-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Performance of the LHCb RICH detectors during LHC Run 2
Authors:
R. Calabrese,
M. Fiorini,
E. Luppi,
L. Minzoni,
I. Slazyk,
L. Tomassetti,
M. Bartolini,
R. Cardinale,
F. Fontanelli,
A. Petrolini,
A. Pistone,
M. Calvi,
C. Matteuzzi,
A. Lupato,
G. Simi,
M. Kucharczyk,
B. Malecki,
M. Witek,
S. Benson,
M. Blago,
G. Cavallero,
A. Contu,
C. D'Ambrosio,
C. Frei,
T. Gys
, et al. (57 additional authors not shown)
Abstract:
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. The particle identification performance is evaluated with data and found to satisfy the requirements of the physics programme.
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. The particle identification performance is evaluated with data and found to satisfy the requirements of the physics programme.
△ Less
Submitted 26 May, 2022;
originally announced May 2022.
-
Results on Multiple Coulomb Scattering from 12 and 20 GeV electrons on Carbon targets
Authors:
G. Abbiendi,
J. Bernhard,
F. Betti,
M. Bonanomi,
C. M. Carloni Calame,
M. Garattini,
Y. Gavrikov,
G. Hall,
F. Iacoangeli,
F. Ignatov,
M. Incagli,
V. Ivanchenko,
F. Ligabue,
T. O. James,
U. Marconi,
C. Matteuzzi,
M. Passera,
M. Pesaresi,
F. Piccinini,
R. N. Pilato,
F. Pisani,
A. Principe,
W. Scandale,
R. Tenchini,
G. Venanzoni
Abstract:
Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm thickness carbon targets have been studied with high-resolution silicon microstrip detectors of the UA9 apparatus at the H8 line at CERN. Comparison of the scattering angle between data and GEANT4 simulation shows excellent agreement in the core of the distributions leaving some residual disagreement in the tails.
Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm thickness carbon targets have been studied with high-resolution silicon microstrip detectors of the UA9 apparatus at the H8 line at CERN. Comparison of the scattering angle between data and GEANT4 simulation shows excellent agreement in the core of the distributions leaving some residual disagreement in the tails.
△ Less
Submitted 19 April, 2020; v1 submitted 28 May, 2019;
originally announced May 2019.
-
Single photon detection with SiPMs irradiated up to 10$^{14}$ cm$^{-2}$ 1-MeV-equivalent neutron fluence
Authors:
M. Calvi,
P. Carniti,
C. Gotti,
C. Matteuzzi,
G. Pessina
Abstract:
Silicon photomultipliers (SiPM) are solid state light detectors with sensitivity to single photons. Their use in high energy physics experiments, and in particular in ring imaging Cherenkov (RICH) detectors, is hindered by their poor tolerance to radiation. At room temperature the large increase in dark count rate makes single photon detection practically impossible already at 10$^{11}$ cm$^{-2}$…
▽ More
Silicon photomultipliers (SiPM) are solid state light detectors with sensitivity to single photons. Their use in high energy physics experiments, and in particular in ring imaging Cherenkov (RICH) detectors, is hindered by their poor tolerance to radiation. At room temperature the large increase in dark count rate makes single photon detection practically impossible already at 10$^{11}$ cm$^{-2}$ 1-MeV-equivalent neutron fluence. The neutron fluences foreseen by many subdetectors to be operated at the high luminosity LHC range up to 10$^{14}$ cm$^{-2}$ 1-MeV-equivalent. In this paper we present the effects of such high neutron fluences on Hamamatsu and SensL SiPMs of different cell size. The advantage of annealing at high temperature (up to 175 $^{\circ}$C) is discussed. We demonstrate that, after annealing, operation at the single photon level with a SiPM irradiated up to 10$^{14}$ cm$^{-2}$ 1-MeV-equivalent neutron fluence is possible at cryogenic temperature (77 K) with a dark count rate below 1~kHz.
△ Less
Submitted 15 January, 2019; v1 submitted 18 May, 2018;
originally announced May 2018.
-
Test of the photon detection system for the LHCb RICH Upgrade in a charged particle beam
Authors:
M. K. Baszczyk,
M. Benettoni,
R. Calabrese,
R. Cardinale,
P. Carniti,
L. Cassina,
G. Cavallero,
L. Cojocariu,
A. Cotta Ramusino,
C. D'Ambrosio,
P. A. Dorosz,
S. Easo,
S. Eisenhardt,
M. Fiorini,
C. Frei,
S. Gambetta,
V. Gibson,
C. Gotti,
N. Harnew,
J. He,
F. Keizer,
W. Kucewicz,
F. Maciuc,
M. Maino,
R. Malaguti
, et al. (16 additional authors not shown)
Abstract:
The LHCb detector will be upgraded to make more efficient use of the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb detector for particle identification. In this paper we describe the setup and the results of tests in a charged particle beam, carried out to assess prototypes of the upgraded opto…
▽ More
The LHCb detector will be upgraded to make more efficient use of the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb detector for particle identification. In this paper we describe the setup and the results of tests in a charged particle beam, carried out to assess prototypes of the upgraded opto-electronic chain from the Multi-Anode PMT photosensor to the readout and data acquisition system.
△ Less
Submitted 10 October, 2016;
originally announced October 2016.
-
Characterization of the Hamamatsu H12700A-03 and R12699-03 multi-anode photomultiplier tubes
Authors:
Marta Calvi,
Paolo Carniti,
Lorenzo Cassina,
Claudio Gotti,
Matteo Maino,
Clara Matteuzzi,
Gianluigi Pessina
Abstract:
The H12700 is a novel 64-channel 52 $\times$ 52 mm$^2$ square Multi-Anode PhotoMultiplier Tube (MaPMT) produced by Hamamatsu. Its characteristics make this device suitable for high energy physics applications, such as in Ring Imaging Cherenkov (RICH) detectors. Hamamatsu provides the H12700 tube with an embedded socket connecting the anodes to the output pins and including an active voltage divide…
▽ More
The H12700 is a novel 64-channel 52 $\times$ 52 mm$^2$ square Multi-Anode PhotoMultiplier Tube (MaPMT) produced by Hamamatsu. Its characteristics make this device suitable for high energy physics applications, such as in Ring Imaging Cherenkov (RICH) detectors. Hamamatsu provides the H12700 tube with an embedded socket connecting the anodes to the output pins and including an active voltage divider. A second device version, the R12699, is also available and differs from the former by the absence of the socket. This paper describes a complete characterization of both models, starting from the standard operating parameters (single photon spectra, average gain, anode uniformity and dark current value), investigating in detail the cross-talk effect among neighbouring pixels and considering the behaviour in critical environment conditions, such as in presence of a static magnetic field up to 100 Gauss, at different operating temperatures and after long exposure to intense light.
△ Less
Submitted 5 October, 2015; v1 submitted 13 June, 2015;
originally announced June 2015.
-
Characterization of the Hamamatsu R11265-103-M64 multi-anode photomultiplier tube
Authors:
L. Cadamuro,
M. Calvi,
L. Cassina,
A. Giachero,
C. Gotti,
B. Khanji,
M. Maino,
C. Matteuzzi,
G. Pessina
Abstract:
The aim of this paper is to fully characterize the new multi-anode photomultiplier tube R11265-103-M64, produced by Hamamatsu. Its high effective active area (77%), its pixel size, the low dark signal rate and the capability to detect single photon signals make this tube suitable for an application in high energy physics, such as for RICH detectors. Four tubes and two different bias voltage divide…
▽ More
The aim of this paper is to fully characterize the new multi-anode photomultiplier tube R11265-103-M64, produced by Hamamatsu. Its high effective active area (77%), its pixel size, the low dark signal rate and the capability to detect single photon signals make this tube suitable for an application in high energy physics, such as for RICH detectors. Four tubes and two different bias voltage dividers have been tested. The results of a standard characterization of the gain and the anode uniformity, the dark signal rate, the cross-talk and the device behaviour as a function of temperature have been studied. The behaviour of the tube is studied in a longitudinal magnetic field up to 100 Gauss. Shields made of a high permeability material are also investigated. The deterioration of the device performance due to long time operation at intense light exposure is studied. A quantitative analysis of the variation of the gain and the dark signals rate due to the aging is described.
△ Less
Submitted 13 March, 2014;
originally announced March 2014.
-
Performance of the LHCb RICH detector at the LHC
Authors:
M. Adinolfi,
G. Aglieri Rinella,
E. Albrecht,
T. Bellunato,
S. Benson,
T. Blake,
C. Blanks,
S. Brisbane,
N. H. Brook,
M. Calvi,
B. Cameron,
R. Cardinale,
L. Carson,
A. Contu,
M. Coombes,
C. D'Ambrosio,
S. Easo,
U. Egede,
S. Eisenhardt,
E. Fanchini,
C. Fitzpatrick,
F. Fontanelli,
R. Forty,
C. Frei,
P. Gandini
, et al. (72 additional authors not shown)
Abstract:
The LHCb experiment has been taking data at the Large Hadron Collider (LHC) at CERN since the end of 2009. One of its key detector components is the Ring-Imaging Cherenkov (RICH) system. This provides charged particle identification over a wide momentum range, from 2-100 GeV/c. The operation and control software, and online monitoring of the RICH system are described. The particle identification p…
▽ More
The LHCb experiment has been taking data at the Large Hadron Collider (LHC) at CERN since the end of 2009. One of its key detector components is the Ring-Imaging Cherenkov (RICH) system. This provides charged particle identification over a wide momentum range, from 2-100 GeV/c. The operation and control software, and online monitoring of the RICH system are described. The particle identification performance is presented, as measured using data from the LHC. Excellent separation of hadronic particle types (pion, kaon and proton) is achieved.
△ Less
Submitted 17 September, 2013; v1 submitted 28 November, 2012;
originally announced November 2012.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.