-
The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing Module
Authors:
Zachary B. Huber,
Yaqiong Li,
Eve M. Vavagiakis,
Steve K. Choi,
Jake Connors,
Nicholas F. Cothard,
Cody J. Duell,
Nicholas Galitzki,
Erin Healy,
Johannes Hubmayr,
Bradley R. Johnson,
Benjamin Keller,
Heather McCarrick,
Michael D. Niemack,
Yuhan Wang,
Zhilei Xu,
Kaiwen Zheng
Abstract:
The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field…
▽ More
The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field pickup and that it is hard to predict how they will respond to such fields, it is important to characterize the magnetic response of these systems empirically. This information can then be used to limit spurious signals by informing magnetic shielding designs for the detectors and readout. This paper focuses on measurements of magnetic pickup with different magnetic shielding configurations for the SO universal multiplexing module (UMM), which contains the SQUIDs, associated resonators, and TES bias circuit. The magnetic pickup of a prototype UMM was tested under three shielding configurations: no shielding (copper packaging), aluminum packaging for the UMM, and a tin/lead-plated shield surrounding the entire dilution refrigerator 100 mK cold stage. The measurements show that the aluminum packaging outperforms the copper packaging by a shielding factor of 8-10, and adding the tin/lead-plated 1K shield further increases the relative shielding factor in the aluminum configuration by 1-2 orders of magnitude.
△ Less
Submitted 1 March, 2023; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Simons Observatory Focal-Plane Module: In-lab Testing and Characterization Program
Authors:
Yuhan Wang,
Kaiwen Zheng,
Zachary Atkins,
Jason Austermann,
Tanay Bhandarkar,
Steve K. Choi,
Shannon M. Duff,
Daniel Dutcher,
Nicholas Galitzki,
Erin Healy,
Zachary B. Huber,
Johannes Hubmayr,
Bradley R. Johnson,
Jack Lashner,
Yaqiong Li,
Heather McCarrick,
Michael D. Niemack,
Joseph Seibert,
Maximiliano Silva-Feaver,
Rita Sonka,
Suzanne T. Staggs,
Eve Vavagiakis,
Zhilei Xu
Abstract:
The Simons Observatory (SO) is a ground-based cosmic microwave background instrument to be sited in the Atacama Desert in Chile. SO will deploy 60,000 transition-edge sensor bolometers in 49 separate focal-plane modules across a suite of four telescopes covering three dichroic bands termed low frequency (LF), mid frequency (MF) and ultra-high frequency (UHF). Each MF and UHF focal-plane module pac…
▽ More
The Simons Observatory (SO) is a ground-based cosmic microwave background instrument to be sited in the Atacama Desert in Chile. SO will deploy 60,000 transition-edge sensor bolometers in 49 separate focal-plane modules across a suite of four telescopes covering three dichroic bands termed low frequency (LF), mid frequency (MF) and ultra-high frequency (UHF). Each MF and UHF focal-plane module packages 1720 optical detectors and corresponding 100 mK microwave SQUID multiplexing readout components. In this paper we describe the testing program we have developed for high-throughput validation of the modules after they are assembled. The validation requires measurements of the yield, saturation powers, time constants, noise properties and optical efficiencies. Additional measurements will be performed for further characterizations as needed. We describe the methods developed and demonstrate preliminary results from initial testing of prototype modules.
△ Less
Submitted 5 July, 2022; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Simons Observatory Microwave SQUID Multiplexing Readout -- Cryogenic RF Amplifier and Coaxial Chain Design
Authors:
Mayuri Sathyanarayana Rao,
Maximiliano Silva-Feaver,
Aamir Ali,
Kam Arnold,
Peter Ashton,
Bradley J. Dober,
Cody J. Duell,
Shannon M. Duff,
Nicholas Galitzki,
Erin Healy,
Shawn Henderson,
Shuay-Pwu Patty Ho,
Jonathan Hoh,
Anna M. Kofman,
Akito Kusaka,
Adrian T. Lee,
Aashrita Mangu,
Justin Mathewson,
Philip Mauskopf,
Heather McCarrick,
Jenna Moore,
Michael D. Niemack,
Christopher Raum,
Maria Salatino,
Trevor Sasse
, et al. (11 additional authors not shown)
Abstract:
The Simons Observatory (SO) is an upcoming polarization-sensitive Cosmic Microwave Background (CMB) experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of \bigO(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiple…
▽ More
The Simons Observatory (SO) is an upcoming polarization-sensitive Cosmic Microwave Background (CMB) experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of \bigO(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of \bigO{(1,000)}, microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to Transition Edge Sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.
△ Less
Submitted 19 March, 2020;
originally announced March 2020.
-
Magnetic field dependence of the internal quality factor and noise performance of lumped-element kinetic inductance detectors
Authors:
Daniel Flanigan,
Bradley R. Johnson,
Maximilian H. Abitbol,
Sean Bryan,
Robin Cantor,
Peter K. Day,
Glenn Jones,
Philip Mauskopf,
Heather McCarrick,
Amber Miller,
Jonas Zmuidzinas
Abstract:
We present a technique for increasing the internal quality factor of kinetic inductance detectors (KIDs) by nulling ambient magnetic fields with a properly applied magnetic field. The KIDs used in this study are made from thin-film aluminum, they are mounted inside a light-tight package made from bulk aluminum, and they are operated near $150 \, \mathrm{mK}$. Since the thin-film aluminum has a sli…
▽ More
We present a technique for increasing the internal quality factor of kinetic inductance detectors (KIDs) by nulling ambient magnetic fields with a properly applied magnetic field. The KIDs used in this study are made from thin-film aluminum, they are mounted inside a light-tight package made from bulk aluminum, and they are operated near $150 \, \mathrm{mK}$. Since the thin-film aluminum has a slightly elevated critical temperature ($T_\mathrm{c} = 1.4 \, \mathrm{K}$), it therefore transitions before the package ($T_\mathrm{c} = 1.2 \, \mathrm{K}$), which also serves as a magnetic shield. On cooldown, ambient magnetic fields as small as approximately $30 \, \mathrm{μT}$ can produce vortices in the thin-film aluminum as it transitions because the bulk aluminum package has not yet transitioned and therefore is not yet shielding. These vortices become trapped inside the aluminum package below $1.2 \, \mathrm{K}$ and ultimately produce low internal quality factors in the thin-film superconducting resonators. We show that by controlling the strength of the magnetic field present when the thin film transitions, we can control the internal quality factor of the resonators. We also compare the noise performance with and without vortices present, and find no evidence for excess noise beyond the increase in amplifier noise, which is expected with increasing loss.
△ Less
Submitted 20 September, 2016;
originally announced September 2016.
-
The Detector System for the Stratospheric Kinetic Inductance Polarimeter (SKIP)
Authors:
B. R. Johnson,
P. A. R. Ade,
D. Araujo,
K. J. Bradford,
D. Chapman,
P. K. Day,
J. Didier,
S. Doyle,
H. K. Eriksen,
D. Flanigan,
C. Groppi,
S. Hillbrand,
G. Jones,
M. Limon,
P. Mauskopf,
H. McCarrick,
A. Miller,
T. Mroczkowski,
B. Reichborn-Kjennerud,
B. Smiley,
J. Sobrin,
I. K. Wehus,
J. Zmuidzinas
Abstract:
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed balloon-borne experiment designed to study the cosmic microwave background, the cosmic infrared background and Galactic dust emission by observing 1133 square degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden. The instrument contains 2317 single-polarization, horn-coupled, aluminum lumped-element kineti…
▽ More
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed balloon-borne experiment designed to study the cosmic microwave background, the cosmic infrared background and Galactic dust emission by observing 1133 square degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden. The instrument contains 2317 single-polarization, horn-coupled, aluminum lumped-element kinetic inductance detectors (LEKID). The LEKIDs will be maintained at 100 mK with an adiabatic demagnetization refrigerator. The polarimeter operates in two configurations, one sensitive to a spectral band centered on 150 GHz and the other sensitive to 260 and 350 GHz bands. The detector readout system is based on the ROACH-1 board, and the detectors will be biased below 300 MHz. The detector array is fed by an F/2.4 crossed-Dragone telescope with a 500 mm aperture yielding a 15 arcmin FWHM beam at 150 GHz. To minimize detector loading and maximize sensitivity, the entire optical system will be cooled to 1 K. Linearly polarized sky signals will be modulated with a metal-mesh half-wave plate that is mounted at the telescope aperture and rotated by a superconducting magnetic bearing. The observation program consists of at least two, five-day flights beginning with the 150 GHz observations.
△ Less
Submitted 5 January, 2014; v1 submitted 1 August, 2013;
originally announced August 2013.