-
A diffuse scattering model of ultracold neutrons on wavy surfaces
Authors:
S. Imajo,
H. Akatsuka,
K. Hatanaka,
T. Higuchi,
G. Ichikawa,
S. Kawasaki,
M. Kitaguchi,
R. Mammei,
R. Matsumiya,
K. Mishima,
R. Picker,
W. Schreyer,
H. M. Shimizu
Abstract:
Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore d…
▽ More
Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore developed a scattering model for UCN in which scattering from random surface waviness with a size larger than the UCN wavelength is described by a microfacet Bidirectional Reflectance Distribution Function model (mf-BRDF model), and scattering from smaller structures by the Lambert's cosine law (Lambert model). For the surface waviness, we used the statistical distribution of surface slope measured by an atomic force microscope on a sample piece of guide tube as input of the model. This model was used to describe UCN transmission experiments conducted at the pulsed UCN source at J-PARC. In these experiments, a UCN beam collimated to a divergence angle smaller than $\pm 6^{\circ}$ was directed into a guide tube with a mean-square roughness of 6.4 nm to 17 nm at an oblique angle, and the UCN transport performance and its time-of-flight distribution were measured while changing the angle of incidence. The mf-BRDF model combined with the Lambert model with scattering probability $p_{L} = 0.039\pm0.003$ reproduced the experimental results well. We have thus established a procedure to evaluate the characteristics of UCN guide tubes with a surface roughness of approximately 10 nm.
△ Less
Submitted 30 July, 2023; v1 submitted 27 March, 2023;
originally announced March 2023.
-
Estimated performance of the TRIUMF ultracold neutron source and electric dipole moment apparatus
Authors:
Steve Sidhu,
Wolfgang Schreyer,
Sean Vanbergen,
Shinsuke Kawasaki,
Ryohei Matsumiya,
Takahiro Okamura,
Ruediger Picker
Abstract:
Searches for the permanent electric dipole moment of the neutron (nEDM) provide strong constraints on theories beyond the Standard Model of particle physics.
The TUCAN collaboration is constructing a source for ultracold neutrons (UCN) and an apparatus to search for the nEDM at TRIUMF, Vancouver, Canada.
In this work, we estimate that the spallation-driven UCN source based on a superfluid heli…
▽ More
Searches for the permanent electric dipole moment of the neutron (nEDM) provide strong constraints on theories beyond the Standard Model of particle physics.
The TUCAN collaboration is constructing a source for ultracold neutrons (UCN) and an apparatus to search for the nEDM at TRIUMF, Vancouver, Canada.
In this work, we estimate that the spallation-driven UCN source based on a superfluid helium converter will provide $(1.38\pm0.02) \times 10^7$ polarized UCN at a density of $217\pm3$~UCN/cm$^3$ to a room-temperature EDM experiment per fill.
With $(1.51\pm0.02) \times 10^6$ neutrons detected after the Ramsey cycle, the statistical sensitivity for an nEDM search per storage cycle will be $(1.94\pm0.06) \times 10^{-25}\,e$cm (1$σ$).
The goal sensitivity of $10^{-27}\,e$cm (1$σ$) can be reached within $280\pm16$ measurement days.
△ Less
Submitted 23 January, 2023; v1 submitted 30 November, 2022;
originally announced December 2022.
-
The Precision nEDM Measurement with UltraCold Neutrons at TRIUMF
Authors:
Ryohei Matsumiya,
Hiroaki Akatsuka,
Chris P. Bidinosti,
Charles A. Davis,
Beatrice Franke,
Derek Fujimoto,
Michael T. W. Gericke,
Pietro Giampa,
Robert Golub,
Sean Hansen-Romu,
Kichiji Hatanaka,
Tomohiro Hayamizu,
Takashi Higuchi,
Go Ichikawa,
Sohei Imajo,
Blair Jamieson,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Wolfgang Klassen,
Emma Klemets,
Akira Konaka,
Elie Korkmaz,
Ekaterina Korobkina,
Florian Kuchler,
Maedeh Lavvaf
, et al. (23 additional authors not shown)
Abstract:
The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are develo** a new high-intensity ultracold neutron (UCN) source using su…
▽ More
The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are develo** a new high-intensity ultracold neutron (UCN) source using super-thermal UCN production in superfluid helium (He-II) and a nEDM spectrometer. The current development status of them is reported in this article.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
Study of Thin Iron Films for Polarization Analysis of Ultracold Neutrons
Authors:
Hiroaki Akatsuka,
Takashi Higuchi,
Sean Hansen-Romu,
Kichiji Hatanaka,
Tomohiro Hayamizu,
Masahiro Hino,
Go Ichikawa,
Sohei Imajo,
Blair Jamieson,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Ryohei Matsumiya,
Kenji Mishima
Abstract:
The TUCAN (TRIUMF Ultra-Cold Advanced Neutron) collaboration aims to search for the neutron electric dipole moment (nEDM) with unprecedented precision. One of the essential elements for the nEDM measurement is a polarization analyzer of ultracold neutrons (UCNs), whose main component is a magnetized thin iron film. Several thin iron films were deposited on aluminum and silicon ubstrates and were c…
▽ More
The TUCAN (TRIUMF Ultra-Cold Advanced Neutron) collaboration aims to search for the neutron electric dipole moment (nEDM) with unprecedented precision. One of the essential elements for the nEDM measurement is a polarization analyzer of ultracold neutrons (UCNs), whose main component is a magnetized thin iron film. Several thin iron films were deposited on aluminum and silicon ubstrates and were characterized by vibrating sample magnetometry and cold-neutron reflectometry. A magnetic field required to saturate the iron film is $\sim$12 kA/m for those on the aluminum substrates and 6.4 kA/m for the silicon substrates. The magnetic potential of the iron films on the Si substrate was estimated to be 2 T by the neutron reflectometry, which is sufficient performance for an UCN polarization analyzer of the nEDM measurement.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
A fast-switching magnet serving a spallation-driven ultracold neutron source
Authors:
S. Ahmed,
E. Altiere,
T. Andalib,
M. J. Barnes,
B. Bell,
C. P. Bidinosti,
Y. Bylinsky,
J. Chak,
M. Das,
C. A. Davis,
F. Fischer,
B. Franke,
M. T. W. Gericke,
P. Giampa,
M. Hahn,
S. Hansen-Romu,
K. Hatanaka,
T. Hayamizu,
B. Jamieson,
D. Jones,
K. Katsika,
S. Kawasaki,
T. Kikawa,
W. Klassen,
A. Konaka
, et al. (25 additional authors not shown)
Abstract:
A fast-switching, high-repetition-rate magnet and power supply have been developed for and operated at TRIUMF, to deliver a proton beam to the new ultracold neutron (UCN) facility. The facility possesses unique operational requirements: a time-averaged beam current of 40~$μ$A with the ability to switch the beam on or off for several minutes. These requirements are in conflict with the typical oper…
▽ More
A fast-switching, high-repetition-rate magnet and power supply have been developed for and operated at TRIUMF, to deliver a proton beam to the new ultracold neutron (UCN) facility. The facility possesses unique operational requirements: a time-averaged beam current of 40~$μ$A with the ability to switch the beam on or off for several minutes. These requirements are in conflict with the typical operation mode of the TRIUMF cyclotron which delivers nearly continuous beam to multiple users. To enable the creation of the UCN facility, a beam-sharing arrangement with another facility was made. The beam sharing is accomplished by the fast-switching (kicker) magnet which is ramped in 50~$μ$s to a current of 193~A, held there for approximately 1~ms, then ramped down in the same short period of time. This achieves a 12~mrad deflection which is sufficient to switch the proton beam between the two facilities. The kicker magnet relies on a high-current, low-inductance coil connected to a fast-switching power supply that is based on insulated-gate bipolar transistors (IGBTs). The design and performance of the kicker magnet system and initial beam delivery results are reported.
△ Less
Submitted 11 August, 2019; v1 submitted 21 May, 2019;
originally announced May 2019.
-
A beamline for fundamental neutron physics at TRIUMF
Authors:
S. Ahmed,
T. Andalib,
M. J. Barnes,
C. B. Bidinosti,
Y. Bylinsky,
J. Chak,
M. Das,
C. A. Davis,
B. Franke,
M. T. W. Gericke,
P. Giampa,
M. Hahn,
S. Hansen-Romu,
K. Hatanaka,
B. Jamieson,
D. Jones,
K. Katsika,
S. Kawasaki,
W. Klassen,
A. Konaka,
E. Korkmaz,
F. Kuchler,
L. Kurchaninov,
M. Lang,
L. Lee
, et al. (22 additional authors not shown)
Abstract:
This article describes the new primary proton beamline 1U at TRIUMF. The purpose of this beamline is to produce ultracold neutrons (UCN) for fundamental-physics experiments. It delivers up to 40 microA of 480 MeV protons from the TRIUMF cyclotron to a tungsten spallation target and uses a fast kicker to share the beam between the Center for Molecular and Materials Science and UCN. The beamline has…
▽ More
This article describes the new primary proton beamline 1U at TRIUMF. The purpose of this beamline is to produce ultracold neutrons (UCN) for fundamental-physics experiments. It delivers up to 40 microA of 480 MeV protons from the TRIUMF cyclotron to a tungsten spallation target and uses a fast kicker to share the beam between the Center for Molecular and Materials Science and UCN. The beamline has been successfully commissioned and operated with a beam current up to 10 microA, facilitating first large-scale UCN production in Canada.
△ Less
Submitted 26 December, 2018; v1 submitted 1 October, 2018;
originally announced October 2018.
-
First ultracold neutrons produced at TRIUMF
Authors:
S. Ahmed,
E. Altiere,
T. Andalib,
B. Bell,
C. P. Bidinosti,
E. Cudmore,
M. Das,
C. A. Davis,
B. Franke,
M. Gericke,
P. Giampa,
P. Gnyp,
S. Hansen-Romu,
K. Hatanaka,
T. Hayamizu,
B. Jamieson,
D. Jones,
S. Kawasaki,
T. Kikawa,
M. Kitaguchi,
W. Klassen,
A. Konaka,
E. Korkmaz,
F. Kuchler,
M. Lang
, et al. (28 additional authors not shown)
Abstract:
We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this so…
▽ More
We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this source. The corresponding ultracold-neutron density in the whole production and guide volume is 5.3$\,$cm$^{-3}$. The storage lifetime of ultracold neutrons in the source was initially 37$\,$s and dropped to 24$\,$s during the eighteen days of operation. During continuous irradiation of the spallation target, we were able to detect a sustained ultracold-neutron rate of up to 1500$\,$s$^{-1}$. Simulations of UCN production, UCN transport, temperature-dependent UCN yield, and temperature-dependent storage lifetime show excellent agreement with the experimental data and confirm that the ultracold-neutron-upscattering rate in superfluid helium is proportional to $T^7$.
△ Less
Submitted 16 December, 2018; v1 submitted 10 September, 2018;
originally announced September 2018.