-
Parametrization of Non-Bonded Force Field Terms for Metal-Organic Frameworks Using Machine Learning Approach
Authors:
Vadim V. Korolev,
Yurii M. Nevolin,
Thomas A. Manz,
Pavel V. Protsenko
Abstract:
The enormous structural and chemical diversity of metal-organic frameworks (MOFs) forces researchers to actively use simulation techniques on an equal footing with experiments. MOFs are widely known for outstanding adsorption properties, so precise description of host-guest interactions is essential for high-throughput screening aimed at ranking the most promising candidates. However, highly accur…
▽ More
The enormous structural and chemical diversity of metal-organic frameworks (MOFs) forces researchers to actively use simulation techniques on an equal footing with experiments. MOFs are widely known for outstanding adsorption properties, so precise description of host-guest interactions is essential for high-throughput screening aimed at ranking the most promising candidates. However, highly accurate ab initio calculations cannot be routinely applied to model thousands of structures due to the demanding computational costs. On the other side, methods based on force field (FF) parametrization suffer from low transferability. To resolve this accuracy-efficiency dilemma, we apply the machine learning (ML) approach. The trained models reproduce atom-in-material quantities, including partial charges, polarizabilities, dispersion coefficients, quantum Drude oscillator and electron cloud parameters within the accuracy of underlying density functional theory method. The aforementioned FF precursors make it possible to thoroughly describe non-covalent interactions typical for MOF-adsorbate systems: electrostatic, dispersion, polarization, and short-range repulsion. The presented approach can also significantly facilitate hybrid atomistic simulations/ML workflows.
△ Less
Submitted 13 September, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
A thermodynamic description of turbulence as a source of stochastic kinetic energy for 3D self-assembly
Authors:
Per A. Löthman,
Tijmen A. G. Hageman,
Miko C. Elwenspoek,
Gijs J. M. Krijnen,
Massimo Mastrangeli,
Andreas Manz,
Leon Abelmann
Abstract:
We investigate to what extent one can use a thermodynamic description of turbulent flow as a source of stochastic kinetic energy for three-dimensional self-assembly of magnetically interacting macroscopic particles. We confirm that the speed of the objects in the flow field generated in our system obeys the Maxwell--Boltzmann distribution, and their random walk can be defined by a diffusion coeffi…
▽ More
We investigate to what extent one can use a thermodynamic description of turbulent flow as a source of stochastic kinetic energy for three-dimensional self-assembly of magnetically interacting macroscopic particles. We confirm that the speed of the objects in the flow field generated in our system obeys the Maxwell--Boltzmann distribution, and their random walk can be defined by a diffusion coefficient following from the Einstein relation. However, we discovered that the analogy with Brownian dynamics breaks down when considering the directional components of the velocity. For the vectorial components, neither the equipartition theorem, nor the Einstein relation is obeyed. Moreover, the kinetic energy estimated from the random walk of individual objects is one order of magnitude higher than the value estimated from Boltzmann statistics on the interaction between two spheres with embedded magnets. These results show that introducing stochastic kinetic energy into a self-assembly process by means of turbulent flow can to a great extent be described by standard thermodynamic theory, but anisotropies and the specific nature of the interactions need to be taken into account.
△ Less
Submitted 7 June, 2019;
originally announced June 2019.
-
Long term observation of Magnetospirillum gryphiswaldense in a microfluidic channel
Authors:
Tijmen A. G. Hageman,
Marc. P. Pichel,
Per A. Löthman,
Jiung Cho,
Miri Choi,
Nuriye Korkmaz,
Andreas Manz,
Leon Abelmann
Abstract:
We controlled and observed individual magnetotactic bacteria (Magnetospirillum gryphiswaldense) inside a 5 μm high microfluidic channel for over four hours. After a period of constant velocity, the duration of which varied between bacteria, all observed bacteria showed a gradual decrease in their velocity of about 25 nm/s$^2$. After coming to a full stop, different behaviour was observed, ranging…
▽ More
We controlled and observed individual magnetotactic bacteria (Magnetospirillum gryphiswaldense) inside a 5 μm high microfluidic channel for over four hours. After a period of constant velocity, the duration of which varied between bacteria, all observed bacteria showed a gradual decrease in their velocity of about 25 nm/s$^2$. After coming to a full stop, different behaviour was observed, ranging from rotation around the centre of mass synchronous with the direction of the external magnetic field, to being completely immobile. Our results suggest that the influence of the high intensity illumination and the presence of the channel walls are important parameters to consider when performing observations of such long duration.
△ Less
Submitted 21 February, 2019;
originally announced February 2019.
-
Additional contributions from: Nobel Symposium 162 - Microfluidics
Authors:
Stefan Löfås,
Amy E. Herr,
Jianhua Qin,
Tuomas Knowles,
Takehiko Kitamori,
Hang Lu,
David J. Beebe,
Jongyoon Han,
James Landers,
Andreas Manz,
Roland Zengerle,
David A. Weitz,
Johan Elf,
Thomas Laurell
Abstract:
Series of short contributions that are part of Nobel Symposium 162 - Microfluidics arXiv:1712.08369.
Series of short contributions that are part of Nobel Symposium 162 - Microfluidics arXiv:1712.08369.
△ Less
Submitted 22 February, 2018;
originally announced February 2018.
-
Magnetic Response of Magnetospirillum Gryphiswaldense
Authors:
M. P. Pichel,
T. A. G. Hageman,
I. S. M. Khalil,
A. Manz,
L. Abelmann
Abstract:
In this study we modelled and measured the U-turn trajectories of individual magnetotactic bacteria under the application of rotating magnetic fields, ranging in ampitude from 1 to 12 mT. The model is based on the balance between rotational drag and magnetic torque. For accurate verification of this model, bacteria were observed inside 5 m tall microfluidic channels, so that they remained in focus…
▽ More
In this study we modelled and measured the U-turn trajectories of individual magnetotactic bacteria under the application of rotating magnetic fields, ranging in ampitude from 1 to 12 mT. The model is based on the balance between rotational drag and magnetic torque. For accurate verification of this model, bacteria were observed inside 5 m tall microfluidic channels, so that they remained in focus during the entire trajectory. From the analysis of hundreds of trajectories and accurate measurements of bacteria and magnetosome chain dimensions, we confirmed that the model is correct within measurement error. The resulting average rate of rotation of Magnetospirillum Gryphiswaldense is 0.74 +- 0.03 rad/mTs.
△ Less
Submitted 1 October, 2017;
originally announced October 2017.
-
Macroscopic equivalence for microscopic motion in a turbulence driven three-dimensional self-assembly reactor
Authors:
T. A. G. Hageman,
P. A. Löthman,
M. Dirnberger,
M. Elwenspoek,
A. Manz,
L. Abelmann
Abstract:
We built and characterised a macroscopic self-assembly reactor that agitates magnetic, centimeter-sized particles with a turbulent water flow. By scaling up the self-assembly processes to the centimeter-scale, the characteristic time constant scale also drastically increases. This makes the system a physical simulator of microscopic self-assembly, where the interaction of inserted particles are ea…
▽ More
We built and characterised a macroscopic self-assembly reactor that agitates magnetic, centimeter-sized particles with a turbulent water flow. By scaling up the self-assembly processes to the centimeter-scale, the characteristic time constant scale also drastically increases. This makes the system a physical simulator of microscopic self-assembly, where the interaction of inserted particles are easily observable. Trajectory analysis of single particles reveals their velocity to be a Maxwell-Boltzmann distribution and it shows that their average squared displacement over time can be modelled by a confined random walk model, demonstrating a high level of similarity to Brownian motion. The interaction of two particles has been modelled and verified experimentally by observing the distance between two particles over time. The disturbing energy (analogue to temperature) that was obtained experimentally increases with sphere size, and differs by an order of magnitude between single-sphere and two-sphere systems (approximately 80 $\mathrm{μJ}$ versus 6.5 $\mathrm{μJ}$, respectively).
△ Less
Submitted 12 September, 2017;
originally announced September 2017.
-
Comment on "Minimal Basis Iterative Stockholder: Atoms in Molecules for Force-Field Development"
Authors:
Thomas A. Manz
Abstract:
Verstraelen et al. (J. Chem. Theory Comput. 12 (2016) 3894-3912) recently introduced a new method for partitioning the electron density of a material into constituent atoms. Their approach falls within the class of atomic population analysis methods called stockholder charge partitioning methods in which a material electron distribution is divided into overlap** atoms. The Minimal Basis Iterativ…
▽ More
Verstraelen et al. (J. Chem. Theory Comput. 12 (2016) 3894-3912) recently introduced a new method for partitioning the electron density of a material into constituent atoms. Their approach falls within the class of atomic population analysis methods called stockholder charge partitioning methods in which a material electron distribution is divided into overlap** atoms. The Minimal Basis Iterative Stockholder (MBIS) method proposed by Verstraelen et al. composes the pro-atom density as a sum of exponential functions, where the number of exponential functions equals that element's row in the Periodic Table. Specifically, one exponential function is used for H and He, two for Li through Ne, three for Na through Ar, etc. In the MBIS method, the exponential functions parameters defining the pro-atom density are optimized in a self-consistent iterative procedure. Close examination reveals some important anomalies in the article by Verstaelen et al. The purpose of this comment article is to bring these important issues to readers' attention and to start a discussion of them.
△ Less
Submitted 6 January, 2017;
originally announced January 2017.
-
Construction and Test of the Precision Drift Chambers for the ATLAS Muon Spectrometer
Authors:
F. Bauer,
W. Blum,
U. Bratzler,
H. Dietl,
S. Kotov,
H. Kroha,
Th. Lagouri,
A. Manz,
A. Ostapchuk,
R. Richter,
S. Schael,
S. Chouridou,
M. Deile,
O. Kortner,
A. Staude,
R. Stroehmer,
T. Trefzger
Abstract:
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurised drift tubes on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 microns with a single-tube resolution of at least 80 microns and a sense wire posi…
▽ More
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurised drift tubes on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 microns with a single-tube resolution of at least 80 microns and a sense wire positioning accu- racy of 20 ?microns (rms). The feasibility was demonstrated with the full-scale prototype of one of the largest MDT chambers with 432 drift tubes of 3.8 m length. For the ATLAS muon spectrometer, 88 chambers of this type have to be built. The first chamber has been completed with a wire positioning accuracy of 14 microns (rms).
△ Less
Submitted 8 April, 2016;
originally announced April 2016.
-
Construction and Test of MDT Chambers for the ATLAS Muon Spectrometer
Authors:
F. Bauer,
U. Bratzler,
H. Dietl,
H. Kroha,
Th. Lagouri,
A. Manz,
A. Ostapchuk,
R. Richter,
S. Schael,
S. Chouridou,
M. Deile,
O. Kortner,
A. Staude,
R. Stroehmer,
T. Trefzger
Abstract:
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the AT- LAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical monitoring system to correct for deformations. The full-scale prototype of a large MDT chamber has been constructed with methods suitable for large-scale production. X-ray me…
▽ More
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the AT- LAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical monitoring system to correct for deformations. The full-scale prototype of a large MDT chamber has been constructed with methods suitable for large-scale production. X-ray measurements at CERN showed a positioning accuracy of the sense wires in the chamber of better than the required 20 ?microns (rms). The performance of the chamber was studied in a muon beam at CERN. Chamber production for ATLAS now has started.
△ Less
Submitted 7 April, 2016;
originally announced April 2016.
-
Large-Scale Production of Monitored Drift Tube Chambers for the ATLAS Muon Spectrometer
Authors:
F. Bauer,
S. Horvat,
O. Kortner,
H. Kroha,
A. Manz,
S. Mohrdieck,
R. Richter,
V. Zhuravlov
Abstract:
Precision drift tube chambers with a sense wire positioning accuracy of better than 20 microns are under construction for the ATLAS muon spectrometer. 70% of the 88 large chambers for the outermost layer of the central part of the spectrometer have been assembled. Measurements during chamber construction of the positions of the sense wires and of the sensors for the optical alignment monitoring sy…
▽ More
Precision drift tube chambers with a sense wire positioning accuracy of better than 20 microns are under construction for the ATLAS muon spectrometer. 70% of the 88 large chambers for the outermost layer of the central part of the spectrometer have been assembled. Measurements during chamber construction of the positions of the sense wires and of the sensors for the optical alignment monitoring system demonstrate that the requirements for the mechanical precision of the chambers are fulfilled.
△ Less
Submitted 1 April, 2016;
originally announced April 2016.
-
Performance of the ATLAS Precision Muon Chambers under LHC Operating Conditions
Authors:
M. Deile,
H. Dietl,
J. Dubbert,
S. Horvat,
O. Kortner,
H. Kroha,
A. Manz,
S. Mohrdieck,
F. Rauscher,
R. Richter,
A. Staude
Abstract:
For the muon spectrometer of the ATLAS detector at the large hadron collider (LHC), large drift chambers consisting of 6 to 8 layers of pressurized drift tubes are used for precision tracking covering an active area of 5000 m2 in the toroidal field of superconducting air core magnets. The chambers have to provide a spatial resolution of 41 microns with Ar:CO2 (93:7) gas mixture at an absolute pres…
▽ More
For the muon spectrometer of the ATLAS detector at the large hadron collider (LHC), large drift chambers consisting of 6 to 8 layers of pressurized drift tubes are used for precision tracking covering an active area of 5000 m2 in the toroidal field of superconducting air core magnets. The chambers have to provide a spatial resolution of 41 microns with Ar:CO2 (93:7) gas mixture at an absolute pressure of 3 bar and gas gain of 2?104. The environment in which the chambers will be operated is characterized by high neutron and background with counting rates of up to 100 per square cm and second. The resolution and efficiency of a chamber from the serial production for ATLAS has been investigated in a 100 GeV muon beam at photon irradiation rates as expected during LHC operation. A silicon strip detector telescope was used as external reference in the beam. The spatial resolution of a chamber is degraded by 4 ?m at the highest background rate. The detection efficiency of the drift tubes is unchanged under irradiation. A tracking efficiency of 98% at the highest rates has been demonstrated.
△ Less
Submitted 1 April, 2016;
originally announced April 2016.
-
Resolution and Efficiency of the ATLAS Muon Drift-Tube Chambers at High Background Rates
Authors:
M. Deile,
J. Dubbert,
S. Horvat,
O. Kortner,
H. Kroha,
A. Manz,
S. Mohrdieck-Moeck,
F. Rauscher,
R. Richter,
A. Staude,
W. Stiller
Abstract:
The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of up to 990 Hz/square cm which corresponds to twice the highest background rate expected in ATLAS. A silicon strip detector telescope was used as external referenc…
▽ More
The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of up to 990 Hz/square cm which corresponds to twice the highest background rate expected in ATLAS. A silicon strip detector telescope was used as external reference in the beam. The pulse-height measurement of the read-out electronics was used to perform time-slewing corrections which lead to an improvement of the average drift-tube resolution from 104 microns to 82 microns without irradiation and from 128 microns to 108 microns at the maximum expected rate. The measured drift-tube efficiency agrees with the expectation from the dead time of the read-out electronics up to the maximum expected rate.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
Computationally Designed Zirconium Organometallic Catalyst for Direct Epoxidation of Alkenes without Allylic H Atoms: Aromatic Linkage Eliminates Formation of Inert Octahedral Complexes
Authors:
Bo Yang,
Thomas A. Manz
Abstract:
We used density functional theory to computationally design a Zr organometallic catalyst for selectively oxidizing substrates using molecular oxygen as oxidant without coreductant. Each selective oxidation cycle involves four general steps: (a) a peroxo or weakly adsorbed O2 group releases an O atom to substrate to form substrate oxide and an oxo group, (b) an oxygen molecule adds to the oxo group…
▽ More
We used density functional theory to computationally design a Zr organometallic catalyst for selectively oxidizing substrates using molecular oxygen as oxidant without coreductant. Each selective oxidation cycle involves four general steps: (a) a peroxo or weakly adsorbed O2 group releases an O atom to substrate to form substrate oxide and an oxo group, (b) an oxygen molecule adds to the oxo group to generate an eta2-ozone group, (c) the eta2-ozone group rearranges to form an eta3-ozone group, and (d) the eta3-ozone group releases an O atom to substrate to form substrate oxide and regenerate the peroxo or weakly adsorbed O2 group. This catalyst could potentially be synthesized via the condensation reaction Zr(N(R)R')4 + 2 C6H4-1,6-(N(C6H3-2',6'-(CH(CH3)2)2)OH)2 --> Zr(C6H4-1,6-(N(C6H3-2',6'-(CH(CH3)2)2)O)2)2 [aka Zr_Benzol catalyst] + 4 N(R)(R')H where R and R' are CH3, CH2CH3, or other alkyl groups. For direct ethylene epoxidation, the computed enthalpic energetic span (i.e., effective activation energy for the entire catalytic cycle) is 27.1 kcal/mol, which is one of the lowest values for catalysts studied to date. We study reaction mechanisms and the stability of different catalyst forms as a function of the oxygen atom chemical potential. Notably, an aromatic linkage in each ligand prevents this catalyst from deactivating to form an inactive octahedral-like structure that contains the same atoms as the dioxo complex, Zr(Ligand)2(O)2. Due to a side reaction that can transfer an allylic H atom from alkene to catalyst, this catalyst is useful for directly epoxidizing alkenes such as ethylene that do not contain allylic H atoms. To better understand the reaction chemistry, we computed net atomic charges and bond orders for the two catalytically relevant reaction cycles. These results quantify electron transfer and bond forming and breaking during the catalytic process.
△ Less
Submitted 30 December, 2015;
originally announced December 2015.
-
DDEC6: A Method for Computing Even-Tempered Net Atomic Charges in Periodic and Nonperiodic Materials
Authors:
Thomas A. Manz,
Nidia Gabaldon Limas
Abstract:
Net atomic charges (NACs) are widely used in all chemical sciences to concisely summarize key information about the partitioning of electrons among atoms in materials. Although widely used, there is currently no atomic population analysis method suitable for being used as a default method in quantum chemistry programs. To address this challenge, we introduce a new atoms-in-materials method with th…
▽ More
Net atomic charges (NACs) are widely used in all chemical sciences to concisely summarize key information about the partitioning of electrons among atoms in materials. Although widely used, there is currently no atomic population analysis method suitable for being used as a default method in quantum chemistry programs. To address this challenge, we introduce a new atoms-in-materials method with the following nine properties: (1) exactly one electron distribution is assigned to each atom, (2) core electrons are assigned to the correct host atom, (3) NACs are formally independent of the basis set type because they are functionals of the total electron distribution, (4) the assigned atomic electron distributions give an efficiently converging polyatomic multipole expansion, (5) the assigned NACs usually follow Pauling scale electronegativity trends, (6) NACs for a particular element have good transferability among different conformations that are equivalently bonded, (7) the assigned NACs are chemically consistent with the assigned atomic spin moments, (8) the method has predictably rapid and robust convergence to a unique solution, and (9) the computational cost of charge partitioning scales linearly with increasing system size. Across a broad range of material types, the DDEC6 NACs reproduced electron transfer trends, core electron binding energy shift trends, and electrostatic potentials across multiple system conformations with excellent accuracy compared to other charge assignment methods. Due to non-nuclear attractors, Bader's quantum chemical topology could not assign NACs for some of these materials. The DDEC6 method alleviates the bifurcation or runaway charges problem exhibited by earlier DDEC variants and the Iterative Hirshfeld method. These characteristics make the DDEC6 method ideally suited for use as a default charge assignment method in quantum chemistry programs.
△ Less
Submitted 23 December, 2015;
originally announced December 2015.
-
Towards Gigayear Storage Using a Silicon-Nitride/Tungsten Based Medium
Authors:
Jeroen de Vries,
Dimitri Schellenberg,
Leon Abelmann,
Andreas Manz,
Miko Elwenspoek
Abstract:
Current digital data storage systems are able to store huge amounts of data. Even though the data density of digital information storage has increased tremendously over the last few decades, the data longevity is limited to only a few decades. If we want to preserve anything about the human race which can outlast the human race itself, we require a data storage medium designed to last for 1 millio…
▽ More
Current digital data storage systems are able to store huge amounts of data. Even though the data density of digital information storage has increased tremendously over the last few decades, the data longevity is limited to only a few decades. If we want to preserve anything about the human race which can outlast the human race itself, we require a data storage medium designed to last for 1 million to 1 billion years. In this paper a medium is investigated consisting of tungsten encapsulated by siliconnitride which, according to elevated temperature tests, will last for well over the suggested time.
△ Less
Submitted 9 October, 2013;
originally announced October 2013.
-
Precision Drift Chambers for the Atlas Muon Spectrometer
Authors:
S. Horvat,
O. Kortner,
H. Kroha,
A. Manz,
S. Mohrdieck,
V. Zhuravlov
Abstract:
ATLAS is a detector under construction to explore the physics at the Large Hadron Collider at CERN. It has a muon spectrometer with an excellent momentum resolution of 3-10%, provided by three layers of precision monitored-drift-tube chambers in a toroidal magnetic field. A single drift tube measures a track point with a mean resolution close to 100 micron, even at the expected high neutron and…
▽ More
ATLAS is a detector under construction to explore the physics at the Large Hadron Collider at CERN. It has a muon spectrometer with an excellent momentum resolution of 3-10%, provided by three layers of precision monitored-drift-tube chambers in a toroidal magnetic field. A single drift tube measures a track point with a mean resolution close to 100 micron, even at the expected high neutron and gamma background rates. The tubes are positioned within the chamber with an accuracy of 20 microns, achieved by elaborate construction and assembly monitoring procedures.
△ Less
Submitted 26 August, 2003;
originally announced August 2003.