-
LEGEND-1000 Preconceptual Design Report
Authors:
LEGEND Collaboration,
N. Abgrall,
I. Abt,
M. Agostini,
A. Alexander,
C. Andreoiu,
G. R. Araujo,
F. T. Avignone III,
W. Bae,
A. Bakalyarov,
M. Balata,
M. Bantel,
I. Barabanov,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
L. Baudis,
C. Bauer,
E. Bernieri,
L. Bezrukov,
K. H. Bhimani,
V. Biancacci,
E. Blalock,
A. Bolozdynya
, et al. (239 additional authors not shown)
Abstract:
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory…
▽ More
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory. By combining the lowest background levels with the best energy resolution in the field, LEGEND-1000 will perform a quasi-background-free search and can make an unambiguous discovery of neutrinoless double-beta decay with just a handful of counts at the decay $Q$ value. The experiment is designed to probe this decay with a 99.7%-CL discovery sensitivity in the $^{76}$Ge half-life of $1.3\times10^{28}$ years, corresponding to an effective Majorana mass upper limit in the range of 9-21 meV, to cover the inverted-ordering neutrino mass scale with 10 yr of live time.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Measurement of the distribution of $^{207}$Bi depositions on calibration sources for SuperNEMO
Authors:
R. Arnold,
C. Augier,
A. S. Barabash,
A. Basharina-Freshville,
E. Birdsall,
S. Blondel,
M. Bongrand,
D. Boursette,
R. Breier,
V. Brudanin,
J. Busto,
S. Calvez,
C. Cerna,
J. P. Cesar,
M. Ceschia,
A. Chapon,
E. Chauveau,
A. Chopra,
L. Dawson,
S. De Capua,
D. Duchesneau,
D. Durand,
G. Eurin,
J. J. Evans,
D. Filosofov
, et al. (75 additional authors not shown)
Abstract:
The SuperNEMO experiment will search for neutrinoless double-beta decay ($0νββ$), and study the Standard-Model double-beta decay process ($2νββ$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($ββ$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calib…
▽ More
The SuperNEMO experiment will search for neutrinoless double-beta decay ($0νββ$), and study the Standard-Model double-beta decay process ($2νββ$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($ββ$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of $^{207}$Bi within a frame assembly.
The quality of these sources, which depends upon the entire $^{207}$Bi droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of $^{207}$Bi droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.
△ Less
Submitted 20 May, 2021; v1 submitted 26 March, 2021;
originally announced March 2021.
-
Search for the double-beta decay of 82Se to the excited states of 82Kr with NEMO-3
Authors:
The NEMO-3 collaboration R. Arnold,
C. Augier,
A. S. Barabash,
A. Basharina-Freshville,
S. Blondel,
S. Blot,
M. Bongrand,
D. Boursette,
R. Breier,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
C. Cerna,
J. P. Cesar,
A. Chapon,
E. Chauveau,
A. Chopra,
L. Dawson,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin,
J. J. Evans
, et al. (82 additional authors not shown)
Abstract:
The double-beta decay of 82Se to the 0+1 excited state of 82Kr has been studied with the NEMO-3 detector using 0.93 kg of enriched 82Se measured for 4.75 y, corresponding to an exposure of 4.42 kg y. A dedicated analysis to reconstruct the gamma-rays has been performed to search for events in the 2e2g channel. No evidence of a 2nbb decay to the 0+1 state has been observed and a limit of T2n 1/2(82…
▽ More
The double-beta decay of 82Se to the 0+1 excited state of 82Kr has been studied with the NEMO-3 detector using 0.93 kg of enriched 82Se measured for 4.75 y, corresponding to an exposure of 4.42 kg y. A dedicated analysis to reconstruct the gamma-rays has been performed to search for events in the 2e2g channel. No evidence of a 2nbb decay to the 0+1 state has been observed and a limit of T2n 1/2(82Se; 0+gs -> 0+1) > 1.3 1021 y at 90% CL has been set. Concerning the 0nbb decay to the 0+1 state, a limit for this decay has been obtained with T0n 1/2(82Se; 0+g s -> 0+1) > 2.3 1022 y at 90% CL, independently from the 2nbb decay process. These results are obtained for the first time with a tracko-calo detector, reconstructing every particle in the final state.
△ Less
Submitted 17 January, 2020;
originally announced January 2020.
-
Calorimeter development for the SuperNEMO double beta decay experiment
Authors:
A. S. Barabash,
A. Basharina-Freshville,
S. Blot,
M. Bongrand,
Ch. Bourgeois,
D. Breton,
V. Brudanin,
H. Burešovà,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
C. Cerna,
J. P. Cesar,
E. Chauveau,
A. Chopra,
G. Claverie,
S. De Capua,
F. Delalee,
D. Duchesneau,
V. Egorov,
G. Eurin,
J. J. Evans,
L. Fajt,
D. Filosofov
, et al. (73 additional authors not shown)
Abstract:
SuperNEMO is a double-$β$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$β$ decay isotope, reaching a sensitivity to the neutrinoless double-$β$ decay ($0νββ$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main…
▽ More
SuperNEMO is a double-$β$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$β$ decay isotope, reaching a sensitivity to the neutrinoless double-$β$ decay ($0νββ$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main goals and challenges of the SuperNEMO detector development programme has been to reach a calorimeter energy resolution, $Δ$E/E, around 3%/$sqrt(E)$(MeV) $σ$, or 7%/$sqrt(E)$(MeV) FWHM (full width at half maximum), using a calorimeter composed of large volume plastic scintillator blocks coupled to photomultiplier tubes. We describe the R\&D programme and the final design of the SuperNEMO calorimeter that has met this challenging goal.
△ Less
Submitted 21 July, 2017;
originally announced July 2017.
-
The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials
Authors:
A. S. Barabash,
A. Basharina-Freshville,
E. Birdsall,
S. Blondel,
S. Blot,
M. Bongrand,
D. Boursette,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
S. Cebrián,
C. Cerna,
J. P Cesar,
E. Chauveau,
A. Chopra,
T. Dafní,
S. De Capua,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin,
J. J. Evans,
L. Fajt
, et al. (71 additional authors not shown)
Abstract:
The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been…
▽ More
The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been developed to measure radiopurity of the selenium double $β$-decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in $^{208}$Tl and $^{214}$Bi, are presented, and validation of the BiPo-3 measurement with a calibrated aluminium foil is discussed. Results of the $^{208}$Tl and $^{214}$Bi activity measurements of the first enriched $^{82}$Se foils of the double $β$-decay SuperNEMO experiment are reported. The sensitivity of the BiPo-3 detector for the measurement of the SuperNEMO $^{82}$Se foils is $\mathcal{A}$($^{208}$Tl) $<2$ $μ$Bq/kg (90\% C.L.) and $\mathcal{A}$($^{214}$Bi) $<140$ $μ$Bq/kg (90\% C.L.) after 6 months of measurement.
△ Less
Submitted 7 June, 2017; v1 submitted 23 February, 2017;
originally announced February 2017.
-
Measurement of the $2νββ$ Decay Half-Life and Search for the $0νββ$ Decay of $^{116}$Cd with the NEMO-3 Detector
Authors:
NEMO-3 Collaboration,
:,
R. Arnold,
C. Augier,
J. D. Baker,
A. S. Barabash,
A. Basharina-Freshville,
S. Blondel,
S. Blot,
M. Bongrand,
D. Boursette,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
C. Cerna,
J. P. Cesar,
A. Chapon,
E. Chauveau,
A. Chopra,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin
, et al. (73 additional authors not shown)
Abstract:
The NEMO-3 experiment measured the half-life of the $2νββ$ decay and searched for the $0νββ$ decay of $^{116}$Cd. Using $410$ g of $^{116}$Cd installed in the detector with an exposure of $5.26$ y, ($4968\pm74$) events corresponding to the $2νββ$ decay of $^{116}$Cd to the ground state of $^{116}$Sn have been observed with a signal to background ratio of about $12$. The half-life of the $2νββ$ dec…
▽ More
The NEMO-3 experiment measured the half-life of the $2νββ$ decay and searched for the $0νββ$ decay of $^{116}$Cd. Using $410$ g of $^{116}$Cd installed in the detector with an exposure of $5.26$ y, ($4968\pm74$) events corresponding to the $2νββ$ decay of $^{116}$Cd to the ground state of $^{116}$Sn have been observed with a signal to background ratio of about $12$. The half-life of the $2νββ$ decay has been measured to be $ T_{1/2}^{2ν}=[2.74\pm0.04\mbox{(stat.)}\pm0.18\mbox{(syst.)}]\times10^{19}$ y. No events have been observed above the expected background while searching for $0νββ$ decay. The corresponding limit on the half-life is determined to be $T_{1/2}^{0ν} \ge 1.0 \times 10^{23}$ y at the $90$ % C.L. which corresponds to an upper limit on the effective Majorana neutrino mass of $\langle m_ν \rangle \le 1.4-2.5$ eV depending on the nuclear matrix elements considered. Limits on other mechanisms generating $0νββ$ decay such as the exchange of R-parity violating supersymmetric particles, right-handed currents and majoron emission are also obtained.
△ Less
Submitted 23 December, 2016; v1 submitted 11 October, 2016;
originally announced October 2016.