-
LIGO operates with quantum noise below the Standard Quantum Limit
Authors:
Wenxuan Jia,
Victoria Xu,
Kevin Kuns,
Masayuki Nakano,
Lisa Barsotti,
Matthew Evans,
Nergis Mavalvala,
Rich Abbott,
Ibrahim Abouelfettouh,
Rana Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Naoki Aritomi,
Stuart Aston,
Matthew Ball,
Stefan Ballmer,
David Barker,
Beverly Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Nina Bode,
Edgard Bonilla,
Vladimir Bossilkov
, et al. (146 additional authors not shown)
Abstract:
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Stan…
▽ More
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Standard Quantum Limit (SQL). Reducing quantum noise below the SQL in gravitational-wave detectors, where photons are used to continuously measure the positions of freely falling mirrors, has been an active area of research for decades. Here we show how the LIGO A+ upgrade reduced the detectors' quantum noise below the SQL by up to 3 dB while achieving a broadband sensitivity improvement, more than two decades after this possibility was first presented.
△ Less
Submitted 22 April, 2024;
originally announced April 2024.
-
Combined Pre-Supernova Alert System with Kamland and Super-Kamiokande
Authors:
KamLAND,
Super-Kamiokande Collaborations,
:,
Seisho Abe,
Minori Eizuka,
Sawako Futagi,
Azusa Gando,
Yoshihito Gando,
Shun Goto,
Takahiko Hachiya,
Kazumi Hata,
Koichi Ichimura,
Sei Ieki,
Haruo Ikeda,
Kunio Inoue,
Koji Ishidoshiro,
Yuto Kamei,
Nanami Kawada,
Yasuhiro Kishimoto,
Masayuki Koga,
Maho Kurasawa,
Tadao Mitsui,
Haruhiko Miyake,
Daisuke Morita,
Takeshi Nakahata
, et al. (290 additional authors not shown)
Abstract:
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are ob…
▽ More
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are observed, an early warning of the upcoming core-collapse supernova can be provided. In light of this, KamLAND and Super-Kamiokande, both located in the Kamioka mine in Japan, have been monitoring pre-supernova neutrinos since 2015 and 2021, respectively. Recently, we performed a joint study between KamLAND and Super-Kamiokande on pre-supernova neutrino detection. A pre-supernova alert system combining the KamLAND detector and the Super-Kamiokande detector was developed and put into operation, which can provide a supernova alert to the astrophysics community. Fully leveraging the complementary properties of these two detectors, the combined alert is expected to resolve a pre-supernova neutrino signal from a 15 M$_{\odot}$ star within 510 pc of the Earth, at a significance level corresponding to a false alarm rate of no more than 1 per century. For a Betelgeuse-like model with optimistic parameters, it can provide early warnings up to 12 hours in advance.
△ Less
Submitted 1 July, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Currents from relativistic laser-plasma interaction as novel metrology for system stability of high-repetition-rate laser secondary sources
Authors:
Michael Ehret,
Jose Luis Henares,
Iuliana-Mariana Vladisavlevici,
Philip Bradford,
Jakub Cikhardt,
Tomas Burian,
Diego de Luis,
Rubén Hernández Martín,
Juan Hernández,
Joao Santos,
Giancarlo Gatti
Abstract:
This work shows for the first time experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser plasma interaction for laser driven secondary sources. Such currents rise in all interaction schemes where targets of any kind are charged by esca** laser-accelerated relativistic electrons. Therefore, return cur…
▽ More
This work shows for the first time experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser plasma interaction for laser driven secondary sources. Such currents rise in all interaction schemes where targets of any kind are charged by esca** laser-accelerated relativistic electrons. Therefore, return currents can be used as a metrological online tool in the optimization of many laser-driven secondary sources and for diagnosing their stability. We demonstrate the destruction free measurement of return currents at the example of a tape target system irradiated by the 1 PW VEGA3 laser at CLPU at its maximum capabilities for laser-driven ion acceleration. Such endeavour paves the ground for feedback systems that operate at the high-repetition-rate of PW-class laser systems.
△ Less
Submitted 31 January, 2024;
originally announced January 2024.
-
Influence of climate variability on the potential forage production of a mown permanent grassland in the French Massif Central
Authors:
Iñigo Gómara,
Gianni Bellocchi,
Raphaël Martin,
Belén Rodríguez-Fonseca,
Margarita Ruiz-Ramos
Abstract:
Climate Services (CS) provide support to decision makers across socio-economic sectors. In the agricultural sector, one of the most important CS applications is to provide timely and accurate yield forecasts based on climate prediction. In this study, the Pasture Simulation model (PaSim) was used to simulate, for the period 1959-2015, the forage production of a mown grassland system (Laqueuille, M…
▽ More
Climate Services (CS) provide support to decision makers across socio-economic sectors. In the agricultural sector, one of the most important CS applications is to provide timely and accurate yield forecasts based on climate prediction. In this study, the Pasture Simulation model (PaSim) was used to simulate, for the period 1959-2015, the forage production of a mown grassland system (Laqueuille, Massif Central of France) under different management conditions, with meteorological inputs extracted from the SAFRAN atmospheric database. The aim was to generate purely climate-dependent timeseries of optimal forage production, a variable that was maximized by brighter and warmer weather conditions at the grassland. A long-term increase was observed in simulated forage yield, with the 1995-2015 average being 29% higher than the 1959-1979 average. Such increase seems consistent with observed rising trends in temperature and CO2, and multi-decadal changes in incident solar radiation. At interannual timescales, sea surface temperature anomalies of the Mediterranean (MED), Tropical North Atlantic (TNA), equatorial Pacific (El Niño Southern Oscillation) and the North Atlantic Oscillation (NAO) index were found robustly correlated with annual forage yield values. Relying only on climatic predictors, we developed a stepwise statistical multi-regression model with leave-one-out cross-validation. Under specific management conditions (e.g., three annual cuts) and from one to five months in advance, the generated model successfully provided a p-value<0.01 in correlation (t-test), a root mean square error percentage (%RMSE) of 14.6% and a 71.43% hit rate predicting above/below average years in terms of forage yield collection.
△ Less
Submitted 25 January, 2024;
originally announced January 2024.
-
High-repetition-rate source of nanosecond duration kA-current pulses driven by relativistic laser pulses
Authors:
Michael Ehret,
Jakub Cikhardt,
Philip Bradford,
Iuliana-Mariana Vladisavlevici,
Tomas Burian,
Diego de Luis,
Jose Luis Henares,
Ruben Hernandez Martin,
Jon Imanol Apinaniz,
Roberto Lera,
Jose Antonio Perez-Hernandez,
Joao Jorge Santos,
Giancarlo Gatti
Abstract:
We report the first high-repetition rate generation and simultaneous characterization of nanosecond-scale return currents of kA-magnitude issued by the polarization of a target irradiated with a PW-class high-repetition-rate Ti:Sa laser system at relativistic intensities. We present experimental results obtained with the VEGA-3 laser at intensities from 5e18 - 1.3e20 W/cm2. A non-invasive inductiv…
▽ More
We report the first high-repetition rate generation and simultaneous characterization of nanosecond-scale return currents of kA-magnitude issued by the polarization of a target irradiated with a PW-class high-repetition-rate Ti:Sa laser system at relativistic intensities. We present experimental results obtained with the VEGA-3 laser at intensities from 5e18 - 1.3e20 W/cm2. A non-invasive inductive return-current monitor is adopted to measure the derivative of return-currents on the order of kA/ns and analysis methodology is developed to derive return-currents. We compare the current for copper, aluminium and Kapton targets at different laser energies. The data shows the stable production of current peaks and clear prospects for the tailoring of the pulse shape, promising for future applications in high energy density science, e.g. electromagnetic interference stress tests, high-voltage pulse response measurements, and charged particle beam lensing. We compare the target discharge of the order of hundreds of nC with theoretical predictions and a good agreement is found.
△ Less
Submitted 9 November, 2023;
originally announced November 2023.
-
A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures
Authors:
A. Erhart,
V. Wagner,
A. Wex,
C. Goupy,
D. Lhuillier,
E. Namuth,
C. Nones,
R. Rogly,
V. Savu,
M. Schwarz,
R. Strauss,
M. Vivier,
H. Abele,
G. Angloher,
A. Bento,
J. Burkhart,
L. Canonica,
F. Cappella,
N. Casali,
R. Cerulli,
A. Cruciani,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer
, et al. (37 additional authors not shown)
Abstract:
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we…
▽ More
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we developed a cryogenic muon veto equipped with wavelength shifting fibers and a silicon photo multiplier operating inside a dilution refrigerator. The achievable compactness of cryostat-internal integration is a key factor in kee** the muon rate to a minimum while maximizing coverage. The thermal and light output properties of a plastic scintillation detector were examined. We report first data on the thermal conductivity and heat capacity of the polystyrene-based scintillator UPS-923A over a wide range of temperatures extending below one Kelvin. The light output was measured down to 0.8K and observed to increase by a factor of 1.61$\pm$0.05 compared to 300K. The development of an organic plastic scintillation muon veto operating in sub-Kelvin temperature environments opens new perspectives for rare-event searches with cryogenic detectors at sites lacking substantial overburden.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
Event-by-Event Direction Reconstruction of Solar Neutrinos in a High Light-Yield Liquid Scintillator
Authors:
A. Allega,
M. R. Anderson,
S. Andringa,
J. Antunes,
M. Askins,
D. J. Auty,
A. Bacon,
J. Baker,
N. Barros,
F. Barão,
R. Bayes,
E. W. Beier,
T. S. Bezerra,
A. Bialek,
S. D. Biller,
E. Blucher,
E. Caden,
E. J. Callaghan,
M. Chen,
S. Cheng,
B. Cleveland,
D. Cookman,
J. Corning,
M. A. Cox,
R. Dehghani
, et al. (94 additional authors not shown)
Abstract:
The direction of individual $^8$B solar neutrinos has been reconstructed using the SNO+ liquid scintillator detector. Prompt, directional Cherenkov light was separated from the slower, isotropic scintillation light using time information, and a maximum likelihood method was used to reconstruct the direction of individual scattered electrons. A clear directional signal was observed, correlated with…
▽ More
The direction of individual $^8$B solar neutrinos has been reconstructed using the SNO+ liquid scintillator detector. Prompt, directional Cherenkov light was separated from the slower, isotropic scintillation light using time information, and a maximum likelihood method was used to reconstruct the direction of individual scattered electrons. A clear directional signal was observed, correlated with the solar angle. The observation was aided by a period of low primary fluor concentration that resulted in a slower scintillator decay time. This is the first time that event-by-event direction reconstruction in high light-yield liquid scintillator has been demonstrated in a large-scale detector.
△ Less
Submitted 10 April, 2024; v1 submitted 12 September, 2023;
originally announced September 2023.
-
Majorana Demonstrator Data Release for AI/ML Applications
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y. -D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
N. Fuad,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (35 additional authors not shown)
Abstract:
The enclosed data release consists of a subset of the calibration data from the Majorana Demonstrator experiment. Each Majorana event is accompanied by raw Germanium detector waveforms, pulse shape discrimination cuts, and calibrated final energies, all shared in an HDF5 file format along with relevant metadata. This release is specifically designed to support the training and testing of Artificia…
▽ More
The enclosed data release consists of a subset of the calibration data from the Majorana Demonstrator experiment. Each Majorana event is accompanied by raw Germanium detector waveforms, pulse shape discrimination cuts, and calibrated final energies, all shared in an HDF5 file format along with relevant metadata. This release is specifically designed to support the training and testing of Artificial Intelligence (AI) and Machine Learning (ML) algorithms upon our data. This document is structured as follows. Section I provides an overview of the dataset's content and format; Section II outlines the location of this dataset and the method for accessing it; Section III presents the NPML Machine Learning Challenge associated with this dataset; Section IV contains a disclaimer from the Majorana collaboration regarding the use of this dataset; Appendix A contains technical details of this data release. Please direct questions about the material provided within this release to [email protected] (A. Li).
△ Less
Submitted 14 September, 2023; v1 submitted 21 August, 2023;
originally announced August 2023.
-
Energy Calibration of Germanium Detectors for the MAJORANA DEMONSTRATOR
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (31 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR was a search for neutrinoless double-beta decay ($0νββ$) in the $^{76}$Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Research Facility (SURF) in Lead, SD. The experiment consisted of 58 germanium detectors housed in a low background shield and was calibrated once per week by deploying a $^{228}$Th line source for 1 to 2 hours. The energy scal…
▽ More
The MAJORANA DEMONSTRATOR was a search for neutrinoless double-beta decay ($0νββ$) in the $^{76}$Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Research Facility (SURF) in Lead, SD. The experiment consisted of 58 germanium detectors housed in a low background shield and was calibrated once per week by deploying a $^{228}$Th line source for 1 to 2 hours. The energy scale calibration determination for the detector array was automated using custom analysis tools. We describe the offline procedure for calibration of the Demonstrator germanium detectors, including the simultaneous fitting of multiple spectral peaks, estimation of energy scale uncertainties, and the automation of the calibration procedure.
△ Less
Submitted 3 August, 2023; v1 submitted 14 June, 2023;
originally announced June 2023.
-
Study of collision and $γ$-cascade times following neutron-capture processes in cryogenic detectors
Authors:
CRAB collaboration,
G. Soum-Sidikov,
H. Abele,
J. Burkhart,
F. Cappella,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
J-P. Crocombette,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
E. Dumonteil,
A. Erhart,
A. Giuliani,
C. Goupy,
F. Gunsing,
E. Jericha,
M. Kaznacheeva,
A. Kinast,
H. Kluck,
A. Langenkämper,
T. Lasserre
, et al. (25 additional authors not shown)
Abstract:
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay betwe…
▽ More
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay between the development in time of the de-excitation $γ$-cascade of the target nucleus and that of the associated atomic collisions in matter. We present detailed simulations coupling the FIFRELIN code for the description of the $γ$-cascades and the IRADINA code for the modelling of the fast atomic movements in matter. Nuclear recoil spectra are predicted, and made available to the community, for concrete cases of Al$_2$O$_3$, Si, Ge and CaWO$_4$ crystals exposed to a low intensity beam of thermal neutrons. We find that timing effects cause new calibration peaks to emerge in the recoil spectra and also impact the shape of the continuous recoil distribution. We discuss how they could give access to a rich physics program, spanning the accurate study of the response of cryogenic detectors in the sub-keV range, tests of solid state physics simulations and tests of nuclear models.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Triple Halide Wide Bandgap Perovskites for Efficient Indoor Photovoltaics
Authors:
Shaoyang Wang,
Paul R. Edwards,
Maged Abdelsamie,
Peter Brown,
David Webster,
Arvydas Ruseckas,
Gopika Rajan,
Ana I. S. Neves,
Robert W. Martin,
Carolin M. Sutter-Fella,
Graham A. Turnbull,
Ifor D. W. Samuel,
Lethy Krishnan Jagadamma
Abstract:
Indoor photovoltaics are receiving tremendous attention due to the continuous development of the Internet of Things (IoT). Here we report a triple anion (TA) perovskite CH3NH3PbI2.6(BrCl)0.2 with a tailored bandgap suitable for maximizing indoor light harvesting compared to methyl ammonium lead iodide CH3NH3PbI3. The best-performing TA perovskite indoor-photovoltaic device achieved a steady-state…
▽ More
Indoor photovoltaics are receiving tremendous attention due to the continuous development of the Internet of Things (IoT). Here we report a triple anion (TA) perovskite CH3NH3PbI2.6(BrCl)0.2 with a tailored bandgap suitable for maximizing indoor light harvesting compared to methyl ammonium lead iodide CH3NH3PbI3. The best-performing TA perovskite indoor-photovoltaic device achieved a steady-state power conversion efficiency (PCE) of 25.1% with an output power density of ~ 75 microW/cm2 under 1000 lux indoor illumination
(0.3 mW/cm2 irradiance). This PCE is almost 40% higher than that of equivalent CH3NH3PbI3-based devices (PCE of 17.9%). Longer carrier lifetime, reduced density of trap states and improved crystalline quality were achieved by the triple anion alloying method. The decisive role of chlorine (Cl) in the better performance of TA-based indoor photovoltaic devices was further investigated by successively reducing the Cl content and correlating it with the corresponding photovoltaic device performance. Replacing the commonly used hole transporting layer of Spiro-MeOTAD with undoped P3HT was found to significantly reduce the current-voltage hysteresis under indoor lighting conditions. A graphene-coated textile fiber-based temperature sensor was successfully powered by the triple anion perovskite indoor photovoltaic devices. The results from the present study demonstrate a novel route to maximize the PCE of halide perovskite indoor photovoltaic devices and their potential for application in the IoT industry.
△ Less
Submitted 31 January, 2023;
originally announced January 2023.
-
An Unstructured Mesh Approach to Nonlinear Noise Reduction for Coupled Systems
Authors:
Aaron Kirtland,
Jonah Botvinick-Greenhouse,
Marianne DeBrito,
Megan Osborne,
Casey Johnson,
Robert S. Martin,
Samuel J. Araki,
Daniel Q. Eckhardt
Abstract:
To address noise inherent in electronic data acquisition systems and real world sources, Araki et al. [Physica D: Nonlinear Phenomena, 417 (2021) 132819] demonstrated a grid based nonlinear technique to remove noise from a chaotic signal, leveraging a clean high-fidelity signal from the same dynamical system and ensemble averaging in multidimensional phase space. This method achieved denoising of…
▽ More
To address noise inherent in electronic data acquisition systems and real world sources, Araki et al. [Physica D: Nonlinear Phenomena, 417 (2021) 132819] demonstrated a grid based nonlinear technique to remove noise from a chaotic signal, leveraging a clean high-fidelity signal from the same dynamical system and ensemble averaging in multidimensional phase space. This method achieved denoising of a time-series data with 100% added noise but suffered in regions of low data density. To improve this grid-based method, here an unstructured mesh based on triangulations and Voronoi diagrams is used to accomplish the same task. The unstructured mesh more uniformly distributes data samples over mesh cells to improve the accuracy of the reconstructed signal. By empirically balancing bias and variance errors in selecting the number of unstructured cells as a function of the number of available samples, the method achieves asymptotic statistical convergence with known test data and reduces synthetic noise on experimental signals from Hall Effect Thrusters (HETs) with greater success than the original grid-based strategy.
△ Less
Submitted 7 September, 2022;
originally announced September 2022.
-
Charge Trap** and Energy Performance of the MAJORANA DEMONSTRATOR
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (33 additional authors not shown)
Abstract:
P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the MAJORANA DEMONSTRATOR, a neutrinoless double-beta decay experiment deploying PPC detectors enriched in $^{76}$Ge, has led to several novel improvements in…
▽ More
P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the MAJORANA DEMONSTRATOR, a neutrinoless double-beta decay experiment deploying PPC detectors enriched in $^{76}$Ge, has led to several novel improvements in the analysis of PPC signals. In this work we discuss charge trap** in PPC detectors and its effect on energy resolution. Small dislocations or impurities in the crystal lattice result in trap** of charge carriers from an ionization event of interest, attenuating the signal and degrading the measured energy. We present a modified digital pole-zero correction to the signal energy estimation that counters the effects of charge trap** and improves the energy resolution of the MAJORANA DEMONSTRATOR by approximately 30% to around 2.4 keV FWHM at 2039 keV, the $^{76}$Ge $Q$-value. An alternative approach achieving similar resolution enhancement is also presented.
△ Less
Submitted 26 April, 2023; v1 submitted 1 August, 2022;
originally announced August 2022.
-
Scintillator ageing of the T2K near detectors from 2010 to 2021
Authors:
The T2K Collaboration,
K. Abe,
N. Akhlaq,
R. Akutsu,
A. Ali,
C. Alt,
C. Andreopoulos,
M. Antonova,
S. Aoki,
T. Arihara,
Y. Asada,
Y. Ashida,
E. T. Atkin,
S. Ban,
M. Barbi,
G. J. Barker,
G. Barr,
D. Barrow,
M. Batkiewicz-Kwasniak,
F. Bench,
V. Berardi,
L. Berns,
S. Bhadra,
A. Blanchet,
A. Blondel
, et al. (333 additional authors not shown)
Abstract:
The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9--2.2\% per year. Extrapolation of the degradation…
▽ More
The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9--2.2\% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator.
△ Less
Submitted 26 July, 2022;
originally announced July 2022.
-
Interpretable Boosted Decision Tree Analysis for the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y -D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe,
R. Henning
, et al. (30 additional authors not shown)
Abstract:
The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to maximize the amount of information provided by these detectors, but the data-driven nature makes it less interpretable compared to traditional analysis. An interpretability study reveals the machine's decision-making logi…
▽ More
The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to maximize the amount of information provided by these detectors, but the data-driven nature makes it less interpretable compared to traditional analysis. An interpretability study reveals the machine's decision-making logic, allowing us to learn from the machine to feedback to the traditional analysis. In this work, we have presented the first machine learning analysis of the data from the Majorana Demonstrator; this is also the first interpretable machine learning analysis of any germanium detector experiment. Two gradient boosted decision tree models are trained to learn from the data, and a game-theory-based model interpretability study is conducted to understand the origin of the classification power. By learning from data, this analysis recognizes the correlations among reconstruction parameters to further enhance the background rejection performance. By learning from the machine, this analysis reveals the importance of new background categories to reciprocally benefit the standard Majorana analysis. This model is highly compatible with next-generation germanium detector experiments like LEGEND since it can be simultaneously trained on a large number of detectors.
△ Less
Submitted 15 February, 2023; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Final Result of the MAJORANA DEMONSTRATOR's Search for Neutrinoless Double-$β$ Decay in $^{76}$Ge
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (35 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR searched for neutrinoless double-$β$ decay ($0νββ$) of $^{76}$Ge using modular arrays of high-purity Ge detectors operated in vacuum cryostats in a low-background shield. The arrays operated with up to 40.4 kg of detectors (27.2 kg enriched to $\sim$88\% in $^{76}$Ge). From these measurements, the DEMONSTRATOR has accumulated 64.5 kg yr of enriched active exposure. With a…
▽ More
The MAJORANA DEMONSTRATOR searched for neutrinoless double-$β$ decay ($0νββ$) of $^{76}$Ge using modular arrays of high-purity Ge detectors operated in vacuum cryostats in a low-background shield. The arrays operated with up to 40.4 kg of detectors (27.2 kg enriched to $\sim$88\% in $^{76}$Ge). From these measurements, the DEMONSTRATOR has accumulated 64.5 kg yr of enriched active exposure. With a world-leading energy resolution of 2.52 keV FWHM at the 2039 keV $Q_{ββ}$ (0.12\%), we set a half-life limit of $0νββ$ in $^{76}$Ge at $T_{1/2}>8.3\times10^{25}$ yr (90\% C.L.). This provides a range of upper limits on $m_{ββ}$ of $(113-269)$ meV (90\% C.L.), depending on the choice of nuclear matrix elements.
△ Less
Submitted 10 February, 2023; v1 submitted 15 July, 2022;
originally announced July 2022.
-
The NEWS-G detector at SNOLAB
Authors:
L. Balogh,
C. Beaufort,
A. Brossard,
J. F. Caron,
M. Chapellier,
J. M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi-Fard,
Y. Deng,
K. Dering,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly,
P. Knights,
L. Kwon
, et al. (16 additional authors not shown)
Abstract:
The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve $\mathrm{sub-GeV/c^{2}}$ Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionization with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in C…
▽ More
The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve $\mathrm{sub-GeV/c^{2}}$ Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionization with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in Canada in 2021. This article details the different processes involved in the fabrication of the NEWS-G experiment. Also outlined in this paper are the mitigation strategies, measurements of radioactivity of the different components, and estimations of induced background event rates that were used to quantify and address detector backgrounds.
△ Less
Submitted 4 January, 2023; v1 submitted 30 May, 2022;
originally announced May 2022.
-
Performance of a convolutional autoencoder designed to remove electronic noise from p-type point contact germanium detector signals
Authors:
Mark R. Anderson,
Vasundhara Basu,
Ryan D. Martin,
Charlotte Z. Reed,
Noah J. Rowe,
Mehdi Shafiee,
Tianai Ye
Abstract:
We present a convolutional autoencoder to denoise pulses from a p-type point contact high-purity germanium detector similar to those used in several rare event searches. While we focus on training procedures that rely on detailed detector physics simulations, we also present implementations requiring only noisy detector pulses to train the model. We validate our autoencoder on both simulated data…
▽ More
We present a convolutional autoencoder to denoise pulses from a p-type point contact high-purity germanium detector similar to those used in several rare event searches. While we focus on training procedures that rely on detailed detector physics simulations, we also present implementations requiring only noisy detector pulses to train the model. We validate our autoencoder on both simulated data and calibration data from an $^{241}$Am source, the latter of which is used to show that the denoised pulses are statistically compatible with data pulses. We demonstrate that our denoising method is able to preserve the underlying shapes of the pulses well, offering improvement over traditional denoising methods. We also show that the sha** time used to calculate energy with a trapezoidal filter can be significantly reduced while maintaining a comparable energy resolution. Under certain circumstances, our denoising method can improve the overall energy resolution. The methods we developed to remove electronic noise are straightforward to extend to other detector technologies. Furthermore, the latent representation from the encoder is also of use in quantifying shape-based characteristics of the signals. Our work has great potential to be used in particle physics experiments and beyond.
△ Less
Submitted 1 December, 2022; v1 submitted 13 April, 2022;
originally announced April 2022.
-
Experimental study of 13C(α,n)16O reactions in the Majorana Demonstrator calibration data
Authors:
MAJORANA Collaboration,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (33 additional authors not shown)
Abstract:
Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied $^{13}$C($α,n)^{16}$O reactions induced by $α$-particles emitted within the calibration sources of the \textsc{Majorana Demonstrator}. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimate…
▽ More
Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied $^{13}$C($α,n)^{16}$O reactions induced by $α$-particles emitted within the calibration sources of the \textsc{Majorana Demonstrator}. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimated by using the 6129-keV $γ$-rays emitted from the excited $^{16}$O states that are populated when the incoming $α$-particles exceed the reaction Q-value. Thanks to the excellent energy performance of the \textsc{Demonstrator}'s germanium detectors, these characteristic photons can be clearly observed in the calibration data. Facilitated by \textsc{Geant4} simulations, a comparison between the observed 6129-keV photon rates and predictions by a TALYS-based software was performed. The measurements and predictions were found to be consistent, albeit with large statistical uncertainties. This agreement provides support for background projections from ($α,n$)-reactions in future double-beta decay search efforts.
△ Less
Submitted 11 July, 2022; v1 submitted 27 March, 2022;
originally announced March 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Measurements of the ionization efficiency of protons in methane
Authors:
NEWS-G Collaboration,
:,
L. Balogh,
C. Beaufort,
A. Brossard,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi-Fard,
Y. Deng,
K. Dering,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly
, et al. (19 additional authors not shown)
Abstract:
The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below…
▽ More
The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below $50~\mathrm{keV}$), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV, with kinetic energies in between $2~\mathrm{keV}$ and $13~\mathrm{keV}$ in $100~\mathrm{mbar}$ of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by $\mathrm{IQF}~(E_K)= E_K^α~/~(β+ E_K^α)$ with $α=0.70\pm0.08$ and $β= 1.32\pm0.17$. In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching $33\%$ at $2~\mathrm{keV}$
△ Less
Submitted 25 June, 2022; v1 submitted 24 January, 2022;
originally announced January 2022.
-
The MAJORANA DEMONSTRATOR Readout Electronics System
Authors:
N. Abgrall,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
K. H. Bhimani,
B. Bos,
A. W. Bradley,
T. H. Burritt,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
R. J. Cooper,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko
, et al. (54 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper prov…
▽ More
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the MAJORANA DEMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.
△ Less
Submitted 23 February, 2022; v1 submitted 17 November, 2021;
originally announced November 2021.
-
Signatures of muonic activation in the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
T. R. Edwards,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (33 additional authors not shown)
Abstract:
Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurities present in construction and detector materials can be suppressed using a number of well-understood techniques. Background from in-situ cosmogenic interactions can be reduced by siting an experiment deep underground.…
▽ More
Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurities present in construction and detector materials can be suppressed using a number of well-understood techniques. Background from in-situ cosmogenic interactions can be reduced by siting an experiment deep underground. However, the next generation of such experiments have unprecedented sensitivity goals of 10$^{28}$ years half-life with background rates of 10$^{-5}$cts/(keV kg yr) in the region of interest. To achieve these goals, the remaining cosmogenic background must be well understood. In the work presented here, Majorana Demonstrator data is used to search for decay signatures of meta-stable germanium isotopes. Contributions to the region of interest in energy and time are estimated using simulations, and compared to Demonstrator data. Correlated time-delayed signals are used to identify decay signatures of isotopes produced in the germanium detectors. A good agreement between expected and measured rate is found and different simulation frameworks are used to estimate the uncertainties of the predictions. The simulation campaign is then extended to characterize the background for the LEGEND experiment, a proposed tonne-scale effort searching for neutrinoless double-beta decay in $^{76}$Ge.
△ Less
Submitted 27 October, 2021;
originally announced October 2021.
-
Neural Upscaling from Residue-level Protein Structure Networks to Atomistic Structure
Authors:
Vy Duong,
Elizabeth Diessner,
Gianmarc Grazioli,
Rachel W. Martin,
Carter T. Butts
Abstract:
Coarse-graining is a powerful tool for extending the reach of dynamic models of proteins and other biological macromolecules. Topological coarse-graining, in which biomolecules or sets thereof are represented via graph structures, is a particularly useful way of obtaining highly compressed representations of molecular structure, and simulations operating via such representations can achieve substa…
▽ More
Coarse-graining is a powerful tool for extending the reach of dynamic models of proteins and other biological macromolecules. Topological coarse-graining, in which biomolecules or sets thereof are represented via graph structures, is a particularly useful way of obtaining highly compressed representations of molecular structure, and simulations operating via such representations can achieve substantial computational savings. A drawback of coarse-graining, however, is the loss of atomistic detail - an effect that is especially acute for topological representations such as protein structure networks (PSNs). Here, we introduce an approach based on a combination of machine learning and physically-guided refinement for inferring atomic coordinates from PSNs. This "neural upscaling" procedure exploits the constraints implied by PSNs on possible configurations, as well as differences in the likelihood of observing different configurations with the same PSN. Using a 1 $μ$s atomistic molecular dynamics trajectory of A$β_{1-40}$, we show that neural upscaling is able to effectively recapitulate detailed structural information for intrinsically disordered proteins, being particularly successful in recovering features such as transient secondary structure. These results suggest that scalable network-based models for protein structure and dynamics may be used in settings where atomistic detail is desired, with upscaling employed to impute atomic coordinates from PSNs.
△ Less
Submitted 25 August, 2021;
originally announced September 2021.
-
Quenching factor measurements of neon nuclei in neon gas
Authors:
L. Balogh,
C. Beaufort,
A. Brossard,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi Fard,
Y. Deng,
K. Dering,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly,
P. Knights,
L. Kwon
, et al. (25 additional authors not shown)
Abstract:
The NEWS-G collaboration uses Spherical Proportional Counters (SPCs) to search for weakly interacting massive particles (WIMPs). In this paper, we report the first measurements of the nuclear quenching factor in neon gas at \SI{2}{bar} using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modelled using a simple power law: $α$E…
▽ More
The NEWS-G collaboration uses Spherical Proportional Counters (SPCs) to search for weakly interacting massive particles (WIMPs). In this paper, we report the first measurements of the nuclear quenching factor in neon gas at \SI{2}{bar} using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modelled using a simple power law: $α$E$_{nr}^β$; we determine its parameters by simultaneously fitting the data collected with the detector over a range of energies. We measured the following parameters in Ne:CH$_{4}$ at \SI{2}{bar}: $α$ = 0.2801 $\pm$ 0.0050 (fit) $\pm$ 0.0045 (sys) and $β$ = 0.0867 $\pm$ 0.020 (fit) $\pm$ 0.006(sys). Our measurements do not agree with expected values from SRIM or Lindhard theory. We demonstrated the feasibility of performing quenching factor measurements at sub-keV energies in gases using SPCs and a neutron beam.
△ Less
Submitted 3 December, 2021; v1 submitted 2 September, 2021;
originally announced September 2021.
-
Bayesian Estimation of the Hydroxyl Radical Diffusion Coefficient at Low Temperature and High Pressure from Atomistic Molecular Dynamics
Authors:
Carter T. Butts,
Rachel W. Martin
Abstract:
The hydroxyl radical is the primary reactive oxygen species produced by the radiolysis of water, and is a significant source of radiation damage to living organisms. Mobility of the hydroxyl radical at low temperatures and/or high pressures is hence a potentially important factor in determining the challenges facing psychrophilic and/or barophilic organisms in high-radiation environments (e.g., ic…
▽ More
The hydroxyl radical is the primary reactive oxygen species produced by the radiolysis of water, and is a significant source of radiation damage to living organisms. Mobility of the hydroxyl radical at low temperatures and/or high pressures is hence a potentially important factor in determining the challenges facing psychrophilic and/or barophilic organisms in high-radiation environments (e.g., ice-interface or undersea environments in which radiative heating is a potential heat and energy source). Here, we estimate the diffusion coefficient for the hydroxyl radical in aqueous solution, using a hierarchical Bayesian model based on atomistic molecular dynamics trajectories in TIP4P/2005 water over a range of temperatures and pressures.
△ Less
Submitted 25 August, 2021;
originally announced August 2021.
-
LEGEND-1000 Preconceptual Design Report
Authors:
LEGEND Collaboration,
N. Abgrall,
I. Abt,
M. Agostini,
A. Alexander,
C. Andreoiu,
G. R. Araujo,
F. T. Avignone III,
W. Bae,
A. Bakalyarov,
M. Balata,
M. Bantel,
I. Barabanov,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
L. Baudis,
C. Bauer,
E. Bernieri,
L. Bezrukov,
K. H. Bhimani,
V. Biancacci,
E. Blalock,
A. Bolozdynya
, et al. (239 additional authors not shown)
Abstract:
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory…
▽ More
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory. By combining the lowest background levels with the best energy resolution in the field, LEGEND-1000 will perform a quasi-background-free search and can make an unambiguous discovery of neutrinoless double-beta decay with just a handful of counts at the decay $Q$ value. The experiment is designed to probe this decay with a 99.7%-CL discovery sensitivity in the $^{76}$Ge half-life of $1.3\times10^{28}$ years, corresponding to an effective Majorana mass upper limit in the range of 9-21 meV, to cover the inverted-ordering neutrino mass scale with 10 yr of live time.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
The Notre-Dame Cube: An active-target time-projection chamber for radioactive beam experiments and detector development
Authors:
T. Ahn,
J. S. Randhawa,
S. Aguilar,
D. Blankstein,
L. Delgado,
N. Dixneuf,
S. L. Henderson,
W. Jackson,
L. Jensen,
S. **,
J. Koci,
J. J. Kolata,
J. Lai,
J. Levano,
X. Li,
A. Mubarak,
P. D. O'Malley,
S. Rameriz Martin,
M. Renaud,
M. Z. Serikow,
A. Tollefson,
J. Wilson,
L. Yan
Abstract:
Active-target detectors have the potential to address the difficulties associated with the low intensities of radioactive beams. We have developed an active-target detector, the Notre Dame Cube (ND-Cube), to perform experiments with radioactive beams produced at $\mathit{TwinSol}$ and to aid in the development of active-target techniques. Various aspects of the ND-Cube and its design were characte…
▽ More
Active-target detectors have the potential to address the difficulties associated with the low intensities of radioactive beams. We have developed an active-target detector, the Notre Dame Cube (ND-Cube), to perform experiments with radioactive beams produced at $\mathit{TwinSol}$ and to aid in the development of active-target techniques. Various aspects of the ND-Cube and its design were characterized. The ND-Cube was commissioned with a $^{7}$Li beam for measuring $^{40}$Ar + $^{7}$Li fusion reaction cross sections and investigating $^{7}$Li($α$,$α$)$^{7}$Li scattering events. The ND-Cube will be used to study a range of reactions using light radioactive ions produced at low energy.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.
-
Optical calibration of the SNO+ detector in the water phase with deployed sources
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
F. Barão,
N. Barros,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
M. Chen,
O. Chkvorets,
B. Cleveland,
D. Cookman,
J. Corning,
M. A. Cox,
C. Deluce,
M. M. Depatie
, et al. (98 additional authors not shown)
Abstract:
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light…
▽ More
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. The calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.
△ Less
Submitted 4 October, 2021; v1 submitted 7 June, 2021;
originally announced June 2021.
-
Optimal Transport for Parameter Identification of Chaotic Dynamics via Invariant Measures
Authors:
Yunan Yang,
Levon Nurbekyan,
Elisa Negrini,
Robert Martin,
Mirjeta Pasha
Abstract:
We study an optimal transportation approach for recovering parameters in dynamical systems with a single smoothly varying attractor. We assume that the data is not sufficient for estimating time derivatives of state variables but enough to approximate the long-time behavior of the system through an approximation of its physical measure. Thus, we fit physical measures by taking the Wasserstein dist…
▽ More
We study an optimal transportation approach for recovering parameters in dynamical systems with a single smoothly varying attractor. We assume that the data is not sufficient for estimating time derivatives of state variables but enough to approximate the long-time behavior of the system through an approximation of its physical measure. Thus, we fit physical measures by taking the Wasserstein distance from optimal transportation as a misfit function between two probability distributions. In particular, we analyze the regularity of the resulting loss function for general transportation costs and derive gradient formulas. Physical measures are approximated as fixed points of suitable PDE-based Perron--Frobenius operators. Test cases discussed in the paper include common low-dimensional dynamical systems.
△ Less
Submitted 11 April, 2022; v1 submitted 30 April, 2021;
originally announced April 2021.
-
The SNO+ Experiment
Authors:
SNO+ Collaboration,
:,
V. Albanese,
R. Alves,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
S. Back,
F. Barão,
Z. Barnard,
A. Barr,
N. Barros,
D. Bartlett,
R. Bayes,
C. Beaudoin,
E. W. Beier,
G. Berardi,
A. Bialek,
S. D. Biller,
E. Blucher
, et al. (229 additional authors not shown)
Abstract:
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of pr…
▽ More
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of process plants, commissioning efforts, electronics upgrades, data acquisition systems, and calibration techniques. The SNO+ collaboration is reusing the acrylic vessel, PMT array, and electronics of the SNO detector, having made a number of experimental upgrades and essential adaptations for use with the liquid scintillator. With low backgrounds and a low energy threshold, the SNO+ collaboration will also pursue a rich physics program beyond the search for $0νββ$ decay, including studies of geo- and reactor antineutrinos, supernova and solar neutrinos, and exotic physics such as the search for invisible nucleon decay. The SNO+ approach to the search for $0νββ$ decay is scalable: a future phase with high $^{130}$Te-loading is envisioned to probe an effective Majorana mass in the inverted mass ordering region.
△ Less
Submitted 25 August, 2021; v1 submitted 23 April, 2021;
originally announced April 2021.
-
Rapid chemically selective 3D imaging in the mid-infrared with a Si-based camera
Authors:
Eric O. Potma,
David Knez,
Yong Chen,
Amanda Durkin,
Alexander Fast,
Mihaela Balu,
Brenna Norton-Baker,
Tommaso Baldacchini,
Rachel Martin,
Dmitry A. Fishman
Abstract:
The emerging technique of mid-infrared optical coherence tomography (MIR-OCT) takes advantage of the reduced scattering of MIR light in various materials and devices, enabling tomographic imaging at deeper penetration depths. Because of challenges in MIR detection technology, the image acquisition time is however significantly longer than for tomographic imaging methods in the visible/near-infrare…
▽ More
The emerging technique of mid-infrared optical coherence tomography (MIR-OCT) takes advantage of the reduced scattering of MIR light in various materials and devices, enabling tomographic imaging at deeper penetration depths. Because of challenges in MIR detection technology, the image acquisition time is however significantly longer than for tomographic imaging methods in the visible/near-infrared. Here we demonstrate an alternative approach to MIR tomography with high-speed imaging capabilities. Through femtosecond non-degenerate two-photon absorption of MIR light in a conventional Si-based CCD camera, we achieve wide-field, high-definition tomographic imaging with chemical selectivity of structured materials and biological samples in mere seconds.
△ Less
Submitted 1 March, 2021;
originally announced March 2021.
-
Development, characterisation, and deployment of the SNO+ liquid scintillator
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
D. Bartlett,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
D. Braid,
E. Caden,
E. J. Callaghan,
J. Caravaca
, et al. (201 additional authors not shown)
Abstract:
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity,…
▽ More
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity, ease of handling, and logistical availability. Its properties have been extensively characterized and are presented here. This liquid scintillator is now used in several neutrino physics experiments in addition to SNO+.
△ Less
Submitted 21 February, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Experimental development and evaluation of a volume coil with slotted end-rings coil for rat MRI at 7 T
Authors:
S. Solis-Najera,
R. Martin,
F. Vazquez,
O. Marrufo,
A. O. Rodriguez
Abstract:
A volume coil with squared slots-end ring was developed to attain improved sensitivity for imaging of rat's brain at 7 T. The principles of the high cavity resonator for the low-pass case and the law of Biot-Savart were used to derive a theoretical expression of the coil sensitivity. The slotted-end ring resonator showed a theoretical 2.22-fold improvement over the standard birdcage coil with simi…
▽ More
A volume coil with squared slots-end ring was developed to attain improved sensitivity for imaging of rat's brain at 7 T. The principles of the high cavity resonator for the low-pass case and the law of Biot-Savart were used to derive a theoretical expression of the coil sensitivity. The slotted-end ring resonator showed a theoretical 2.22-fold improvement over the standard birdcage coil with similar dimensions. Numerical studies were carried out for the electromagnetic fields and specific absorption rates for our coil and a birdcage coil loaded with a saline-filled cylindrical phantom and a digital brain of a rat. An improvement of the signal-to-noise ratio (SNR) can be observed for the slotted volume coil over the birdcage regardless of the load used in the electromagnetic simulations. The specific absorption rate simulations show an important decrement for the digital brain and quite similar values with the saline solution phantom. Phantom and rat's brain images were acquired at 7 T to prove the viability of the coil design. The experimental noise figure of our coil design was four times less than the standard birdcage with similar dimensions, witch showed a 30% increase in experimental SNR. There is remarkable agreement among the theoretical, numerical and experimental sensitivity values, which all demonstrate that the coil performance for MR imaging of small rodents can be improved using slotted end-rings.
△ Less
Submitted 11 August, 2020;
originally announced August 2020.
-
Evaluation of the Visibility and Artifacts of 11 Common Fiducial Markers for Image-Guided Stereotactic Body Radiation Therapy in the Abdomen
Authors:
Jordan M. Slagowski,
Lauren E. Colbert,
Irina M. Cazacu,
Ben S. Singh,
Rachael Martin,
Eugene J. Koay,
Cullen M. Taniguchi,
Albert C. Koong,
Manoop S. Bhutani,
Joseph M. Herman,
Sam Beddar
Abstract:
The purpose of this study was to quantitatively evaluate the visibility and artifacts of commercially available fiducial markers in order to optimize their selection for image-guided stereotactic body radiation therapy (SBRT). From six different vendors, we selected 11 fiducials commonly used in image-guided radiation therapy (IGRT); the fiducials varied in material composition (gold, platinum, ca…
▽ More
The purpose of this study was to quantitatively evaluate the visibility and artifacts of commercially available fiducial markers in order to optimize their selection for image-guided stereotactic body radiation therapy (SBRT). From six different vendors, we selected 11 fiducials commonly used in image-guided radiation therapy (IGRT); the fiducials varied in material composition (gold, platinum, carbon), shape (cylindrical, notched/linear, coiled, ball-like, step), and size measured in terms of diameter (0.28-1.0 mm) and length (3.0-20.0 mm). Each fiducial was centered in 4-mm bolus within a 13-cm-thick water-equivalent phantom. Fiducials were imaged with use of a simulation computed tomography (CT) scanner, a CT-on-rails system, and an onboard cone-beam CT system. Acquisition parameters were set according to clinical protocols. Visibility was assessed in terms of contrast and the Michelson visibility metric. Artifacts were quantified in terms of relative standard deviation and relative streak artifacts level (rSAL). Twelve radiation oncologists ranked each fiducial in terms of clinical usefulness. Contrast and artifacts increased with fiducial size. For CT imaging, maximum contrast (2722 HU) and artifacts (rSAL=2.69) occurred for the largest-diameter (0.75 mm) platinum fiducial. Minimum contrast (551 HU) and reduced artifacts (rSAL=0.65) were observed for the smallest-diameter (0.28 mm) gold fiducial. Carbon produced the least severe artifacts (rSAL = 0.29). The survey indicated that physicians preferred gold fiducials with a 0.35- to 0.43-mm diameter, 5- to 10-mm length, and a coiled or cylindrical shape that balanced contrast and artifacts. We evaluated 11 different fiducials in terms of visibility and artifacts. The results of this study may assist radiation oncologists who seek to maximize contrast, minimize artifacts, and/or balance contrast versus artifacts by fiducial selection.
△ Less
Submitted 10 August, 2020;
originally announced August 2020.
-
Copper electroplating for background suppression in the NEWS-G experiment
Authors:
NEWS-G Collaboration,
:,
L. Balogh,
C. Beaufort,
A. Brossard,
R. Bunker,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi Fard,
Y. Deng,
K. Dering,
D. Durnford,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly
, et al. (26 additional authors not shown)
Abstract:
New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper.…
▽ More
New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper. Such copper is widely used in rare-event searches because it is readily available, there are no long-lived Cu radioisotopes, and levels of non-Cu radiocontaminants are generally low. However, measurements performed with a dedicated 210Po alpha counting method using an XIA detector confirmed a problematic concentration of 210Pb in bulk of the copper. To shield the proportional counter's active volume, a low-background electroforming method was adapted to the hemispherical shape to grow a 500-$μ$m thick layer of ultra-radiopure copper to the detector's inner surface. In this paper the process is described, which was prototyped at Pacific Northwest National Laboratory (PNNL), USA, and then conducted at full scale in the Laboratoire Souterrain de Modane in France. The radiopurity of the electroplated copper was assessed through Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Measurements of samples from the first (second) hemisphere give 68% confidence upper limits of <0.58 $μ$Bq/kg (<0.24 $μ$Bq/kg) and <0.26 $μ$Bq/kg (<0.11 $μ$Bq/kg) on the 232Th and 238U contamination levels, respectively. These results are comparable to previously reported measurements of electroformed copper produced for other rare-event searches, which were also found to have low concentration of 210Pb consistent with the background goals of the NEWS-G experiment.
△ Less
Submitted 13 December, 2020; v1 submitted 7 August, 2020;
originally announced August 2020.
-
FCC-hh Experimental Insertion Region Design
Authors:
Jose L. Abelleira,
Robert B. Appleby,
Sergey Arsenyev,
Javier Barranco,
Michael Benedikt,
Maria Ilaria Besana,
Oscar Blanco Garcia,
Manuela Boscolo,
David Boutin,
Xavier Buffat,
Helmut Burkhardt,
Francesco Cerutti,
Antoine Chance,
Francesco Collamati,
Emilia Cruz-Alaniz,
Barbara Dalena,
Michael Hofer,
Barbara L. Humann,
Angelo Infantino,
Jacqueline Keintzel,
Andy Langner,
Marian Luckhof,
Roman Martin,
Tatiana Pieloni,
Haroon Rafique
, et al. (7 additional authors not shown)
Abstract:
The Future Circular Collider study is exploring possible designs of circular colliders for the post-LHC era, as recommended by the European Strategy Group for High Energy Physics. One such option is FCC-hh, a proton-proton collider with a centre-of-mass energy of 100 TeV. The experimental insertion regions are key areas defining the performance of the collider. This paper presents the first insert…
▽ More
The Future Circular Collider study is exploring possible designs of circular colliders for the post-LHC era, as recommended by the European Strategy Group for High Energy Physics. One such option is FCC-hh, a proton-proton collider with a centre-of-mass energy of 100 TeV. The experimental insertion regions are key areas defining the performance of the collider. This paper presents the first insertion region designs with a complete assessment of the main challenges, as collision debris with two orders of magnitude larger power than current colliders, beam-beam interactions in long insertions, dynamic aperture for optics with peak $β$ functions one order of magnitude above current colliders, photon background from synchrotron radiation and cross talk between the insertion regions. An alternative design avoiding the use of crab cavities with a small impact on performance is also presented.
△ Less
Submitted 23 July, 2020;
originally announced July 2020.
-
$α$-event Characterization and Rejection in Point-Contact HPGe Detectors
Authors:
The MAJORANA Collaboration,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
T. R. Edwards,
D. W. Edwins,
Yu. Efremenko,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (40 additional authors not shown)
Abstract:
P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector's response to $α$ particles incident on the sensitive passivated and p+ surfaces, a previously poorly-understood source of background. The detector studied is identical…
▽ More
P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector's response to $α$ particles incident on the sensitive passivated and p+ surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the MAJORANA DEMONSTRATOR experiment, a search for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. $α$ decays on most of the passivated surface exhibit significant energy loss due to charge trap**, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $α$ identification, reliably identifying $α$ background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $α$ events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $0νββ$ region of interest window by an order of magnitude in the MAJORANA DEMONSTRATOR, and will be used in the upcoming LEGEND-200 experiment.
△ Less
Submitted 14 March, 2022; v1 submitted 23 June, 2020;
originally announced June 2020.
-
Satellite-based estimates of decline and rebound in China's CO$_2$ emissions during COVID-19 pandemic
Authors:
Bo Zheng,
Guannan Geng,
Philippe Ciais,
Steven J. Davis,
Randall V. Martin,
Jun Meng,
Nana Wu,
Frederic Chevallier,
Gregoire Broquet,
Folkert Boersma,
Ronald van der A,
**tai Lin,
Dabo Guan,
Yu Lei,
Kebin He,
Qiang Zhang
Abstract:
Changes in CO$_2$ emissions during the COVID-19 pandemic have been estimated from indicators on activities like transportation and electricity generation. Here, we instead use satellite observations together with bottom-up information to track the daily dynamics of CO$_2$ emissions during the pandemic. Unlike activity data, our observation-based analysis can be independently evaluated and can prov…
▽ More
Changes in CO$_2$ emissions during the COVID-19 pandemic have been estimated from indicators on activities like transportation and electricity generation. Here, we instead use satellite observations together with bottom-up information to track the daily dynamics of CO$_2$ emissions during the pandemic. Unlike activity data, our observation-based analysis can be independently evaluated and can provide more detailed insights into spatially-explicit changes. Specifically, we use TROPOMI observations of NO$_2$ to deduce ten-day moving averages of NO$_x$ and CO$_2$ emissions over China, differentiating emissions by sector and province. Between January and April 2020, China's CO$_2$ emissions fell by 11.5% compared to the same period in 2019, but emissions have since rebounded to pre-pandemic levels owing to the fast economic recovery in provinces where industrial activity is concentrated.
△ Less
Submitted 15 June, 2020;
originally announced June 2020.
-
ADC Nonlinearity Correction for the MAJORANA DEMONSTRATOR
Authors:
N. Abgrall,
J. M. Allmond,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
C. M. Campbell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
H. L. Crawford,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss
, et al. (42 additional authors not shown)
Abstract:
Imperfections in analog-to-digital conversion (ADC) cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the Majorana Demonstrator 76Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC…
▽ More
Imperfections in analog-to-digital conversion (ADC) cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the Majorana Demonstrator 76Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. A simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.
△ Less
Submitted 24 March, 2021; v1 submitted 4 March, 2020;
originally announced March 2020.
-
Measurement of neutron-proton capture in the SNO+ water phase
Authors:
The SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
N. Barros,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
D. Chauhan,
M. Chen,
O. Chkvorets,
B. Cleveland,
M. A. Cox,
M. M. Depatie,
J. Dittmer
, et al. (108 additional authors not shown)
Abstract:
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.…
▽ More
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.2-MeV capture $γ$ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. In addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb.
△ Less
Submitted 13 July, 2020; v1 submitted 24 February, 2020;
originally announced February 2020.
-
A Cryogenic Silicon Interferometer for Gravitational-wave Detection
Authors:
Rana X Adhikari,
Odylio Aguiar,
Koji Arai,
Bryan Barr,
Riccardo Bassiri,
Garilynn Billingsley,
Ross Birney,
David Blair,
Joseph Briggs,
Aidan F Brooks,
Daniel D Brown,
Huy-Tuong Cao,
Marcio Constancio,
Sam Cooper,
Thomas Corbitt,
Dennis Coyne,
Edward Daw,
Johannes Eichholz,
Martin Fejer,
Andreas Freise,
Valery Frolov,
Slawomir Gras,
Anna Green,
Hartmut Grote,
Eric K Gustafson
, et al. (86 additional authors not shown)
Abstract:
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new inst…
▽ More
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor.
△ Less
Submitted 9 June, 2020; v1 submitted 29 January, 2020;
originally announced January 2020.
-
Data-driven simulation of pedestrian collision avoidance with a nonparametric neural network
Authors:
Rafael F. Martin,
Daniel R. Parisi
Abstract:
Data-driven simulation of pedestrian dynamics is an incipient and promising approach for building reliable microscopic pedestrian models. We propose a methodology based on generalized regression neural networks, which does not have to deal with a huge number of free parameters as in the case of multilayer neural networks. Although the method is general, we focus on the one pedestrian-one obstacle…
▽ More
Data-driven simulation of pedestrian dynamics is an incipient and promising approach for building reliable microscopic pedestrian models. We propose a methodology based on generalized regression neural networks, which does not have to deal with a huge number of free parameters as in the case of multilayer neural networks. Although the method is general, we focus on the one pedestrian-one obstacle problem. Experimental data were collected in a motion capture laboratory providing high-precision trajectories. The proposed model allows us to simulate the trajectory of a pedestrian avoiding an obstacle from any direction.
△ Less
Submitted 17 July, 2019;
originally announced July 2019.
-
On a stochastic version of Lanchester's model of combat
Authors:
Michael J. Kearney,
Richard J. Martin
Abstract:
Lanchester's model of combat has certain deficiencies in its standard form arising from the neglect of the influence of random fluctuations. Several approaches to rectify this have been proposed and various results are scattered throughout the literature. Here, a discrete-time stochastic version, which is amenable to exact solution, is revisited with the aim of deriving key results within one sett…
▽ More
Lanchester's model of combat has certain deficiencies in its standard form arising from the neglect of the influence of random fluctuations. Several approaches to rectify this have been proposed and various results are scattered throughout the literature. Here, a discrete-time stochastic version, which is amenable to exact solution, is revisited with the aim of deriving key results within one setting. The exposition simplifies and provides refinements to earlier derivations and analysis.
△ Less
Submitted 8 May, 2019;
originally announced May 2019.
-
Beyond Correlation: A Path-Invariant Measure for Seismogram Similarity
Authors:
Joshua Dickey,
Brett Borghetti,
William Junek,
Richard Martin
Abstract:
Similarity search is a popular technique for seismic signal processing, with template matching, matched filters and subspace detectors being utilized for a wide variety of tasks, including both signal detection and source discrimination. Traditionally, these techniques rely on the cross-correlation function as the basis for measuring similarity. Unfortunately, seismogram correlation is dominated b…
▽ More
Similarity search is a popular technique for seismic signal processing, with template matching, matched filters and subspace detectors being utilized for a wide variety of tasks, including both signal detection and source discrimination. Traditionally, these techniques rely on the cross-correlation function as the basis for measuring similarity. Unfortunately, seismogram correlation is dominated by path effects, essentially requiring a distinct waveform template along each path of interest. To address this limitation, we propose a novel measure of seismogram similarity that is explicitly invariant to path. Using Earthscope's USArray experiment, a path-rich dataset of 207,291 regional seismograms across 8,452 unique events is constructed, and then employed via the batch-hard triplet loss function, to train a deep convolutional neural network which maps raw seismograms to a low dimensional embedding space, where nearness on the space corresponds to nearness of source function, regardless of path or recording instrumentation. This path-agnostic embedding space forms a new representation for seismograms, characterized by robust, source-specific features, which we show to be useful for performing both pairwise event association as well as template-based source discrimination with a single template.
△ Less
Submitted 8 October, 2019; v1 submitted 16 April, 2019;
originally announced April 2019.
-
Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment
Authors:
NEWS-G Collaboration,
:,
Q. Arnaud,
J. -P. Bard,
A. Brossard,
M. Chapellier,
M. Clark,
S. Crawford,
E. C. Corcoran,
A. Dastgheibi-Fard,
K. Dering,
P. Di Stefano,
D. Durnford,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
A. Kamaha,
I. Katsioulas,
D. G. Kelly,
P. Knights
, et al. (15 additional authors not shown)
Abstract:
Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and ana…
▽ More
Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and analysis methodology are presented along with various direct applications for the upcoming next phase of the experiment at SNOLAB. These include the continuous monitoring of the detector response and electron drift properties during dark matter search runs, as well as the experimental measurement of the trigger threshold efficiency. We measure a mean ionization energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$ for 2.8 keV X-rays, and demonstrate the feasibility of performing similar precision measurements at sub-keV energies for future gas mixtures to be used for dark matter searches at SNOLAB.
△ Less
Submitted 24 February, 2019;
originally announced February 2019.
-
Radiative electron capture as a tunable source of highly linearly polarized x-rays
Authors:
M. Vockert,
G. Weber,
H. Bräuning,
A. Surzhykov,
C. Brandau,
S. Fritzsche,
S. Geyer,
S. Hagmann,
S. Hess,
C. Kozhuharov,
R. Märtin,
N. Petridis,
R. Hess,
S. Trotsenko,
Yu. A. Litvinov,
J. Glorius,
A. Gumberidze,
M. Steck,
S. Litvinov,
T. Gaßner,
P. -M. Hillenbrand,
M. Lestinsky,
F. Nolden,
M. S. Sanjari,
U. Popp
, et al. (5 additional authors not shown)
Abstract:
The radiative electron capture (REC) into the K shell of bare Xe ions colliding with a hydrogen gas target has been investigated. In this study, the degree of linear polarization of the K-REC radiation was measured and compared with rigorous relativistic calculations as well as with the previous results recorded for U$^{92+}$. Owing to the improved detector technology a significant gain in precisi…
▽ More
The radiative electron capture (REC) into the K shell of bare Xe ions colliding with a hydrogen gas target has been investigated. In this study, the degree of linear polarization of the K-REC radiation was measured and compared with rigorous relativistic calculations as well as with the previous results recorded for U$^{92+}$. Owing to the improved detector technology a significant gain in precision of the present polarization measurement is achieved compared to the previously published results. The obtained data confirms that for medium-Z ions such as Xe the REC process is a source of highly polarized x-rays which can easily be tuned with respect to the degree of linear polarization and the photon energy. We argue, in particular, that for relatively low energies the photons emitted under large angles are almost fully linear polarized.
△ Less
Submitted 9 May, 2019; v1 submitted 22 February, 2019;
originally announced February 2019.
-
Multi-site event discrimination for the MAJORANA DEMONSTRATOR
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe,
R. J. Hegedus,
L. Hehn
, et al. (38 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay in 76Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the neutrinoless double-beta decay region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysi…
▽ More
The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay in 76Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the neutrinoless double-beta decay region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysis cut applied to achieve this result, named AvsE, is described in this paper. This cut is developed to remove events whose waveforms are typical of multi-site energy deposits while retaining (90 +/- 3.5)% of single-site events. This pulse shape discrimination is based on the relationship between the maximum current and energy, and tuned using 228Th calibration source data. The efficiency uncertainty accounts for variation across detectors, energy, and time, as well as for the position distribution difference between calibration and $0νββ$ events, established using simulations.
△ Less
Submitted 16 January, 2019;
originally announced January 2019.
-
Recent results from the MAJORANA DEMONSTRATOR
Authors:
J. Myslik,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
B. Bos,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decay in $^{76}$Ge and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modules of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, operating at the 4850' level of the Sanford Underground Research Facility in Lead, S…
▽ More
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decay in $^{76}$Ge and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modules of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, operating at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Commissioning of the experiment began in June 2015, followed by data production with the full detector array in August 2016. The ultra-low background and record energy resolution achieved by the MAJORANA DEMONSTRATOR enable a sensitive neutrinoless double-beta decay search, as well as additional searches for physics beyond the Standard Model. I will discuss the design elements that enable these searches, along with the latest results, focusing on the neutrinoless double-beta decay search. I will also discuss the current status and the future plans of the MAJORANA DEMONSTRATOR, as well as the plans for a future tonne-scale $^{76}$Ge experiment.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.