Cu and P_2O5 at removing O_2 and H_2O impurities from 1 bar N6 argon gas at both room temperature and -130 ^oC was investigated and found to be high. A novel, highly scalable LAr re-circulation system has been developed. The complete system, consisting of a motorised bellows pump operating in liquid and a purification cartridge, were designed and built in-house. The system was operated successfully over many days and achieved a re-circulation rate of 27 litres/hour and high purity.
△ Less
Submitted 26 June, 2011;
originally announced June 2011.
-
LCDG4 and DigiSim - Simulation activities at NICADD/NIU
Authors:
D. Beznosko,
G. Blazey,
D. Chakraborty,
A. Dyshkant,
K. Francis,
D. Kubik,
J. G. R. Lima,
J. McCormick,
R. McIntosh,
V. Rykalin,
V. Zutshi
Abstract:
We present two software packages developed to support detector R&D studies for the International Linear Collider. LCDG4 is a full-detector simulator that provides energy deposits from particles traversing the sensitive volumes of the detector. It has been extensively used within the American ILC community, providing data for algorithm development and detector optimization studies. DigiSim models…
▽ More
We present two software packages developed to support detector R&D studies for the International Linear Collider. LCDG4 is a full-detector simulator that provides energy deposits from particles traversing the sensitive volumes of the detector. It has been extensively used within the American ILC community, providing data for algorithm development and detector optimization studies. DigiSim models real-life digitization effects, converting the idealized response into simulated detector readout. It has many useful features to improve the realism in modeling detector response. The main characteristics of these two complementary packages are discussed.
△ Less
Submitted 28 July, 2005;
originally announced July 2005.