-
Euclid preparation. LensMC, weak lensing cosmic shear measurement with forward modelling and Markov Chain Monte Carlo sampling
Authors:
Euclid Collaboration,
G. Congedo,
L. Miller,
A. N. Taylor,
N. Cross,
C. A. J. Duncan,
T. Kitching,
N. Martinet,
S. Matthew,
T. Schrabback,
M. Tewes,
N. Welikala,
N. Aghanim,
A. Amara,
S. Andreon,
N. Auricchio,
M. Baldi,
S. Bardelli,
R. Bender,
C. Bodendorf,
D. Bonino,
E. Branchini,
M. Brescia,
J. Brinchmann,
S. Camera
, et al. (217 additional authors not shown)
Abstract:
LensMC is a weak lensing shear measurement method developed for Euclid and Stage-IV surveys. It is based on forward modelling to deal with convolution by a point spread function with comparable size to many galaxies; sampling the posterior distribution of galaxy parameters via Markov Chain Monte Carlo; and marginalisation over nuisance parameters for each of the 1.5 billion galaxies observed by Eu…
▽ More
LensMC is a weak lensing shear measurement method developed for Euclid and Stage-IV surveys. It is based on forward modelling to deal with convolution by a point spread function with comparable size to many galaxies; sampling the posterior distribution of galaxy parameters via Markov Chain Monte Carlo; and marginalisation over nuisance parameters for each of the 1.5 billion galaxies observed by Euclid. The scientific performance is quantified through high-fidelity images based on the Euclid Flagship simulations and emulation of the Euclid VIS images; realistic clustering with a mean surface number density of 250 arcmin$^{-2}$ ($I_{\rm E}<29.5$) for galaxies, and 6 arcmin$^{-2}$ ($I_{\rm E}<26$) for stars; and a diffraction-limited chromatic point spread function with a full width at half maximum of $0.^{\!\prime\prime}2$ and spatial variation across the field of view. Objects are measured with a density of 90 arcmin$^{-2}$ ($I_{\rm E}<26.5$) in 4500 deg$^2$. The total shear bias is broken down into measurement (our main focus here) and selection effects (which will be addressed elsewhere). We find: measurement multiplicative and additive biases of $m_1=(-3.6\pm0.2)\times10^{-3}$, $m_2=(-4.3\pm0.2)\times10^{-3}$, $c_1=(-1.78\pm0.03)\times10^{-4}$, $c_2=(0.09\pm0.03)\times10^{-4}$; a large detection bias with a multiplicative component of $1.2\times10^{-2}$ and an additive component of $-3\times10^{-4}$; and a measurement PSF leakage of $α_1=(-9\pm3)\times10^{-4}$ and $α_2=(2\pm3)\times10^{-4}$. When model bias is suppressed, the obtained measurement biases are close to Euclid requirement and largely dominated by undetected faint galaxies ($-5\times10^{-3}$). Although significant, model bias will be straightforward to calibrate given the weak sensitivity.
△ Less
Submitted 1 May, 2024;
originally announced May 2024.
-
The LHCb ultra-fast simulation option, Lamarr: design and validation
Authors:
Lucio Anderlini,
Matteo Barbetti,
Simone Capelli,
Gloria Corti,
Adam Davis,
Denis Derkach,
Nikita Kazeev,
Artem Maevskiy,
Maurizio Martinelli,
Sergei Mokonenko,
Benedetto Gianluca Siddi,
Zehua Xu
Abstract:
Detailed detector simulation is the major consumer of CPU resources at LHCb, having used more than 90% of the total computing budget during Run 2 of the Large Hadron Collider at CERN. As data is collected by the upgraded LHCb detector during Run 3 of the LHC, larger requests for simulated data samples are necessary, and will far exceed the pledged resources of the experiment, even with existing fa…
▽ More
Detailed detector simulation is the major consumer of CPU resources at LHCb, having used more than 90% of the total computing budget during Run 2 of the Large Hadron Collider at CERN. As data is collected by the upgraded LHCb detector during Run 3 of the LHC, larger requests for simulated data samples are necessary, and will far exceed the pledged resources of the experiment, even with existing fast simulation options. An evolution of technologies and techniques to produce simulated samples is mandatory to meet the upcoming needs of analysis to interpret signal versus background and measure efficiencies. In this context, we propose Lamarr, a Gaudi-based framework designed to offer the fastest solution for the simulation of the LHCb detector. Lamarr consists of a pipeline of modules parameterizing both the detector response and the reconstruction algorithms of the LHCb experiment. Most of the parameterizations are made of Deep Generative Models and Gradient Boosted Decision Trees trained on simulated samples or alternatively, where possible, on real data. Embedding Lamarr in the general LHCb Gauss Simulation framework allows combining its execution with any of the available generators in a seamless way. Lamarr has been validated by comparing key reconstructed quantities with Detailed Simulation. Good agreement of the simulated distributions is obtained with two-order-of-magnitude speed-up of the simulation phase.
△ Less
Submitted 22 September, 2023;
originally announced September 2023.
-
APEIRON: composing smart TDAQ systems for high energy physics experiments
Authors:
Roberto Ammendola,
Andrea Biagioni,
Carlotta Chiarini,
Andrea Ciardiello,
Paolo Cretaro,
Ottorino Frezza,
Francesca Lo Cicero,
Alessandro Lonardo,
Michele Martinelli,
Pier Stanislao Paolucci,
Cristian Rossi,
Francesco Simula,
Matteo Turisini,
Piero Vicini
Abstract:
APEIRON is a framework encompassing the general architecture of a distributed heterogeneous processing platform and the corresponding software stack, from the low level device drivers up to the high level programming model. The framework is designed to be efficiently used for studying, prototy** and deploying smart trigger and data acquisition (TDAQ) systems for high energy physics experiments.
APEIRON is a framework encompassing the general architecture of a distributed heterogeneous processing platform and the corresponding software stack, from the low level device drivers up to the high level programming model. The framework is designed to be efficiently used for studying, prototy** and deploying smart trigger and data acquisition (TDAQ) systems for high energy physics experiments.
△ Less
Submitted 3 July, 2023;
originally announced July 2023.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Progress report on the online processing upgrade at the NA62 experiment
Authors:
M. Turisini,
R. Ammendola,
A. Biagioni,
A. Ciardiello,
P. Cretaro,
O. Frezza,
G. Lamanna,
F. Lo Cicero,
A. Lonardo,
M. Martinelli,
R. Piandani,
D. Soldi,
P. Vicini
Abstract:
A new FPGA-based low-level trigger processor has been installed at the NA62 experiment. It is intended to extend the features of its predecessor due to a faster interconnection technology and additional logic resources available on the new platform. With the aim of improving trigger selectivity and exploring new architectures for complex trigger computation, a GPU system has been developed and a n…
▽ More
A new FPGA-based low-level trigger processor has been installed at the NA62 experiment. It is intended to extend the features of its predecessor due to a faster interconnection technology and additional logic resources available on the new platform. With the aim of improving trigger selectivity and exploring new architectures for complex trigger computation, a GPU system has been developed and a neural network on FPGA is in progress. They both process data streams from the Ring Imaging Cherenkov detector of the experiment to extract in real time high level features for the trigger logic. Description of the systems, latest developments and design flows are reported in this paper.
△ Less
Submitted 8 February, 2022;
originally announced February 2022.
-
Architectural improvements and technological enhancements for the APEnet+ interconnect system
Authors:
R. Ammendola,
A. Biagioni,
O. Frezza,
A. Lonardo,
F. Lo Cicero,
M. Martinelli,
P. S. Paolucci,
E. Pastorelli,
D. Rossetti,
F. Simula,
L. Tosoratto,
P. Vicini
Abstract:
The APEnet+ board delivers a point-to-point, low-latency, 3D torus network interface card. In this paper we describe the latest generation of APEnet NIC, APEnet v5, integrated in a PCIe Gen3 board based on a state-of-the-art, 28 nm Altera Stratix V FPGA. The NIC features a network architecture designed following the Remote DMA paradigm and tailored to tightly bind the computing power of modern GPU…
▽ More
The APEnet+ board delivers a point-to-point, low-latency, 3D torus network interface card. In this paper we describe the latest generation of APEnet NIC, APEnet v5, integrated in a PCIe Gen3 board based on a state-of-the-art, 28 nm Altera Stratix V FPGA. The NIC features a network architecture designed following the Remote DMA paradigm and tailored to tightly bind the computing power of modern GPUs to the communication fabric. For the APEnet v5 board we show characterizing figures as achieved bandwidth and BER obtained by exploiting new high performance ALTERA transceivers and PCIe Gen3 compliancy.
△ Less
Submitted 4 January, 2022;
originally announced January 2022.
-
Decomposing spatial mode superpositions with a triangular optical cavity
Authors:
G. H. dos Santos,
D. C. Salles,
M. G. Damaceno,
B. Teles de Menezes,
C. Corso,
M. Martinelli,
P. H. Souto Ribeiro,
R. Medeiros de araújo
Abstract:
We demonstrate that a triangular cavity can operate as an efficient discriminator for Hermite-Gaussian optical modes. The process is applied to distinct fields produced by a Spatial Light Modulator, decomposing the generated paraxial field onto a basis of modes defined by the resonant modes of the optical cavity. We also present a proposal for the realization of a mode sorter based on a sequence o…
▽ More
We demonstrate that a triangular cavity can operate as an efficient discriminator for Hermite-Gaussian optical modes. The process is applied to distinct fields produced by a Spatial Light Modulator, decomposing the generated paraxial field onto a basis of modes defined by the resonant modes of the optical cavity. We also present a proposal for the realization of a mode sorter based on a sequence of these cavities, without the need for optical isolation. We discuus its possible applications in sensitive measurements and distribution of information in optical systems. The high purity of the process should enable the use at the level of quantum information sharing.
△ Less
Submitted 9 April, 2021;
originally announced April 2021.
-
Design and performance of the LHCb trigger and full real-time reconstruction in Run 2 of the LHC
Authors:
R. Aaij,
S. Akar,
J. Albrecht,
M. Alexander,
A. Alfonso Albero,
S. Amerio,
L. Anderlini,
P. d'Argent,
A. Baranov,
W. Barter,
S. Benson,
D. Bobulska,
T. Boettcher,
S. Borghi,
E. E. Bowen,
L. Brarda,
C. Burr,
J. -P. Cachemiche,
M. Calvo Gomez,
M. Cattaneo,
H. Chanal,
M. Chapman,
M. Chebbi,
M. Chefdeville,
P. Ciambrone
, et al. (116 additional authors not shown)
Abstract:
The LHCb collaboration has redesigned its trigger to enable the full offline detector reconstruction to be performed in real time. Together with the real-time alignment and calibration of the detector, and a software infrastructure to make persistent the high-level physics objects produced during real-time processing, this redesign enabled the widespread deployment of real-time analysis during Run…
▽ More
The LHCb collaboration has redesigned its trigger to enable the full offline detector reconstruction to be performed in real time. Together with the real-time alignment and calibration of the detector, and a software infrastructure to make persistent the high-level physics objects produced during real-time processing, this redesign enabled the widespread deployment of real-time analysis during Run 2. We describe the design of the Run 2 trigger and real-time reconstruction, and present data-driven performance measurements for a representative sample of LHCb's physics programme.
△ Less
Submitted 25 June, 2019; v1 submitted 27 December, 2018;
originally announced December 2018.
-
Skin optical attenuation coefficient modulation with arterial pulsation
Authors:
Matheus Bigatão Martinelli,
Christian Tolentino Dominguez,
Luciano Bachmann,
George C. Cardoso
Abstract:
Video plethysmographic (vPPG) signals arise from subtle color modulations in reflected light. vPPG signals can be used to monitor vital signs remotely in a noninvasive manner. We have used optical coherence tomography (OCT) imaging to find whether vPPG signals may result from skin optical properties being modulated by arterial transmural pressure propagation. Our results confirm this hypothesis an…
▽ More
Video plethysmographic (vPPG) signals arise from subtle color modulations in reflected light. vPPG signals can be used to monitor vital signs remotely in a noninvasive manner. We have used optical coherence tomography (OCT) imaging to find whether vPPG signals may result from skin optical properties being modulated by arterial transmural pressure propagation. Our results confirm this hypothesis and show that the attenuation coefficient of even the most external, non-vascularized skin, changes at the same frequency as the arterial pulsation.
△ Less
Submitted 27 October, 2018;
originally announced October 2018.
-
Probing light forces on cold atoms by noise correlation spectroscopy
Authors:
K. Theophilo,
A. Kumar,
H. M. Florez,
C. González-Arciniegas,
P. Nussenzveig,
M. Martinelli
Abstract:
Enhanced sensitivity in electromagnetically induced transparency (EIT) can be obtained by the use of noise correlation spectroscopy between the fields involved in the process. Here, we investigate EIT in a cold ($< 1$ mK) rubidium vapor and demonstrate sensitivity to detect weak light-induced forces on the atoms. A theoretical model is developed and shows good agreement with our measurements, enab…
▽ More
Enhanced sensitivity in electromagnetically induced transparency (EIT) can be obtained by the use of noise correlation spectroscopy between the fields involved in the process. Here, we investigate EIT in a cold ($< 1$ mK) rubidium vapor and demonstrate sensitivity to detect weak light-induced forces on the atoms. A theoretical model is developed and shows good agreement with our measurements, enabling the attribution of the observed effects to the coupling of the atomic states to their motion. The effects remain unnoticed on the measurement of the mean fields but are clearly manifest in their correlations.
△ Less
Submitted 8 August, 2018;
originally announced August 2018.
-
Information Gain in Cosmology: From the Discovery of Expansion to Future Surveys
Authors:
Marco Raveri,
Matteo Martinelli,
Gongbo Zhao,
Yuting Wang
Abstract:
Facing the advent of the next generation cosmological surveys we present a method to forecast knowledge gain on cosmological models. We propose this as a well defined and general tool to quantify the performance of different experiments in relation to different theoretical models. In particular, the assessment of experimental performance will benefit enormously from the fact that this method is in…
▽ More
Facing the advent of the next generation cosmological surveys we present a method to forecast knowledge gain on cosmological models. We propose this as a well defined and general tool to quantify the performance of different experiments in relation to different theoretical models. In particular, the assessment of experimental performance will benefit enormously from the fact that this method is invariant under re-parametrization of the model. We apply this to future surveys and compare expected knowledge advancements to the most relevant experiments performed over the history of modern cosmology. When considering the standard cosmological model, we show that it will rapidly reach knowledge saturation in the near future and forthcoming improvements will not match the past ones. On the contrary, we find that new observations have the potential for unprecedented knowledge jumps when extensions of the standard scenario are considered.
△ Less
Submitted 20 June, 2016;
originally announced June 2016.
-
GPU-based Real-time Triggering in the NA62 Experiment
Authors:
R. Ammendola,
A. Biagioni,
P. Cretaro,
S. Di Lorenzo,
R. Fantechi,
M. Fiorini,
O. Frezza,
G. Lamanna,
F. Lo Cicero,
A. Lonardo,
M. Martinelli,
I. Neri,
P. S. Paolucci,
E. Pastorelli,
R. Piandani,
L. Pontisso,
D. Rossetti,
F. Simula,
M. Sozzi,
P. Vicini
Abstract:
Over the last few years the GPGPU (General-Purpose computing on Graphics Processing Units) paradigm represented a remarkable development in the world of computing. Computing for High-Energy Physics is no exception: several works have demonstrated the effectiveness of the integration of GPU-based systems in high level trigger of different experiments. On the other hand the use of GPUs in the low le…
▽ More
Over the last few years the GPGPU (General-Purpose computing on Graphics Processing Units) paradigm represented a remarkable development in the world of computing. Computing for High-Energy Physics is no exception: several works have demonstrated the effectiveness of the integration of GPU-based systems in high level trigger of different experiments. On the other hand the use of GPUs in the low level trigger systems, characterized by stringent real-time constraints, such as tight time budget and high throughput, poses several challenges. In this paper we focus on the low level trigger in the CERN NA62 experiment, investigating the use of real-time computing on GPUs in this synchronous system. Our approach aimed at harvesting the GPU computing power to build in real-time refined physics-related trigger primitives for the RICH detector, as the the knowledge of Cerenkov rings parameters allows to build stringent conditions for data selection at trigger level. Latencies of all components of the trigger chain have been analyzed, pointing out that networking is the most critical one. To keep the latency of data transfer task under control, we devised NaNet, an FPGA-based PCIe Network Interface Card (NIC) with GPUDirect capabilities. For the processing task, we developed specific multiple ring trigger algorithms to leverage the parallel architecture of GPUs and increase the processing throughput to keep up with the high event rate. Results obtained during the first months of 2016 NA62 run are presented and discussed.
△ Less
Submitted 13 June, 2016;
originally announced June 2016.
-
Perturbative approach in the frequency domain for the intensity correlation spectrum at electromagnetically induced transparency
Authors:
H. M. Florez,
C. González,
M. Martinelli
Abstract:
Correlation spectroscopy has been proposed as a spectroscopic technique for measuring the coherence between the ground states in electromagnetically induced transparency (EIT). While in time domain the steep dispersion in EIT condition accounts for the robustness of the correlation linewidth against power broadening, such physical insight was not directly established in the frequency domain. We pr…
▽ More
Correlation spectroscopy has been proposed as a spectroscopic technique for measuring the coherence between the ground states in electromagnetically induced transparency (EIT). While in time domain the steep dispersion in EIT condition accounts for the robustness of the correlation linewidth against power broadening, such physical insight was not directly established in the frequency domain. We propose a perturbative approach to describe the correlation spectroscopy of two noisy lasers coupled to a $Λ$-transition in cold atoms, leading to EIT. Such approach leads to an analytical expression that maps the intensity correlation directly in terms of the absorption and dispersion of the light fields. Low and high perturbative regimes are investigated and demonstrate that, for coherent light sources, the first oder term in perturbation expansion represents a sufficient description for the correlation. Sidebands resonances are also observed, showing the richness of the frequency domain approach.
△ Less
Submitted 31 March, 2016; v1 submitted 30 March, 2016;
originally announced March 2016.
-
Correlation spectroscopy in cold atoms: light sidebands resonances in electromagnetically induced transparency condition
Authors:
H. M. Florez,
A. Kumar,
K. Theophilo,
P. Nussenzveig,
M. Martinelli
Abstract:
The correlation spectroscopy has been successfully employed in the measurement of the intrinsic linewidth of electromagnetically induced transparency (EIT) in time and frequency domain. We study the role of the sidebands of the intense fields in the measured spectra, analyzing the information that can be recovered working with different analysis frequencies. In this case, the non-zero one-photon d…
▽ More
The correlation spectroscopy has been successfully employed in the measurement of the intrinsic linewidth of electromagnetically induced transparency (EIT) in time and frequency domain. We study the role of the sidebands of the intense fields in the measured spectra, analyzing the information that can be recovered working with different analysis frequencies. In this case, the non-zero one-photon detuning appears as a necessary condition for spectrally resolving the sideband resonances in the correlation coefficient. Our experimental findings are supported by the perturbative model defined in the frequency domain.
△ Less
Submitted 19 August, 2015;
originally announced August 2015.
-
NaNet: a Low-Latency, Real-Time, Multi-Standard Network Interface Card with GPUDirect Features
Authors:
A. Lonardo,
F. Ameli,
R. Ammendola,
A. Biagioni,
O. Frezza,
G. Lamanna,
F. Lo Cicero,
M. Martinelli,
P. S. Paolucci,
E. Pastorelli,
L. Pontisso,
D. Rossetti,
F. Simeone,
F. Simula,
M. Sozzi,
L. Tosoratto,
P. Vicini
Abstract:
While the GPGPU paradigm is widely recognized as an effective approach to high performance computing, its adoption in low-latency, real-time systems is still in its early stages.
Although GPUs typically show deterministic behaviour in terms of latency in executing computational kernels as soon as data is available in their internal memories, assessment of real-time features of a standard GPGPU s…
▽ More
While the GPGPU paradigm is widely recognized as an effective approach to high performance computing, its adoption in low-latency, real-time systems is still in its early stages.
Although GPUs typically show deterministic behaviour in terms of latency in executing computational kernels as soon as data is available in their internal memories, assessment of real-time features of a standard GPGPU system needs careful characterization of all subsystems along data stream path.
The networking subsystem results in being the most critical one in terms of absolute value and fluctuations of its response latency.
Our envisioned solution to this issue is NaNet, a FPGA-based PCIe Network Interface Card (NIC) design featuring a configurable and extensible set of network channels with direct access through GPUDirect to NVIDIA Fermi/Kepler GPU memories.
NaNet design currently supports both standard - GbE (1000BASE-T) and 10GbE (10Base-R) - and custom - 34~Gbps APElink and 2.5~Gbps deterministic latency KM3link - channels, but its modularity allows for a straightforward inclusion of other link technologies.
To avoid host OS intervention on data stream and remove a possible source of jitter, the design includes a network/transport layer offload module with cycle-accurate, upper-bound latency, supporting UDP, KM3link Time Division Multiplexing and APElink protocols.
After NaNet architecture description and its latency/bandwidth characterization for all supported links, two real world use cases will be presented: the GPU-based low level trigger for the RICH detector in the NA62 experiment at CERN and the on-/off-shore data link for KM3 underwater neutrino telescope.
△ Less
Submitted 13 June, 2014;
originally announced June 2014.
-
Power-Broadening-Free Correlation Spectroscopy in Cold Atoms
Authors:
H. M. Florez,
L. S. Cruz,
M. H. G. de Miranda,
R. A. de Oliveira,
J. W. R. Tabosa,
M. Martinelli,
D. Felinto
Abstract:
We report a detailed investigation on the properties of correlation spectra for cold atoms under the condition of Electromagnetically Induced Transparency (EIT). We describe the transition in the system from correlation to anti-correlation as the intensity of the fields increases. Such transition occurs for laser frequencies around the EIT resonance, which is characterized by a correlation peak. T…
▽ More
We report a detailed investigation on the properties of correlation spectra for cold atoms under the condition of Electromagnetically Induced Transparency (EIT). We describe the transition in the system from correlation to anti-correlation as the intensity of the fields increases. Such transition occurs for laser frequencies around the EIT resonance, which is characterized by a correlation peak. The transition point between correlation and anti-correlation is independent of power broadening and provides directly the ground-state coherence time. We introduce a method to extract in real time the correlation spectra of the system. The experiments were done in two distinct magneto-optical traps (MOT), one for cesium and the other for rubidium atoms, employing different detection schemes. A simplified theory is introduced assuming three-level atoms in $Λ$ configuration interacting with a laser with stochastic phase fluctuations, providing a good agreement with the experimental observations.
△ Less
Submitted 4 August, 2013;
originally announced August 2013.
-
Application of vertex and mass constraints in track-based alignment
Authors:
J. Amoraal,
J. Blouw,
S. Blusk,
S. Borghi,
M. Cattaneo,
N. Chiapolini,
G. Conti,
M. Deissenroth,
F. Dupertuis,
R. van der Eijk,
V. Fave,
M. Gersabeck,
A. Hicheur,
W. Hulsbergen,
D. Hutchcroft,
A. Kozlinskiy,
R. W. Lambert,
F. Maciuc,
R. Marki,
M. Martinelli,
M. Merk,
M. Needham,
L. Nicolas,
J. Palacios,
C. Parkes
, et al. (14 additional authors not shown)
Abstract:
The software alignment of planar tracking detectors using samples of charged particle trajectories may lead to global detector distortions that affect vertex and momentum resolution. We present an alignment procedure that constrains such distortions by making use of samples of decay vertices reconstructed from two or more trajectories and putting constraints on their invariant mass. We illustrate…
▽ More
The software alignment of planar tracking detectors using samples of charged particle trajectories may lead to global detector distortions that affect vertex and momentum resolution. We present an alignment procedure that constrains such distortions by making use of samples of decay vertices reconstructed from two or more trajectories and putting constraints on their invariant mass. We illustrate the method by using a sample of invariant-mass constrained vertices from D^0 --> K^- pi^+ decays to remove a curvature bias in the LHCb spectrometer.
△ Less
Submitted 28 March, 2013; v1 submitted 19 July, 2012;
originally announced July 2012.
-
The quest for three-color entanglement: experimental investigation of new multipartite quantum correlations
Authors:
K. N. Cassemiro,
A. S. Villar,
M. Martinelli,
P. Nussenzveig
Abstract:
We experimentally investigate quadrature correlations between pump, signal, and idler fields in an above-threshold optical parametric oscillator. We observe new quantum correlations among the pump and signal or idler beams, as well as among the pump and a combined quadrature of signal and idler beams. A further investigation of unforeseen classical noise observed in this system is presented, whi…
▽ More
We experimentally investigate quadrature correlations between pump, signal, and idler fields in an above-threshold optical parametric oscillator. We observe new quantum correlations among the pump and signal or idler beams, as well as among the pump and a combined quadrature of signal and idler beams. A further investigation of unforeseen classical noise observed in this system is presented, which hinders the observation of the recently predicted tripartite entanglement. In spite of this noise, current results approach the limit required to demonstrate three-color entanglement.
△ Less
Submitted 21 September, 2007;
originally announced September 2007.
-
A new concept of (open) TE011 cylindrical cavity
Authors:
G. Annino,
M. Cassettari,
M. Martinelli
Abstract:
The confinement properties of the open structure formed crossing a circular waveguide perpendicular to a parallel-plate waveguide are discussed, highlighting the fundamental differences with respect to the common high-frequency resonators. Among the electromagnetic modes trapped at the intersection region of the two waveguides, the TE011 one appears as the most appropriate for high-frequency app…
▽ More
The confinement properties of the open structure formed crossing a circular waveguide perpendicular to a parallel-plate waveguide are discussed, highlighting the fundamental differences with respect to the common high-frequency resonators. Among the electromagnetic modes trapped at the intersection region of the two waveguides, the TE011 one appears as the most appropriate for high-frequency applications. The experimental characterization of this mode is described in detail, investigating the response of a millimeter wave configuration resonating at 281 GHz, which shows state-of-the-art performances. The properties of the TE011 mode are studied in terms of the geometry, calculating the mode chart and the related quality factor and power-to-field conversion efficiency. The mode chart is then determined for configurations including a sample holder, in which one of the component waveguides is filled with a low-loss dielectric material. The TE011 mode reveals in general remarkable merit figures, as well as a significant stability with respect to the geometrical imperfections and to the insertion of a sample holder. The obtained results show that the proposed single-mode resonator competes with the standard cavities in terms of performance, versatility, and simplicity.
△ Less
Submitted 6 December, 2006; v1 submitted 20 March, 2006;
originally announced March 2006.
-
Properties of trapped electromagnetic modes in coupled waveguides
Authors:
G. Annino,
H. Yashiro,
M. Cassettari,
M. Martinelli
Abstract:
The existence of trapped modes in coupled electromagnetic waveguides is experimentally investigated for configurations with different degrees of symmetry supporting hybrid modes. The occurrence of confined solutions in such open geometries is proven to be much more general than demonstrated so far, as predicted by Goldstone and Jaffe [J. Goldstone and R. L. Jaffe, Phys. Rev. B 45, 14100 (1992)].…
▽ More
The existence of trapped modes in coupled electromagnetic waveguides is experimentally investigated for configurations with different degrees of symmetry supporting hybrid modes. The occurrence of confined solutions in such open geometries is proven to be much more general than demonstrated so far, as predicted by Goldstone and Jaffe [J. Goldstone and R. L. Jaffe, Phys. Rev. B 45, 14100 (1992)]. The identification of the observed modes is based on the numerical modeling of the relative vector fields. The experimental results evidence as an increasing aperture of the configuration can improve the confinement of the mode instead of generating additional leakage channels. In particular, long-lived trapped modes can be easily obtained in geometries with a relevant degree of aperture. Their resonance parameters can compete with those of standard close cavities working at millimeter wavelengths. The role of the symmetry on the properties of these trapped modes is discussed in detail.
△ Less
Submitted 16 December, 2005; v1 submitted 1 September, 2005;
originally announced September 2005.
-
High frequency single-mode resonators for EPR spectroscopy enabling rotations of the sample about two orthogonal axes
Authors:
G. Annino,
M. Cassettari,
M. Fittipaldi,
M. Martinelli
Abstract:
A novel single-mode resonant structure which enables the rotation of the sample about two orthogonal axes is investigated in view of electron paramagnetic resonance applications. The proposed solution is based on cylindrical nonradiative resonators laterally loaded by the sample holder. The resulting structure can still operate in nonradiative regime, although no longer rotationally invariant. T…
▽ More
A novel single-mode resonant structure which enables the rotation of the sample about two orthogonal axes is investigated in view of electron paramagnetic resonance applications. The proposed solution is based on cylindrical nonradiative resonators laterally loaded by the sample holder. The resulting structure can still operate in nonradiative regime, although no longer rotationally invariant. These theoretical predictions, based on symmetry considerations, are confirmed by means of a finite element numerical modelling. Theoretical and computational results are then substantiated by experimental investigations at millimeter wavelengths. As a result, a single-mode resonator which enables all the relevant rotations of the sample is demonstrated at millimeter wavelengths for the first time. In this resonator the intensity of the microwave field on the sample and its orientation with respect to the static magnetic field can be kept constant during the rotations. Therefore, a complete characterization of anisotropic systems is possible at the highest sensitivity, without the need of split-coil magnets. Possible applications at very high frequencies are discussed.
△ Less
Submitted 22 April, 2005;
originally announced April 2005.
-
Axially open nonradiative structures: an example of single-mode resonator based on the sample holder
Authors:
G. Annino,
M. Cassettari,
M. Martinelli
Abstract:
The concept of nonradiative dielectric resonator is generalized in order to include axially open configurations having rotational invariance. The resulting additional nonradiative conditions are established for the different resonance modes on the basis of their azimuthal modal index. An approximate chart of the allowed dielectric and geometrical parameters for the TE011 mode is given. A practic…
▽ More
The concept of nonradiative dielectric resonator is generalized in order to include axially open configurations having rotational invariance. The resulting additional nonradiative conditions are established for the different resonance modes on the basis of their azimuthal modal index. An approximate chart of the allowed dielectric and geometrical parameters for the TE011 mode is given. A practical realization of the proposed device based on commercial fused quartz tubes is demonstrated at millimeter wavelengths, together with simple excitation and tuning mechanisms. The observed resonances are characterized in their basic parameters, as well as in the field distribution by means of a finite element method. The predictions of the theoretical analysis are well confirmed, both in the general behaviour and in the expected quality factors. The resulting device, in which the sample holder acts itself as single-mode resonating element, combines an extreme ease of realization with state-of-the-art performances. The general benefits of the proposed open single-mode resonators are finally discussed.
△ Less
Submitted 1 February, 2005;
originally announced February 2005.
-
Open nonradiative cavities as millimeter wave single-mode resonators
Authors:
G. Annino,
M. Cassettari,
M. Martinelli
Abstract:
Open single-mode metallic cavities operating in nonradiative configurations are proposed and demonstrated. Starting from well-known dielectric resonators, possible nonradiative cavities have been established; their behavior on the fundamental TE011 mode has been predicted on the basis of general considerations. As a result, very efficient confinement properties are expected for a wide variety of…
▽ More
Open single-mode metallic cavities operating in nonradiative configurations are proposed and demonstrated. Starting from well-known dielectric resonators, possible nonradiative cavities have been established; their behavior on the fundamental TE011 mode has been predicted on the basis of general considerations. As a result, very efficient confinement properties are expected for a wide variety of open structures having rotational invariance. Test cavities realized having in mind practical millimeter wave constraints have been characterized at microwave frequencies. The field distribution of some relevant configurations has been modeled by means of a finite-element numerical method. The obtained results confirm the expected high performances on widely open configurations. A possible excitation of the proposed resonators exploiting their nonradiative character is discussed, and the resulting overall ease of realization enlightened in view of millimeter wave employments.
△ Less
Submitted 3 October, 2005; v1 submitted 30 August, 2004;
originally announced August 2004.
-
Orbital angular momentum exchange in an optical parametric oscillator
Authors:
M. Martinelli,
J. A. O. Huguenin,
P. Nussenzveig,
A. Z. Khoury
Abstract:
We present a study of orbital angular momentum transfer from pump to down-converted beams in a type-II Optical Parametric Oscillator. Cavity and anisotropy effects are investigated and demostrated to play a central role in the transverse mode dynamics. While the idler beam can oscillate in a Laguerre-Gauss mode, the crystal birefringence induces an astigmatic effect in the signal beam that preve…
▽ More
We present a study of orbital angular momentum transfer from pump to down-converted beams in a type-II Optical Parametric Oscillator. Cavity and anisotropy effects are investigated and demostrated to play a central role in the transverse mode dynamics. While the idler beam can oscillate in a Laguerre-Gauss mode, the crystal birefringence induces an astigmatic effect in the signal beam that prevents the resonance of such mode.
△ Less
Submitted 1 March, 2004;
originally announced March 2004.
-
Noise spectroscopy of non-linear magneto optical resonances in Rb vapor
Authors:
M. Martinelli,
P. Valente,
H. Failache,
D. Felinto,
L. S. Cruz,
P. Nussenzveig,
A. Lezama
Abstract:
Nonlinear magneto-optical (NMO) resonances occurring for near-zero magnetic field are studied in Rb vapor using light-noise spectroscopy. With a balanced detection polarimeter, we observe high contrast variations of the noise power (at fixed analysis frequency) carried by diode laser light resonant with the 5S$_{1/2}(F=2) \to 5$P$_{1/2}(F=1) $ transition of $^{87}$Rb and transmitted through a ru…
▽ More
Nonlinear magneto-optical (NMO) resonances occurring for near-zero magnetic field are studied in Rb vapor using light-noise spectroscopy. With a balanced detection polarimeter, we observe high contrast variations of the noise power (at fixed analysis frequency) carried by diode laser light resonant with the 5S$_{1/2}(F=2) \to 5$P$_{1/2}(F=1) $ transition of $^{87}$Rb and transmitted through a rubidium vapor cell, as a function of magnetic field $B$. A symmetric resonance doublet of anti-correlated noise is observed for orthogonal polarizations around $B=0 $ as a manifestation of ground state coherence. We also observe sideband noise resonances when the magnetic field produces an atomic Larmor precession at a frequency corresponding to one half of the analysis frequency. The resonances on the light fluctuations are the consequence of phase to amplitude noise conversion owing to nonlinear coherence effects in the response of the atomic medium to the fluctuating field. A theoretical model (derived from linearized Bloch equations) is presented that reproduces the main qualitative features of the experimental signals under simple assumptions.
△ Less
Submitted 9 December, 2003; v1 submitted 15 October, 2003;
originally announced October 2003.
-
Study On Planar Whispering Gallery Dielectric Resonators. II. A Multiple-Band Device
Authors:
G. Annino,
M. Cassettari,
M. Martinelli
Abstract:
The basic theory underlying the realization of simple multiple-band non-homogeneous dielectric resonators, whose spectral response is the overlap of single-resonator frequency bands, is developed exploiting a general approach discussed in the previous companion paper. The limit frequencies of the proposed devices, given only by the dielectric properties of the involved materials, can differ in p…
▽ More
The basic theory underlying the realization of simple multiple-band non-homogeneous dielectric resonators, whose spectral response is the overlap of single-resonator frequency bands, is developed exploiting a general approach discussed in the previous companion paper. The limit frequencies of the proposed devices, given only by the dielectric properties of the involved materials, can differ in principle by several decades. Experimental confirmations have been obtained on a composite structure built up with teflon and polyethylene; as predicted by the theory, the overall band includes frequencies which range about from 20 GHz to more than 400 GHz, when high frequency resonances are selectively excited. The localization of the higher frequency radiation between the positive steps of the dielectric constant, which is the basic properties of these non-homogeneous resonators, has been experimentally verified by map** the electromagnetic field intensity. Possible applications of multiple-band Whispering Gallery dielectric resonators are finally outlined.
△ Less
Submitted 5 March, 2002;
originally announced March 2002.
-
Study On Planar Whispering Gallery Dielectric Resonators. I. General Properties
Authors:
G. Annino,
M. Cassettari,
M. Martinelli
Abstract:
Several basic properties of homogeneous planar Whispering Gallery dielectric resonators are investigated through a general approach. In particular the values for the minimum and maximum allowed radius, defined by irradiation and dielectric losses, respectively, are obtained in terms of the complex dielectric constant of the involved media. The same approach is employed in the analysis of the lim…
▽ More
Several basic properties of homogeneous planar Whispering Gallery dielectric resonators are investigated through a general approach. In particular the values for the minimum and maximum allowed radius, defined by irradiation and dielectric losses, respectively, are obtained in terms of the complex dielectric constant of the involved media. The same approach is employed in the analysis of the limit allowed frequencies of a fixed family of mode, leading to the definition of the "ideal" frequency band. The role of the transverse mode is then discussed, and the "effective" frequency band is introduced and determined both in simple disc and circular ring resonators. The extension of the effective band is limited at least by a factor 3, in terms of decades, in comparison to the extension of the ideal one; this limitation, due to the presence of transverse modes, can be overcome using suitably designed non-homogeneous resonators, as discussed in a following companion paper.
△ Less
Submitted 5 March, 2002;
originally announced March 2002.
-
Complex Response Function of Magnetic Resonance Spectrometers
Authors:
G. Annino,
M. Cassettari,
M. Fittipaldi,
M. Martinelli
Abstract:
A vectorial analysis of magnetic resonance spectrometers, based on traveling wave resonators and including the reference arm and the automatic control of frequency, has been developed. The proposed model, valid also for stationary wave resonators, gives the response function of the spectrometer for any working condition, including scalar detectors with arbitrary response law and arbitrary excita…
▽ More
A vectorial analysis of magnetic resonance spectrometers, based on traveling wave resonators and including the reference arm and the automatic control of frequency, has been developed. The proposed model, valid also for stationary wave resonators, gives the response function of the spectrometer for any working condition, including scalar detectors with arbitrary response law and arbitrary excitation frequency. The purely dispersive and purely absorptive linear responses are discussed in detail for different scalar detectors. The developed approach allows for optimizing the performances of the spectrometer and for obtaining the intrinsic lineshape of the sample in a very broad range of working conditions. More complex setups can be modeled following the proposed scheme.
△ Less
Submitted 27 August, 2002; v1 submitted 15 February, 2002;
originally announced February 2002.
-
Ultra-low threshold CW Triply Resonant OPO in the near infrared using Periodically Poled Lithium Niobate
Authors:
M. Martinelli,
K. S. Zhang,
T. Coudreau,
A. Maitre,
C. Fabre
Abstract:
We have operated a CW triply resonant OPO using a PPLN crystal pumped by a Nd:YAG laser at 1.06 micron and generating signal and idler modes in the 2-2.3 micron range. The OPO was operated stably in single mode operation over large periods of time with a pump threshold as low as 500 microwatts.
We have operated a CW triply resonant OPO using a PPLN crystal pumped by a Nd:YAG laser at 1.06 micron and generating signal and idler modes in the 2-2.3 micron range. The OPO was operated stably in single mode operation over large periods of time with a pump threshold as low as 500 microwatts.
△ Less
Submitted 30 May, 2001;
originally announced May 2001.