-
The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)
Authors:
LEGEND Collaboration,
N. Abgrall,
A. Abramov,
N. Abrosimov,
I. Abt,
M. Agostini,
M. Agartioglu,
A. Ajjaq,
S. I. Alvis,
F. T. Avignone III,
X. Bai,
M. Balata,
I. Barabanov,
A. S. Barabash,
P. J. Barton,
L. Baudis,
L. Bezrukov,
T. Bode,
A. Bolozdynya,
D. Borowicz,
A. Boston,
H. Boston,
S. T. P. Boyd,
R. Breier,
V. Brudanin
, et al. (208 additional authors not shown)
Abstract:
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely…
▽ More
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of $\sim$0.1 count /(FWHM$\cdot$t$\cdot$yr) in the region of the signal. The current generation $^{76}$Ge experiments GERDA and the MAJORANA DEMONSTRATOR utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0$νββ$ signal region of all 0$νββ$ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment. The collaboration aims to develop a phased 0$νββ$ experimental program with discovery potential at a half-life approaching or at $10^{28}$ years, using existing resources as appropriate to expedite physics results.
△ Less
Submitted 6 September, 2017;
originally announced September 2017.
-
Spectral Calibration of the Fluorescence Telescopes of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila,
A. M. Badescu,
A. Balaceanu,
F. Barbato,
R. J. Barreira Luz
, et al. (381 additional authors not shown)
Abstract:
We present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. We used a portable light source based on a xenon flasher and a monochromator to measure the relative spectral efficiencies of eight telescopes in steps of 5 nm from 280 nm to 440 nm. Each point in a scan had approximately 2 nm FWHM out of the monochromator.…
▽ More
We present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. We used a portable light source based on a xenon flasher and a monochromator to measure the relative spectral efficiencies of eight telescopes in steps of 5 nm from 280 nm to 440 nm. Each point in a scan had approximately 2 nm FWHM out of the monochromator. Different sets of telescopes in the observatory have different optical components, and the eight telescopes measured represent two each of the four combinations of components represented in the observatory. We made an end-to-end measurement of the response from different combinations of optical components, and the monochromator setup allowed for more precise and complete measurements than our previous multi-wavelength calibrations. We find an overall uncertainty in the calibration of the spectral response of most of the telescopes of 1.5% for all wavelengths; the six oldest telescopes have larger overall uncertainties of about 2.2%. We also report changes in physics measureables due to the change in calibration, which are generally small.
△ Less
Submitted 2 October, 2017; v1 submitted 5 September, 2017;
originally announced September 2017.
-
Muon Counting using Silicon Photomultipliers in the AMIGA detector of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila,
A. M. Badescu
, et al. (400 additional authors not shown)
Abstract:
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is com…
▽ More
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m$^2$ detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98 % efficiency for the highest tested overvoltage, combined with a low probability of accidental counting ($\sim$2 %), show a promising performance for this new system.
△ Less
Submitted 4 October, 2017; v1 submitted 17 March, 2017;
originally announced March 2017.
-
The novel properties of SF$_6$ for directional dark matter experiments
Authors:
N. S. Phan,
R. Lafler,
R. J. Lauer,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller
Abstract:
SF$_{6}$ is an inert and electronegative gas that has a long history of use in high voltage insulation and numerous other industrial applications. Although SF$_{6}$ is used as a trace component to introduce stability in tracking chambers, its highly electronegative properties have limited its use in tracking detectors. In this work we present a series of measurements with SF$_{6}$ as the primary g…
▽ More
SF$_{6}$ is an inert and electronegative gas that has a long history of use in high voltage insulation and numerous other industrial applications. Although SF$_{6}$ is used as a trace component to introduce stability in tracking chambers, its highly electronegative properties have limited its use in tracking detectors. In this work we present a series of measurements with SF$_{6}$ as the primary gas in a low pressure Time Projection Chamber (TPC), with a thick GEM used as the avalanche and readout device. The first results of an $^{55}$Fe energy spectrum in SF$_{6}$ are presented. Measurements of the mobility and longitudinal diffusion confirm the negative ion drift of SF$_{6}$. However, the observed waveforms have a peculiar but interesting structure that indicates multiple drift species and a dependence on the reduced field ($E/p$), as well as on the level of water vapor contamination. The discovery of a distinct secondary peak in the waveform, together with its identification and use for fiducializing events in the TPC, are also presented. Our measurements demonstrate that SF$_{6}$ is an ideal gas for directional dark matter detection. In particular, the high fluorine content is desirable for spin-dependent sensitivity, negative ion drift ensures low diffusion over large drift distances, and the multiple species of charge carriers allow for full detector fiducialization.
△ Less
Submitted 20 December, 2016; v1 submitted 16 September, 2016;
originally announced September 2016.
-
Prototype muon detectors for the AMIGA component of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
R. Alves Batista,
M. Ambrosio,
A. Aminaei,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin
, et al. (429 additional authors not shown)
Abstract:
Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary…
▽ More
Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary Cell, are to identify and resolve all engineering issues as well as to understand the muon-number counting uncertainties related to the design of the detector. The mechanical design, fabrication and deployment processes of the muon counters of the Unitary Cell are described in this document. These muon counters modules comprise sealed PVC casings containing plastic scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier tubes, and acquisition electronics. The modules are buried approximately 2.25 m below ground level in order to minimize contamination from electromagnetic shower particles. The mechanical setup, which allows access to the electronics for maintenance, is also described in addition to tests of the modules' response and integrity. The completed Unitary Cell has measured a number of air showers of which a first analysis of a sample event is included here.
△ Less
Submitted 12 May, 2016; v1 submitted 5 May, 2016;
originally announced May 2016.
-
Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
R. Alves Batista,
M. Ambrosio,
A. Aminaei,
G. A. Anastasi,
L. Anchordoqui,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila
, et al. (426 additional authors not shown)
Abstract:
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected…
▽ More
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method is used for cross-checks that indeed we reach nanosecond-scale timing accuracy by this correction. First, we operate a "beacon transmitter" which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcasts intercepted with a software-defined radio. From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA.
△ Less
Submitted 15 February, 2016; v1 submitted 7 December, 2015;
originally announced December 2015.
-
GEM-based TPC with CCD Imaging for Directional Dark Matter Detection
Authors:
N. S. Phan,
R. J. Lauer,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller
Abstract:
The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the best sensitivity with that of cost effective scale-up requires optimization over a large parameter space. Critical for this are the precision measurements of th…
▽ More
The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the best sensitivity with that of cost effective scale-up requires optimization over a large parameter space. Critical for this are the precision measurements of the fundamental properties of both electron and nuclear recoil tracks down to the lowest detectable energies. Such measurements are necessary to provide a benchmark for background discrimination and directional sensitivity that could be used for future optimization studies for directional dark matter experiments. In this paper we describe a small, high resolution, high signal- to-noise GEM-based TPC with a 2D CCD readout designed for this goal. The performance of the detector was characterized using alpha particles, X-rays, gamma-rays, and neutrons, enabling detailed measurements of electron and nuclear recoil tracks. Stable effective gas gains of greater than $1 \times 10^5$ were obtained in 100 Torr of pure CF$_4$ by a cascade of three standard CERN GEMs each with a 140 $μ$m pitch. The high signal-to-noise and sub-millimeter spatial resolution of the GEM amplification and CCD readout, together with low diffusion, allow for excellent background discrimination between electron and nuclear recoils down below $\sim$10 keVee ($\sim$23 keVr fluorine recoil). Even lower thresholds, necessary for the detection of low mass WIMPs for example, might be achieved by lowering the pressure and utilizing full 3D track reconstruction. These and other paths for improvements are discussed, as are possible fundamental limitations imposed by the physics of energy loss.
△ Less
Submitted 22 September, 2016; v1 submitted 7 October, 2015;
originally announced October 2015.
-
First background-free limit from a directional dark matter experiment: results from a fully fiducialised DRIFT detector
Authors:
J. B. R. Battat,
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. -L. Gauvreau,
M. Gold,
J. L. Harton,
J. M. Landers,
E. Law,
E. R. Lee,
D. Loomba,
A. Lumnah,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
F. Mouton,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. Schuckman,
D. P. Snowden-Ifft
, et al. (6 additional authors not shown)
Abstract:
The addition of O2 to gas mixtures in time projection chambers containing CS2 has recently been shown to produce multiple negative ions that travel at slightly different velocities. This allows a measurement of the absolute position of ionising events in the z (drift) direction. In this work, we apply the z-fiducialisation technique to a directional dark matter search. In particular, we present re…
▽ More
The addition of O2 to gas mixtures in time projection chambers containing CS2 has recently been shown to produce multiple negative ions that travel at slightly different velocities. This allows a measurement of the absolute position of ionising events in the z (drift) direction. In this work, we apply the z-fiducialisation technique to a directional dark matter search. In particular, we present results from a 46.3 live-day source-free exposure of the DRIFT-IId detector run in this completely new mode. With full-volume fiducialisation, we have achieved the first background-free operation of a directional detector. The resulting exclusion curve for spin-dependent WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better than our previous work. We describe the automated analysis used here, and argue that detector upgrades, implemented after the acquisition of these data, will bring an additional factor of >3 improvement in the near future.
△ Less
Submitted 23 July, 2015; v1 submitted 28 October, 2014;
originally announced October 2014.
-
Radon in the DRIFT-II directional dark matter TPC: emanation, detection and mitigation
Authors:
J. B. R. Battat,
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. R. Fox,
J. -L. Gauvreau,
M. Gold,
L. J. Harmon,
J. L. Harton,
J. M. Landers,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Pipe,
M. Robinson,
S. W. Sadler,
A. Scarff,
D. P. Snowden-Ifft,
N. J. C. Spooner
, et al. (4 additional authors not shown)
Abstract:
Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils of radon daughter isotopes…
▽ More
Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils of radon daughter isotopes, which can mimic the signal expected from WIMP interactions. Presented here are results of measurements of radon emanation from detector materials in the 1 metre cubed DRIFT-II directional dark matter gas time projection chamber experiment. Construction and operation of a radon emanation facility for this work is described, along with an analysis to continuously monitor DRIFT data for the presence of internal 222Rn and 218Po. Applying this analysis to historical DRIFT data, we show how systematic substitution of detector materials for alternatives, selected by this device for low radon emanation, has resulted in a factor of ~10 reduction in internal radon rates. Levels are found to be consistent with the sum from separate radon emanation measurements of the internal materials and also with direct measurement using an attached alpha spectrometer. The current DRIFT detector, DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 μBq/l with current analysis efficiency, potentially opening up DRIFT technology as a new tool for sensitive radon assay of materials.
△ Less
Submitted 25 August, 2014; v1 submitted 15 July, 2014;
originally announced July 2014.
-
Measurement of Optical Attenuation in Acrylic Light Guides for a Dark Matter Detector
Authors:
M. Bodmer,
N. Phan,
M. Gold,
D. Loomba,
J. A. J. Matthews,
K. Rielage
Abstract:
Acrylic is a common material used in dark matter and neutrino detectors for light guides, transparent vessels, and neutron shielding, creating an intermediate medium between the target volume and photodetectors. Acrylic has low absorption within the visible spectrum and has a high capture cross section for neutrons. The natural radioactivity in photodetectors is a major source of background neutro…
▽ More
Acrylic is a common material used in dark matter and neutrino detectors for light guides, transparent vessels, and neutron shielding, creating an intermediate medium between the target volume and photodetectors. Acrylic has low absorption within the visible spectrum and has a high capture cross section for neutrons. The natural radioactivity in photodetectors is a major source of background neutrons for low background detectors making the use of acrylic attractive for shielding and background reduction. To test the optical properties of acrylic we measured the transmittance and attenuation length of fourteen samples of acrylic from four different manufacturers. Samples were evaluated at five different wavelengths between 375 nm and 632 nm. We found that all samples had excellent transmittance at wavelengths greater than 550 nm. Transmittance was found to decrease below 550 nm. As expected, UV-absorbing samples showed a sharp decrease in transmittance below 425 nm compared to UV-transmitting samples. We report attenuation lengths for the three shortest wavelengths for comparison and discuss how the acrylic was evaluated for use in the MiniCLEAN single-phase dark matter detector.
△ Less
Submitted 15 January, 2014; v1 submitted 23 October, 2013;
originally announced October 2013.
-
Long-term study of backgrounds in the DRIFT-II directional dark matter experiment
Authors:
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. R. Fox,
J. -L. Gauvreau,
M. Gold,
L. J. Harmon,
J. Harton,
R. Lafler,
J. M. Landers,
R. Lauer,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Pipe,
M. Robinson,
S. Sadler,
A. Scarff,
D. P. Snowden-Ifft
, et al. (4 additional authors not shown)
Abstract:
Low-pressure gas Time Projection Chambers being developed for directional dark matter searches offer a technology with strong particle identification capability combined with the potential to produce a definitive detection of Galactic Weakly Interacting Massive Particle (WIMP) dark matter. A source of events able to mimic genuine WIMP-induced nuclear recoil tracks arises in such experiments from t…
▽ More
Low-pressure gas Time Projection Chambers being developed for directional dark matter searches offer a technology with strong particle identification capability combined with the potential to produce a definitive detection of Galactic Weakly Interacting Massive Particle (WIMP) dark matter. A source of events able to mimic genuine WIMP-induced nuclear recoil tracks arises in such experiments from the decay of radon gas inside the vacuum vessel. The recoils that result from associated daughter nuclei are termed Radon Progeny Recoils (RPRs). We present here experimental data from a long-term study using the DRIFT-II directional dark matter experiment at the Boulby Underground Laboratory of the RPRs, and other backgrounds that are revealed by relaxing the normal cuts that are applied to WIMP search data. By detailed examination of event classes in both spatial and time coordinates using 5.5 years of data, we demonstrate the ability to determine the origin of 4 specific background populations and describe development of new technology and mitigation strategies to suppress them.
△ Less
Submitted 12 May, 2014; v1 submitted 21 July, 2013;
originally announced July 2013.
-
The Pierre Auger Observatory V: Enhancements
Authors:
The Pierre Auger Collaboration,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. F. M. Albuquerque,
D. Allard,
I. Allekotte,
J. Allen,
P. Allison,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
A. Aminaei,
L. Anchordoqui,
S. Andringa,
T. Antičić,
A. Anzalone,
C. Aramo,
E. Arganda,
F. Arqueros,
H. Asorey,
P. Assis,
J. Aublin,
M. Ave,
M. Avenier
, et al. (471 additional authors not shown)
Abstract:
Ongoing and planned enhancements of the Pierre Auger Observatory
Ongoing and planned enhancements of the Pierre Auger Observatory
△ Less
Submitted 24 July, 2011;
originally announced July 2011.
-
The Pierre Auger Observatory IV: Operation and Monitoring
Authors:
The Pierre Auger Collaboration,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. F. M. Albuquerque,
D. Allard,
I. Allekotte,
J. Allen,
P. Allison,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
A. Aminaei,
L. Anchordoqui,
S. Andringa,
T. Antičić,
A. Anzalone,
C. Aramo,
E. Arganda,
F. Arqueros,
H. Asorey,
P. Assis,
J. Aublin,
M. Ave,
M. Avenier
, et al. (471 additional authors not shown)
Abstract:
Technical reports on operations and monitoring of the Pierre Auger Observatory
Technical reports on operations and monitoring of the Pierre Auger Observatory
△ Less
Submitted 24 July, 2011;
originally announced July 2011.
-
Measurement of the Aerosol Phase Function at the Pierre Auger Observatory
Authors:
S. Y. BenZvi,
B. M. Connolly,
J. A. J. Matthews,
M. Prouza,
E. F. Visbal,
S. Westerhoff
Abstract:
Air fluorescence detectors measure the energy of ultra-high energy cosmic rays by collecting fluorescence light emitted from nitrogen molecules along the extensive air shower cascade. To ensure a reliable energy determination, the light signal needs to be corrected for atmospheric effects, which not only attenuate the signal, but also produce a non-negligible background component due to scattere…
▽ More
Air fluorescence detectors measure the energy of ultra-high energy cosmic rays by collecting fluorescence light emitted from nitrogen molecules along the extensive air shower cascade. To ensure a reliable energy determination, the light signal needs to be corrected for atmospheric effects, which not only attenuate the signal, but also produce a non-negligible background component due to scattered Cherenkov light and multiple-scattered light. The correction requires regular measurements of the aerosol attenuation length and the aerosol phase function, defined as the probability of light scattered in a given direction. At the Pierre Auger Observatory in Malargue, Argentina, the phase function is measured on an hourly basis using two Aerosol Phase Function (APF) light sources. These sources direct a UV light beam across the field of view of the fluorescence detectors; the phase function can be extracted from the image of the shots in the fluorescence detector cameras. This paper describes the design, current status, standard operation procedure, and performance of the APF system at the Pierre Auger Observatory.
△ Less
Submitted 2 July, 2007; v1 submitted 2 April, 2007;
originally announced April 2007.