Deconvolution in Fluorescence Lifetime imaging microscopy (FLIM)
Authors:
Varun Mannam,
Xiaotong Yuan,
Scott Howard
Abstract:
Fluorescence lifetime imaging microscopy (FLIM) is an important technique to understand the chemical micro-environment in cells and tissues since it provides additional contrast compared to conventional fluorescence imaging. When two fluorophores within a diffraction limit are excited, the resulting emission leads to non-linear spatial distortion and localization effects in intensity (magnitude) a…
▽ More
Fluorescence lifetime imaging microscopy (FLIM) is an important technique to understand the chemical micro-environment in cells and tissues since it provides additional contrast compared to conventional fluorescence imaging. When two fluorophores within a diffraction limit are excited, the resulting emission leads to non-linear spatial distortion and localization effects in intensity (magnitude) and lifetime (phase) components. To address this issue, in this work, we provide a theoretical model for convolution in FLIM to describe how the resulting behavior differs from conventional fluorescence microscopy. We then present a Richardson-Lucy (RL) based deconvolution including total variation (TV) regularization method to correct for the distortions in FLIM measurements due to optical convolution, and experimentally demonstrate this FLIM deconvolution method on a multi-photon microscopy (MPM)-FLIM images of fluorescent-labeled fixed bovine pulmonary arterial endothelial (BPAE) cells.
△ Less
Submitted 16 January, 2022;
originally announced January 2022.
Low dosage 3D volume fluorescence microscopy imaging using compressive sensing
Authors:
Varun Mannam,
Jacob Brandt,
Cody J. Smith,
Scott Howard
Abstract:
Fluorescence microscopy has been a significant tool to observe long-term imaging of embryos (in vivo) growth over time. However, cumulative exposure is phototoxic to such sensitive live samples. While techniques like light-sheet fluorescence microscopy (LSFM) allow for reduced exposure, it is not well suited for deep imaging models. Other computational techniques are computationally expensive and…
▽ More
Fluorescence microscopy has been a significant tool to observe long-term imaging of embryos (in vivo) growth over time. However, cumulative exposure is phototoxic to such sensitive live samples. While techniques like light-sheet fluorescence microscopy (LSFM) allow for reduced exposure, it is not well suited for deep imaging models. Other computational techniques are computationally expensive and often lack restoration quality. To address this challenge, one can use various low-dosage imaging techniques that are developed to achieve the 3D volume reconstruction using a few slices in the axial direction (z-axis); however, they often lack restoration quality. Also, acquiring dense images (with small steps) in the axial direction is computationally expensive. To address this challenge, we present a compressive sensing (CS) based approach to fully reconstruct 3D volumes with the same signal-to-noise ratio (SNR) with less than half of the excitation dosage. We present the theory and experimentally validate the approach. To demonstrate our technique, we capture a 3D volume of the RFP labeled neurons in the zebrafish embryo spinal cord (30um thickness) with the axial sampling of 0.1um using a confocal microscope. From the results, we observe the CS-based approach achieves accurate 3D volume reconstruction from less than 20% of the entire stack optical sections. The developed CS-based methodology in this work can be easily applied to other deep imaging modalities such as two-photon and light-sheet microscopy, where reducing sample photo-toxicity is a critical challenge.
△ Less
Submitted 3 January, 2022;
originally announced January 2022.
Design of the Single Balanced Mixer (Using HSMS-281x Diode) and Measurements
Authors:
Varun Mannam
Abstract:
We designed the Mixer operating at 2.4 GHz for WIFI-band using ADS software and fabricated using Rogers 4350B substrate. We designed the single-balanced mixer using the diode (HSMS-281x model). We measured the isolation across all ports of the mixer. We measured the conversion loss of the mixer. We performed the non-linear measurements, which include IM3 vs frequency. The performance metrics are c…
▽ More
We designed the Mixer operating at 2.4 GHz for WIFI-band using ADS software and fabricated using Rogers 4350B substrate. We designed the single-balanced mixer using the diode (HSMS-281x model). We measured the isolation across all ports of the mixer. We measured the conversion loss of the mixer. We performed the non-linear measurements, which include IM3 vs frequency. The performance metrics are compared with the data-sheet values and explained if any discrepancy exists.
△ Less
Submitted 10 February, 2021;
originally announced February 2021.