Single photoelectron identification with Incom LAPPD 38
Authors:
S. P. Malace,
S. Wood
Abstract:
Incom Inc. Large Area Picosecond Photodetector (LAPPD) 38 has been tested at Jefferson Lab to identify single-photoelectron signals to assess the potential of this type of device for future applications in Cherenkov light detection. Single-photoelectron signals were clearly detected if a tight collimation of photons im**ing on the photocathode was used compared to the pixelation of the charge co…
▽ More
Incom Inc. Large Area Picosecond Photodetector (LAPPD) 38 has been tested at Jefferson Lab to identify single-photoelectron signals to assess the potential of this type of device for future applications in Cherenkov light detection. Single-photoelectron signals were clearly detected if a tight collimation of photons im**ing on the photocathode was used compared to the pixelation of the charge collection signal board.
△ Less
Submitted 28 June, 2021; v1 submitted 29 April, 2021;
originally announced April 2021.
Studies of single-photoelectron response and of performance in magnetic field of a H8500C-03 photomultiplier tube
Authors:
S. P. Malace,
B. D. Sawatzky,
H. Gao
Abstract:
We studied the single-photoelectron detection capabilities of a multianode photomultiplier tube H8500C-03 and its performance in high magnetic field. Our results show that the device can readily resolve signals at the single photoelectron level making it suitable for photon detection in both threshold and ring imaging Cerenkov detectors. We also found that a large longitudinal magnetic field, up t…
▽ More
We studied the single-photoelectron detection capabilities of a multianode photomultiplier tube H8500C-03 and its performance in high magnetic field. Our results show that the device can readily resolve signals at the single photoelectron level making it suitable for photon detection in both threshold and ring imaging Cerenkov detectors. We also found that a large longitudinal magnetic field, up to 300 Gauss, induces a change in the relative output of at most 55% for an edge pixel, and of at most 15% for a central pixel. The H8500C-03 signal loss in transverse magnetic fields it is significantly more pronounced than for the longitudinal case. Our studies of single photoelectron reduction in magnetic fields point to the field induced misfocusing of the photoelectron extracted from the photocathode as primary cause of signal loss. With appropriate shielding this PMT could function in high magnetic field environments.
△ Less
Submitted 26 June, 2013;
originally announced June 2013.
The lead-glass electromagnetic calorimeters for the magnetic spectrometers in Hall C at Jefferson Lab
Authors:
H. Mkrtchyan,
R. Carlini,
V. Tadevosyan,
J. Arrington,
A. Asaturyan,
M. E. Christy,
D. Dutta,
R. Ent,
H. C. Fenker,
D. Gaskell,
T. Horn,
M. K. Jones,
C. E. Keppel,
D. J. Mack,
S. P. Malace,
A. Mkrtchyan,
M. I. Niculescu,
J. Seely,
V. Tvaskis,
S. A. Wood,
S. Zhamkochyan
Abstract:
The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $σ/E \sim 6%/\sqrt E $, and pion/electron ($π/e$)…
▽ More
The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $σ/E \sim 6%/\sqrt E $, and pion/electron ($π/e$) separation of about 100:1 has been achieved in energy range 1 -- 5 GeV. Good agreement has been observed between the experimental and simulated energy resolutions, but simulations systematically exceed experimentally determined $π^-$ suppression factors by close to a factor of two. For the SHMS spectrometer presently under construction details on the design and accompanying GEANT4 simulation efforts are given. The anticipated performance of the new calorimeter is predicted over the full momentum range of the SHMS. Good electron/hadron separation is anticipated by combining the energy deposited in an initial (preshower) calorimeter layer with the total energy deposited in the calorimeter.
△ Less
Submitted 28 April, 2012;
originally announced April 2012.