-
A Highly Segmented Neutron Polarimeter for A1
Authors:
R. Spreckels,
M. Hoek,
U. Müller,
M. Thiel
Abstract:
A new neutron polarimeter for measuring the neutron's electric form factor was designed and constructed to complement the A1 spectrometer setup at the Mainz Microtron (MAMI). The design is based on a previous polarimeter with significant improvements to halve the error of the extracted form factor. A higher granularity of the polarimeter sections and a deeper first section on the one hand, and a f…
▽ More
A new neutron polarimeter for measuring the neutron's electric form factor was designed and constructed to complement the A1 spectrometer setup at the Mainz Microtron (MAMI). The design is based on a previous polarimeter with significant improvements to halve the error of the extracted form factor. A higher granularity of the polarimeter sections and a deeper first section on the one hand, and a faster readout employing Time-over-Threshold methods to measure the signal amplitudes combined with a high-precision FPGA-based TDC on the other hand will allow to achieve this goal. The performance of the new polarimeter during a first measurement campaign in 2019 using liquid hydrogen and deuterium targets will be discussed.
△ Less
Submitted 11 August, 2023;
originally announced August 2023.
-
High accuracy synchrotron radiation interferometry with relativistic electrons
Authors:
P. Klag,
P. Achenbach,
T. Akiyama,
R. Böhm,
M. O. Distler,
L. Doria,
P. Eckert,
A. Esser,
J. Geratz,
T. Gogami,
C. Helmel,
P. Herrmann,
M Hoek,
M. Kaneta,
Y. Konishi,
R. Kino,
W. Lauth,
H. Merkel,
M. Mizuno,
U. Müller,
S. Nagao,
S. N. Nakamura,
K. Okuyama,
J. Pochodzalla,
B. S. Schlimme
, et al. (6 additional authors not shown)
Abstract:
A high-precision hypernuclear experiment has been performed at the Mainz Microtron (MAMI) to determine the hypertriton Λ binding energy via decay-pion spectroscopy. A key element of this measurement is an accurate calibration of the magnetic spectrometers with the MAMI beam. For such an absolute calibration with small statistical and systematic uncertainties the undulator light interference method…
▽ More
A high-precision hypernuclear experiment has been performed at the Mainz Microtron (MAMI) to determine the hypertriton Λ binding energy via decay-pion spectroscopy. A key element of this measurement is an accurate calibration of the magnetic spectrometers with the MAMI beam. For such an absolute calibration with small statistical and systematic uncertainties the undulator light interference method will be applied. In this contribution the basic principle of this method is discussed and the analysis status of the measured synchrotron radiation spectra is presented
△ Less
Submitted 13 December, 2022;
originally announced December 2022.
-
Systematic treatment of hypernuclear data and application to the hypertriton
Authors:
P. Eckert,
P. Achenbach,
M. Aragones Fontbote,
T. Akiyama,
M. O. Distler,
A. Esser,
J. Geratz,
M. Hoek,
K. Itabashi,
M. Kaneta,
R. Kino,
P. Klag,
H. Merkel,
M. Mizuno,
J. Müller,
U. Müller,
S. Nagao,
S. N. Nakamura,
Y. R. Nakamura,
K. Okuyama,
J. Pochodzalla,
B. S. Schlimme,
C. Sfienti,
R. Spreckels,
M. Steinen
, et al. (4 additional authors not shown)
Abstract:
A database is under construction to provide a complete collection of published basic properties of hypernuclei such as Λ binding energies, lifetimes, or excitation energies. From these values, averages with related errors are computed in a systematic way. For each property, the overall experimental situation is depicted in form of an ideogram showing the combined probability density function of th…
▽ More
A database is under construction to provide a complete collection of published basic properties of hypernuclei such as Λ binding energies, lifetimes, or excitation energies. From these values, averages with related errors are computed in a systematic way. For each property, the overall experimental situation is depicted in form of an ideogram showing the combined probability density function of the measurements. The database is accessible via a dynamic website at https://hypernuclei.kph.uni-mainz.de with an user interface offering customizable visualizations, selections, or unit conversions. The capabilities of the database are demonstrated for the puzzling and disputed data situation of the hypertriton.
△ Less
Submitted 7 January, 2022;
originally announced January 2022.
-
Operation and characterization of a windowless gas jet target in high-intensity electron beams
Authors:
B. S. Schlimme,
S. Aulenbacher,
P. Brand,
M. Littich,
Y. Wang,
P. Achenbach,
M. Ball,
J. C. Bernauer,
M. Biroth,
D. Bonaventura,
D. Bosnar,
S. Caiazza,
M. Christmann,
E. Cline,
A. Denig,
M. O. Distler,
L. Doria,
P. Eckert,
A. Esser,
I. Friščić,
S. Gagneur,
J. Geimer,
S. Grieser,
P. Gülker,
P. Herrmann
, et al. (32 additional authors not shown)
Abstract:
A cryogenic supersonic gas jet target was developed for the MAGIX experiment at the high-intensity electron accelerator MESA. It will be operated as an internal, windowless target in the energy-recovering recirculation arc of the accelerator with different target gases, e.g., hydrogen, deuterium, helium, oxygen, argon, or xenon. Detailed studies have been carried out at the existing A1 multi-spect…
▽ More
A cryogenic supersonic gas jet target was developed for the MAGIX experiment at the high-intensity electron accelerator MESA. It will be operated as an internal, windowless target in the energy-recovering recirculation arc of the accelerator with different target gases, e.g., hydrogen, deuterium, helium, oxygen, argon, or xenon. Detailed studies have been carried out at the existing A1 multi-spectrometer facility at the electron accelerator MAMI. This paper focuses on the developed handling procedures and diagnostic tools, and on the performance of the gas jet target under beam conditions. Considering the special features of this type of target, it proves to be well suited for a new generation of high-precision electron scattering experiments at high-intensity electron accelerators.
△ Less
Submitted 16 July, 2021; v1 submitted 27 April, 2021;
originally announced April 2021.
-
Technical Design Report for the PANDA Endcap Disc DIRC
Authors:
Panda Collaboration,
F. Davi,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
F. Feldbauer,
M. Fink,
V. Freudenreich,
M. Fritsch,
F. H. Heinsius,
T. Held,
T. Holtmann,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann
, et al. (441 additional authors not shown)
Abstract:
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c.…
▽ More
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.
-
A short-orbit spectrometer for low-energy pion detection in electroproduction experiments at MAMI
Authors:
D. Baumann,
M. Ding,
I. Friščić,
R. Böhm,
D. Bosnar,
M. O. Distler,
H. Merkel,
U. Müller,
Th. Walcher,
M. Wendel
Abstract:
A new Short-Orbit Spectrometer (SOS) has been constructed and installed within the experimental facility of the A1 collaboration at Mainz Microtron (MAMI), with the goal to detect low-energy pions. It is equipped with a Browne-Buechner magnet and a detector system consisting of two helium-ethane based drift chambers and a scintillator telescope made of five layers. The detector system allows detec…
▽ More
A new Short-Orbit Spectrometer (SOS) has been constructed and installed within the experimental facility of the A1 collaboration at Mainz Microtron (MAMI), with the goal to detect low-energy pions. It is equipped with a Browne-Buechner magnet and a detector system consisting of two helium-ethane based drift chambers and a scintillator telescope made of five layers. The detector system allows detection of pions in the momentum range of 50 - 147 MeV/c, which corresponds to 8.7 - 63 MeV kinetic energy. The spectrometer can be placed at a distance range of 54 - 66 cm from the target center. Two collimators are available for the measurements, one having 1.8 msr aperture and the other having 7 msr aperture. The Short-Orbit Spectrometer has been successfully calibrated and used in coincidence measurements together with the standard magnetic spectrometers of the A1 collaboration.
△ Less
Submitted 22 August, 2017; v1 submitted 10 May, 2017;
originally announced May 2017.
-
Vertical Beam Polarization at MAMI
Authors:
B. S. Schlimme,
P. Achenbach,
K. Aulenbacher,
S. Baunack,
D. Bender,
J. Beričič,
D. Bosnar,
L. Correa,
M. Dehn,
M. O. Distler,
A. Esser,
H. Fonvieille,
I. Friščić,
B. Gutheil,
P. Herrmann,
M. Hoek,
S. Kegel,
Y. Kohl,
T. Kolar,
H. -J. Kreidel,
F. Maas,
H. Merkel,
M. Mihovilovič,
J. Müller,
U. Müller
, et al. (13 additional authors not shown)
Abstract:
For the first time a vertically polarized electron beam has been used for physics experiments at MAMI in the energy range between 180 and 855 MeV. The beam-normal single-spin asymmetry $A_{\mathrm{n}}$, which is a direct probe of higher-order photon exchange beyond the first Born approximation, has been measured in the reaction $^{12}\mathrm C(\vec e,e')^{12}\mathrm C$. Vertical polarization orien…
▽ More
For the first time a vertically polarized electron beam has been used for physics experiments at MAMI in the energy range between 180 and 855 MeV. The beam-normal single-spin asymmetry $A_{\mathrm{n}}$, which is a direct probe of higher-order photon exchange beyond the first Born approximation, has been measured in the reaction $^{12}\mathrm C(\vec e,e')^{12}\mathrm C$. Vertical polarization orientation was necessary to measure this asymmetry with the existing experimental setup. In this paper we describe the procedure to orient the electron polarization vector vertically, and the concept of determining both its magnitude and orientation with the available setup. A sophisticated method has been developed to overcome the lack of a polarimeter setup sensitive to the vertical polarization component.
△ Less
Submitted 18 January, 2017; v1 submitted 8 December, 2016;
originally announced December 2016.
-
Feasibility study for the measurement of $πN$ TDAs at PANDA in $\bar{p}p\to J/ψπ^0$
Authors:
PANDA Collaboration,
B. Singh,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
M. Fink,
F. H. Heinsius,
T. Held,
T. Holtmann,
S. Jasper,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann,
M. Kümmel,
S. Leiber
, et al. (488 additional authors not shown)
Abstract:
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as…
▽ More
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as well as the background rejection from various sources including the $\bar{p}p\toπ^+π^-π^0$ and $\bar{p}p\to J/ψπ^0π^0$ reactions are performed with PandaRoot, the simulation and analysis software framework of the PANDA experiment. It is shown that the measurement can be done at PANDA with significant constraining power under the assumption of an integrated luminosity attainable in four to five months of data taking at the maximum design luminosity.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
Technical Design Report for the: PANDA Straw Tube Tracker
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
A. Aab,
M. Albrecht,
J. Becker,
A. Csapó,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
L. Klask,
H. Koch,
B. Kopf,
S. Leiber,
M. Leyhe
, et al. (451 additional authors not shown)
Abstract:
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory an…
▽ More
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
△ Less
Submitted 4 June, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
A Large-Scale FPGA-Based Trigger and Dead-Time Free DAQ System for the Kaos Spectrometer at MAMI
Authors:
P. Achenbach,
C. Ayerbe Gayoso,
J. C. Bernauer,
R. Böhm,
D. Bosnar,
L. Debenjak,
M. O. Distler,
A. Esser,
I. Friščić,
M. Gómez Rodríguez de la Paz,
J. Hoffmann,
M. Makek,
H. Merkel,
S. Minami,
U. Müller,
L. Nungesser,
W. Ott,
J. Pochodzalla,
M. Potokar,
I. Rusanov,
T. R. Saito,
S. Sánchez Majos,
B. S. Schlimme,
S. Širca,
S. Voltz
, et al. (2 additional authors not shown)
Abstract:
The Kaos spectrometer is maintained by the A1 collaboration at the Mainz Microtron MAMI with a focus on the study of (e,e'K^+) coincidence reactions. For its electron-arm two vertical planes of fiber arrays, each comprising approximately 10 000 fibers, are operated close to zero degree scattering angle and in close proximity to the electron beam. A nearly dead-time free DAQ system to acquire timin…
▽ More
The Kaos spectrometer is maintained by the A1 collaboration at the Mainz Microtron MAMI with a focus on the study of (e,e'K^+) coincidence reactions. For its electron-arm two vertical planes of fiber arrays, each comprising approximately 10 000 fibers, are operated close to zero degree scattering angle and in close proximity to the electron beam. A nearly dead-time free DAQ system to acquire timing and tracking information has been installed for this spectrometer arm. The signals of 144 multi-anode photomultipliers are collected by 96-channel front-end boards, digitized by double-threshold discriminators and the signal time is picked up by state-of-the-art F1 time-to-digital converter chips. In order to minimize background rates a sophisticated trigger logic was implemented in newly developed Vuprom modules. The trigger performs noise suppression, signal cluster finding, particle tracking, and coincidence timing, and can be expanded for kinematical matching (e'K^+) coincidences. The full system was designed to process more than 4 000 read-out channels and to cope with the high electron flux in the spectrometer and the high count rate requirement of the detectors. It was successfully in-beam tested at MAMI in 2009.
△ Less
Submitted 1 May, 2011;
originally announced May 2011.
-
Particle tracking in kaon electroproduction with cathode-charge sampling in multi-wire proportional chambers
Authors:
P. Achenbach,
C. Ayerbe Gayoso,
J. C. Bernauer,
R. Böhm,
D. Bosnar,
M. Bösz,
L. Debenjak,
M. O. Distler,
A. Esser,
I. Friščić,
M. Gómez Rodríguez de la Paz,
M. Makek,
H. Merkel,
U. Müller,
L. Nungesser,
J. Pochodzalla,
M. Potokar,
S. Sánchez Majos,
B. S. Schlimme,
S. Širca,
M. Weinriefer
Abstract:
Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the background rate in the chambers. One way to determine the track of a charged particle through a multi-wire proportional chamber (MWPC) is the measurement of the c…
▽ More
Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the background rate in the chambers. One way to determine the track of a charged particle through a multi-wire proportional chamber (MWPC) is the measurement of the charge distribution induced on its cathodes. In practical applications of this read-out method, the algorithm to relate the measured charge distribution to the avalanche position is an important factor for the achievable position resolution and for the track reconstruction efficiency. An algorithm was developed for operating two large-sized MWPCs in a strong background environment with multiple-particle tracks. Resulting efficiencies were determined as a function of the electron beam current and on the signal amplitudes. Because of the different energy-losses of pions, kaons, and protons in the momentum range of the spectrometer the efficiencies depend also on the particle species.
△ Less
Submitted 21 April, 2011;
originally announced April 2011.
-
Test Results on the Silicon Pixel Detector for the TTF-FEL Beam Trajectory Monitor
Authors:
S. Hillert,
R. Ischebeck,
U. C. Müller,
S. Roth,
K. Hansen,
P. Holl,
S. Karstensen,
J. Kemmer,
R. Klanner,
P. Lechner,
M. Leenen,
J. S. T. Ng,
P. Schmüser,
L. Strüder
Abstract:
Test measurements on the silicon pixel detector for the beam trajectory monitor at the free electron laser of the TESLA test facility are presented. To determine the electronic noise of detector and read-out and to calibrate the signal amplitude of different pixels the 6 keV photons of the manganese K line are used. Two different methods determine the spatial accuracy of the detector: In one set…
▽ More
Test measurements on the silicon pixel detector for the beam trajectory monitor at the free electron laser of the TESLA test facility are presented. To determine the electronic noise of detector and read-out and to calibrate the signal amplitude of different pixels the 6 keV photons of the manganese K line are used. Two different methods determine the spatial accuracy of the detector: In one setup a laser beam is focused to a straight line and moved across the pixel structure. In the other the detector is scanned using a low-intensity electron beam of an electron microscope. Both methods show that the symmetry axis of the detector defines a straight line within 0.4 microns. The sensitivity of the detector to low energy X-rays is measured using a vacuum ultraviolet beam at the synchrotron light source HASYLAB. Additionally, the electron microscope is used to study the radiation hardness of the detector.
△ Less
Submitted 25 April, 2000;
originally announced April 2000.
-
Vibrational Frequencies of the 2p^2A^"_2 and 3d^2E^" States of the Triatomic Deuterium Molecule
Authors:
U. Mueller,
M. Braun,
R. Reichle,
R. F. Salzgeber
Abstract:
We investigated the vibrational energies in the 2p^2A^"_2 and 3d^2E^" states of the triatomic deuterium molecule D_3. The experiments were performed using a fast neutral beam photoionization spectrometer recently developed at Freiburg. A depletion type optical double-resonance scheme using two pulsed dye lasers was applied. The measured vibrational frequencies of the 2p^2A^"_2 state of D_3 are c…
▽ More
We investigated the vibrational energies in the 2p^2A^"_2 and 3d^2E^" states of the triatomic deuterium molecule D_3. The experiments were performed using a fast neutral beam photoionization spectrometer recently developed at Freiburg. A depletion type optical double-resonance scheme using two pulsed dye lasers was applied. The measured vibrational frequencies of the 2p^2A^"_2 state of D_3 are compared to those of H_3 and to theoretical values calculated from an ab initio potential energy surface. The data give insight into the importance of the coupling between the valence electron and the ion core.
△ Less
Submitted 18 December, 1997;
originally announced December 1997.