-
Absolute light yield of the EJ-204 plastic scintillator
Authors:
J. A. Brown,
T. A. Laplace,
B. L. Goldblum,
J. J. Manfredi,
T. S. Johnson,
F. Moretti,
A. Venkatraman
Abstract:
The absolute light yield of a scintillator, defined as the number of scintillation photons produced per unit energy deposited, is a useful quantity for scintillator development, research, and applications. Yet, literature data on the absolute light yield of organic scintillators are limited. The goal of this work is to assess the suitability of the EJ-204 plastic scintillator from Eljen Technology…
▽ More
The absolute light yield of a scintillator, defined as the number of scintillation photons produced per unit energy deposited, is a useful quantity for scintillator development, research, and applications. Yet, literature data on the absolute light yield of organic scintillators are limited. The goal of this work is to assess the suitability of the EJ-204 plastic scintillator from Eljen Technology to serve as a reference standard for measurements of the absolute light yield of organic scintillators. Four EJ-204 samples were examined: two manufactured approximately four months prior and stored in high-purity nitrogen, and two aged approximately eleven years and stored in ambient air. The scintillator response was measured using a large-area avalanche photodiode calibrated using low energy $γ$-ray and X-ray sources. The product of the quantum efficiency of the photodetector and light collection efficiency of the housing was characterized using an experimentally-benchmarked optical photon simulation. The average absolute light yield of the fresh samples, 9100 $\pm$ 400 photons per MeV, is lower than the manufacturer-reported value of 10400 photons per MeV. Moreover, the aged samples demonstrated significantly lower light yields, deviating from the manufacturer specification by as much as 26\%. These results are consistent with recent work showcasing environmental aging in plastic scintillators and suggest that experimenters should use caution when deploying plastic scintillators in photon counting applications.
△ Less
Submitted 28 May, 2023;
originally announced May 2023.
-
Measurement of proton light yield of water-based liquid scintillator
Authors:
E. J. Callaghan,
B. L. Goldblum,
J. A. Brown,
T. A. Laplace,
J. J. Manfredi,
M. Yeh,
G. D. Orebi Gann
Abstract:
The proton light yield of liquid scintillators is an important property in the context of their use in large-scale neutrino experiments, with direct implications for neutrino-proton scattering measurements and the discrimination of fast neutrons from inverse beta-decay coincidence signals. This work presents the first measurement of the proton light yield of a water-based liquid scintillator (WbLS…
▽ More
The proton light yield of liquid scintillators is an important property in the context of their use in large-scale neutrino experiments, with direct implications for neutrino-proton scattering measurements and the discrimination of fast neutrons from inverse beta-decay coincidence signals. This work presents the first measurement of the proton light yield of a water-based liquid scintillator (WbLS) formulated from 5% linear alkyl benzene (LAB), at energies below 20 MeV, as well as a measurement of the proton light yield of a pure LAB + 2 g/L 2,5-diphenyloxazole (PPO) mixture (LABPPO). The measurements were performed using a double time-of-flight method and a pulsed neutron beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. The proton light yields were measured relative to that of a 477 keV electron. The relative proton light yield of WbLS was approximately 3.8% lower than that of LABPPO, itself exhibiting a relative proton light yield $15-20\%$ higher than previous measurements of an analogous anoxic sample. The observed quenching is not compatible with the Birks model for either material, but is well described with the addition of Chou's bimolecular quenching term.
△ Less
Submitted 7 October, 2022;
originally announced October 2022.
-
Design and Characterization of an Optically-Segmented Single Volume Scatter Camera Module
Authors:
Kevin Keefe,
Hassam Alhajaji,
Erik Brubaker,
Andrew Druetzler,
Aline Galindo-Tellez,
John Learned,
Paul Maggi,
Juan J. Manfredi,
Kurtis Nishimura,
Bejamin Pinto Souza,
John Steele,
Melinda Sweany,
Eric Takahashi
Abstract:
The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for nuclear non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each…
▽ More
The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for nuclear non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each measuring 0.5 cm$\times$0.5 cm$\times$20 cm. The scintillator array is coupled to two custom Silicon Photomultiplier (SiPM) boards consisting of a 2$\times$8 array of SensL J-Series-60035 Silicon Photomultipliers, which are read out by a custom 16 channel DRS-4 based digitizer board. The electrical crosstalk between SiPMs within the electronics chain is measured as 0.76% $\pm$ 0.11% among all 16 channels. We report the detector response of one module including interaction position, time, and energy, using two different optical coupling materials: EJ-560 silicone rubber optical coupling pads and EJ-550 optical coupling grease. We present results in terms of the overall mean and standard deviation of the z-position reconstruction and interaction time resolutions for all 16 bars in the module. We observed the z-position resolution for gamma interactions in the 0.3 MeVee to 0.4 MeVee range to be 2.24 cm$\pm$1.10 cm and 1.45 cm$\pm$0.19 cm for silicone optical coupling pad and optical grease, respectively. The observed interaction time resolution is 265 ps$\pm$29 ps and 235 ps$\pm$10 ps for silicone optical coupling pad and optical grease, respectively.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
Simultaneous measurement of organic scintillator response to carbon and proton recoils
Authors:
T. A. Laplace,
B. L. Goldblum,
J. J. Manfredi,
J. A. Brown,
D. L. Bleuel,
C. A. Brand,
G. Gabella,
J. Gordon,
E. Brubaker
Abstract:
Background: Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Purpose: Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield o…
▽ More
Background: Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Purpose: Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. Method: A 33~MeV $^{2}$H$^{+}$ beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was im**ed upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yield of the organic scintillators, wherein the light output associated with the recoil particle was determined using $np$ and $n$C elastic scattering kinematics. Results: The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1~MeV and 2 to 5~MeV, respectively for EJ-309, and 0.2 to 0.5~MeV and 1 to 4~MeV, respectively for EJ-204. Conclusions: These data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
Proton light yield of fast plastic scintillators for neutron imaging
Authors:
J. J. Manfredi,
B. L. Goldblum,
T. A. Laplace,
G. Gabella,
J. Gordon,
A. O'Brien,
S. Chowdhury,
J. A. Brown,
E. Brubaker
Abstract:
Plastic organic scintillators have been tailored in composition to achieve ultra-fast temporal response, thereby enabling the design and development of fast neutron detection systems with high timing resolution. Eljen Technology's plastic organic scintillators -- EJ-230, EJ-232, and EJ-232Q -- are prospective candidates for use in emerging neutron imaging systems, where fast timing is paramount. T…
▽ More
Plastic organic scintillators have been tailored in composition to achieve ultra-fast temporal response, thereby enabling the design and development of fast neutron detection systems with high timing resolution. Eljen Technology's plastic organic scintillators -- EJ-230, EJ-232, and EJ-232Q -- are prospective candidates for use in emerging neutron imaging systems, where fast timing is paramount. To support the neutron response characterization of these materials, the relative proton light yields of EJ-230, EJ-232, and EJ-232Q were measured at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a broad-spectrum neutron source and a double time-of-flight technique, the proton light yield relations were obtained over a proton recoil energy range of approximately 300 keV to 4 MeV. The EJ-230, EJ-232, and EJ-232Q scintillators exhibited similar proton light yield relations to each other as well as to other plastic scintillators with the same polymer base material. A comparison of the relative proton light yield of different sized cylindrical EJ-232 and EJ-232Q scintillators also revealed consistent results. This work provides key input data for the realistic computational modeling of neutron detection technologies employing these materials, thereby supporting new capabilities in near-field radionuclide detection for national security applications.
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
Design and Calibration of an Optically Segmented Single Volume Scatter Camera for Neutron Imaging
Authors:
A. Galindo-Tellez,
K. Keefe,
E. Adamek,
E. Brubaker,
B. Crow,
R. Dorrill,
A. Druetzler,
C. J. Felix,
N. Kaneshige,
J. G. Learned,
J. J. Manfredi,
K. Nishimura,
B. Pinto Souza,
D. Schoen,
M. Sweany
Abstract:
The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5 mm $\times$ 5 mm $\times$ 200 mm and individually wrapped in Teflon tape. The scintillator array is opticall…
▽ More
The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5 mm $\times$ 5 mm $\times$ 200 mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6 $\times$ 6 mm J-Series sensors arranged in an 8 $\times$ 8 array. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 30 ps to 90 ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using $^{22}$Na and $^{90}$Sr, respectively, reporting an average resolution of (12.07$\pm$0.03) mm for energy depositions between 900 keVee and 1000 keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of (14.86$\pm$0.29) mm for depositions between 900 keVee and 1000 keVee. The coincident time resolution reported between pairs of bars measured up to 400 ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.
△ Less
Submitted 17 February, 2021; v1 submitted 4 February, 2021;
originally announced February 2021.
-
Neutron Response of the EJ-254 Boron-Loaded Plastic Scintillator
Authors:
Gino Gabella,
Bethany L. Goldblum,
Thibault A. Laplace,
Juan J. Manfredi,
Joseph Gordon,
Zachary W. Sweger,
Edith Bourret
Abstract:
Organic scintillators doped with capture agents provide a detectable signal for neutrons over a broad energy range. This work characterizes the fast and slow neutron response of EJ-254, an organic plastic scintillator with 5% natural boron loading by weight. For fast neutrons, the primary mechanism for light generation in organic scintillators is n-p elastic scattering. To study the fast neutron r…
▽ More
Organic scintillators doped with capture agents provide a detectable signal for neutrons over a broad energy range. This work characterizes the fast and slow neutron response of EJ-254, an organic plastic scintillator with 5% natural boron loading by weight. For fast neutrons, the primary mechanism for light generation in organic scintillators is n-p elastic scattering. To study the fast neutron response, the proton light yield of EJ-254 was measured at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a broad-spectrum neutron source and a double time-of-flight technique, the EJ-254 proton light yield was obtained over the energy range of approximately 270 keV to 4.5 MeV and determined to be in agreement with other plastic scintillators comprised of the same polymer base. To isolate the slow neutron response, an AmBe source with polyethylene moderator was made incident on the EJ-254 scintillator surrounded by an array of EJ-309 observation detectors. Events in the EJ-254 target coincident with the signature 477.6 keV $γ$ ray (resulting from deexcitation of the residual $^{7}$Li nucleus following boron neutron capture) were identified. Pulse shape discrimination was used to evaluate the temporal differences in the response of EJ-254 scintillation signals arising from $γ$-ray and fast/slow neutron interactions. Clear separation between $γ$-ray and fast neutrons signals was not achieved and the neutron capture feature was observed to overlap both the $γ$-ray and fast neutron bands. Taking into account the electron light nonproportionality, the neutron-capture light yield in EJ-254 was determined to be 89.4$\pm$1.1 keVee.
△ Less
Submitted 6 January, 2021;
originally announced January 2021.
-
Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass
Authors:
T. A. Laplace,
B. L. Goldblum,
J. E. Bevins,
D. L. Bleuel,
E. Bourret,
J. A. Brown,
E. J. Callaghan,
J. S. Carlson,
P. L. Feng,
G. Gabella,
K. P. Harrig,
J. J. Manfredi,
C. Moore,
F. Moretti,
M. Shinner,
A. Sweet,
Z. W. Sweger
Abstract:
An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the $^{137}$Cs Compton edge location. The proton light yield was measured…
▽ More
An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the $^{137}$Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV$-$3.2 MeV), EJ-276 (170 keV$-$4.9 MeV), and the organic glass (50 keV$-$20 MeV). Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. With these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.
△ Less
Submitted 3 November, 2020;
originally announced November 2020.
-
Scintillator light yield measurements with waveform digitizers
Authors:
T. A. Laplace,
B. L. Goldblum,
J. A. Brown,
J. J. Manfredi
Abstract:
The proton light yield of organic scintillators has been measured extensively in recent years using fast waveform digitizers and large discrepancies exist in the values reported by different authors. In this letter, we address principles of digital signal processing that must be considered when conducting scintillator light yield measurements. Digitized waveform pulse height values are only propor…
▽ More
The proton light yield of organic scintillators has been measured extensively in recent years using fast waveform digitizers and large discrepancies exist in the values reported by different authors. In this letter, we address principles of digital signal processing that must be considered when conducting scintillator light yield measurements. Digitized waveform pulse height values are only proportional to the amount of scintillation light if the temporal shape of the scintillation pulse is independent of the amount of energy deposited. This is not the case for scintillation pulses resulting from fast neutron interactions in organic scintillators. Authors measuring proton light yield should therefore report pulse integral values and ensure that the integration length is long enough to capture most of the scintillation light.
△ Less
Submitted 15 September, 2020;
originally announced September 2020.