Super Phantoms: advanced models for testing medical imaging technologies
Authors:
Srirang Manohar,
Ioannis Sechopoulos,
Mark A. Anastasio,
Lena Maier-Hein,
Rajiv,
Gupta
Abstract:
Phantoms are test objects used for initial testing and optimization of medical imaging techniques, but these rarely capture the complex properties of the tissue. Here we introduce super phantoms, that surpass standard phantoms being able to replicate complex anatomic and functional imaging properties of tissues and organs. These super phantoms can be computer models, inanimate physical objects, or…
▽ More
Phantoms are test objects used for initial testing and optimization of medical imaging techniques, but these rarely capture the complex properties of the tissue. Here we introduce super phantoms, that surpass standard phantoms being able to replicate complex anatomic and functional imaging properties of tissues and organs. These super phantoms can be computer models, inanimate physical objects, or ex-vivo organs. Testing on these super phantoms, will enable iterative improvements well before in-vivo studies, fostering innovation. We illustrate super phantom examples, address development challenges, and envision centralized facilities supporting multiple institutions in applying these models for medical advancements.
△ Less
Submitted 8 April, 2024; v1 submitted 24 August, 2023;
originally announced August 2023.
-
Fully three-dimensional sound speed-corrected multi-wavelength photoacoustic breast tomography
Authors:
M. Dantuma,
F. Lucka,
S. C. Kruitwagen,
A. Javaherian,
L. Alink,
R. P. Pompe van Meerdervoort,
M. Nanninga,
T. J. P. M. Op 't Root,
B. De Santi,
J. Budisky,
G. Bordovsky,
E. Coffy,
M. Wilm,
T. Kasponas,
S. H. Aarnink,
L. F. de Geus-Oei,
F. Brochin,
T. Martinez,
A. Michailovas,
W. Muller Kobold,
J. Jaros,
J. Veltman,
B. Cox,
S. Manohar
Abstract:
Photoacoustic tomography is a contrast agent-free imaging technique capable of visualizing blood vessels and tumor-associated vascularization in breast tissue. While sophisticated breast imaging systems have been recently developed, there is yet much to be gained in imaging depth, image quality and tissue characterization capability before clinical translation is possible. In response, we have dev…
▽ More
Photoacoustic tomography is a contrast agent-free imaging technique capable of visualizing blood vessels and tumor-associated vascularization in breast tissue. While sophisticated breast imaging systems have been recently developed, there is yet much to be gained in imaging depth, image quality and tissue characterization capability before clinical translation is possible. In response, we have developed a hybrid photoacoustic and ultrasound-transmission tomographic system PAM3. The photoacoustic component has for the first time three-dimensional multi-wavelength imaging capability, and implements substantial technical advancements in critical hardware and software sub-systems. The ultrasound component enables for the first time, a three-dimensional sound speed map of the breast to be incorporated in photoacoustic reconstruction to correct for inhomogeneities, enabling accurate target recovery. The results demonstrate the deepest photoacoustic breast imaging to date namely 48 mm, with a more uniform field of view than hitherto, and an isotropic spatial resolution that rivals that of Magnetic Resonance Imaging. The in vivo performance achieved, and the diagnostic value of interrogating angiogenesis-driven optical contrast as well as tumor mass sound speed contrast, gives confidence in the system's clinical potential.
△ Less
Submitted 13 August, 2023;
originally announced August 2023.
-
An anthropomorphic thyroid phantom for ultrasound-guided radiofrequency ablation of nodules
Authors:
Tim Boers,
Wyger Brink,
Leonardo Bianchi,
Paola Saccomandi,
Johan van Hespen,
Germen Wennemars,
Sicco Braak,
Michel Versluis,
Srirang Manohar
Abstract:
Background: Needle-based procedures such as fine needle aspiration (FNA) and thermal ablation, are often applied for thyroid nodule diagnosis and therapeutic purposes, respectively. With blood vessels and nerves nearby, these procedures can pose risks in damaging surrounding critical structures. Purpose: The development and validation of innovative strategies to manage these risks require a test o…
▽ More
Background: Needle-based procedures such as fine needle aspiration (FNA) and thermal ablation, are often applied for thyroid nodule diagnosis and therapeutic purposes, respectively. With blood vessels and nerves nearby, these procedures can pose risks in damaging surrounding critical structures. Purpose: The development and validation of innovative strategies to manage these risks require a test object with well-characterized physical properties. For this work, we focus on the application of ultrasound-guided thermal radio-frequency ablation (RFA). Methods: We have developed an anthropomorphic phantom mimicking the thyroid and surrounding anatomical and physiological structures that are relevant to ultrasound-guided thermal ablation. The phantom was composed of a mixture of polyacrylamide, water, and egg white extract and was cast using molds in multiple steps. The thermal, acoustical, and electrical characteristics were experimentally validated. The ablation zones were analyzed via non-destructive T2-weighted MRI scans utilizing the relaxometry changes of coagulated egg albumen, and the temperature distribution was monitored using an array of fiber Bragg sensors. Results: The physical properties of the phantom were verified both on ultrasound as well as its response to thermal ablation. The final temperature achieved (92°C), the median percentage of the nodule ablated (82.1%), the median volume ablated outside the nodule (0.8 mL), and the median number of critical structures affected (0) were quantified. Conclusion: An anthropomorphic phantom that can provide a realistic model for development and training in ultrasound-guided needle-based thermal interventions for thyroid nodules has been presented. In the future, this model can also be extended to novel needle-based diagnostic procedures.
△ Less
Submitted 21 July, 2023;
originally announced July 2023.
-
A method for delineation of bone surfaces in photoacoustic computed tomography of the finger
Authors:
Samir Biswas,
Peter van Es,
Wiendelt Steenbergen,
Srirang Manohar
Abstract:
Photoacoustic imaging of interphalangeal peripheral joints is of interest in the context of using the synovial membrane as a surrogate marker of rheumatoid arthritis. Previous work has shown that ultrasound produced by absorption of light at the epidermis reflects on the bone surfaces within the finger. When the reflected signals are backprojected in the region of interest, artifacts are produced,…
▽ More
Photoacoustic imaging of interphalangeal peripheral joints is of interest in the context of using the synovial membrane as a surrogate marker of rheumatoid arthritis. Previous work has shown that ultrasound produced by absorption of light at the epidermis reflects on the bone surfaces within the finger. When the reflected signals are backprojected in the region of interest, artifacts are produced, confounding interpretation of the images. In this work, we present an approach where the photoacoustic signals known to originate from the epidermis, are treated as virtual ultrasound transmitters, and a separate reconstruction is performed as in ultrasound reflection imaging. This allows us to identify the bone surfaces. Further, the identification of the joint space is important as this provides a landmark to localize a region-of-interest in seeking the inflamed synovial membrane. The ability to delineate bone surfaces allows us not only to identify the artifacts, but also to identify the interphalangeal joint space without recourse to new US hardware or a new measurement. We test the approach on phantoms and on a healthy human finger.
△ Less
Submitted 6 June, 2015;
originally announced June 2015.
-
Initial results of finger imaging using Photoacoustic Computed Tomography
Authors:
Peter van Es,
Samir K. Biswas,
Hein J. Bernelot Moens,
Wiendelt Steenbergen,
Srirang Manohar
Abstract:
We present a photoacoustic computed tomography investigation on a healthy human finger, to image blood vessels with a focus on vascularity across the interphalangeal joints. The cross-sectional images were acquired using an imager specifically developed for this purpose. The images show rich detail of the digital blood vessels with diameters between 100 $μ$m and 1.5 mm in various orientations and…
▽ More
We present a photoacoustic computed tomography investigation on a healthy human finger, to image blood vessels with a focus on vascularity across the interphalangeal joints. The cross-sectional images were acquired using an imager specifically developed for this purpose. The images show rich detail of the digital blood vessels with diameters between 100 $μ$m and 1.5 mm in various orientations and at various depths. Different vascular layers in the skin including the subpapillary plexus could also be visualized. Acoustic reflections on the finger bone of photoacoustic signals from skin were visible in sequential slice images along the finger except at the location of the joint gaps. Not unexpectedly, the healthy synovial membrane at the joint gaps was not detected due to its small size and normal vascularization. Future research will concentrate on studying digits afflicted with rheumatoid arthritis to detect the inflamed synovium with its heightened vascularization, whose characteristics are potential markers for disease activity.
△ Less
Submitted 20 June, 2014;
originally announced June 2014.
-
A new acoustic lens material for large area detectors in photoacoustic breast tomography
Authors:
Wenfeng Xia,
Daniele Piras,
Johan C. G. van Hespen,
Wiendelt Steenbergen,
Srirang Manohar
Abstract:
Acoustic lenses made of acrylic plastic (PMMA) have been used to enlarge the acceptance angle of sensitive large surface area detectors and improve lateral resolution. However, PMMA lenses introduce image artifacts due to ultrasound internal reflections within the lenses. In this work we investigated this issue proposing a new lens material Stycast 1090SI. We characterized the acoustic properties…
▽ More
Acoustic lenses made of acrylic plastic (PMMA) have been used to enlarge the acceptance angle of sensitive large surface area detectors and improve lateral resolution. However, PMMA lenses introduce image artifacts due to ultrasound internal reflections within the lenses. In this work we investigated this issue proposing a new lens material Stycast 1090SI. We characterized the acoustic properties of the proposed material in comparison with PMMA. Detector performance using negative lenses with the two materials, was tested using finite element simulation and experiment. Further the image quality of a photoacoustic tomography system was studied using k-Wave simulation and experiment. Our acoustic characterization showed that Stycast 1090SI has tissue-like acoustic impedance, high speed of sound and low acoustic attenuation. Both acoustic lenses show significant enlargement of detector acceptance angle and lateral resolution improvement. However, image artifacts induced by acoustic lenses are reduced using the proposed lens compared to PMMA lens.
△ Less
Submitted 17 May, 2013;
originally announced May 2013.
-
The 'nanobig rods' class of gold nanorods: optimized dimensions for improved in vivo therapeutic and imaging efficacy
Authors:
Constantin Ungureanu,
Gerben A. Koning,
Ton G. van Leeuwen,
Srirang Manohar
Abstract:
Currently, gold nanorods can be synthesized in a wide range of sizes. However, for intended biological applications gold nanorods with approximate dimensions 50 nm x 15 nm are used. We investigate by computer simulation the effect of particle dimensions on the optical and thermal properties in the context of the specific applications of photoacoustic imaging. In addition we discuss the influence o…
▽ More
Currently, gold nanorods can be synthesized in a wide range of sizes. However, for intended biological applications gold nanorods with approximate dimensions 50 nm x 15 nm are used. We investigate by computer simulation the effect of particle dimensions on the optical and thermal properties in the context of the specific applications of photoacoustic imaging. In addition we discuss the influence of particle size in overcoming the following biophysical barriers when administrated in vivo: extravasation, avoidance of uptake by organs of the reticuloendothelial system, penetration through the interstitium, binding capability and uptake by the target cells. Although more complex biological influences can be introduced in future analysis, the present work illustrates that larger gold nanorods, designated by us as "nanobig rods", may perform relatively better at meeting the requirements for successful in vivo applications compared to their smaller counterparts which are conventionally used.
△ Less
Submitted 3 April, 2013; v1 submitted 29 March, 2013;
originally announced March 2013.
-
An optimized ultrasound detector for photoacoustic breast tomography
Authors:
Wenfeng Xia,
Daniele Piras,
Johan Van Hespen,
Spiridon Van Veldhoven,
Christian Prins,
Ton Van Leeuwen,
Wiendelt Steenbergen,
Srirang Manohar
Abstract:
Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the expected photoacoustic frequency bandwidth (a few MHz to tens of kHz) is inversely propo…
▽ More
Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the expected photoacoustic frequency bandwidth (a few MHz to tens of kHz) is inversely proportional to the dimensions of light absorbing structures (0.5 to 10+ mm), proper choices of materials and their geometries, and proper considerations in design have to be made for optimal photoacoustic detectors. In this study, we design and evaluate a specialized ultrasound detector for photoacoustic mammography. Based on the required detector sensitivity and its frequency response, a selection of active material and matching layers and their geometries is made leading to a functional detector models. By iteration between simulation of detector performances, fabrication and experimental characterization of functional models an optimized implementation is made and evaluated. The experimental results of the designed first and second functional detectors matched with the simulations. In subsequent bare piezoelectric samples the effect of lateral resonances was addressed and their influence minimized by sub-dicing the samples. Consequently, using simulations, the final optimized detector could be designed, with a center frequency of 1 MHz and a -6 dB bandwidth of ~80%. The minimum detectable pressure was measured to be 0.5 Pa, which will facilitate deeper imaging compared to the currrent systems. The detector should be capable of detecting vascularized tumors with resolution of 1-2 mm. Further improvements by proper electrical grounding and shielding and implementation of this design into an arrayed detector will pave the way for clinical applications of photoacoustic mammography.
△ Less
Submitted 13 February, 2013; v1 submitted 11 December, 2012;
originally announced December 2012.
-
Speed-of-sound compensated photoacoustic tomography for accurate imaging
Authors:
Jithin Jose,
Rene G. H. Willemink,
Wiendelt Steenbergen,
Cornelis H. Slump,
Ton G. van Leeuwen,
Srirang Manohar
Abstract:
In most photoacoustic (PA) measurements, variations in speed-of-sound (SOS) of the subject are neglected under the assumption of acoustic homogeneity. Biological tissue with spatially heterogeneous SOS cannot be accurately reconstructed under this assumption. We present experimental and image reconstruction methods with which 2-D SOS distributions can be accurately acquired and reconstructed, and…
▽ More
In most photoacoustic (PA) measurements, variations in speed-of-sound (SOS) of the subject are neglected under the assumption of acoustic homogeneity. Biological tissue with spatially heterogeneous SOS cannot be accurately reconstructed under this assumption. We present experimental and image reconstruction methods with which 2-D SOS distributions can be accurately acquired and reconstructed, and with which the SOS map can be used subsequently to reconstruct highly accurate PA tomograms. We begin with a 2-D iterative reconstruction approach in an ultrasound transmission tomography (UTT) setting, which uses ray refracted paths instead of straight ray paths to recover accurate SOS images of the subject. Subsequently, we use the SOS distribution in a new 2-D iterative approach, where refraction of rays originating from PA sources are accounted for in accurately retrieving the distribution of these sources. Both the SOS reconstruction and SOS-compensated PA reconstruction methods utilize the Eikonal equation to model acoustic wavefront propagation, which is solved using a high accuracy fast marching method (HAFMM). We validate the new reconstruction algorithms using numerical phantoms. For experiments we use the PER-PACT method which can be used to simultaneously acquire SOS and PA data from subjects. We test the reconstruction algorithms using experimental data acquired with the PER-PACT setup from challenging physical phantoms. The results show that it is important to take SOS inhomogeneities into account. The iterative reconstruction algorithms, that model acoustic refractive effects, yield artifact-free highly accurate images. Our approach of using the hybrid measurement method and the new reconstruction algorithms, is successful in substantially improving the quality of PA images with a minimization of blurring and artefacts.
△ Less
Submitted 30 October, 2012; v1 submitted 6 June, 2012;
originally announced June 2012.