-
Radioisotopes production using lasers: from basic science to applications
Authors:
M. R. D. Rodrigues,
A. Bonasera,
M. Scisciò,
J. A. Pérez-Hernández,
M. Ehret,
F. Filippi,
P. L. Andreoli,
M. Huault,
H. Larreur,
D. Singappuli,
D. Molloy,
D. Raffestin,
M. Alonzo,
G. G. Rapisarda,
D. Lattuada,
G. L. Guardo,
C. Verona,
Fe. Consoli,
G. Petringa,
A. McNamee,
M. La Cognata,
S. Palmerini,
T. Carriere,
M. Cipriani,
G. Di Giorgio
, et al. (15 additional authors not shown)
Abstract:
Laser technologies improved after the understanding of the Chirped Pulse Amplification (CPA) which allows energetic laser beams to be compressed to tens of femtosecond (fs) pulse durations and focused to few $μ$m. Protons of tens of MeV can be accelerated using for instance the Target Normal Sheath Acceleration (TNSA) method and focused on secondary targets. In such conditions, nuclear reactions c…
▽ More
Laser technologies improved after the understanding of the Chirped Pulse Amplification (CPA) which allows energetic laser beams to be compressed to tens of femtosecond (fs) pulse durations and focused to few $μ$m. Protons of tens of MeV can be accelerated using for instance the Target Normal Sheath Acceleration (TNSA) method and focused on secondary targets. In such conditions, nuclear reactions can occur and radioisotopes relevant for medical purposes be produced. High repetition lasers can be used to produce enough isotopes for medical applications. This route is competitive to conventional methods mostly based on accelerators. In this paper we study the production of $^{67}$Cu, $^{63}$Zn, $^{18}$F and $^{11}$C currently used in positron emission tomography (PET) and other applications. At the same time, we study the reaction $^{10}$B(p,$α$)$^{7}$Be and $^{70}$Zn(p,4n)$^{67}$Ga to put further constraints to the proton distributions at different angles and to the reaction $^{11}$B(p,$α$)$^{8}$Be relevant for energy production. The experiment was performed at the 1 petawatt (PW) laser facility at Vega III located in Salamanca-Spain. Angular distributions of radioisotopes in the forward (with respect to the laser direction) and backward directions were measured using a High Purity Germanium Detector (HPGE). Our results are reasonably reproduced by the numerical estimates following the approach of Kimura et al. (NIMA637(2011)167)
△ Less
Submitted 14 December, 2023;
originally announced December 2023.
-
Controlled transition to different proton acceleration regimes: near-critical density plasmas driven by circularly polarized few cycle pulse
Authors:
Shivani Choudhary,
Sudipta Mondal,
Daniele Margarone,
Subhendu Kahaly
Abstract:
We investigate the different facets of ion acceleration by a relativistically intense circularly polarized laser pulse interacting with thin near-critical density plasma targets. Our simulations establish that plasma density gradient and laser frequency chirp can be controlled to switch the interaction from the transparent to the opaque regimes of operation. This enables one to choose between a Ma…
▽ More
We investigate the different facets of ion acceleration by a relativistically intense circularly polarized laser pulse interacting with thin near-critical density plasma targets. Our simulations establish that plasma density gradient and laser frequency chirp can be controlled to switch the interaction from the transparent to the opaque regimes of operation. This enables one to choose between a Maxwellian like ion energy distribution with a cut-off energy, in the relativistically transparent regime, or a quasi-monoenergetic spectrum, in the opaque regime. We subsequently demonstrate that a double-layer multi-species target configuration, can be effectively utilized for optimal generation of quasi mono-energetic ion bunches of a desired species. We finally demonstrate, the feasibility of generating mono-energetic proton beams with energy peak at $\mathcal{E}\approx20\sim40$ MeV with a narrow energy spread of $Δ\mathcal{E}/\mathcal{E}\approx18-28.6\%$ confined within a divergence angle of $\sim 175$ millirad at a reasonable laser peak intensity of $I_{0}\simeq 5.4\times 10^{20}\, \mathrm{W/cm^2}$.
△ Less
Submitted 21 March, 2023;
originally announced March 2023.
-
Automated control and optimisation of laser driven ion acceleration
Authors:
B. Loughran,
M. J. V. Streeter,
H. Ahmed,
S. Astbury,
M. Balcazar,
M. Borghesi,
N. Bourgeois,
C. B. Curry,
S. J. D. Dann,
S. DiIorio,
N. P. Dover,
T. Dzelzanis,
O. C. Ettlinger,
M. Gauthier,
L. Giuffrida,
G. D. Glenn,
S. H. Glenzer,
J. S. Green,
R. J. Gray,
G. S. Hicks,
C. Hyland,
V. Istokskaia,
M. King,
D. Margarone,
O. McCusker
, et al. (10 additional authors not shown)
Abstract:
The interaction of relativistically intense lasers with opaque targets represents a highly non-linear, multi-dimensional parameter space. This limits the utility of sequential 1D scanning of experimental parameters for the optimisation of secondary radiation, although to-date this has been the accepted methodology due to low data acquisition rates. High repetition-rate (HRR) lasers augmented by ma…
▽ More
The interaction of relativistically intense lasers with opaque targets represents a highly non-linear, multi-dimensional parameter space. This limits the utility of sequential 1D scanning of experimental parameters for the optimisation of secondary radiation, although to-date this has been the accepted methodology due to low data acquisition rates. High repetition-rate (HRR) lasers augmented by machine learning present a valuable opportunity for efficient source optimisation. Here, an automated, HRR-compatible system produced high fidelity parameter scans, revealing the influence of laser intensity on target pre-heating and proton generation. A closed-loop Bayesian optimisation of maximum proton energy, through control of the laser wavefront and target position, produced proton beams with equivalent maximum energy to manually-optimized laser pulses but using only 60% of the laser energy. This demonstration of automated optimisation of laser-driven proton beams is a crucial step towards deeper physical insight and the construction of future radiation sources.
△ Less
Submitted 1 March, 2023;
originally announced March 2023.
-
Ion acceleration with few cycle relativistic laser pulses from foil targets
Authors:
Sargis Ter-Avetisyan,
Parvin Varmazyar,
Prashant K. Singh,
Joon-Gon Son,
Miklos Fule,
Valery Yu. Bychenkov,
Balazs Farkas,
Kwinten Nelissen,
Sudipta Mondal,
Daniel Papp,
Adam Borzsonyi,
Janos Csontos,
Zsolt Lecz,
Tamas Somoskoi,
Laszlo Toth,
Szabolcs Toth,
Velyhan Andriy,
Daniele Margarone,
Ales Necas,
Toshiki Tajima,
Gerard Mourou,
Gabor Szabo,
Karoly Osvay
Abstract:
Ion acceleration resulting from the interaction of 11 fs laser pulses of ~35 mJ energy with ultrahigh contrast (<10^-10), and 10^19 W/cm^2 peak intensity with foil targets made of various materials and thicknesses at normal (0-degree) and 45-degree laser incidence is investigated. The maximum energy of the protons accelerated from both the rear and front sides of the target was above 1 MeV. A conv…
▽ More
Ion acceleration resulting from the interaction of 11 fs laser pulses of ~35 mJ energy with ultrahigh contrast (<10^-10), and 10^19 W/cm^2 peak intensity with foil targets made of various materials and thicknesses at normal (0-degree) and 45-degree laser incidence is investigated. The maximum energy of the protons accelerated from both the rear and front sides of the target was above 1 MeV. A conversion efficiency from laser pulse energy to proton beam is estimated to be as high as ~1.4 % at 45-degree laser incidence using a 51 nm-thick Al target. The excellent laser contrast indicates the predominance of vacuum heating via the Brunels effect as an absorption mechanism involving a tiny pre-plasma of natural origin due to the Gaussian temporal laser pulse shape. Experimental results are in reasonable agreement with theoretical estimates where proton acceleration from the target rear into the forward direction is well explained by a TNSA-like mechanism, while proton acceleration from the target front into the backward direction can be explained by the formation of a charged cavity in a tiny pre-plasma. The exploding Coulomb field from the charged cavity also serves as a source for forward-accelerated ions at thick targets.
△ Less
Submitted 1 December, 2022;
originally announced December 2022.
-
Design of the ELIMAIA ion collection system
Authors:
F. Schillaci,
G. A. P. Cirrone,
G. Cuttone,
M. Maggiore,
L. Ando,
A. Amato,
M. Costa,
G. Gallo,
G. Korn,
G. Larosa,
R. Leanza,
R. Manna,
D. Margarone,
G. Milluzzo,
S. Pulvirenti,
F. Romano,
S. Salamone,
M. Sedita,
V. Scuderia,
A. Tramontana
Abstract:
A system of permanent magnet quadrupoles (PMQs) is going to be realized by INFNLNS to be used as a collection system for the injection of laser driven ion beams up to 60 AMeV in an energy selector based on four resistive dipoles. This system is the first element of the ELIMED (ELI-Beamlines MEDical and Multidisciplinary applications) beam transport, dosimetry and irradiation line that will be deve…
▽ More
A system of permanent magnet quadrupoles (PMQs) is going to be realized by INFNLNS to be used as a collection system for the injection of laser driven ion beams up to 60 AMeV in an energy selector based on four resistive dipoles. This system is the first element of the ELIMED (ELI-Beamlines MEDical and Multidisciplinary applications) beam transport, dosimetry and irradiation line that will be developed by INFN-LNS (It) and installed at the ELI-Beamlines facility in Prague (Cz). ELIMED will be the first users open transport beam-line where a controlled laser-driven ion beam will be used for multidisciplinary researches. The definition of well specified characteristics, both in terms of performances and field quality, of the magnetic lenses is crucial for the system realization, for the accurate study of the beam dynamics and for the proper matching with the magnetic selection system which will be designed in the next months.
Here, we report the design of the collection system and the adopted solutions in order to realize a robust system form the magnetic point of view. Moreover, the first preliminary transport simulations are also described.
△ Less
Submitted 1 January, 2022;
originally announced January 2022.
-
A new energy spectrum reconstruction method for Time-Of-Flight diagnostics of high-energy laser-driven protons
Authors:
G. Milluzzo,
V. Scuderi,
A. Alejo,
A. G. Amico,
N. Booth,
M. Borghesi,
G. A. P. Cirrone,
G. Cuttone,
D. Doria,
J. Green,
S. Kar,
G. Korn,
G. Larosa,
R. Leanza,
D. Margarone,
P. Martin,
P. McKenna,
G. Petringa,
J. Pipek,
L. Romagnani,
F. Romano,
A. Russo,
F. Schillaci
Abstract:
The Time-of-Flight (ToF) technique coupled with semiconductor-like detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full on-line beam spectral characterization. A new analysis method for reconstructing the energy spectrum of high-energy laser-driven ion beams from TOF signals is hereb…
▽ More
The Time-of-Flight (ToF) technique coupled with semiconductor-like detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full on-line beam spectral characterization. A new analysis method for reconstructing the energy spectrum of high-energy laser-driven ion beams from TOF signals is hereby presented and discussed. The proposed method takes into account the detector's working principle, through the accurate calculation of the energy loss in the detector active layer, using Monte Carlo simulations. The analysis method was validated against well-established diagnostics, such as the Thomson Parabola Spectrometer, during an experimental campaign carried out at the Rutherford Appleton Laboratory (RAL, UK) with the high-energy laser-driven protons accelerated by the VULCAN Petawatt laser.
△ Less
Submitted 4 December, 2018;
originally announced December 2018.
-
Discussing the discrepancy between analytical calculations and the observed biological effectiveness in proton boron capture therapy (pbct)
Authors:
G. A. P. Cirrone,
G. Petringa,
A. Attili,
D. Chiappara,
L. Manti,
V. Bravatà,
D. Margarone,
M. Mazzocco,
G. Cuttone
Abstract:
A work recently published experimentally demonstrates an increase in the radiobiological efficacy of clinical proton beams when a tumour is treated in the presence of a concentration of 11B. The paper, for the first time, demonstrates the potential role of the p+11B to 3α (for brevity, p-B) reaction in the biological enhancement of proton therapy effectiveness. The work reports robust experimental…
▽ More
A work recently published experimentally demonstrates an increase in the radiobiological efficacy of clinical proton beams when a tumour is treated in the presence of a concentration of 11B. The paper, for the first time, demonstrates the potential role of the p+11B to 3α (for brevity, p-B) reaction in the biological enhancement of proton therapy effectiveness. The work reports robust experimental data in terms of clonogenic cell survival and chromosomal aberrations and unambiguously shows the presence of an enhancement when cells were exposed to a clinical proton beam subject to treatment with sodium boroncaptate (BSH). Moreover, the greater occurrence of complex-type chromosomal exchanges points to the effect as due radiation of a LET (Linear Energy Transfer) greater than that of protons alone, possibly the alpha particles generated by the reaction. At the same time, we emphasized that analytical calculations, performed on the basis of the well-known total production cross section data, are not able to explain the effect in a macroscopic way, i.e. solely in terms of a trivial increase in the total dose released in the cells by the alpha-particles. In this paper, thanks to simulations and analytical calculations, we will discuss the theoretically expected alpha particle yield and the corresponding LET and RBE (Relative Biological Effectiveness) increase related to the 11B presence. We conclude that a mere calculation based on the classical concepts of integral Dose, and average LET and RBE cannot be used to justify the observed radiobiological phenomena. We, therefore, suggest that micro- and nano-dosimetric aspects must be taken into account.
△ Less
Submitted 14 October, 2018;
originally announced October 2018.
-
Response to the authors of 'On the (un)effectiveness of Proton Boron Capture in Proton Therapy'
Authors:
GAP Cirrone,
G Cuttone,
L Manti,
D. Margarone,
G Petringa,
L. Giuffrida,
A. Minopoli,
A. Picciotto,
G. Russo,
F. Cammarata,
P. Pisciotta,
F. M. Perozziello,
F. Romano,
V. Marchese,
G. Milluzzo,
V. Scuderi,
G. Cuttone,
G. Korn
Abstract:
This manuscript provides a response to a recent report by Mazzone et al. available online on arXiv that, in turn, tentatively aims at demonstrating the inefficacy of proton boron capture in hadrotherapy. We clarify that Mazzone et al. do not add any scientific or technical insights to the points extensively discussed in the original manuscript by Cirrone et al., and/or in the series of iterations…
▽ More
This manuscript provides a response to a recent report by Mazzone et al. available online on arXiv that, in turn, tentatively aims at demonstrating the inefficacy of proton boron capture in hadrotherapy. We clarify that Mazzone et al. do not add any scientific or technical insights to the points extensively discussed in the original manuscript by Cirrone et al., and/or in the series of iterations had with the Referee, which ultimately lead to the publication of our original and pioneering experimental work. Here we summarize some of the key points of the long scientific debate we had during the review process of paper by Cirrone et al., which are very similar to the considerations presented by Mazzone et al.. In conclusion, no quantitative explanation of our robust experimental achievements presented in Cirrone et al. is provided in Mazzone et al.
△ Less
Submitted 9 March, 2018;
originally announced March 2018.
-
Geant4 simulation of the ELIMED transport and dosimetry beam line for high-energy laser-driven ion beam multidisciplinary applications
Authors:
G. Milluzzo,
J. Pipek,
A. G. Amico,
G. A. P. Cirrone,
G. Cuttone,
G. Korn,
G. Larosa,
R. Leanza,
D. Margarone,
G. Petringa,
A. Russo,
F. Schillaci,
V. Scuderi,
F. Romano
Abstract:
The ELIMED (MEDical and multidisciplinary application at ELI Beamlines) beam line is being developed at INFN-LNS with the aim of transporting and selecting in energy proton and ion beams accelerated by laser-matter interaction at ELI Beamlines in Prague. It will be a section of the ELIMAIA (ELI Multidisciplinary Applications of laser-Ions Acceleration) beam line, dedicated to applications, includi…
▽ More
The ELIMED (MEDical and multidisciplinary application at ELI Beamlines) beam line is being developed at INFN-LNS with the aim of transporting and selecting in energy proton and ion beams accelerated by laser-matter interaction at ELI Beamlines in Prague. It will be a section of the ELIMAIA (ELI Multidisciplinary Applications of laser-Ions Acceleration) beam line, dedicated to applications, including the medical one, of laser-accelerated ion beams [1,2]. A Monte Carlo model has been developed to support the design of the beam line in terms of particle transport efficiency, to optimize the transport parameters at the irradiation point in air and, furthermore, to predict beam parameters in order to deliver dose distributions of clinical relevance. The application has been developed using the Geant4 [3] Monte Carlo toolkit and has been designed in a modular way in order to easily switch on/off geometrical components according to different experimental setups and users requirements, as reported in [4], describing the early-stage code and simulations. The application has been delivered to ELI Beamlines and will be available for future ELIMAIA's users as ready-to-use tool useful during experiment preparation and analysis. The final version of the developed application will be described in detail in this contribution, together with the final results, in terms of energy spectra and transmission efficiency along the in-vacuum beam line, obtained by performing end-to-end simulations.
△ Less
Submitted 11 February, 2018;
originally announced February 2018.
-
On production and asymmetric focusing of flat electron beams using rectangular capillary discharge plasmas
Authors:
G. A. Bagdasarov,
N. A. Bobrova,
A. S. Boldarev,
O. G. Olkhovskaya,
P. V. Sasorov,
V. A. Gasilov,
S. K. Barber,
S. S. Bulanov,
A. J. Gonsalves,
C. B. Schroeder,
J. van Tilborg,
E. Esarey,
W. P. Leemans,
T. Levato,
D. Margarone,
G. Korn,
M. Kando,
S. V. Bulanov
Abstract:
A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique is proposed. This method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissip…
▽ More
A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique is proposed. This method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. Large aspect ratio rectangular capillaries might be used to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.
△ Less
Submitted 7 December, 2017; v1 submitted 20 October, 2017;
originally announced October 2017.
-
Plasma Equilibrium inside Various Cross-Section Capillary Discharges
Authors:
Gennadiy Bagdasarov,
Pavel Sasorov,
Alexey Boldarev,
Olga Olkhovskaya,
Vladimir Gasilov,
Anthony J. Gonsalves,
Samuel Barber,
Stepan Bulanov,
Carl B. Schroeder,
Jeroen van Tilborg,
Eric Esarey,
Wim P. Leemans,
Tadzio Levato,
Daniele Margarone,
Georg Korn,
Sergei V. Bulanov
Abstract:
Plasma properties inside a hydrogen-filled capillary discharge waveguide were modeled with dissipative magnetohydrodynamic simulations to enable analysis of capillaries of circular and square cross-sections implying that square capillaries can be used to guide circularly-symmetric laser beams. When the quasistationary stage of the discharge is reached, the plasma and temperature in the vicinity of…
▽ More
Plasma properties inside a hydrogen-filled capillary discharge waveguide were modeled with dissipative magnetohydrodynamic simulations to enable analysis of capillaries of circular and square cross-sections implying that square capillaries can be used to guide circularly-symmetric laser beams. When the quasistationary stage of the discharge is reached, the plasma and temperature in the vicinity of the capillary axis has almost the same profile for both the circular and square capillaries. The effect of cross-section on the electron beam focusing properties were studied using the simulation-derived magnetic field map. Particle tracking simulations showed only slight effects on the electron beam symmetry in the horizontal and diagonal directions for square capillary.
△ Less
Submitted 29 March, 2017; v1 submitted 24 March, 2017;
originally announced March 2017.
-
Laser beam coupling with capillary discharge plasma for laser wakefield acceleration applications
Authors:
Gennadiy Bagdasarov,
Pavel Sasorov,
Vladimir Gasilov,
Alexey Boldarev,
Olga Olkhovskaya,
Carlo Benedetti,
Stepan Bulanov,
Anthony Joseph Gonsalves,
Hann-Shin Mao,
Carl B. Schroeder,
Jeroen van Tilborg,
Eric Esarey,
Wim P. Leemans,
Tadzio Levato,
Daniele Margarone,
Georg Korn
Abstract:
One of the most robust methods, demonstrated up to date, of accelerating electron beams by laser-plasma sources is the utilization of plasma channels generated by the capillary discharges. These channels, i.e., plasma columns with a minimum density along the laser pulse propagation axis, may optically guide short laser pulses, thereby increasing the acceleration length, leading to a more efficient…
▽ More
One of the most robust methods, demonstrated up to date, of accelerating electron beams by laser-plasma sources is the utilization of plasma channels generated by the capillary discharges. These channels, i.e., plasma columns with a minimum density along the laser pulse propagation axis, may optically guide short laser pulses, thereby increasing the acceleration length, leading to a more efficient electron acceleration. Although the spatial structure of the installation is simple in principle, there may be some important effects caused by the open ends of the capillary, by the supplying channels etc., which require a detailed 3D modeling of the processes taking place in order to get a detailed understanding and improve the operation. However, the discharge plasma, being one of the most crucial components of the laser-plasma accelerator, is not simulated with the accuracy and resolution required to advance this promising technology. In the present work, such simulations are performed using the code MARPLE. First, the process of the capillary filling with a cold hydrogen before the discharge is fired, through the side supply channels is simulated. The main goal of this simulation is to get a spatial distribution of the filling gas in the region near the open ends of the capillary. A realistic geometry is used for this and the next stage simulations, including the insulators, the supplying channels as well as the electrodes. Second, the simulation of the capillary discharge is performed with the goal to obtain a time-dependent spatial distribution of the electron density near the open ends of the capillary as well as inside the capillary. Finally, to evaluate effectiveness of the beam coupling with the channeling plasma wave guide and electron acceleration, modeling of laser-plasma interaction was performed with the code INF&RNO
△ Less
Submitted 23 March, 2017;
originally announced March 2017.
-
Nuclear fusion enhances cancer cell killing efficacy in a protontherapy model
Authors:
GAP Cirrone,
L Manti,
D Margarone,
L Giuffrida,
A. Picciotto,
G. Cuttone,
G. Korn,
V. Marchese,
G. Milluzzo,
G. Petringa,
F. Perozziello,
F. Romano,
V. Scuderi
Abstract:
Protontherapy is hadrontherapy fastest-growing modality and a pillar in the battle against cancer. Hadrontherapy superiority lies in its inverted depth-dose profile, hence tumour-confined irradiation. Protons, however, lack distinct radiobiological advantages over photons or electrons. Higher LET (Linear Energy Transfer) $^{12}$C ions can overcome cancer radioresistance: DNA lesion complexity incr…
▽ More
Protontherapy is hadrontherapy fastest-growing modality and a pillar in the battle against cancer. Hadrontherapy superiority lies in its inverted depth-dose profile, hence tumour-confined irradiation. Protons, however, lack distinct radiobiological advantages over photons or electrons. Higher LET (Linear Energy Transfer) $^{12}$C ions can overcome cancer radioresistance: DNA lesion complexity increases with LET, resulting in efficient cell killing, i.e. higher Relative Biological Effectiveness (RBE). However, economic and radiobiological issues hamper $^{12}$C-ion clinical amenability. Thus, enhancing proton RBE is desirable. To this end, we exploited the p + $^{11}$B $\rightarrow$3$α$ reaction to generate high-LET alpha particles with a clinical proton beam. To maximize the reaction rate, we used sodium borocaptate (BSH) with natural boron content. Boron-Neutron Capture Therapy (BNCT) uses $^{10}$B-enriched BSH for neutron irradiation-triggered alpha-particles. We recorded significantly increased cellular lethality and chromosome aberration complexity. A strategy combining protontherapy ballistic precision with the higher RBE promised by BNCT and $^{12}$C-ion therapy is thus demonstrated.
△ Less
Submitted 25 January, 2017;
originally announced January 2017.
-
Prompt gamma ray diagnostics and enhanced hadron-therapy using neutron-free nuclear reactions
Authors:
L. Giuffrida,
D. Margarone,
G. A. P. Cirrone,
A. Picciotto,
G. Korn
Abstract:
We propose a series of simulations about the potential use of Boron isotopes to trigger neutron-free (aneutronic) nuclear reactions in cancer cells through the interaction with an incoming energetic proton beam, thus resulting in the emission of characteristic prompt gamma radiation (429 keV, 718 keV and 1435 keV). Furthermore assuming that the Boron isotopes are absorbed in cancer cells, the thre…
▽ More
We propose a series of simulations about the potential use of Boron isotopes to trigger neutron-free (aneutronic) nuclear reactions in cancer cells through the interaction with an incoming energetic proton beam, thus resulting in the emission of characteristic prompt gamma radiation (429 keV, 718 keV and 1435 keV). Furthermore assuming that the Boron isotopes are absorbed in cancer cells, the three alpha-particles produced in each p-11B aneutronic nuclear fusion reactions can potentially result in the enhancement of the biological dose absorbed in the tumor region since these multi-MeV alpha-particles are stopped inside the single cancer cell, thus allowing to spare the surrounding tissues. Although a similar approach based on the use of 11B nuclei has been proposed in [1], our work demonstrate, using Monte Carlo simulations, the crucial importance of the use of 10B nuclei (in a solution containing also 11B) for the generation of prompt gamma-rays, which can be applied to medical imaging. In fact, we demonstrate that the use of 10B nuclei can enhance the intensity of the 718 keV gamma-ray peak more than 30 times compared to the solution containing only 11B nuclei. A detailed explanation of the origin of the different prompt gamma-rays, as well as of their application as real-time diagnostics during a potential cancer treatment, is here discussed.
△ Less
Submitted 24 August, 2016;
originally announced August 2016.
-
Avalanche boron fusion by laser picosecond block ignition with magnetic trap** for clean and economic reactor
Authors:
H. Hora,
G. Korn,
S. Eliezer,
N. Nissim P. Lalousis,
L. Giuffrida,
D. Margarone,
A. Picciotto,
G. H. Miley,
S. Moustaizis,
J. -M. Martinez-Val,
C. P. J. Barty,
G. J. Kirchhoff
Abstract:
After the very long consideration of the ideal energy source by fusion of the protons of light hydrogen with the boron isotope 11 (boron fusion HB11) the very first two independent measurements of very high reaction gains by lasers basically opens a fundamental breakthrough. The non-thermal plasma block ignition with extremely high power laser pulses above petawatt of picosecond duration in combin…
▽ More
After the very long consideration of the ideal energy source by fusion of the protons of light hydrogen with the boron isotope 11 (boron fusion HB11) the very first two independent measurements of very high reaction gains by lasers basically opens a fundamental breakthrough. The non-thermal plasma block ignition with extremely high power laser pulses above petawatt of picosecond duration in combination with up to ten kilotesla magnetic fields for trap** has to be combined to use the measured high gains as proof of an avalanche reaction for an environmentally clean, low cost and lasting energy source as potential option against global warming. The unique HB11 avalanche reaction is are now based on elastic collisions of helium nuclei (alpha particles) limited only to a reactor for controlled fusion energy during a very short time within a very small volume.
△ Less
Submitted 4 March, 2016;
originally announced March 2016.
-
Picosecond-petawatt laser-block ignition of avalanche boron fusion by ultrahigh acceleration and ultrahigh magnetic fields
Authors:
H. Hora,
P. Lalousis,
L. Giuffrida,
D. Margarone,
G. Korn,
S. Eliezer,
G. H. Mley,
S. Moustizis,
G. Mourou,
C. P. J. Barty
Abstract:
Fusion energy from reacting hydrogen (protons) with the boron isotope 11 (HB11) resulting in three stable helium nuclei, is without problem of nuclear radiation in contrast to DT fusion. But the HB11 reaction driven by nanosecond laser pulses with thermal compression and ignition by lasers is extremely difficult. This changed radically when irradiation with picosecond laser pulses produces a non-t…
▽ More
Fusion energy from reacting hydrogen (protons) with the boron isotope 11 (HB11) resulting in three stable helium nuclei, is without problem of nuclear radiation in contrast to DT fusion. But the HB11 reaction driven by nanosecond laser pulses with thermal compression and ignition by lasers is extremely difficult. This changed radically when irradiation with picosecond laser pulses produces a non-thermal plasma block ignition with ultrahigh acceleration. This uses the nonlinear (ponderomotive) force to surprisingly resulting in same thresholds as DT fusion even under pessimistic assumption of binary reactions. After evaluation of reactions trapped cylindrically by kilotesla magnetic fields and using the measured highly increased HB11 fusion gains for the proof of an avalanche of the three alphas in secondary reactions, possibilities for an absolutely clean energy source at competitive costs were concluded.
△ Less
Submitted 25 October, 2015; v1 submitted 7 October, 2015;
originally announced October 2015.
-
Helium-3 and Helium-4 acceleration by high power laser pulses for hadron therapy
Authors:
S. S. Bulanov,
E. Esarey,
C. B. Schroeder,
W. P. Leemans,
S. V. Bulanov,
D. Margarone,
G. Korn,
T. Haberer
Abstract:
The laser driven acceleration of ions is considered a promising candidate for an ion source for hadron therapy of oncological diseases. Though proton and carbon ion sources are conventionally used for therapy, other light ions can also be utilized. Whereas carbon ions require 400 MeV per nucleon to reach the same penetration depth as 250 MeV protons, helium ions require only 250 MeV per nucleon, w…
▽ More
The laser driven acceleration of ions is considered a promising candidate for an ion source for hadron therapy of oncological diseases. Though proton and carbon ion sources are conventionally used for therapy, other light ions can also be utilized. Whereas carbon ions require 400 MeV per nucleon to reach the same penetration depth as 250 MeV protons, helium ions require only 250 MeV per nucleon, which is the lowest energy per nucleon among the light ions. This fact along with the larger biological damage to cancer cells achieved by helium ions, than that by protons, makes this species an interesting candidate for the laser driven ion source. Two mechanisms (Magnetic Vortex Acceleration and hole-boring Radiation Pressure Acceleration) of PW-class laser driven ion acceleration from liquid and gaseous helium targets are studied with the goal of producing 250 MeV per nucleon helium ion beams that meet the hadron therapy requirements. We show that He3 ions, having almost the same penetration depth as He4 with the same energy per nucleon, require less laser power to be accelerated to the required energy for the hadron therapy.
△ Less
Submitted 14 May, 2015;
originally announced May 2015.
-
Increased efficiency of ion acceleration by using femtosecond laser pulses at higher harmonic frequency
Authors:
Jan Psikal,
Ondrej Klimo,
Stefan Weber,
Daniele Margarone
Abstract:
The influence of laser frequency on laser-driven ion acceleration is investigated by means of two-dimensional particle-in-cell simulations. When ultrashort intense laser pulse at higher harmonic frequency irradiates a thin solid foil, the target may become relativistically transparent for significantly lower laser pulse intensity compared to irradiation at fundamental laser frequency. The relativi…
▽ More
The influence of laser frequency on laser-driven ion acceleration is investigated by means of two-dimensional particle-in-cell simulations. When ultrashort intense laser pulse at higher harmonic frequency irradiates a thin solid foil, the target may become relativistically transparent for significantly lower laser pulse intensity compared to irradiation at fundamental laser frequency. The relativistically induced transparency results in an enhanced heating of hot electrons as well as increased maximum energies of accelerated ions and their numbers. Our simulation results have shown the increase of maximum proton energy and of the number of high-energy protons by a factor of 2 after the interaction of an ultrashort laser pulse of maximum intensity $7 \times 10^{21}~\rm{W/cm^2}$ with a fully ionized plastic foil of realistic density and of optimal thickness between $100~\rm{nm}$ and $200~\rm{nm}$ when switching from the fundamental frequency to the third harmonics.
△ Less
Submitted 28 July, 2014; v1 submitted 19 May, 2014;
originally announced May 2014.