Skip to main content

Showing 1–5 of 5 results for author: Müllner, P

Searching in archive physics. Search in all archives.
.
  1. arXiv:2011.14780  [pdf, other

    physics.app-ph physics.optics

    Multi-channel swept source optical coherence tomography concept based on photonic integrated circuits

    Authors: Stefan Nevlacsil, Paul Muellner, Alejandro Maese-Novo, Moritz Eggeling, Florian Vogelbacher, Martin Sagmeister, Jochen Kraft, Elisabet Rank, Wolfgang Drexler, Rainer Hainberger

    Abstract: In this paper, we present a novel concept for a multi-channel swept source optical coherence tomography (OCT) system based on photonic integrated circuits (PICs). At the core of this concept is a low-loss polarization dependent path routing approach allowing for lower excess loss compared to previously shown PIC-based OCT systems, facilitating a parallelization of measurement units. As a proof of… ▽ More

    Submitted 15 October, 2020; originally announced November 2020.

    Comments: 15 pages, 6 figures, 3 tables

    Journal ref: Opt. Express 28, 32468-32482 (2020)

  2. arXiv:2002.11399  [pdf, other

    physics.optics physics.app-ph

    Broadband low loss and ultra-low crosstalk waveguide crossings based on multimode interferometer for 840 nm operation

    Authors: Stefan Nevlacsil, Paul Muellner, Martin Sagmeister, Jochen Kraft, Rainer Hainberger

    Abstract: Broadband low loss and ultra-low crosstalk waveguide crossings are a crucial component for photonic integrated circuits to allow a higher integration density of functional components and an increased flexibility in the layout. We report the design of optimized silicon nitride waveguide crossings based on multimode interferometer structures for intersecting light paths of TE/TE-like, TM/TM-like and… ▽ More

    Submitted 26 February, 2020; originally announced February 2020.

    Comments: 12 pages, 5 figures \c{opyright} 2020 Optical Society of America. Users may use, reuse, and build upon the article, or use the article for text or data mining, so long as such uses are for non-commercial purposes and appropriate attribution is maintained. All other rights are reserved

    Journal ref: OSA Continuum 3, 334-344 (2020)

  3. arXiv:1903.12585  [pdf, other

    physics.optics physics.app-ph

    Broadband SiN asymmetric directional coupler for 840 nm operation

    Authors: Stefan Nevlacsil, Moritz Eggeling, Paul Muellner, Guenther Koppitsch, Martin Sagmeister, Jochen Kraft, Rainer Hainberger

    Abstract: Silicon nitride based photonic integrated circuits offer a wavelength operation window in the near infrared down to visible light, which makes them attractive for life science applications. However, they exhibit significantly different behavior in comparison with better-established silicon on insulator counterparts due to the lower index contrast. Among the most important building blocks in photon… ▽ More

    Submitted 29 March, 2019; originally announced March 2019.

    Comments: 8 pages, 6 figures \c{opyright} 2018 Optical Society of America. Users may use, reuse, and build upon the article, or use the article for text or data mining, so long as such uses are for non-commercial purposes and appropriate attribution is maintained. All other rights are reserved

    Journal ref: OSA Continuum 1, 1324-1331 (2018)

  4. arXiv:1702.05093  [pdf, other

    physics.ins-det hep-ex

    A Large Ungated TPC with GEM Amplification

    Authors: M. Berger, M. Ball, L. Fabbietti, B. Ketzer, R. Arora, R. Beck, F. Böhmer, J. -C. Chen, F. Cusanno, S. Dørheim, J. Hehner, N. Herrmann, C. Höppner, D. Kaiser, M. Kis, V. Kleipa, I. Konorov, J. Kunkel, N. Kurz, Y. Leifels, P. Müllner, R. Münzer, S. Neubert, J. Rauch, C. J. Schmidt , et al. (6 additional authors not shown)

    Abstract: A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons… ▽ More

    Submitted 16 February, 2017; originally announced February 2017.

    Comments: 73 pages, 55 figures

  5. arXiv:1207.0013  [pdf

    physics.ins-det hep-ex nucl-ex

    Technical Design Study for the PANDA Time Projection Chamber

    Authors: M. Ball, F. V. Böhmer, S. Dørheim, C. Höppner, B. Ketzer, I. Konorov, S. Neubert, S. Paul, J. Rauch, S. Uhl, M. Vandenbroucke, M. Berger, J. -C. Berger-Chen, F. Cusanno, L. Fabbietti, R. Münzer, R. Arora, J. Frühauf, M. Kiš, Y. Leifels, V. Kleipa, J. Hehner, J. Kunkel, N. Kurz, K. Peters , et al. (16 additional authors not shown)

    Abstract: This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.

    Submitted 29 June, 2012; originally announced July 2012.

    Comments: Editors: B. Ketzer, L. Fabbietti (TU München) 84 pages, 122 figures