A facility for radiation hardness studies based on a medical cyclotron
Authors:
John Anders,
Saverio Braccini,
Tommaso Stefano Carzaniga,
Pierluigi Casolaro,
Meghranjana Chatterjee,
Gaia Dellepiane,
Laura Franconi,
Lea Halser,
Armin Ilg,
Isidre Mateu,
Federico Meloni,
Claudia Merlassino,
Antonio Miucci,
Roman Müller,
Marco Rimoldi,
Michele Weber
Abstract:
The development of instrumentation for operation in high-radiation environments represents a challenge in various research fields, particularly in particle physics experiments and space missions, and drives an ever-increasing demand for irradiation facilities dedicated to radiation hardness studies. Depending on the application, different needs arise in terms of particle type, energy and dose rate…
▽ More
The development of instrumentation for operation in high-radiation environments represents a challenge in various research fields, particularly in particle physics experiments and space missions, and drives an ever-increasing demand for irradiation facilities dedicated to radiation hardness studies. Depending on the application, different needs arise in terms of particle type, energy and dose rate. In this article, we present a versatile installation based on a medical cyclotron located at the Bern University Hospital (Inselspital), which is used as a controlled 18-MeV proton source. This accelerator is used for daily production of medical radioisotopes, as well as for multidisciplinary research, thanks to a 6.5-meter long beam transfer line that terminates in an independent bunker, dedicated only to scientific activities. The facility offers a wide range of proton fluxes, due to an adjustable beam current from approximately 10 pA to the micro-ampere range, together with a series of steering and focusing magnets along the beamline that allow for the beam spot to be focused down to a few mm^2. The beamline can be instrumented with a variety of beam monitoring detectors, collimators, and beam current measurement devices to precisely control the irradiation conditions. The facility also hosts a well equipped laboratory dedicated to the characterisation of samples after irradiation. An experimental validation of the irradiation setup, with proton fluxes ranging from $5\times10^9$ cm$^{-2}$s$^{-1}$ to $4\times10^{11}$ cm$^{-2}$s$^{-1}$, is reported in this article.
△ Less
Submitted 22 March, 2022; v1 submitted 11 January, 2022;
originally announced January 2022.
-
Radiation-induced effects in glass windows for optical readout GEM-based detectors
Authors:
A. Maia Oliveira,
S. Braccini,
P. Casolaro,
N. Heracleous,
J. Leidner,
I. Mateu,
F. Murtas,
M. Silari
Abstract:
In this paper we present irradiation measurements performed to select a transparent anode substrate that best meets the requirements of an optical readout for a novel detector, the LaGEMPix. The modification of the optical properties of the material due to proton irradiation were studied in soda-lime, fused quartz and fused silica glasses coated with an Indium Tin Oxide layer. The irradiations wer…
▽ More
In this paper we present irradiation measurements performed to select a transparent anode substrate that best meets the requirements of an optical readout for a novel detector, the LaGEMPix. The modification of the optical properties of the material due to proton irradiation were studied in soda-lime, fused quartz and fused silica glasses coated with an Indium Tin Oxide layer. The irradiations were performed using the research Beam Transfer Line (BTL) of the IBA Cyclone 18 MeV cyclotron of the Bern University Hospital (Inselspital). We recorded visible scintillation light generated by proton irradiation in the soda-lime and fused quartz samples. We also investigated the darkening of these three glasses and observed radiation-induced colour centres in the soda-lime glass sample. The optical transmission spectra of the samples were measured before and after irradiation. Reductions of 45%, 1% and 0.4% were observed for soda-lime glass, fused quartz and fused silica, respectively (with an associated error of 0.25%). We conclude that the best option for our specific application is the fused silica substrate, which will be the transparent anode for the next generation of the LaGEMPix detector.
△ Less
Submitted 8 June, 2021;
originally announced June 2021.
-
Experimental Determination of Proton Hardness Factors at Several Irradiation Facilities
Authors:
P. Allport,
F. Bogelspacher,
K. Bruce,
R. Canavan,
A. Dierlamm,
L. Gonella,
P. Knights,
I. Mateu,
M. Moll,
K. Nikolopoulos,
B. Phoenix,
T. Price,
L. Ram,
F. Ravotti,
C. Simpson-Allsop,
C. Wood
Abstract:
The scheduled High Luminosity upgrade of the CERN Large Hadron Collider presents new challenges in terms of radiation hardness. As a consequence, campaigns to qualify the radiation hardness of detector sensors and components are undertaken worldwide. The effects of irradiation with beams of different particle species and energy, aiming to assess displacement damage in semiconductor devices, are co…
▽ More
The scheduled High Luminosity upgrade of the CERN Large Hadron Collider presents new challenges in terms of radiation hardness. As a consequence, campaigns to qualify the radiation hardness of detector sensors and components are undertaken worldwide. The effects of irradiation with beams of different particle species and energy, aiming to assess displacement damage in semiconductor devices, are communicated in terms of the equivalent 1 MeV neutron fluence, using the hardness factor for the conversion. In this work, the hardness factors for protons at three different kinetic energies have been measured by analysing the I-V and C-V characteristics of reverse biased diodes, pre- and post-irradiation. The sensors were irradiated at the MC40 Cyclotron of the University of Birmingham, the cyclotron at the Karlsruhe Institute of Technology, and the IRRAD proton facility at CERN, with the respective measured proton hardness factors being: 2.1 +/- 0.5 for 24 MeV, 2.2 +/- 0.4 for 23 MeV, and 0.62 +/- 0.04 for 23 GeV. The hardness factors currently used in these three facilities are in agreement with the presented measurements.
△ Less
Submitted 12 November, 2019; v1 submitted 8 August, 2019;
originally announced August 2019.
-
Deep Diffused Avalanche Photodiodes for Charged Particles Timing
Authors:
M. Centis Vignali,
P. Dias De Almeida,
L. Franconi,
M. Gallinaro,
Y. Gurimskaya,
B. Harrop,
W. Holmkvist,
C. Lu,
I. Mateu,
M. McClish,
M. Moll,
F. M. Newcomer,
S. Otero Ugobono,
S. White,
M. Wiehe
Abstract:
The upgrades of ATLAS and CMS for the High Luminosity LHC (HL-LHC) highlighted physics objects timing as a tool to resolve primary interactions within a bunch crossing. Since the expected pile-up is around 200, with an r.m.s. time spread of 180 ps, a time resolution of about 30 ps is needed. The timing detectors will experience a 1-MeV neutron equivalent fluence of about $Φ_{eq}=10^{14}$ and…
▽ More
The upgrades of ATLAS and CMS for the High Luminosity LHC (HL-LHC) highlighted physics objects timing as a tool to resolve primary interactions within a bunch crossing. Since the expected pile-up is around 200, with an r.m.s. time spread of 180 ps, a time resolution of about 30 ps is needed. The timing detectors will experience a 1-MeV neutron equivalent fluence of about $Φ_{eq}=10^{14}$ and $10^{15}$ cm$^{-2}$ for the barrel and end-cap regions, respectively. In this contribution, deep diffused Avalanche Photo Diodes (APDs) produced by Radiation Monitoring Devices are examined as candidate timing detectors for HL-LHC applications. To improve the detector's timing performance, the APDs are used to directly detect the traversing particles, without a radiator medium where light is produced. Devices with an active area of $8\times8$ mm$^2$ were characterized in beam tests. The timing performance and signal properties were measured as a function of position on the detector using a beam telescope and a microchannel plate photomultiplier (MCP-PMT). Devices with an active area of $2\times2$ mm$^2$ were used to determine the effects of radiation damage and characterized using a ps pulsed laser. These detectors were irradiated with neutrons up to $Φ_{eq}=10^{15}$ cm$^{-2}$.
△ Less
Submitted 31 July, 2019; v1 submitted 18 March, 2019;
originally announced March 2019.