-
XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
D. Antón Martin,
F. Arneodo,
L. Baudis,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
K. Boese,
A. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
A. P. Cimental Chávez,
A. P. Colijn,
J. Conrad,
J. J. Cuenca-García,
V. D'Andrea
, et al. (139 additional authors not shown)
Abstract:
The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 t…
▽ More
The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 tonne-years yielded no signal excess over background expectations, from which competitive exclusion limits were derived on WIMP-nucleon elastic scatter cross sections, for WIMP masses ranging from 6 GeV/$c^2$ up to the TeV/$c^2$ scale. This work details the modeling and statistical methods employed in this search. By means of calibration data, we model the detector response, which is then used to derive background and signal models. The construction and validation of these models is discussed, alongside additional purely data-driven backgrounds. We also describe the statistical inference framework, including the definition of the likelihood function and the construction of confidence intervals.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Heavy-element damage seeding in proteins under X-ray free electron laser illumination conditions
Authors:
Spencer K. Passmore,
Alaric L. Sanders,
Andrew V. Martin,
Harry M. Quiney
Abstract:
The emerging technique of serial femtosecond X-ray crystallography (SFX) can be used to study the structure and dynamics of biological macromolecules to high spatial and temporal resolutions. An ongoing challenge for SFX is the damage caused by the ultrabright X-ray free electron laser pulse. Though it is often assumed that sufficiently femtosecond pulses `outrun' radiation damage, in reality elec…
▽ More
The emerging technique of serial femtosecond X-ray crystallography (SFX) can be used to study the structure and dynamics of biological macromolecules to high spatial and temporal resolutions. An ongoing challenge for SFX is the damage caused by the ultrabright X-ray free electron laser pulse. Though it is often assumed that sufficiently femtosecond pulses `outrun' radiation damage, in reality electronic damage processes commence during exposure. We model the electronic damage to protein nanocrystals using a plasma model that tracks the continuous changes to the energy distribution of the unbound electrons. Tracking the continuous energy distribution is of particular importance for distinguishing the influence of differing elements on secondary damage processes. Heavy atoms have a ubiquitous but small presence in protein targets - typically as integral components of the macromolecule and as salts in the solvent. We find that these atoms considerably influence the simulated ionization and scattering behavior of realistic targets due to their rapid seeding of secondary ionization processes. In lysozyme, even the presence of native sulfur atoms significantly contributes to theoretical measures of damage-induced noise for >= 6 keV, 15 fs pulses. Contributing to the effect is that heavy atoms seed `intermediate' energy electron cascades that are particularly effective at ionizing the target on the femtosecond timescale. In addition, the disproportionate effect of heavy atoms means the damage to a protein crystal can be sensitive to their presence in the solvent. Outside of reducing the concentration of heavy atoms in the target, these results suggest the dose limits of SFX targets will be higher where the ionization of deep >~ 6 keV absorption edges is minimized, or, to a lesser extent, when such edges are only ionized with X-rays >> 2 keV above their binding energy.
△ Less
Submitted 27 May, 2024; v1 submitted 16 May, 2024;
originally announced May 2024.
-
Offline tagging of radon-induced backgrounds in XENON1T and applicability to other liquid xenon detectors
Authors:
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
G. Bruno,
R. Budnik,
T. K. Bui,
J. M. R. Cardoso,
A. P. Cimental Chavez,
A. P. Colijn,
J. Conrad
, et al. (142 additional authors not shown)
Abstract:
This paper details the first application of a software tagging algorithm to reduce radon-induced backgrounds in liquid noble element time projection chambers, such as XENON1T and XENONnT. The convection velocity field in XENON1T was mapped out using $^{222}\text{Rn}$ and $^{218}\text{Po}$ events, and the root-mean-square convection speed was measured to be $0.30 \pm 0.01$ cm/s. Given this velocity…
▽ More
This paper details the first application of a software tagging algorithm to reduce radon-induced backgrounds in liquid noble element time projection chambers, such as XENON1T and XENONnT. The convection velocity field in XENON1T was mapped out using $^{222}\text{Rn}$ and $^{218}\text{Po}$ events, and the root-mean-square convection speed was measured to be $0.30 \pm 0.01$ cm/s. Given this velocity field, $^{214}\text{Pb}$ background events can be tagged when they are followed by $^{214}\text{Bi}$ and $^{214}\text{Po}$ decays, or preceded by $^{218}\text{Po}$ decays. This was achieved by evolving a point cloud in the direction of a measured convection velocity field, and searching for $^{214}\text{Bi}$ and $^{214}\text{Po}$ decays or $^{218}\text{Po}$ decays within a volume defined by the point cloud. In XENON1T, this tagging system achieved a $^{214}\text{Pb}$ background reduction of $6.2^{+0.4}_{-0.9}\%$ with an exposure loss of $1.8\pm 0.2 \%$, despite the timescales of convection being smaller than the relevant decay times. We show that the performance can be improved in XENONnT, and that the performance of such a software-tagging approach can be expected to be further improved in a diffusion-limited scenario. Finally, a similar method might be useful to tag the cosmogenic $^{137}\text{Xe}$ background, which is relevant to the search for neutrinoless double-beta decay.
△ Less
Submitted 19 June, 2024; v1 submitted 21 March, 2024;
originally announced March 2024.
-
The XENONnT Dark Matter Experiment
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
M. Balata,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui
, et al. (170 additional authors not shown)
Abstract:
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in…
▽ More
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
Tunable circular dichroism through absorption in coupled optical modes of twisted triskelia nanostructures
Authors:
Javier Rodriguez Alvarez,
Antonio Garcia Martin,
Arantxa Fraile Rodriguez,
Xavier Batlle,
Amilcar Labarta
Abstract:
We present a system consisting of two stacked chiral plasmonic nanoelements, so-called triskelia, that exhibits a high degree of circular dichroism. The optical modes arising from the interactions between the two elements are the main responsible for the dichroic signal. Their excitation in the absorption cross section is favored when the circular polarization of the light is opposite to the helic…
▽ More
We present a system consisting of two stacked chiral plasmonic nanoelements, so-called triskelia, that exhibits a high degree of circular dichroism. The optical modes arising from the interactions between the two elements are the main responsible for the dichroic signal. Their excitation in the absorption cross section is favored when the circular polarization of the light is opposite to the helicity of the system, so that an intense near-field distribution with 3D character is excited between the two triskelia, which in turn causes the dichroic response. Therefore, the stacking, in itself, provides a simple way to tune both the value of the circular dichroism, up to 60%, and its spectral distribution in the visible and near infrared range. We show how these interaction-driven modes can be controlled by finely tuning the distance and the relative twist angle between the triskelia, yielding maximum values of the dichroism at 20° and 100° for left- and right-handed circularly polarized light, respectively. Despite the three-fold symmetry of the elements, these two situations are not completely equivalent since the interplay between the handedness of the stack and the chirality of each single element breaks the symmetry between clockwise and anticlockwise rotation angles around 0°. This reveals the occurrence of clear helicity-dependent resonances. The proposed structure can be thus finely tuned to tailor the dichroic signal for applications at will, such as highly efficient helicity-sensitive surface spectroscopies or single-photon polarization detectors, among others.
△ Less
Submitted 24 January, 2024;
originally announced January 2024.
-
Wavelength dependence of nitrogen-vacancy center charge cycling
Authors:
A. A. Wood,
A. Lozovoi,
R. M. Goldblatt,
C. A. Meriles,
A. M. Martin
Abstract:
Optically-active spin qubits in wide-bandgap semiconductors exist in several charge states, though typically only specific charge states exhibit desirable spin or photonic properties. An understanding of how interconversion between different charge states occurs is important for most applications seeking to employ such defects in quantum sensing and information processing, and additionally serves…
▽ More
Optically-active spin qubits in wide-bandgap semiconductors exist in several charge states, though typically only specific charge states exhibit desirable spin or photonic properties. An understanding of how interconversion between different charge states occurs is important for most applications seeking to employ such defects in quantum sensing and information processing, and additionally serves as a means of testing and verifying models of the defect electronic structure. Here, we use charge-sensitive confocal imaging to study the wavelength dependence of optical carrier generation in diamonds hosting nitrogen-vacancy (NV) centers, silicon vacancy (SiV) centers and substitutional nitrogen (N). We study the generation of distinctive charge-capture patterns formed when photogenerated charge carriers are captured by photoluminescent defects, using light spanning 405-633\,nm (1.96-3.06\,eV). We observe distinct regimes where one- or two-photon ionization or recombination processes dominate, and a third regime where anti-Stokes mediated recombination drives weak NV charge cycling with red light. We then compare red-induced charge cycling to fast charge carrier transport between isolated single NV centers driven with green and blue light. This work reports new optically-mediated charge cycling processes of the NV centers, and has consequences for schemes using charge transfer to identify non-luminescent defects and photoelectric detection, where ambiguity exists as to the source of photocurrent.
△ Less
Submitted 23 January, 2024;
originally announced January 2024.
-
Multipartite Entanglement in Bright Frequency Combs from Microresonators
Authors:
Adrien Bensemhoun,
C Gonzalez-Arciniegas,
Olivier Pfister,
Laurent Labont,
Jean Etesse,
Anthony Martin,
Sbastien Tanzilli,
Giuseppe Patera,
Virginia d'Auria
Abstract:
We present a theoretical model of multimode quantum correlations in bright frequency combs generated in continuous-wave regime by microresonators above threshold. Our analysis shows how these correlations emerge from cascading four-wave mixing processes fed by the input pump as well as the generated bright beams. Logarithmic negativity criterion is employed to quantify entanglement between partiti…
▽ More
We present a theoretical model of multimode quantum correlations in bright frequency combs generated in continuous-wave regime by microresonators above threshold. Our analysis shows how these correlations emerge from cascading four-wave mixing processes fed by the input pump as well as the generated bright beams. Logarithmic negativity criterion is employed to quantify entanglement between partitions of modes, demonstrating the transition from a bipartite regime just above the oscillation threshold to the multipartite one at higher input pump powers. Due to its generality, our model can be safely used to describe other kinds of non-linear $χ$ (3) cavities.
△ Less
Submitted 3 October, 2023;
originally announced October 2023.
-
Characterization of LAPPD timing at CERN PS testbeam
Authors:
Deb Sankar Bhattacharya,
Andrea Bressan,
Chandradoy Chatterjee,
Silvia Dalla Torre,
Mauro Gregori,
Alexander Kiselev,
Stefano Levorato,
Anna Martin,
Saverio Minutoli,
Mikhail Osipenko,
Richa Rai,
Marco Ripani,
Fulvio Tessarotto,
Triloki Triloki
Abstract:
Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm$^2$ sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns risetime followed by a slightly longer falltime and their amplitude reaches a few dozen…
▽ More
Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm$^2$ sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns risetime followed by a slightly longer falltime and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. The measured time resolution for single photoelectrons is about 80 ps r.m.s.
△ Less
Submitted 26 September, 2023;
originally announced September 2023.
-
Design and performance of the field cage for the XENONnT experiment
Authors:
E. Aprile,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso,
D. Cichon
, et al. (139 additional authors not shown)
Abstract:
The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field sha** rings connected by an easily accessible resistor chain. Rather than being connected to t…
▽ More
The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field sha** rings connected by an easily accessible resistor chain. Rather than being connected to the gate electrode, the topmost field sha** ring is independently biased, adding a degree of freedom to tune the electric field during operation. Two-dimensional finite element simulations were used to optimize the field cage, as well as its operation. Simulation results were compared to ${}^{83m}\mathrm{Kr}$ calibration data. This comparison indicates an accumulation of charge on the panels of the TPC which is constant over time, as no evolution of the reconstructed position distribution of events is observed. The simulated electric field was then used to correct the charge signal for the field dependence of the charge yield. This correction resolves the inconsistent measurement of the drift electron lifetime when using different calibrations sources and different field cage tuning voltages.
△ Less
Submitted 21 September, 2023;
originally announced September 2023.
-
The pypadf package: computing the pair-angle distribution function from fluctuation scattering data
Authors:
Andrew V. Martin,
Patrick Adams,
Jack Binns
Abstract:
The pair-angle distribution function (PADF) is a three- and four-atom correlation function that can characterise the local angular structure of disordered materials, particles or nanocrystalline materials. The PADF can be measured by x-ray or electron fluctuation diffraction experiments, which can be collected by scanning a small beam across a structurally disordered sample or flowing a sample acr…
▽ More
The pair-angle distribution function (PADF) is a three- and four-atom correlation function that can characterise the local angular structure of disordered materials, particles or nanocrystalline materials. The PADF can be measured by x-ray or electron fluctuation diffraction experiments, which can be collected by scanning a small beam across a structurally disordered sample or flowing a sample across the beam path. It is a natural generalisation of the established pair-distribution methods, which do not provide angular information. This software package provides tools to calculate the PADF from from fluctuation diffraction data. The package includes tools for calculating the intensity correlation function, which is a necessary step in the PADF calculation and also the basis for other fluctuation scattering techniques.
△ Less
Submitted 22 August, 2023;
originally announced September 2023.
-
Long term experience with perfluorobutane in COMPASS RICH
Authors:
F. Bradamante,
A. Bressan,
A. Cicuttin,
M. L. Crespo,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
W. Florian,
L. Garcia Ordonez,
M. Gregori,
A. Kerbizi,
S. Levorato,
A. Martin,
G. Menon,
R. S. Molina,
A. Moretti,
F. Tessarotto,
Triloki,
B. Valinoti
Abstract:
COMPASS RICH-1 has used high-purity perfluorobutane as radiator gas since 2001. The operation and control of the radiator gas has evolved over years with continuous improvements. We report on the experience gained in the 20 year-long operation of perfluorobutane as COMPASS RICH radiator. Very accurate values for the radiator gas refractive index are needed for high-performance particle identificat…
▽ More
COMPASS RICH-1 has used high-purity perfluorobutane as radiator gas since 2001. The operation and control of the radiator gas has evolved over years with continuous improvements. We report on the experience gained in the 20 year-long operation of perfluorobutane as COMPASS RICH radiator. Very accurate values for the radiator gas refractive index are needed for high-performance particle identification. The procedure has evolved over years and the one presently in use, which provides refractive index estimate at the 1 ppm level, is discussed. Perfluorobutane procurement is becoming challenging, and the minimization of material waste is now a priority for the protection of the environment. Commercially available perfluorobutane needs dedicated filtering before usage and typical material losses in the filtering procedure were around 30%. Recent efforts allowed us to reduce them to about 5%. A potential alternative to fluorocarbon radiators in gaseous RICHes is also presented.
△ Less
Submitted 3 August, 2023;
originally announced August 2023.
-
Search for events in XENON1T associated with Gravitational Waves
Authors:
XENON Collaboration,
E. Aprile,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antoń Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso
, et al. (138 additional authors not shown)
Abstract:
We perform a blind search for particle signals in the XENON1T dark matter detector that occur close in time to gravitational wave signals in the LIGO and Virgo observatories. No particle signal is observed in the nuclear recoil, electronic recoil, CE$ν$NS, and S2-only channels within $\pm$ 500 seconds of observations of the gravitational wave signals GW170104, GW170729, GW170817, GW170818, and GW1…
▽ More
We perform a blind search for particle signals in the XENON1T dark matter detector that occur close in time to gravitational wave signals in the LIGO and Virgo observatories. No particle signal is observed in the nuclear recoil, electronic recoil, CE$ν$NS, and S2-only channels within $\pm$ 500 seconds of observations of the gravitational wave signals GW170104, GW170729, GW170817, GW170818, and GW170823. We use this null result to constrain mono-energetic neutrinos and Beyond Standard Model particles emitted in the closest coalescence GW170817, a binary neutron star merger. We set new upper limits on the fluence (time-integrated flux) of coincident neutrinos down to 17 keV at 90% confidence level. Furthermore, we constrain the product of coincident fluence and cross section of Beyond Standard Model particles to be less than $10^{-29}$ cm$^2$/cm$^2$ in the [5.5-210] keV energy range at 90% confidence level.
△ Less
Submitted 27 October, 2023; v1 submitted 20 June, 2023;
originally announced June 2023.
-
Searching for Heavy Dark Matter near the Planck Mass with XENON1T
Authors:
E. Aprile,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso,
D. Cichon
, et al. (142 additional authors not shown)
Abstract:
Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from Multiply-Interacting Massive Particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.…
▽ More
Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from Multiply-Interacting Massive Particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.05 expected background events from muons. Following unblinding, we observe no signal candidate events. This work places strong constraints on spin-independent interactions of dark matter particles with a mass between 1$\times$10$^{12}\,$GeV/c$^2$ and 2$\times$10$^{17}\,$GeV/c$^2$. In addition, we present the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross-sections for dark matter particles with masses close to the Planck scale.
△ Less
Submitted 21 April, 2023;
originally announced April 2023.
-
First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment
Authors:
XENON Collaboration,
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai
, et al. (141 additional authors not shown)
Abstract:
We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid targe…
▽ More
We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid target were reduced to unprecedentedly low levels, giving an electronic recoil background rate of $(15.8\pm1.3)~\mathrm{events}/(\mathrm{t\cdot y \cdot keV})$ in the region of interest. A blind analysis of nuclear recoil events with energies between $3.3$ keV and $60.5$ keV finds no significant excess. This leads to a minimum upper limit on the spin-independent WIMP-nucleon cross section of $2.58\times 10^{-47}~\mathrm{cm}^2$ for a WIMP mass of $28~\mathrm{GeV}/c^2$ at $90\%$ confidence level. Limits for spin-dependent interactions are also provided. Both the limit and the sensitivity for the full range of WIMP masses analyzed here improve on previous results obtained with the XENON1T experiment for the same exposure.
△ Less
Submitted 5 August, 2023; v1 submitted 26 March, 2023;
originally announced March 2023.
-
Mode selection in concentric jets. The steady-steady 1:2 resonant mode interaction with O(2) symmetry
Authors:
Adrián Corrochano,
Javier Sierra-Ausín,
Juan Ángel Martin,
David Fabre,
Soledad Le Clainche
Abstract:
In this article, a thorough characterization of the configuration composed by two concentric jets at a low Reynolds number is presented. The analysis comprises a layout with a wide range for the velocity ratio between the inner and outer jets, defined within the interval [0, 2], and also details the influence of the distance between jets, where the wall thicknesses separating the two jets is [0.5,…
▽ More
In this article, a thorough characterization of the configuration composed by two concentric jets at a low Reynolds number is presented. The analysis comprises a layout with a wide range for the velocity ratio between the inner and outer jets, defined within the interval [0, 2], and also details the influence of the distance between jets, where the wall thicknesses separating the two jets is [0.5, 4]. Global linear stability analysis identifies the most significant modes driving the changes in the flow dynamics. The neutral lines revealing the critical Reynolds number connected to the presence of the main (steady and unsteady) flow bifurcations, which are presented by global azimuthal modes, show the high complexity of the problem under study, where hysteresis and other types of complex cycles are pointed out. Finally, the mode interaction is analysed, highlighting the presence of travelling waves emerging from the interaction of steady states, and the existence of robust heteroclinic cycles that are asymptotically stable. The high level of detail in the results presented, makes this work as a reference for future research development in the field of concentric jets.
△ Less
Submitted 11 January, 2023;
originally announced January 2023.
-
The Triggerless Data Acquisition System of the XENONnT Experiment
Authors:
E. Aprile,
J. Aalbers,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso
, et al. (140 additional authors not shown)
Abstract:
The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commerc…
▽ More
The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commercially available hardware accompanied by open-source and custom-developed software. The three constituent subsystems of the XENONnT detector, the TPC (main detector), muon veto, and the newly introduced neutron veto, are integrated into a single DAQ, and can be operated both independently and as a unified system. In total, the DAQ digitizes the signals of 698 photomultiplier tubes (PMTs), of which 253 from the top PMT array of the TPC are digitized twice, at $\times10$ and $\times0.5$ gain. The DAQ for the most part is a triggerless system, reading out and storing every signal that exceeds the digitization thresholds. Custom-developed software is used to process the acquired data, making it available within $\mathcal{O}\left(10\text{ s}\right)$ for live data quality monitoring and online analyses. The entire system with all the three subsystems was successfully commissioned and has been operating continuously, comfortably withstanding readout rates that exceed $\sim500$ MB/s during calibration. Livetime during normal operation exceeds $99\%$ and is $\sim90\%$ during most high-rate calibrations. The combined DAQ system has collected more than 2 PB of both calibration and science data during the commissioning of XENONnT and the first science run.
△ Less
Submitted 21 December, 2022;
originally announced December 2022.
-
Low-energy Calibration of XENON1T with an Internal $^{37}$Ar Source
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
C. Capelli,
J. M. R. Cardoso
, et al. (139 additional authors not shown)
Abstract:
A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3$\pm$0.3) photons/keV and (40.6$\pm$0.5) electrons/keV, respecti…
▽ More
A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3$\pm$0.3) photons/keV and (40.6$\pm$0.5) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is (68.0$^{+6.3}_{-3.7}$) electrons/keV. The $^{37}$Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at (2.83$\pm$0.02) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that $^{37}$Ar can be considered as a regular calibration source for multi-tonne xenon detectors.
△ Less
Submitted 21 March, 2023; v1 submitted 25 November, 2022;
originally announced November 2022.
-
Coherent dynamics in a five-level atomic system
Authors:
Jan Schütz,
Alexander Martin,
Sanah Laschinger,
Gerhard Birkl
Abstract:
The coherent control of multi-partite quantum systems presents one of the central prerequisites in state-of-the-art quantum information processing. With the added benefit of inherent high-fidelity detection capability, atomic quantum systems in high-energy internal states, such as metastable noble gas atoms, promote themselves as ideal candidates for advancing quantum science in fundamental aspect…
▽ More
The coherent control of multi-partite quantum systems presents one of the central prerequisites in state-of-the-art quantum information processing. With the added benefit of inherent high-fidelity detection capability, atomic quantum systems in high-energy internal states, such as metastable noble gas atoms, promote themselves as ideal candidates for advancing quantum science in fundamental aspects and technological applications. Using laser-cooled neon atoms in the metastable $^3$P$_2$ state of state $1s^2 2s^2 2p^5 3s$ (LS-coupling notation) (Racah notation: $^2P_{3/2}\,3s[3/2]_2$) with five $m_F$-sublevels, experimental methods for the preparation of all Zeeman sublevels |m_J> = |+2>, |+1>, |0>, |-1>, |-2> as well as the coherent control of superposition states in the five-level system |+2> ... |-2>, in the three-level system |+2>, |+1>, |0>, and in the two-level system |+2>, |+1> are presented. The methods are based on optimized radio frequency and laser pulse sequences. The state evolution is described with a simple, semiclassical model. The coherence properties of the prepared states are studied using Ramsey and spin echo measurements.
△ Less
Submitted 21 October, 2022;
originally announced October 2022.
-
Dynamics, scaling behavior, and control of nuclear wrinkling
Authors:
Jonathan A. Jackson,
Nicolas Romeo,
Alexander Mietke,
Keaton J. Burns,
Jan F. Totz,
Adam C. Martin,
Jörn Dunkel,
Jasmin Imran Alsous
Abstract:
The cell nucleus is enveloped by a complex membrane, whose wrinkling has been implicated in disease and cellular aging. The biophysical dynamics and spectral evolution of nuclear wrinkling during multicellular development remain poorly understood due to a lack of direct quantitative measurements. Here, we combine live-imaging experiments, theory, and simulations to characterize the onset and dynam…
▽ More
The cell nucleus is enveloped by a complex membrane, whose wrinkling has been implicated in disease and cellular aging. The biophysical dynamics and spectral evolution of nuclear wrinkling during multicellular development remain poorly understood due to a lack of direct quantitative measurements. Here, we combine live-imaging experiments, theory, and simulations to characterize the onset and dynamics of nuclear wrinkling during egg development in the fruit fly, Drosophila melanogaster, when nurse cell nuclei increase in size and display stereotypical wrinkling behavior. A spectral analysis of three-dimensional high-resolution data from several hundred nuclei reveals a robust asymptotic power-law scaling of angular fluctuations consistent with renormalization and scaling predictions from a nonlinear elastic shell model. We further demonstrate that nuclear wrinkling can be reversed through osmotic shock and suppressed by microtubule disruption, providing tunable physical and biological control parameters for probing mechanical properties of the nuclear envelope. Our findings advance the biophysical understanding of nuclear membrane fluctuations during early multicellular development.
△ Less
Submitted 25 June, 2023; v1 submitted 20 October, 2022;
originally announced October 2022.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
An approximate likelihood for nuclear recoil searches with XENON1T data
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (129 additional authors not shown)
Abstract:
The XENON collaboration has published stringent limits on specific dark matter -nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 tonne-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method…
▽ More
The XENON collaboration has published stringent limits on specific dark matter -nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 tonne-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method we present. The approximate likelihood is constructed in bins of reconstructed energy, profiled along the signal expectation in each bin. This approach can be used to compute an approximate likelihood and therefore most statistical results for any nuclear recoil spectrum. Computing approximate results with this method is approximately three orders of magnitude faster than the likelihood used in the original publications of XENON1T, where limits were set for specific families of recoil spectra. Using this same method, we include toy Monte Carlo simulation-derived binwise likelihoods for the upcoming XENONnT experiment that can similarly be used to assess the sensitivity to arbitrary nuclear recoil signatures in its eventual 20 tonne-year exposure.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Canonical Four-Wave-Mixing in Photonic Crystal Resonators: tuning, tolerances and scaling
Authors:
Alexandre Chopin,
Gabriel Marty,
Inès Ghorbel,
Gréegory Moille,
Aude Martin,
Sylvain Combrié,
Fabrice Raineri,
Alfredo De Rossi
Abstract:
Canonical Four-Wave-Mixing occurs in a resonator with only the required number of modes, thereby inhibiting competing parametric processes. The properties of the recently introduced photonic crystal parametric oscillator, Marty et al. Nat. Photonics, 15, 53 (2021), are discussed extensively. We compare the bichromatic design with other geometries of photonic crystal resonators. Based on a statisti…
▽ More
Canonical Four-Wave-Mixing occurs in a resonator with only the required number of modes, thereby inhibiting competing parametric processes. The properties of the recently introduced photonic crystal parametric oscillator, Marty et al. Nat. Photonics, 15, 53 (2021), are discussed extensively. We compare the bichromatic design with other geometries of photonic crystal resonators. Based on a statistical study over more than 100 resonators and 10 parametric oscillators, robustness against fabrication tolerances is assessed, performances are evaluated in terms of average values and their dispersion, and the dependence on the main parameters is shown to follow the theoretical scaling. The lowest pump power at threshold is $\approx$ 40 $μ$W and we show the existence of a minimum value of the cavity photon lifetime as a condition for parametric oscillation, which is related to three photon absorption.
△ Less
Submitted 10 October, 2022;
originally announced October 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Performance and limitations of dual-comb based ranging systems
Authors:
Bruno Martin,
Patrick Feneyrou,
Daniel Dolfi,
Aude Martin
Abstract:
Dual-comb LiDARs have the potential to perform high-resolution ranging at high speed. Here, through an implementation involving electro-optic modulators and heterodyne detection, we quantify the ranging systems trade-off between precision and non-ambiguity range (NAR) using a unique performance factor. We highlight the influence of the comb amplitude envelope on the precision with a distance measu…
▽ More
Dual-comb LiDARs have the potential to perform high-resolution ranging at high speed. Here, through an implementation involving electro-optic modulators and heterodyne detection, we quantify the ranging systems trade-off between precision and non-ambiguity range (NAR) using a unique performance factor. We highlight the influence of the comb amplitude envelope on the precision with a distance measurement limited by the repetition rate of the optical comb. The influence of the combs repetition rate on the NAR and on the precision is illustrated through a setup allowing distance measurement with a tunable NAR. Finally, we demonstrate the impossibility to resolve different targets, quantify the impact on the measured distance and develop on the conditions in which non-linear effects of the interference make the measurement impossible.
△ Less
Submitted 11 February, 2022;
originally announced February 2022.
-
Application and modeling of an online distillation method to reduce krypton and argon in XENON1T
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
A. Bernard,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (129 additional authors not shown)
Abstract:
A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of…
▽ More
A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of $(360 \pm 60)$ ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fit to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove Ar-37 after its injection for a low energy calibration in XENON1T. This makes the usage of Ar-37 as a regular calibration source possible in the future. The online distillation can be applied to next-generation experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large scale detectors.
△ Less
Submitted 14 June, 2022; v1 submitted 22 December, 2021;
originally announced December 2021.
-
Emission of Single and Few Electrons in XENON1T and Limits on Light Dark Matter
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
A. Bernard,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (130 additional authors not shown)
Abstract:
Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effe…
▽ More
Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effectively be vetoed. In this work we extend previous S2-only analyses down to a single electron. From this analysis, after removing the correlated backgrounds, we observe rates < 30 events/(electron*kg*day) in the region of interest spanning 1 to 5 electrons. We derive 90% confidence upper limits for dark matter-electron scattering, first direct limits on the electric dipole, magnetic dipole, and anapole interactions, and bosonic dark matter models, where we exclude new parameter space for dark photons and solar dark photons.
△ Less
Submitted 28 June, 2022; v1 submitted 22 December, 2021;
originally announced December 2021.
-
Material radiopurity control in the XENONnT experiment
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino,
M. Clark
, et al. (128 additional authors not shown)
Abstract:
The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove…
▽ More
The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background ($\sim$17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected $^{222}$Rn activity concentration in XENONnT is determined to be 4.2$\,(^{+0.5}_{-0.7})\,μ$Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.
△ Less
Submitted 26 January, 2023; v1 submitted 10 December, 2021;
originally announced December 2021.
-
Multi-Pulse Terahertz Spectroscopy Unveils Hot Polaron Photoconductivity Dynamics in Metal-Halide Perovskites
Authors:
Xijia Zheng,
Thomas R. Hopper,
Andrei Gorodetsky,
Marios Maimaris,
Weidong Xu,
Bradley A. A. Martin,
Jarvist M. Frost,
Artem A. Bakulin
Abstract:
The behavior of hot carriers in metal-halide perovskites (MHPs) present a valuable foundation for understanding the details of carrier-phonon coupling in the materials as well as the prospective development of highly efficient hot carrier and carrier multiplication solar cells. Whilst the carrier population dynamics during cooling have been intensely studied, the evolution of the hot carrier prope…
▽ More
The behavior of hot carriers in metal-halide perovskites (MHPs) present a valuable foundation for understanding the details of carrier-phonon coupling in the materials as well as the prospective development of highly efficient hot carrier and carrier multiplication solar cells. Whilst the carrier population dynamics during cooling have been intensely studied, the evolution of the hot carrier properties, namely the hot carrier mobility, remain largely unexplored. To address this, we introduce a novel ultrafast visible pump - infrared push - terahertz probe spectroscopy (PPP-THz) to monitor the real-time conductivity dynamics of cooling carriers in methylammonium lead iodide. We find a decrease in mobility upon optically depositing energy into the carriers, which is typical of band-transport. Surprisingly, the conductivity recovery dynamics are incommensurate with the intraband relaxation measured by an analogous experiment with an infrared probe (PPP- IR), and exhibit a negligible dependence on the density of hot carriers. These results and the kinetic modelling reveal the importance of highly-localized lattice heating on the mobility of the hot electronic states. This collective polaron-lattice phenomenon may contribute to the unusual photophysics observed in MHPs and should be accounted for in devices that utilize hot carriers.
△ Less
Submitted 19 August, 2021; v1 submitted 30 June, 2021;
originally announced June 2021.
-
MPGD-based photon detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
L. García Ordóñez,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri
, et al. (7 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly de…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly developed MPGD-based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a Micromegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during the 2016 COMPASS data taking and stably operated during the 2017 run. In this paper design, construction, operation and performance aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 18 June, 2020;
originally announced June 2020.
-
Real-time digital holography of the retina by principal component analysis
Authors:
Leo Puyo,
Loic Bellonnet-Mottet,
Antoine Martin,
Francois Te,
Michel Paques,
Michael Atlan
Abstract:
We demonstrate the feasibility of high-quality digital holography of the human retina in real-time with a fast camera and commodity computer hardware. High throughput rendering of digital Fresnel holograms from optically-acquired inline interferograms is performed in conjunction with temporal demodulation by projection of hologram sequences onto a data-derived basis in order to discriminate local…
▽ More
We demonstrate the feasibility of high-quality digital holography of the human retina in real-time with a fast camera and commodity computer hardware. High throughput rendering of digital Fresnel holograms from optically-acquired inline interferograms is performed in conjunction with temporal demodulation by projection of hologram sequences onto a data-derived basis in order to discriminate local narrowband coherent detection contrasts, mostly due to blood flow and optical absorption, from spurious interferometric contributions. Digital holograms are calculated from a sustained input stream of 16-bit, 1024-by-1024-pixel interferograms recorded at up to 500 frames per second, processed by principal component analysis. This temporal signal demodulation scheme consists in the projection of stacks of 32 consecutive holograms onto a basis calculated by eigendecomposition of the matrix of their time-lagged covariance; it is performed up to 20 times per second with commodity computer hardware.
△ Less
Submitted 2 April, 2020;
originally announced April 2020.
-
Technical Design Report for the PANDA Endcap Disc DIRC
Authors:
Panda Collaboration,
F. Davi,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
F. Feldbauer,
M. Fink,
V. Freudenreich,
M. Fritsch,
F. H. Heinsius,
T. Held,
T. Holtmann,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann
, et al. (441 additional authors not shown)
Abstract:
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c.…
▽ More
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.
-
A prototype industrial laser system for cold atom inertial sensing in space
Authors:
Romain Caldani,
Sébastien Merlet,
Franck Pereira Dos Santos,
Guillaume Stern,
Anne-Sophie Martin,
Bruno Desruelle,
Vincent Ménoret
Abstract:
We present the design, realization, characterization and testing of an industrial prototype of a laser system, which is based on frequency doubling of telecom lasers and features all key functionalities to drive a cold atom space gradiometer based on the architecture proposed in [Trimeche et al, 2019]. Testing was performed by implementing the laser system onto a ground based atomic sensor current…
▽ More
We present the design, realization, characterization and testing of an industrial prototype of a laser system, which is based on frequency doubling of telecom lasers and features all key functionalities to drive a cold atom space gradiometer based on the architecture proposed in [Trimeche et al, 2019]. Testing was performed by implementing the laser system onto a ground based atomic sensor currently under development. The system reaches a Technology Readiness Level (TRL) of 4, corresponding to an operational validation in a controlled environment. The optical architecture of the system can be adapted to other space mission scenarios.
△ Less
Submitted 27 August, 2019;
originally announced August 2019.
-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. They are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also indicated.
△ Less
Submitted 20 July, 2019;
originally announced July 2019.
-
The high voltage system with pressure and temperature corrections for the novel MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
M. Bari,
F. Bradamante,
A. Bressan,
C. Chatterjee,
A. Cicuttin,
P. Ciliberti,
M. Crespo,
S. Dalla Torre,
S. Dasgupta,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Martin,
G. Menon,
L. B. Rizzuto,
Triloki,
F. Tessarotto,
Y. X. Zhao
Abstract:
The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive MicroMegas. The top surface of the first THGEM is coated with a CsI film which also acts as photo-cathode. These detectors have been successfully in operation at COMPASS since 2016. Concerning bias-voltage supply, the Thick…
▽ More
The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive MicroMegas. The top surface of the first THGEM is coated with a CsI film which also acts as photo-cathode. These detectors have been successfully in operation at COMPASS since 2016. Concerning bias-voltage supply, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MicroMegas anode is segmented into pads individually biased with positive voltage while the micromesh is grounded. In total, there are about ten different electrode types and more than 20000 electrodes supplied by more than 100 HV channels, where appropriate correlations among the applied voltages are required for the correct operation of the detectors. Therefore, a robust control system is mandatory, implemented by a custom designed software package, while commercial power supply units are used. This sophisticated control system allows to protect the detectors against errors by the operator, to monitor and log voltages and currents at 1 Hz rate, and automatically react to detector misbehaviour. In addition, a voltage compensation system has been developed to automatically adjust the biasing voltage according to environmental pressure and temperature variations, to achieve constant gain over time. This development answers to a more general need. In fact, voltage compensation is always a requirement for the stability of gaseous detectors and its need is enhanced in multi-layer ones.
In this paper, the HV system and its performance are described in details, as well as the stability of the novel MPGD-based photon detectors during the physics data taking at COMPASS.
△ Less
Submitted 4 July, 2019;
originally announced July 2019.
-
High-Rate Photon Pairs and Sequential Time-Bin Entanglement with Si$_3$N$_4$ Ring Microresonators
Authors:
Farid Samara,
Anthony Martin,
Claire Autebert,
Maxim Karpov,
Tobias J. Kippenberg,
Hugo Zbinden,
Rob Thew
Abstract:
Integrated photonics is increasing in importance for compact, robust, and scalable enabling quantum technologies. This is particularly interesting for develo** quantum communication networks, where resources need to be deployed in the field. We exploit photonic chip-based $ \rm Si_3 N_4$ ring microresonators for the generation of photon pairs with low-loss, high-noise suppression and coincidence…
▽ More
Integrated photonics is increasing in importance for compact, robust, and scalable enabling quantum technologies. This is particularly interesting for develo** quantum communication networks, where resources need to be deployed in the field. We exploit photonic chip-based $ \rm Si_3 N_4$ ring microresonators for the generation of photon pairs with low-loss, high-noise suppression and coincidence rates of $80\times 10^3\,$s$^{-1}$. A simple photonic noise characterisation technique is presented that distinguishes linear and nonlinear contributions that is useful for system design and optimisation. We then demonstrate an all-fibre $750\,$MHz clock-rate sequential Time-Bin entanglement scheme with raw interference visibilities $>\,98\,\%$.
△ Less
Submitted 22 March, 2019; v1 submitted 26 February, 2019;
originally announced February 2019.
-
Spectral noise in quantum frequency down-conversion from the visible to the telecommunication C-band
Authors:
Peter C. Strassmann,
Anthony Martin,
Nicolas Gisin,
Mikael Afzelius
Abstract:
We report a detailed study of the noise properties of a visible-to-telecom photon frequency converter based on difference frequency generation (DFG). The device converts 580 nm photons to 1541 nm using a strong pump laser at 930 nm, in a periodically poled lithium niobate ridge waveguide. The converter reaches a maximum device efficiency of 46 % (internal efficiency of 67 %) at a pump power of 250…
▽ More
We report a detailed study of the noise properties of a visible-to-telecom photon frequency converter based on difference frequency generation (DFG). The device converts 580 nm photons to 1541 nm using a strong pump laser at 930 nm, in a periodically poled lithium niobate ridge waveguide. The converter reaches a maximum device efficiency of 46 % (internal efficiency of 67 %) at a pump power of 250 mW. The noise produced by the pump laser is investigated in detail by recording the noise spectra both in the telecom and visible regimes, and measuring the power dependence of the noise rates. The noise spectrum in the telecom is very broadband, as expected from previous work on similar DFG converters. However, we also observe several narrow dips in the telecom spectrum, with corresponding peaks appearing in the 580 nm noise spectrum. These features are explained by sum frequency generation of the telecom noise at wavelengths given by the phase matching condition of different spatial modes in the waveguide. The proposed noise model is in good agreement with all the measured data, including the power-dependence of the noise rates, both in the visible and telecom regime. These results are applicable to the class of DFG converters where the pump laser wavelength is in between the input and target wavelength.
△ Less
Submitted 7 February, 2019;
originally announced February 2019.
-
Optomechanical Gigahertz Oscillator made of a Two Photon Absorption free piezoelectric III/V semiconductor
Authors:
Inès Ghorbel,
François Swiadek,
Rui Zhu,
Daniel Dolfi,
Gaëlle Lehoucq,
Aude Martin,
Grégory Moille,
Loïc Morvan,
Rémy Braive,
Sylvain Combrié,
Alfredo De Rossi
Abstract:
Oscillators in the GHz frequency range are key building blocks for telecommunication, timing and positioning applications. Operating directly in the GHz and compactness while kee** high frequency stability, is still an up-to-date challenge. Recently, optomechanical crystals, compact by nature, have demonstrated GHz frequency modes, thus gathering prerequisite features for using them as oscillato…
▽ More
Oscillators in the GHz frequency range are key building blocks for telecommunication, timing and positioning applications. Operating directly in the GHz and compactness while kee** high frequency stability, is still an up-to-date challenge. Recently, optomechanical crystals, compact by nature, have demonstrated GHz frequency modes, thus gathering prerequisite features for using them as oscillators. Here we report on the demonstration, in ambient atmospheric conditions, of an optomechanical oscillator designed with an original concept based on bichromatic one-dimensional optomechanical crystal. Self sustained oscillations directly at 3 GHz are routinely achieved with a low optical power threshold of 40 $μW$ and short-term linewidth narrowed down to 100 Hz in agreement with phase noise measurements (-113 dBc/Hz at 1 MHz from the carrier) for free running optomechanical oscillators. This oscillator is made of InGaP, low loss and TPA-free piezoelectric material which makes it valuable for optomechanics.
△ Less
Submitted 15 May, 2019; v1 submitted 17 January, 2019;
originally announced January 2019.
-
The Hybrid MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buechele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai
, et al. (6 additional authors not shown)
Abstract:
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution o…
▽ More
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution of ~ 1.8 mrad and about 10 detected photons per ring at saturation. The main aspects of their construction and commissioning, their characterization and performance figures are presented.
△ Less
Submitted 17 December, 2018;
originally announced December 2018.
-
Letter of Intent: A New QCD facility at the M2 beam line of the CERN SPS (COMPASS++/AMBER)
Authors:
B. Adams,
C. A. Aidala,
R. Akhunzyanov,
G. D. Alexeev,
M. G. Alexeev,
A. Amoroso,
V. Andrieux,
N. V. Anfimov,
V. Anosov,
A. Antoshkin,
K. Augsten,
W. Augustyniak,
C. D. R. Azevedo,
A. Azhibekov,
B. Badelek,
F. Balestra,
M. Ball,
J. Barth,
R. Beck,
Y. Bedfer,
J. Berenguer Antequera,
J. C. Bernauer,
J. Bernhard,
M. Bodlak,
P. Bordalo
, et al. (242 additional authors not shown)
Abstract:
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
△ Less
Submitted 25 January, 2019; v1 submitted 2 August, 2018;
originally announced August 2018.
-
Optimized MPGD-based Photon Detectors for high momentum particle identification at the Electron-Ion Collider
Authors:
J. Agarwala,
F. Bradamante,
A. Bressan,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
M. Gregori,
S. Levorato,
A. Martin,
G. Menon,
F. Tessarotto,
Y. Zhao
Abstract:
Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous radiators, where the challenge is the limited length of the radiator region available at a collider experiment. By selecting a photon wavelength range in the far UV domain, around 120 nm, the number of detectable photons…
▽ More
Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous radiators, where the challenge is the limited length of the radiator region available at a collider experiment. By selecting a photon wavelength range in the far UV domain, around 120 nm, the number of detectable photons can be increased. Ideal sensors are gaseous Photon Detectors (PD) with CsI photocathode, where the status of the art is represented by the MPGD-based PDs at COMPASS RICH. Detector optimization is required for the application at EIC. Here we report about a dedicated prototype where the sensor pad-size has been reduced to preserve the angular resolution. A new DAQ system based on the SRS readout electronics has been developed for the laboratory and test beam studies of the prototype.
△ Less
Submitted 5 July, 2018;
originally announced July 2018.
-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. These detectors are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also presented.
△ Less
Submitted 2 July, 2018;
originally announced July 2018.
-
The novel photon detectors based on MPGD technologies for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Maggiora,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri
, et al. (10 additional authors not shown)
Abstract:
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination…
▽ More
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination of two THGEMs and a Micromegas stage; the first THGEM, coated with a CsI layer, acts as a reflective photocathode. The signals are extracted from the anode pads by capacitive coupling and read-out by analog front-end electronics based on the APV25 chip. The new COMPASS RICH-1 photon detectors are described in detail: the detector design, the engineering aspects, the mass production, and the quality assessment are discussed. The assembly of the MPGD components and the installation of the new detectors are illustrated together with the main aspects of the commissioning. Preliminary indication of performance results are also presented.
△ Less
Submitted 16 April, 2018;
originally announced April 2018.
-
The high voltage system for the novel MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
R. Birsa,
F. Bradamante,
A. Bressan,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Martin,
G. Menon,
F. Tessarotto,
Y. Zhao
Abstract:
The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MICROMEGAS anode is segmented in pads individually biased at…
▽ More
The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MICROMEGAS anode is segmented in pads individually biased at positive voltage, while the micromesh is grounded. In total, there are ten different electrode types and more than 20000 electrodes supplied by more than 100 HV channels. Commercial power supply units are used. The original elements of the power supply system are the architecture of the voltage distribution net, the compensation, by voltage adjustment, of the effects of pressure and temperature variation affecting the detector gain and a sophisticated control software, which allows to protect the detectors against errors by the operator, to monitor and log voltages and current at 1 Hz rate and to automatically react to detector misbehaviors. The HV system and its performance are described in detail as well as the electrical stability of the detector during the operation at COMPASS.
△ Less
Submitted 5 March, 2018;
originally announced March 2018.
-
Optically transparent solid electrodes for precision Penning traps
Authors:
M. Wiesel,
G. Birkl,
M. S. Ebrahimi,
A. Martin,
W. Quint,
N. Stallkamp,
M. Vogel
Abstract:
We have conceived, built, and operated a cryogenic Penning trap with an electrically conducting yet optically transparent solid electrode. The trap, dedicated to spectroscopy and imaging of confined particles under large solid angles is of 'half-open' design with one open endcap and one closed endcap that mainly consists of a glass window coated with a highly transparent conductive layer. This arr…
▽ More
We have conceived, built, and operated a cryogenic Penning trap with an electrically conducting yet optically transparent solid electrode. The trap, dedicated to spectroscopy and imaging of confined particles under large solid angles is of 'half-open' design with one open endcap and one closed endcap that mainly consists of a glass window coated with a highly transparent conductive layer. This arrangement allows for trap** of externally or internally produced particles, yields flexible access for optical excitation and efficient light collection from the trap** region. At the same time, it is electrically closed and ensures long-term ion confinement under well-defined conditions. With its superior surface quality and its high as well as homogeneous optical transmission, the window electrode is an excellent replacement for partially transmissive electrodes that use holes, slits, metallic meshes and the like.
△ Less
Submitted 9 February, 2018;
originally announced February 2018.
-
Periodic orbits in Large Eddy Simulation of Box Turbulence
Authors:
Lennaert van Veen,
Alberto Vela Martin,
Genta Kawahara,
Tatsuya Yasuda
Abstract:
We describe and compare two time-periodic flows embedded in Large Eddy Simulation (LES) of turbulence in a three-dimensional, periodic domain subject to constant external forcing. One of these flows models the regeneration of large-scale structures that was observed in this geometry by Yasuda et al. ({\sl Fluid Dyn. Res.} {\bf 46}, 061413, 2014), who used a smaller LES filter length and thus obtai…
▽ More
We describe and compare two time-periodic flows embedded in Large Eddy Simulation (LES) of turbulence in a three-dimensional, periodic domain subject to constant external forcing. One of these flows models the regeneration of large-scale structures that was observed in this geometry by Yasuda et al. ({\sl Fluid Dyn. Res.} {\bf 46}, 061413, 2014), who used a smaller LES filter length and thus obtained a greater separation of scales of coherent motion. We speculate on the feasibility of modelling the regenerative dynamics with time-periodic solutions in such a flow, which may require novel techniques to deal with the extreme ill-conditioning of the associated boundary value problems.
△ Less
Submitted 2 February, 2018;
originally announced February 2018.
-
General framework for treating generation, propagation, and polarization of luminescence in anisotropic media
Authors:
Shane Nichols,
Melissa Tan,
Alexander Martin,
Bart Kahr
Abstract:
Complete polarimeters deliver the full polarization transfer matrix of a medium that relates input polarization states to output polarization states. In order to interpret the Mueller matrix of a luminescent medium at the emission frequency, accountings are required for polarization transformations of the medium at the excitation frequency, the light scattering event, and the polarization transfor…
▽ More
Complete polarimeters deliver the full polarization transfer matrix of a medium that relates input polarization states to output polarization states. In order to interpret the Mueller matrix of a luminescent medium at the emission frequency, accountings are required for polarization transformations of the medium at the excitation frequency, the light scattering event, and the polarization transformations at the emission frequency. A general framework for this kind of analysis is presented herein. The fluorescence Mueller matrix is expressed as a product of Mueller matrices of the medium at the excitation and emission frequencies and a scattering matrix, integrated over path length. The Stokes vector for the incident light, evolving according to the Mueller matrix of the medium at the excitation frequency, is multiplied by the scattering matrix to give a Stokes vector of the emitted light along the propagation direction. The scattering matrix is derived from an incoherent orientation ensemble average over a phenomenological scattering tensor that embodies intrinsic molecular scattering proprieties, and dynamical processes that occur during the excited state. The general framework is evaluated for three anisotropic materials carrying luminescent dye molecules including the following: a chiral fluid, a stretched polymer film, and a chiral, biaxial crystal. In the latter case, the most complex, the Mueller matrix was collected in conoscopic illumination and the fluorescence Mueller matrix, mapped in k-space, was fully simulated by the strategy outlined above. Luminescence spectroscopy has typically stood apart from the developments in polarimetry of the past two generations. This need not be indefinite.
△ Less
Submitted 26 October, 2017;
originally announced October 2017.
-
Status of COMPASS RICH-1 Upgrade with MPGD-based Photon Detectors
Authors:
M. Alexeev,
R Birsa,
F. Bradamante,
A. Bressan,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fishcher,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
K. Koenigsmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri,
F. A. Pereira
, et al. (10 additional authors not shown)
Abstract:
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are describe…
▽ More
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are described in detail.
△ Less
Submitted 25 October, 2017;
originally announced October 2017.
-
Novel MPGD based Detectors of Single Photons in COMPASS RICH-1
Authors:
J. Agarwala M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy
, et al. (12 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly dev…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly developed MPGD based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a MicroMegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during 2016 COMPASS data taking and stably operated during 2017 run. In this paper all aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 24 October, 2017;
originally announced October 2017.
-
Simulation of high temperature superconductors and experimental validation
Authors:
Marc Olm,
Santiago Badia,
Alberto F. Martín
Abstract:
In this work, we present a parallel, fully-distributed finite element numerical framework to simulate the low-frequency electromagnetic response of superconducting devices, which allows to efficiently exploit HPC platforms. We select the so-called H-formulation, which uses the magnetic field as a state variable. Nédélec elements (of arbitrary order) are required for an accurate approximation of th…
▽ More
In this work, we present a parallel, fully-distributed finite element numerical framework to simulate the low-frequency electromagnetic response of superconducting devices, which allows to efficiently exploit HPC platforms. We select the so-called H-formulation, which uses the magnetic field as a state variable. Nédélec elements (of arbitrary order) are required for an accurate approximation of the H-formulation for modelling electromagnetic fields along interfaces between regions with high contrast medium properties. An h-adaptive mesh refinement technique customized for Nédélec elements leads to a structured fine mesh in areas of interest whereas a smart coarsening is obtained in other regions. The composition of a tailored, robust, parallel nonlinear solver completes the exposition of the developed tools to tackle the problem. First, a comparison against experimental data is performed to show the availability of the finite element approximation to model the physical phenomena. Then, a selected state-of-the-art 3D benchmark is reproduced, focusing on the parallel performance of the algorithms.
△ Less
Submitted 12 April, 2018; v1 submitted 31 July, 2017;
originally announced July 2017.
-
Universal geometric constraints during epithelial jamming
Authors:
Lior Atia,
Dapeng Bi,
Yasha Sharma,
Jennifer A. Mitchel,
Bomi Gweon,
Stephan Koehler,
Stephen J. DeCamp,
Bo Lan,
Rebecca Hirsch,
Adrian F. Pegoraro,
Kyu Ha Lee,
Jacqueline Starr,
David A. Weitz,
Adam C. Martin,
**-Ah Park,
James P. Butler,
Jeffrey J. Fredberg
Abstract:
As an injury heals, an embryo develops, or a carcinoma spreads, epithelial cells systematically change their shape. In each of these processes cell shape is studied extensively, whereas variation of shape from cell-to-cell is dismissed most often as biological noise. But where do cell shape and variation of cell shape come from? Here we report that cell shape and shape variation are mutually const…
▽ More
As an injury heals, an embryo develops, or a carcinoma spreads, epithelial cells systematically change their shape. In each of these processes cell shape is studied extensively, whereas variation of shape from cell-to-cell is dismissed most often as biological noise. But where do cell shape and variation of cell shape come from? Here we report that cell shape and shape variation are mutually constrained through a relationship that is purely geometrical. That relationship is shown to govern maturation of the pseudostratified bronchial epithelial layer cultured from both non-asthmatic and asthmatic donors as well as formation of the ventral furrow in the epithelial monolayer of the Drosophila embryo in vivo. Across these and other vastly different epithelial systems, cell shape variation collapses to a family of distributions that is common to all and potentially universal. That distribution, in turn, is accounted for quantitatively by a mechanistic theory of cell-cell interaction showing that cell shape becomes progressively less elongated and less variable as the layer becomes progressively more jammed. These findings thus uncover a connection between jamming and geometry that is generic -spanning jammed living and inert systems alike- and demonstrate that proximity of the cell layer to the jammed state is the principal determinant of the most primitive features of epithelial cell shape and shape variation.
△ Less
Submitted 12 May, 2017;
originally announced May 2017.