Super Phantoms: advanced models for testing medical imaging technologies
Authors:
Srirang Manohar,
Ioannis Sechopoulos,
Mark A. Anastasio,
Lena Maier-Hein,
Rajiv,
Gupta
Abstract:
Phantoms are test objects used for initial testing and optimization of medical imaging techniques, but these rarely capture the complex properties of the tissue. Here we introduce super phantoms, that surpass standard phantoms being able to replicate complex anatomic and functional imaging properties of tissues and organs. These super phantoms can be computer models, inanimate physical objects, or…
▽ More
Phantoms are test objects used for initial testing and optimization of medical imaging techniques, but these rarely capture the complex properties of the tissue. Here we introduce super phantoms, that surpass standard phantoms being able to replicate complex anatomic and functional imaging properties of tissues and organs. These super phantoms can be computer models, inanimate physical objects, or ex-vivo organs. Testing on these super phantoms, will enable iterative improvements well before in-vivo studies, fostering innovation. We illustrate super phantom examples, address development challenges, and envision centralized facilities supporting multiple institutions in applying these models for medical advancements.
△ Less
Submitted 8 April, 2024; v1 submitted 24 August, 2023;
originally announced August 2023.
-
Semantic segmentation of multispectral photoacoustic images using deep learning
Authors:
Melanie Schellenberg,
Kris Dreher,
Niklas Holzwarth,
Fabian Isensee,
Annika Reinke,
Nicholas Schreck,
Alexander Seitel,
Minu D. Tizabi,
Lena Maier-Hein,
Janek Gröhl
Abstract:
Photoacoustic (PA) imaging has the potential to revolutionize functional medical imaging in healthcare due to the valuable information on tissue physiology contained in multispectral photoacoustic measurements. Clinical translation of the technology requires conversion of the high-dimensional acquired data into clinically relevant and interpretable information. In this work, we present a deep lear…
▽ More
Photoacoustic (PA) imaging has the potential to revolutionize functional medical imaging in healthcare due to the valuable information on tissue physiology contained in multispectral photoacoustic measurements. Clinical translation of the technology requires conversion of the high-dimensional acquired data into clinically relevant and interpretable information. In this work, we present a deep learning-based approach to semantic segmentation of multispectral photoacoustic images to facilitate image interpretability. Manually annotated photoacoustic {and ultrasound} imaging data are used as reference and enable the training of a deep learning-based segmentation algorithm in a supervised manner. Based on a validation study with experimentally acquired data from 16 healthy human volunteers, we show that automatic tissue segmentation can be used to create powerful analyses and visualizations of multispectral photoacoustic images. Due to the intuitive representation of high-dimensional information, such a preprocessing algorithm could be a valuable means to facilitate the clinical translation of photoacoustic imaging.
△ Less
Submitted 16 April, 2022; v1 submitted 20 May, 2021;
originally announced May 2021.
-
Photoacoustic image synthesis with generative adversarial networks
Authors:
Melanie Schellenberg,
Janek Gröhl,
Kris K. Dreher,
Jan-Hinrich Nölke,
Niklas Holzwarth,
Minu D. Tizabi,
Alexander Seitel,
Lena Maier-Hein
Abstract:
Photoacoustic tomography (PAT) has the potential to recover morphological and functional tissue properties with high spatial resolution. However, previous attempts to solve the optical inverse problem with supervised machine learning were hampered by the absence of labeled reference data. While this bottleneck has been tackled by simulating training data, the domain gap between real and simulated…
▽ More
Photoacoustic tomography (PAT) has the potential to recover morphological and functional tissue properties with high spatial resolution. However, previous attempts to solve the optical inverse problem with supervised machine learning were hampered by the absence of labeled reference data. While this bottleneck has been tackled by simulating training data, the domain gap between real and simulated images remains an unsolved challenge. We propose a novel approach to PAT image synthesis that involves subdividing the challenge of generating plausible simulations into two disjoint problems: (1) Probabilistic generation of realistic tissue morphology, and (2) pixel-wise assignment of corresponding optical and acoustic properties. The former is achieved with Generative Adversarial Networks (GANs) trained on semantically annotated medical imaging data. According to a validation study on a downstream task our approach yields more realistic synthetic images than the traditional model-based approach and could therefore become a fundamental step for deep learning-based quantitative PAT (qPAT).
△ Less
Submitted 25 October, 2022; v1 submitted 29 March, 2021;
originally announced March 2021.
-
Invertible Neural Networks for Uncertainty Quantification in Photoacoustic Imaging
Authors:
Jan-Hinrich Nölke,
Tim Adler,
Janek Gröhl,
Thomas Kirchner,
Lynton Ardizzone,
Carsten Rother,
Ullrich Köthe,
Lena Maier-Hein
Abstract:
Multispectral photoacoustic imaging (PAI) is an emerging imaging modality which enables the recovery of functional tissue parameters such as blood oxygenation. However, the underlying inverse problems are potentially ill-posed, meaning that radically different tissue properties may - in theory - yield comparable measurements. In this work, we present a new approach for handling this specific type…
▽ More
Multispectral photoacoustic imaging (PAI) is an emerging imaging modality which enables the recovery of functional tissue parameters such as blood oxygenation. However, the underlying inverse problems are potentially ill-posed, meaning that radically different tissue properties may - in theory - yield comparable measurements. In this work, we present a new approach for handling this specific type of uncertainty by leveraging the concept of conditional invertible neural networks (cINNs). Specifically, we propose going beyond commonly used point estimates for tissue oxygenation and converting single-pixel initial pressure spectra to the full posterior probability density. This way, the inherent ambiguity of a problem can be encoded with multiple modes in the output. Based on the presented architecture, we demonstrate two use cases which leverage this information to not only detect and quantify but also to compensate for uncertainties: (1) photoacoustic device design and (2) optimization of photoacoustic image acquisition. Our in silico studies demonstrate the potential of the proposed methodology to become an important building block for uncertainty-aware reconstruction of physiological parameters with PAI.
△ Less
Submitted 23 November, 2020; v1 submitted 10 November, 2020;
originally announced November 2020.
-
Tattoo tomography: Freehand 3D photoacoustic image reconstruction with an optical pattern
Authors:
Niklas Holzwarth,
Melanie Schellenberg,
Janek Gröhl,
Kris Dreher,
Jan-Hinrich Nölke,
Alexander Seitel,
Minu D. Tizabi,
Beat P. Müller-Stich,
Lena Maier-Hein
Abstract:
Purpose: Photoacoustic tomography (PAT) is a novel imaging technique that can spatially resolve both morphological and functional tissue properties, such as the vessel topology and tissue oxygenation. While this capacity makes PAT a promising modality for the diagnosis, treatment and follow-up of various diseases, a current drawback is the limited field-of-view (FoV) provided by the conventionally…
▽ More
Purpose: Photoacoustic tomography (PAT) is a novel imaging technique that can spatially resolve both morphological and functional tissue properties, such as the vessel topology and tissue oxygenation. While this capacity makes PAT a promising modality for the diagnosis, treatment and follow-up of various diseases, a current drawback is the limited field-of-view (FoV) provided by the conventionally applied 2D probes.
Methods: In this paper, we present a novel approach to 3D reconstruction of PAT data (Tattoo tomography) that does not require an external tracking system and can smoothly be integrated into clinical workflows. It is based on an optical pattern placed on the region of interest prior to image acquisition. This pattern is designed in a way that a tomographic image of it enables the recovery of the probe pose relative to the coordinate system of the pattern. This allows the transformation of a sequence of acquired PA images into one common global coordinate system and thus the consistent 3D reconstruction of PAT imaging data.
Results: An initial feasibility study conducted with experimental phantom data and in vivo forearm data indicates that the Tattoo approach is well-suited for 3D reconstruction of PAT data with high accuracy and precision.
Conclusion: In contrast to previous approaches to 3D ultrasound (US) or PAT reconstruction, the Tattoo approach neither requires complex external hardware nor training data acquired for a specific application. It could thus become a valuable tool for clinical freehand PAT.
△ Less
Submitted 11 November, 2020; v1 submitted 10 November, 2020;
originally announced November 2020.
-
Deep learning for biomedical photoacoustic imaging: A review
Authors:
Janek Gröhl,
Melanie Schellenberg,
Kris Dreher,
Lena Maier-Hein
Abstract:
Photoacoustic imaging (PAI) is a promising emerging imaging modality that enables spatially resolved imaging of optical tissue properties up to several centimeters deep in tissue, creating the potential for numerous exciting clinical applications. However, extraction of relevant tissue parameters from the raw data requires the solving of inverse image reconstruction problems, which have proven ext…
▽ More
Photoacoustic imaging (PAI) is a promising emerging imaging modality that enables spatially resolved imaging of optical tissue properties up to several centimeters deep in tissue, creating the potential for numerous exciting clinical applications. However, extraction of relevant tissue parameters from the raw data requires the solving of inverse image reconstruction problems, which have proven extremely difficult to solve. The application of deep learning methods has recently exploded in popularity, leading to impressive successes in the context of medical imaging and also finding first use in the field of PAI. Deep learning methods possess unique advantages that can facilitate the clinical translation of PAI, such as extremely fast computation times and the fact that they can be adapted to any given problem. In this review, we examine the current state of the art regarding deep learning in PAI and identify potential directions of research that will help to reach the goal of clinical applicability
△ Less
Submitted 5 November, 2020;
originally announced November 2020.
-
Out of distribution detection for intra-operative functional imaging
Authors:
Tim J. Adler,
Leonardo Ayala,
Lynton Ardizzone,
Hannes G. Kenngott,
Anant Vemuri,
Beat P. Müller-Stich,
Carsten Rother,
Ullrich Köthe,
Lena Maier-Hein
Abstract:
Multispectral optical imaging is becoming a key tool in the operating room. Recent research has shown that machine learning algorithms can be used to convert pixel-wise reflectance measurements to tissue parameters, such as oxygenation. However, the accuracy of these algorithms can only be guaranteed if the spectra acquired during surgery match the ones seen during training. It is therefore of gre…
▽ More
Multispectral optical imaging is becoming a key tool in the operating room. Recent research has shown that machine learning algorithms can be used to convert pixel-wise reflectance measurements to tissue parameters, such as oxygenation. However, the accuracy of these algorithms can only be guaranteed if the spectra acquired during surgery match the ones seen during training. It is therefore of great interest to detect so-called out of distribution (OoD) spectra to prevent the algorithm from presenting spurious results. In this paper we present an information theory based approach to OoD detection based on the widely applicable information criterion (WAIC). Our work builds upon recent methodology related to invertible neural networks (INN). Specifically, we make use of an ensemble of INNs as we need their tractable Jacobians in order to compute the WAIC. Comprehensive experiments with in silico, and in vivo multispectral imaging data indicate that our approach is well-suited for OoD detection. Our method could thus be an important step towards reliable functional imaging in the operating room.
△ Less
Submitted 5 November, 2019;
originally announced November 2019.
-
Band selection for oxygenation estimation with multispectral/hyperspectral imaging
Authors:
Leonardo A. Ayala,
Fabian Isensee,
Sebastian J. Wirkert,
Anant S. Vemuri,
Klaus H. Maier-Hein,
Baowei Fei,
Lena Maier-Hein
Abstract:
Multispectral imaging provides valuable information on tissue composition such as hemoglobin oxygen saturation. However, the real-time application of this technique in interventional medicine can be challenging due to the long acquisition times needed for large amounts of hyperspectral data with hundreds of bands. While this challenge can partially be addressed by choosing a discriminative subset…
▽ More
Multispectral imaging provides valuable information on tissue composition such as hemoglobin oxygen saturation. However, the real-time application of this technique in interventional medicine can be challenging due to the long acquisition times needed for large amounts of hyperspectral data with hundreds of bands. While this challenge can partially be addressed by choosing a discriminative subset of bands, the band selection methods proposed to date are mainly restricted by the availability of often hard to obtain reference measurements. We address this bottleneck with a new approach to band selection that leverages highly accurate Monte Carlo (MC) simulations. We hypothesize that a so chosen small subset of bands can reproduce or even improve upon the results of a quasi continuous spectral measurement. We further investigate whether novel domain adaptation techniques can address the inevitable domain shift stemming from the use of simulations. Initial results based on in silico and in vivo experiments suggest that 10-20 bands are sufficient to closely reproduce results from spectral measurements with 101 bands in the 500-700 nm range. The investigated domain adaptation technique, which only requires unlabeled in vivo measurements, yielded better results than the pure in silico band selection method. Overall, our method could guide development of fast multispectral imaging systems suited for interventional use without relying on complex hardware setups or manually labeled data
△ Less
Submitted 20 August, 2021; v1 submitted 27 May, 2019;
originally announced May 2019.
-
Photoacoustic monitoring of blood oxygenation during neurosurgical interventions
Authors:
Thomas Kirchner,
Janek Gröhl,
Niklas Holzwarth,
Mildred A. Herrera,
Tim Adler,
Adrián Hernández-Aguilera,
Edgar Santos,
Lena Maier-Hein
Abstract:
Multispectral photoacoustic (PA) imaging is a prime modality to monitor hemodynamics and changes in blood oxygenation (sO2). Although sO2 changes can be an indicator of brain activity both in normal and in pathological conditions, PA imaging of the brain has mainly focused on small animal models with lissencephalic brains. Therefore, the purpose of this work was to investigate the usefulness of mu…
▽ More
Multispectral photoacoustic (PA) imaging is a prime modality to monitor hemodynamics and changes in blood oxygenation (sO2). Although sO2 changes can be an indicator of brain activity both in normal and in pathological conditions, PA imaging of the brain has mainly focused on small animal models with lissencephalic brains. Therefore, the purpose of this work was to investigate the usefulness of multispectral PA imaging in assessing sO2 in a gyrencephalic brain. To this end, we continuously imaged a porcine brain as part of an open neurosurgical intervention with a handheld PA and ultrasonic (US) imaging system in vivo. Throughout the experiment, we varied respiratory oxygen and continuously measured arterial blood gases. The arterial blood oxygenation (SaO2) values derived by the blood gas analyzer were used as a reference to compare the performance of linear spectral unmixing algorithms in this scenario. According to our experiment, PA imaging can be used to monitor sO2 in the porcine cerebral cortex. While linear spectral unmixing algorithms are well-suited for detecting changes in oxygenation, there are limits with respect to the accurate quantification of sO2, especially in depth. Overall, we conclude that multispectral PA imaging can potentially be a valuable tool for change detection of sO2 in the cerebral cortex of a gyrencephalic brain. The spectral unmixing algorithms investigated in this work will be made publicly available as part of the open-source software platform Medical Imaging Interaction Toolkit (MITK).
△ Less
Submitted 26 April, 2019;
originally announced April 2019.
-
Hyperspectral Camera Selection for Interventional Health-care
Authors:
Anant S. Vemuri,
Sebastian Wirkert,
Lena Maier-Hein
Abstract:
Hyperspectral imaging (HSI) is an emerging modality in health-care applications for disease diagnosis, tissue assessment and image-guided surgery. Tissue reflectances captured by a HSI camera encode physiological properties including oxygenation and blood volume fraction. Optimal camera properties such as filter responses depend crucially on the application, and choosing a suitable HSI camera for…
▽ More
Hyperspectral imaging (HSI) is an emerging modality in health-care applications for disease diagnosis, tissue assessment and image-guided surgery. Tissue reflectances captured by a HSI camera encode physiological properties including oxygenation and blood volume fraction. Optimal camera properties such as filter responses depend crucially on the application, and choosing a suitable HSI camera for a research project and/or a clinical problem is not straightforward. We propose a generic framework for quantitative and application-specific performance assessment of HSI cameras and optical subsystem without the need for any physical setup. Based on user input about the camera characteristics and properties of the target domain, our framework quantifies the performance of the given camera configuration using large amounts of simulated data and a user-defined metric. The application of the framework to commercial camera selection and band selection in the context of oxygenation monitoring in interventional health-care demonstrates its integration into the design work-flow of an engineer. The advantage of being able to test the desired configuration without the need for purchasing expensive components may save system engineers valuable resources.
△ Less
Submitted 4 April, 2019;
originally announced April 2019.
-
Navigated interventions in the head and neck area: standardized assessment of a new handy field generator
Authors:
Benjamin J. Mittmann,
Alexander Seitel,
Lena Maier-Hein,
Alfred M. Franz
Abstract:
Electromagnetic (EM) tracking enables localization of surgical instruments within the magnetic field emitted by an EM field generator (FG). Usually, the larger a FG is, the larger its tracking volume is. However, the company NDI (Northern Digital Inc., Waterloo, ON, Canada) recently introduced the Planar 10-11 FG, which combines a compact construction (97mm x 112mm x 31mm) with a relatively large,…
▽ More
Electromagnetic (EM) tracking enables localization of surgical instruments within the magnetic field emitted by an EM field generator (FG). Usually, the larger a FG is, the larger its tracking volume is. However, the company NDI (Northern Digital Inc., Waterloo, ON, Canada) recently introduced the Planar 10-11 FG, which combines a compact construction (97mm x 112mm x 31mm) with a relatively large, cylindrical tracking volume (diameter: 340mm, height: 340mm). Using the standardized assessment protocol of Hummel et al., the FG was tested with regard to its tracking accuracy and to its robustness with respect to external sources of disturbance. The mean positional error (5cm distance metric according to Hummel protocol) was 0.59mm, with a mean jitter of 0.26mm in the standard setup. The mean orientational error was found to be 0.10°. The highest positional error (4.82mm) due to metallic sources of disturbance was caused by the steel SST 303. In contrast, steel SST 416 caused the lowest positional error (0.10mm). Overall, the Planar 10-11 FG tends to achieve better tracking accuracy results compared to other NDI FGs. Due to its compact construction and portability, the FG could contribute to increased clinical use of EM tracking systems.
△ Less
Submitted 24 March, 2019;
originally announced March 2019.
-
Open-source Tracked Ultrasound with Anser EMT
Authors:
Alfred Michael Franz,
Herman Alexander Jaeger,
Alexander Seitel,
Padraig Cantillon-Murphy,
Lena Maier-Hein
Abstract:
Image-guided Interventions (IGT) have shown a huge potential to improve medical procedures or even allow for new treatment options. Most ultrasound(US)-based IGT systems use electromagnetic (EM) tracking for localizing US probes and instruments. However, EM tracking is not always reliable in clinical settings because the EM field can be disturbed by medical equipment. So far, most researchers used…
▽ More
Image-guided Interventions (IGT) have shown a huge potential to improve medical procedures or even allow for new treatment options. Most ultrasound(US)-based IGT systems use electromagnetic (EM) tracking for localizing US probes and instruments. However, EM tracking is not always reliable in clinical settings because the EM field can be disturbed by medical equipment. So far, most researchers used and studied commercial EM trackers with their IGT systems which in turn limited the possibilities to customize the trackers in order minimize distortions and make the systems robust for clinical use. In light of current good scientific practice initiatives that increasingly request research to publish the source code corresponding to a paper, the aim of this work was to test the feasibility of using the open-source EM tracker Anser EMT for localizing US probes in a clinical US suite for the first time. The standardized protocol of Hummel et al. yielded a jitter of 0.1$\pm$0.1 mm and a position error of 1.1$\pm$0.7 mm, which is comparable to 0.1 mm and 1.0 mm of a commercial NDI Aurora system. The rotation error of Anser EMT was 0.15$\pm$0.16°, which is lower than at least 0.4° for the commercial tracker. We consider tracked US as feasible with Anser EMT if an accuracy of 1-2 mm is sufficient for a specific application.
△ Less
Submitted 15 March, 2019;
originally announced March 2019.
-
Uncertainty-aware performance assessment of optical imaging modalities with invertible neural networks
Authors:
Tim J. Adler,
Lynton Ardizzone,
Anant Vemuri,
Leonardo Ayala,
Janek Gröhl,
Thomas Kirchner,
Sebastian Wirkert,
Jakob Kruse,
Carsten Rother,
Ullrich Köthe,
Lena Maier-Hein
Abstract:
Purpose: Optical imaging is evolving as a key technique for advanced sensing in the operating room. Recent research has shown that machine learning algorithms can be used to address the inverse problem of converting pixel-wise multispectral reflectance measurements to underlying tissue parameters, such as oxygenation. Assessment of the specific hardware used in conjunction with such algorithms, ho…
▽ More
Purpose: Optical imaging is evolving as a key technique for advanced sensing in the operating room. Recent research has shown that machine learning algorithms can be used to address the inverse problem of converting pixel-wise multispectral reflectance measurements to underlying tissue parameters, such as oxygenation. Assessment of the specific hardware used in conjunction with such algorithms, however, has not properly addressed the possibility that the problem may be ill-posed.
Methods: We present a novel approach to the assessment of optical imaging modalities, which is sensitive to the different types of uncertainties that may occur when inferring tissue parameters. Based on the concept of invertible neural networks, our framework goes beyond point estimates and maps each multispectral measurement to a full posterior probability distribution which is capable of representing ambiguity in the solution via multiple modes. Performance metrics for a hardware setup can then be computed from the characteristics of the posteriors.
Results: Application of the assessment framework to the specific use case of camera selection for physiological parameter estimation yields the following insights: (1) Estimation of tissue oxygenation from multispectral images is a well-posed problem, while (2) blood volume fraction may not be recovered without ambiguity. (3) In general, ambiguity may be reduced by increasing the number of spectral bands in the camera.
Conclusion: Our method could help to optimize optical camera design in an application-specific manner.
△ Less
Submitted 8 March, 2019;
originally announced March 2019.
-
Estimation of blood oxygenation with learned spectral decoloring for quantitative photoacoustic imaging (LSD-qPAI)
Authors:
Janek Gröhl,
Thomas Kirchner,
Tim Adler,
Lena Maier-Hein
Abstract:
One of the main applications of photoacoustic (PA) imaging is the recovery of functional tissue properties, such as blood oxygenation (sO2). This is typically achieved by linear spectral unmixing of relevant chromophores from multispectral photoacoustic images. Despite the progress that has been made towards quantitative PA imaging (qPAI), most sO2 estimation methods yield poor results in realisti…
▽ More
One of the main applications of photoacoustic (PA) imaging is the recovery of functional tissue properties, such as blood oxygenation (sO2). This is typically achieved by linear spectral unmixing of relevant chromophores from multispectral photoacoustic images. Despite the progress that has been made towards quantitative PA imaging (qPAI), most sO2 estimation methods yield poor results in realistic settings. In this work, we tackle the challenge by employing learned spectral decoloring for quantitative photoacoustic imaging (LSD-qPAI) to obtain quantitative estimates for blood oxygenation. LSD-qPAI computes sO2 directly from pixel-wise initial pressure spectra Sp0, which are vectors comprised of the initial pressure at the same spatial location over all recorded wavelengths. Initial results suggest that LSD-qPAI is able to obtain accurate sO2 estimates directly from multispectral photoacoustic measurements in silico and plausible estimates in vivo.
△ Less
Submitted 15 February, 2019;
originally announced February 2019.
-
An open-source software platform for translational photoacoustic research and its application to motion-corrected blood oxygenation estimation
Authors:
Thomas Kirchner,
Janek Gröhl,
Franz Sattler,
Moritz S. Bischoff,
Angelika Laha,
Marco Nolden,
Lena Maier-Hein
Abstract:
Photoacoustic (PA) imaging systems based on clinical linear ultrasound arrays have become increasingly popular in translational PA research. Such systems can be more easily integrated in a clinical workflow due to the simultaneous access to ultrasonic imaging and their familiarity of use to clinicians. In contrast to more complex setups, hand held linear probes can be applied to a large variety of…
▽ More
Photoacoustic (PA) imaging systems based on clinical linear ultrasound arrays have become increasingly popular in translational PA research. Such systems can be more easily integrated in a clinical workflow due to the simultaneous access to ultrasonic imaging and their familiarity of use to clinicians. In contrast to more complex setups, hand held linear probes can be applied to a large variety of clinical use cases. However, most translational work with such scanners is based on proprietary development and as such not accessible to the community. In this contribution, we present a custom-built, hybrid, multispectral, real-time photoacoustic and ultrasonic imaging system with a linear array probe that is controlled by software developed within the Medical Imaging Interaction Toolkit (MITK) a highly customizable and extendable open-source software platform. Our software offers direct control of both the laser and the ultrasonic system and may serve as a starting point for various translational research projects and developments. To demonstrate the applicability of the platform, we used it to implement a new method for blood oxygenation estimation in the presence of non-rigid inter-frame motion caused by pulsing arteries. Initial results from experiments with healthy human volunteers demonstrate the suitability of the method with the sample clinical application of imaging the common carotid artery as well as peripheral extremity vessels.
△ Less
Submitted 28 January, 2019;
originally announced January 2019.
-
Photoacoustics can image spreading depolarization deep in gyrencephalic brain
Authors:
Thomas Kirchner,
Janek Gröhl,
Mildred Herrera,
Tim Adler,
Adrián Hernández-Aguilera,
Edgar Santos,
Lena Maier-Hein
Abstract:
Spreading depolarization (SD) is a self-propagating wave of near-complete neuronal depolarization that is abundant in a wide range of neurological conditions, including stroke. SD was only recently documented in humans and is now considered a therapeutic target for brain injury, but the mechanisms related to SD in complex brains are not well understood. While there are numerous approaches to inter…
▽ More
Spreading depolarization (SD) is a self-propagating wave of near-complete neuronal depolarization that is abundant in a wide range of neurological conditions, including stroke. SD was only recently documented in humans and is now considered a therapeutic target for brain injury, but the mechanisms related to SD in complex brains are not well understood. While there are numerous approaches to interventional imaging of SD on the exposed brain surface, measuring SD deep in brain is so far only possible with low spatiotemporal resolution and poor contrast. Here, we show that photoacoustic imaging enables the study of SD and its hemodynamics deep in the gyrencephalic brain with high spatiotemporal resolution. As rapid neuronal depolarization causes tissue hypoxia, we achieve this by continuously estimating blood oxygenation with an intraoperative hybrid photoacoustic and ultrasonic (PAUS) imaging system. Due to its high resolution, promising imaging depth and high contrast, this novel approach to SD imaging can yield new insights into SD and thereby lead to advances in stroke, and brain injury research.
△ Less
Submitted 14 January, 2019; v1 submitted 9 January, 2019;
originally announced January 2019.
-
Context encoding enables machine learning-based quantitative photoacoustics
Authors:
Thomas Kirchner,
Janek Gröhl,
Lena Maier-Hein
Abstract:
Real-time monitoring of functional tissue parameters, such as local blood oxygenation, based on optical imaging could provide groundbreaking advances in the diagnosis and interventional therapy of various diseases. While photoacoustic (PA) imaging is a novel modality with great potential to measure optical absorption deep inside tissue, quantification of the measurements remains a major challenge.…
▽ More
Real-time monitoring of functional tissue parameters, such as local blood oxygenation, based on optical imaging could provide groundbreaking advances in the diagnosis and interventional therapy of various diseases. While photoacoustic (PA) imaging is a novel modality with great potential to measure optical absorption deep inside tissue, quantification of the measurements remains a major challenge. In this paper, we introduce the first machine learning based approach to quantitative PA imaging (qPAI), which relies on learning the fluence in a voxel to deduce the corresponding optical absorption. The method encodes relevant information of the measured signal and the characteristics of the imaging system in voxel-based feature vectors, which allow the generation of thousands of training samples from a single simulated PA image. Comprehensive in silico experiments suggest that context encoding (CE)-qPAI enables highly accurate and robust quantification of the local fluence and thereby the optical absorption from PA images.
△ Less
Submitted 29 January, 2018; v1 submitted 12 June, 2017;
originally announced June 2017.