Skip to main content

Showing 1–7 of 7 results for author: Mäkinen, A J

Searching in archive physics. Search in all archives.
.
  1. arXiv:2007.08963  [pdf, other

    physics.comp-ph

    A general method for computing thermal magnetic noise arising from thin conducting objects

    Authors: Joonas Iivanainen, Antti J. Mäkinen, Rasmus Zetter, Koos C. J. Zevenhoven, Risto J. Ilmoniemi, Lauri Parkkonen

    Abstract: Thermal motion of charge carriers in a conducting object causes magnetic field noise that interferes with sensitive measurements nearby the conductor. In this paper, we describe a method to compute the spectral properties of the thermal magnetic noise from arbitrarily-shaped thin conducting objects. We model divergence-free currents on a conducting surface using a stream function and calculate the… ▽ More

    Submitted 17 July, 2020; originally announced July 2020.

  2. arXiv:2006.02919  [pdf, other

    physics.med-ph eess.SP

    Spatial sampling of MEG and EEG revisited: From spatial-frequency spectra to model-informed sampling

    Authors: Joonas Iivanainen, Antti J. Mäkinen, Rasmus Zetter, Matti Stenroos, Risto J. Ilmoniemi, Lauri Parkkonen

    Abstract: In this paper, we analyze spatial sampling of electro- (EEG) magnetoencephalography (MEG), where the electric or magnetic field is typically sampled on a curved surface such as the scalp. Using simulated measurements, we study the spatial-frequency content in EEG as well as in on- and off-scalp MEG. The analysis suggests that on-scalp MEG would generally benefit from three times more samples than… ▽ More

    Submitted 3 June, 2020; originally announced June 2020.

    Comments: arXiv admin note: substantial text overlap with arXiv:1912.05401

  3. arXiv:2005.10060  [pdf, other

    physics.comp-ph physics.app-ph

    Magnetic-field modeling with surface currents: Physical and computational principles of bfieldtools

    Authors: Antti J. Mäkinen, Rasmus Zetter, Joonas Iivanainen, Koos C. J. Zevenhoven, Lauri Parkkonen, Risto J. Ilmoniemi

    Abstract: Surface currents provide a general way to model static magnetic fields in source-free volumes. To facilitate the use of surface currents in magneto-quasistatic problems, we have implemented a set of computational tools in a Python package named bfieldtools. In this work, we describe the physical and computational principles of this toolset. To be able to work with surface currents of arbitrary sha… ▽ More

    Submitted 2 June, 2020; v1 submitted 20 May, 2020; originally announced May 2020.

    Comments: Updated document style, some references and wordings. 15 pages, 8 figures

    Journal ref: Journal of Applied Physics 128, 063906 (2020)

  4. arXiv:2005.10056  [pdf, other

    physics.comp-ph physics.app-ph

    Magnetic-field modeling with surface currents: Implementation and usage of bfieldtools

    Authors: Rasmus Zetter, Antti J. Mäkinen, Joonas Iivanainen, Koos C. J. Zevenhoven, Risto J. Ilmoniemi, Lauri Parkkonen

    Abstract: We present a novel open-source Python software package, bfieldtools, for magneto-quasistatic calculations with current densities on surfaces of arbitrary shape. The core functionality of the software relies on a stream-function representation of surface-current density and its discretization on a triangle mesh. Although this stream-function technique is well-known in certain fields, to date the re… ▽ More

    Submitted 1 June, 2020; v1 submitted 20 May, 2020; originally announced May 2020.

    Comments: Updated abstract, document style and reference format. 13 pages, 7 figures

  5. arXiv:2001.07178  [pdf, other

    physics.med-ph eess.IV

    Evaluating the Performance of Ultra-Low-Field MRI for In-vivo 3D Current Density Imaging of the Human Head

    Authors: Peter Hömmen, Antti J. Mäkinen, Alexander Hunold, René Machts, Jens Haueisen, Koos C. J. Zevenhoven, Risto J. Ilmoniemi, Rainer Körber

    Abstract: Magnetic fields associated with currents flowing in tissue can be measured non-invasively by means of zero-field-encoded ultra-low-field magnetic resonance imaging (ULF MRI) enabling current density imaging (CDI) and possibly conductivity map** of human head tissues. Since currents applied to a human are limited by safety regulations and only a small fraction of the current passes through the re… ▽ More

    Submitted 20 January, 2020; originally announced January 2020.

    Comments: 18 pages, 8 figures. This project has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 686865

  6. Automatic Spatial Calibration of Ultra-Low-Field MRI for High-Accuracy Hybrid MEG--MRI

    Authors: Antti J. Mäkinen, Koos C. J. Zevenhoven, Risto J. Ilmoniemi

    Abstract: With a hybrid MEG--MRI device that uses the same sensors for both modalities, the co-registration of MRI and MEG data can be replaced by an automatic calibration step. Based on the highly accurate signal model of ultra-low-field (ULF) MRI, we introduce a calibration method that eliminates the error sources of traditional co-registration. The signal model includes complex sensitivity profiles of th… ▽ More

    Submitted 15 March, 2019; originally announced March 2019.

    Comments: 11 pages, 8 figures. This work is part of the BREAKBEN project and has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 686865

    Journal ref: IEEE Transactions on Medical Imaging, vol. 38 no. 6, pp. 1317-1327, 2019

  7. arXiv:1805.08867  [pdf, other

    physics.ins-det cond-mat.supr-con eess.IV eess.SP physics.app-ph

    Superconducting receiver arrays for magnetic resonance imaging

    Authors: Koos C. J. Zevenhoven, Antti J. Mäkinen, Risto J. Ilmoniemi

    Abstract: Superconducting QUantum-Interference Devices (SQUIDs) make magnetic resonance imaging (MRI) possible in ultra-low microtesla-range magnetic fields. In this work, we investigate the design parameters affecting the signal and noise performance of SQUID-based sensors and multichannel magnetometers for MRI of the brain. Besides sensor intrinsics, various noise sources along with the size, geometry and… ▽ More

    Submitted 15 January, 2020; v1 submitted 22 May, 2018; originally announced May 2018.

    Journal ref: Biomedical Physics & Engineering Express 6:015016 (2020)