Property investigation for different wedge-shaped CsI(Tl)s
Authors:
G. Li,
J. L. Lou,
Y. L. Ye,
H. Hua,
H. Wang,
J. X. Han,
W. Liu,
S. W. Bai,
Z. W. Tan,
K. Ma,
J. H. Chen,
L. S. Yang,
S. J. Wang,
Z. Y. Hu,
H. Z. Yu,
H. Y. Zhu,
B. L. Xia,
Y. Jiang,
Y. Liu,
X. F. Yang,
Q. T. Li,
J. Y. Xu,
J. S. Wang,
Y. Y. Yang,
J. B. Ma
, et al. (10 additional authors not shown)
Abstract:
Two types of wedge-shaped CsI(Tl)s were designed to be placed behind the annular double-sided silicon detectors (ADSSDs) to identify the light charged particles with the $ΔE-E$ method. The properties of CsI(Tl)s with different shapes and sizes, such as energy resolution, light output non-uniformity and particle identification capability, were compared by using a $α$-source and a radioactive beam o…
▽ More
Two types of wedge-shaped CsI(Tl)s were designed to be placed behind the annular double-sided silicon detectors (ADSSDs) to identify the light charged particles with the $ΔE-E$ method. The properties of CsI(Tl)s with different shapes and sizes, such as energy resolution, light output non-uniformity and particle identification capability, were compared by using a $α$-source and a radioactive beam of $^{15}$C. The big-size CsI(Tl) was finally adopted to form the $ΔE-E$ telescope due to better properties. The property differences of these two types of CsI(Tl)s can be interpreted based on the Geant4 simulation results.
△ Less
Submitted 2 March, 2021;
originally announced March 2021.
The performance of a double sided silicon strip detector as a transmission detector for heavy ions
Authors:
J L Han,
J B Ma,
X G Cao,
Q Wang,
J S Wang,
Y Y Yang,
P Ma,
M R Huang,
S L **,
X J Rong,
Z Bai,
F Fu,
Q Hu,
R F Chen,
S W Xu,
J B Chen,
L **,
Y Li,
M H Zhao,
H S Xu
Abstract:
The performance of a double sided silicon strip detector (DSSSD), used for position and energy detection of heavy ions, is reported. The analysis shows that the incomplete charge collection (ICC) and charge sharing (CS) effects of the DSSSD give rise to a loss of energy resolution, however the position information is recorded without ambiguity. Representations of ICC/CS events in the energy spectr…
▽ More
The performance of a double sided silicon strip detector (DSSSD), used for position and energy detection of heavy ions, is reported. The analysis shows that the incomplete charge collection (ICC) and charge sharing (CS) effects of the DSSSD give rise to a loss of energy resolution, however the position information is recorded without ambiguity. Representations of ICC/CS events in the energy spectra are shown and their origins are confirmed by correlation analysis of the spectra from both junction side and ohmic side of the DSSSD.
△ Less
Submitted 15 July, 2013;
originally announced July 2013.