-
Multi-channel swept source optical coherence tomography concept based on photonic integrated circuits
Authors:
Stefan Nevlacsil,
Paul Muellner,
Alejandro Maese-Novo,
Moritz Eggeling,
Florian Vogelbacher,
Martin Sagmeister,
Jochen Kraft,
Elisabet Rank,
Wolfgang Drexler,
Rainer Hainberger
Abstract:
In this paper, we present a novel concept for a multi-channel swept source optical coherence tomography (OCT) system based on photonic integrated circuits (PICs). At the core of this concept is a low-loss polarization dependent path routing approach allowing for lower excess loss compared to previously shown PIC-based OCT systems, facilitating a parallelization of measurement units. As a proof of…
▽ More
In this paper, we present a novel concept for a multi-channel swept source optical coherence tomography (OCT) system based on photonic integrated circuits (PICs). At the core of this concept is a low-loss polarization dependent path routing approach allowing for lower excess loss compared to previously shown PIC-based OCT systems, facilitating a parallelization of measurement units. As a proof of concept for the low-loss path routing, a silicon nitride PIC-based single-channel swept source OCT system operating at 840 nm was implemented and used to acquire in-vivo tomograms of a human retina. The fabrication of the PIC was done via CMOS-compatible plasma-enhanced chemical vapor deposition to allow future monolithic co-integration with photodiodes and read-out electronics. A performance analysis using the results of the implemented photonic building blocks shows a potential tenfold increase of the acquisition speed for a multi-channel system compared to an ideal lossless single-channel system with the same signal-to-noise ratio.
△ Less
Submitted 15 October, 2020;
originally announced November 2020.
-
Broadband low loss and ultra-low crosstalk waveguide crossings based on multimode interferometer for 840 nm operation
Authors:
Stefan Nevlacsil,
Paul Muellner,
Martin Sagmeister,
Jochen Kraft,
Rainer Hainberger
Abstract:
Broadband low loss and ultra-low crosstalk waveguide crossings are a crucial component for photonic integrated circuits to allow a higher integration density of functional components and an increased flexibility in the layout. We report the design of optimized silicon nitride waveguide crossings based on multimode interferometer structures for intersecting light paths of TE/TE-like, TM/TM-like and…
▽ More
Broadband low loss and ultra-low crosstalk waveguide crossings are a crucial component for photonic integrated circuits to allow a higher integration density of functional components and an increased flexibility in the layout. We report the design of optimized silicon nitride waveguide crossings based on multimode interferometer structures for intersecting light paths of TE/TE-like, TM/TM-like and TE/TM-like polarized light in the near infrared wavelength region of 790 nm to 890 nm. The crossing design for diverse polarization modes facilitates dual polarization operation on a single chip. For all configurations the loss of a single crossing was measured to be 0.05 dB at 840 nm. Within the 100 nm bandwidth losses stayed below 0.16 dB. The crosstalk was estimated to be on the order of -60 dB by means of 3D finite difference time domain simulations.
△ Less
Submitted 26 February, 2020;
originally announced February 2020.
-
Broadband SiN asymmetric directional coupler for 840 nm operation
Authors:
Stefan Nevlacsil,
Moritz Eggeling,
Paul Muellner,
Guenther Koppitsch,
Martin Sagmeister,
Jochen Kraft,
Rainer Hainberger
Abstract:
Silicon nitride based photonic integrated circuits offer a wavelength operation window in the near infrared down to visible light, which makes them attractive for life science applications. However, they exhibit significantly different behavior in comparison with better-established silicon on insulator counterparts due to the lower index contrast. Among the most important building blocks in photon…
▽ More
Silicon nitride based photonic integrated circuits offer a wavelength operation window in the near infrared down to visible light, which makes them attractive for life science applications. However, they exhibit significantly different behavior in comparison with better-established silicon on insulator counterparts due to the lower index contrast. Among the most important building blocks in photonic integrated circuits are broadband couplers with a defined coupling ratio. We present silicon nitride broadband asymmetric directional coupler designs with 50/50 and 90/10 splitting ratios with a central wavelength of 840 nm for both TE- and TM-like polarization. We show that silicon nitride broadband asymmetric directional couplers can be designed accurately in a time efficient way by using a general implementation of the coupled mode theory. The accuracy of the coupled mode theory approach is validated with finite difference time domain simulations and confirmed with measurements of four coupler configurations.
△ Less
Submitted 29 March, 2019;
originally announced March 2019.
-
A Large Ungated TPC with GEM Amplification
Authors:
M. Berger,
M. Ball,
L. Fabbietti,
B. Ketzer,
R. Arora,
R. Beck,
F. Böhmer,
J. -C. Chen,
F. Cusanno,
S. Dørheim,
J. Hehner,
N. Herrmann,
C. Höppner,
D. Kaiser,
M. Kis,
V. Kleipa,
I. Konorov,
J. Kunkel,
N. Kurz,
Y. Leifels,
P. Müllner,
R. Münzer,
S. Neubert,
J. Rauch,
C. J. Schmidt
, et al. (6 additional authors not shown)
Abstract:
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons…
▽ More
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons, TPCs with Multiwire Proportional Chamber (MWPC) amplification have been and are widely used in experiments recording heavy-ion collisions. A significant drawback, however, is the large dead time of the order of 1 ms per event generated by the use of a gating grid, which is mandatory to prevent ions created in the amplification region from drifting back into the drift volume, where they would severely distort the drift path of subsequent tracks. For experiments with higher event rates this concept of a conventional TPC operating with a triggered gating grid can therefore not be applied without a significant loss of data. A continuous readout of the signals is the more appropriate way of operation. This, however, constitutes a change of paradigm with considerable challenges to be met concerning the amplification region, the design and bandwidth of the readout electronics, and the data handling. A mandatory prerequisite for such an operation is a sufficiently good suppression of the ion backflow from the avalanche region, which otherwise limits the tracking and particle identification capabilities of such a detector. Gas Electron Multipliers (GEM) are a promising candidate to combine excellent spatial resolution with an intrinsic suppression of ions. In this paper we describe the design, construction and the commissioning of a large TPC with GEM amplification and without gating grid (GEM-TPC).
△ Less
Submitted 16 February, 2017;
originally announced February 2017.
-
Technical Design Study for the PANDA Time Projection Chamber
Authors:
M. Ball,
F. V. Böhmer,
S. Dørheim,
C. Höppner,
B. Ketzer,
I. Konorov,
S. Neubert,
S. Paul,
J. Rauch,
S. Uhl,
M. Vandenbroucke,
M. Berger,
J. -C. Berger-Chen,
F. Cusanno,
L. Fabbietti,
R. Münzer,
R. Arora,
J. Frühauf,
M. Kiš,
Y. Leifels,
V. Kleipa,
J. Hehner,
J. Kunkel,
N. Kurz,
K. Peters
, et al. (16 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
△ Less
Submitted 29 June, 2012;
originally announced July 2012.