-
neuSIM4: A comprehensive GEANT4 based neutron simulation code
Authors:
J. Park,
F. C. E. Teh,
M. B. Tsang,
K. W. Brown,
Z. Chajecki,
B. Hong,
T. Lokotko,
W. G. Lynch,
J. Wieske,
K. Zhu
Abstract:
A new neutron SIMulation program based on the versatile GEANT4 toolkit, neuSIM4, has been developed to describe interactions of neutrons in the NE213 liquid scintillator from 0.1 to 3000 MeV. neuSIM4 is designed to accommodate complicated modern detector geometry setups with multiple scintillator detectors, each of which can be outfitted with more than one photo-multiplier. To address a broad spec…
▽ More
A new neutron SIMulation program based on the versatile GEANT4 toolkit, neuSIM4, has been developed to describe interactions of neutrons in the NE213 liquid scintillator from 0.1 to 3000 MeV. neuSIM4 is designed to accommodate complicated modern detector geometry setups with multiple scintillator detectors, each of which can be outfitted with more than one photo-multiplier. To address a broad spectrum of neutron energies, two new neutron interaction physics models, KSCIN and NxQMD, have been implemented in GEANT4. For neutrons with energy below 110 MeV, we incorporate a total of eleven neutron induced reaction channels on hydrogen and carbon nuclei, including nine carbon inelastic reaction channels, into KSCIN. Beyond 110 MeV, we implement a neutron induced reaction model, NxQMD, in GEANT4. We use its results as reference to evaluate other neutron-interaction physics models in GEANT4. We find that results from an existing cascade physics model (INCL) in GEANT4 agree very well with the results from NxQMD, and results from both codes agree with new and existing light response data. To connect KSCIN to NxQMD or INCL, we introduce a transition region where the contribution of neuSIM4 linearly decreases with corresponding increased contributions from NxQMD or INCL. To demonstrate the application of the new code, we simulate the light response and performance of a 2 x 2 m2 neutron detector wall array consisting of 25 2m-long scintillation bars. We are able to compare the predicted light response functions to the shape of the experimental response functions and calculate the efficiency of the neutron detector array for neutron energies up to 200 MeV. These simulation results will be pivotal for understanding the performance of modern neutron arrays with intricate geometries, especially in the measurements of neutron energy spectra in heavy-ion reactions.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Determination of energy-dependent neutron backgrounds using shadow bars
Authors:
S. N. Paneru,
K. W. Brown,
F. C. E Teh,
K. Zhu,
M. B. Tsang,
D. DellAquila,
Z. Chajecki,
W. G. Lynch,
S. Sweany,
C. Y. Tsang,
A. K. Anthony,
J. Barney,
J. Estee,
I. Gasparic,
G. Jhang,
O. B. Khanal,
J. Mandredi,
C. Y. Niu,
R. S. Wang,
J. C. Zamora
Abstract:
Understanding the neutron background is essential for determining the neutron yield from nuclear reactions. In the analysis presented here, the shadow bars are placed in front of neutron detectors to determine the energy dependent neutron background fractions. The measurement of neutron spectra with and without shadow bars is important to determine the neutron background more accurately. The neutr…
▽ More
Understanding the neutron background is essential for determining the neutron yield from nuclear reactions. In the analysis presented here, the shadow bars are placed in front of neutron detectors to determine the energy dependent neutron background fractions. The measurement of neutron spectra with and without shadow bars is important to determine the neutron background more accurately. The neutron background, along with its sources and systematic uncertainties, are explored with a focus on the impact of background models and their dependence on neutron energy.
△ Less
Submitted 19 December, 2022;
originally announced December 2022.
-
Applying machine learning to determine impact parameter in nuclear physics experiments
Authors:
C. Y. Tsang,
Yongjia Wang,
M. B. Tsang,
J. Estee,
T. Isobe,
M. Kaneko,
M. Kurata-Nishimura,
J. W. Lee,
Fupeng Li,
Qingfeng Li,
W. G. Lynch,
T. Murakami,
R. Wang,
Dan Cozma,
Rohit Kumar,
Akira Ono,
Ying-Xun Zhang
Abstract:
Machine Learning (ML) algorithms have been demonstrated to be capable of predicting impact parameter in heavy-ion collisions from transport model simulation events with perfect detector response. We extend the scope of ML application to experimental data by incorporating realistic detector response of the S$π$RIT Time Projection Chamber into the heavy-ion simulation events generated from the UrQMD…
▽ More
Machine Learning (ML) algorithms have been demonstrated to be capable of predicting impact parameter in heavy-ion collisions from transport model simulation events with perfect detector response. We extend the scope of ML application to experimental data by incorporating realistic detector response of the S$π$RIT Time Projection Chamber into the heavy-ion simulation events generated from the UrQMD model to resemble experimental data. At 3 fm, the predicted impact parameter is 2.8 fm if simulation events with perfect detector is used for training and testing; 2.4 fm if detector response is included in the training and testing, and 5.8 fm if ML algorithms trained with perfect detector is applied to testing data that has included detector response. The last result is not acceptable illustrating the importance of including the detector response in develo** the ML training algorithm. We also test the model dependence by applying the algorithms trained on UrQMD model to simulated events from four different transport models as well as using different input parameters on UrQMD model. Using data from Sn+Sn collisions at E/A=270 MeV, the ML determined impact parameters agree well with the experimentally determined impact parameter using multiplicities, except in the very central and very peripheral regions. ML selects central collision events better and allows impact parameters determination beyond the sharp cutoff limit imposed by experimental methods.
△ Less
Submitted 26 July, 2021;
originally announced July 2021.
-
Reaction Losses of Charged Particles in CsI(Tl) crystals
Authors:
S. Sweany,
W. G. Lynch,
K. Brown,
A. Anthony,
Z. Chajecki,
D. Dell'Aquila,
P. Morfouace,
F. C. E. Teh,
C. Y. Tsang,
M. B. Tsang,
R. S. Wang,
K. Zhu
Abstract:
To efficiently detect energetic light charged particles, it is common to use arrays of energy-loss telescopes involving two or more layers of detection media. As the energy of the particles increases, thicker layers are usually needed. However, carrying out measurements with thick-telescopes may require corrections for the losses due to nuclear reactions induced by the incident particles on nuclei…
▽ More
To efficiently detect energetic light charged particles, it is common to use arrays of energy-loss telescopes involving two or more layers of detection media. As the energy of the particles increases, thicker layers are usually needed. However, carrying out measurements with thick-telescopes may require corrections for the losses due to nuclear reactions induced by the incident particles on nuclei within the detector and for the scattering of incident particles out of the detector, without depositing their full energy in the active material. In this paper, we develop a method for measuring such corrections and determine the reaction and out-scattering losses for data measured with the silicon-CsI(Tl) telescopes of the newly developed HiRA10 array. The extracted efficiencies are in good agreement with model predictions using the GEANT4 reaction loss algorithm for Z=1 and Z=2 isotopes. After correcting for the HiRA10 geometry, a general function that describes the efficiencies from the reaction loss in CsI(Tl) crystals as a function of range is obtained.
△ Less
Submitted 27 July, 2021;
originally announced July 2021.
-
Beam Particle Identification and Tagging of Incompletely Stripped Heavy Beams with HEIST
Authors:
A. K. Anthony,
C. Y. Niu,
R. S. Wang,
J. Wieske,
K. W. Brown,
Z. Chajecki,
W. G. Lynch,
Y. Ayyad,
J. Barney,
T. Baumann,
D. Bazin,
S. Beceiro-Novo,
J. Boza,
J. Chen,
K. J. Cook,
M. Cortesi,
T. Ginter,
W. Mittig,
A. Pype,
M. K. Smith,
C. Soto,
C. Sumithrarachchi,
J. Swaim,
S. Sweany,
F. C. E. Teh
, et al. (4 additional authors not shown)
Abstract:
A challenge preventing successful inverse kinematics measurements with heavy nuclei that are not fully stripped is identifying and tagging the beam particles. For this purpose, the HEavy ISotope Tagger (HEIST) has been developed. HEIST utilizes two micro-channel plate timing detectors to measure time of flight, a multi-sampling ion chamber to measure energy loss, and a high purity Ge detector to i…
▽ More
A challenge preventing successful inverse kinematics measurements with heavy nuclei that are not fully stripped is identifying and tagging the beam particles. For this purpose, the HEavy ISotope Tagger (HEIST) has been developed. HEIST utilizes two micro-channel plate timing detectors to measure time of flight, a multi-sampling ion chamber to measure energy loss, and a high purity Ge detector to identify isomer decays and calibrate the isotope identification system. HEIST has successfully identified $^{198}$Pb and other nearby nuclei at energies of about 75 MeV/A. In the experiment discussed, a typical cut containing 89\% of all $^{198}$Pb$^{+80}$ in the beam had a purity of 86\%. We examine the issues of charge state contamination. The observed charge state populations of these ions are presented and are moderately well described by the charge state model GLOBAL.
△ Less
Submitted 23 August, 2021; v1 submitted 28 July, 2021;
originally announced July 2021.
-
The S$π$RIT Time Projection Chamber
Authors:
J. Barney,
J. Estee,
W. G. Lynch,
T. Isobe,
G. Jhang,
M. Kurata-Nishimura,
A. B. McIntosh,
T. Murakami,
R. Shane,
S. Tangwancharoen,
M. B. Tsang,
G. Cerizza,
M. Kaneko,
J. W. Lee,
C. Y. Tsang,
R. Wang,
C. Anderson,
H. Baba,
Z. Chajecki,
M. Famiano,
R. Hodges-Showalter,
B. Hong,
T. Kobayashi,
P. Lasko,
J. Łukasik
, et al. (15 additional authors not shown)
Abstract:
The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (S$π$RIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The S$π$RIT TPC has a 50.5 cm drift length and an 86.4 cm $\times$ 134.4 cm pad plane with 12,096…
▽ More
The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (S$π$RIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The S$π$RIT TPC has a 50.5 cm drift length and an 86.4 cm $\times$ 134.4 cm pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs readout electronics. The S$π$RIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Details of the S$π$RIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and experimental data.
△ Less
Submitted 21 May, 2020;
originally announced May 2020.
-
Value-assigned pulse shape discrimination for neutron detectors
Authors:
F. C. E. Teh,
J. -W. Lee,
K. Zhu,
K. W. Brown,
Z. Chajecki,
W. G. Lynch,
M. B. Tsang,
A. Anthony,
J. Barney,
D. Dell'Aquila,
J. Estee,
B. Hong,
G. Jhang,
O. B. Khanal,
Y. J. Kim,
H. S. Lee,
J. W. Lee,
J. Manfredi,
S. H. Nam,
C. Y. Niu,
J. H. Park,
S. Sweany,
C. Y. Tsang,
R. Wang,
H. Wu
Abstract:
Using the waveforms from a digital electronic system, an offline analysis technique on pulse shape discrimination (PSD) has been developed to improve the neutron-gamma separation in a bar-shaped NE-213 scintillator that couples to a photomultiplier tube (PMT) at each end. The new improved method, called the ``valued-assigned PSD'' (VPSD), assigns a normalized fitting residual to every waveform as…
▽ More
Using the waveforms from a digital electronic system, an offline analysis technique on pulse shape discrimination (PSD) has been developed to improve the neutron-gamma separation in a bar-shaped NE-213 scintillator that couples to a photomultiplier tube (PMT) at each end. The new improved method, called the ``valued-assigned PSD'' (VPSD), assigns a normalized fitting residual to every waveform as the PSD value. This procedure then facilitates the incorporation of longitudinal position dependence of the scintillator, which further enhances the PSD capability of the detector system. In this paper, we use radiation emitted from an AmBe neutron source to demonstrate that the resulting neutron-gamma identification has been much improved when compared to the traditional technique that uses the geometric mean of light outputs from both PMTs. The new method has also been modified and applied to a recent experiment at the National Superconducting Cyclotron Laboratory (NSCL) that uses an analog electronic system.
△ Less
Submitted 17 June, 2021; v1 submitted 15 January, 2020;
originally announced January 2020.
-
Charged particle track reconstruction with S$π$RIT Time Projection Chamber
Authors:
J. W. Lee,
G. Jhang,
G. Cerizza,
J. Barney,
J. Estee,
T. Isobe,
M. Kaneko,
M. Kurata-Nishimura,
W. G. Lynch,
T. Murakami,
C. Y. Tsang,
M. B. Tsang,
R. Wang,
B. Hong,
A. B. McIntosh,
H. Sakurai,
C. Santamaria,
R. Shane,
S. Tangwancharoen,
S. J. Yennello,
Y. Zhang
Abstract:
In this paper, we present a software framework, S$π$RITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the S$π$RIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overla…
▽ More
In this paper, we present a software framework, S$π$RITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the S$π$RIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlap** pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from $^{132}$Sn + $^{124}$Sn collision events with beam energy of 270 AMeV. Particle identification is established using $\left<dE/dx\right>$ and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.
△ Less
Submitted 10 January, 2020;
originally announced January 2020.
-
Space Charge Effects in the S$π$RIT Time Projection Chamber
Authors:
C. Y. Tsang,
J. Estee,
R. Wang,
J. Barney,
G. Jhang,
W. G. Lynch,
Z. Q. Zhang,
G. Cerizza,
T. Isobe,
M. Kaneko,
M. Kurata-Nishimura,
J. W. Lee,
T. Murakami,
M. B. Tsang,
S$π$RIT collaboration
Abstract:
Time projection chambers (TPCs) are widely used in nuclear and particle physics. They are particularly useful when measuring reaction products from heavy ion collisions. Most nuclear experiments at low energy are performed in a fixed target configuration, in which the unreacted beam will pass through the detection volume. As the beam intensity increases, the buildup of positive ions created from t…
▽ More
Time projection chambers (TPCs) are widely used in nuclear and particle physics. They are particularly useful when measuring reaction products from heavy ion collisions. Most nuclear experiments at low energy are performed in a fixed target configuration, in which the unreacted beam will pass through the detection volume. As the beam intensity increases, the buildup of positive ions created from the ionization of the detector gas by the beam creates the main source of space charge, distorting the nominal electric field of the TPC. This has a profound effect on the accuracy of the measured momenta of the emitted particles. In this paper we will discuss the magnitude of the effects and construct an observable more appropriate for fixed target experiments to study the effects. We also will present an algorithm for correcting the space charge and some of the implications it has on the momentum determination.
△ Less
Submitted 29 January, 2020; v1 submitted 23 December, 2019;
originally announced December 2019.
-
Non-linearity effects on the light-output calibration of light charged particles in CsI(Tl) scintillator crystals
Authors:
D. Dell'Aquila,
S. Sweany,
K. W. Brown,
Z. Chajecki,
W. G. Lynch,
F. C. E. Teh,
C. -Y. Tsang,
M. B. Tsang,
K. Zhu,
C. Anderson,
A. Anthony,
S. Barlini,
J. Barney,
A. Camaiani,
G. Jhang,
J. Crosby,
J. Estee,
M. Ghazali,
F. Guan,
O. Khanal,
S. Kodali,
I. Lombardo,
J. Manfredi,
L. Morelli,
P. Morfouace
, et al. (2 additional authors not shown)
Abstract:
The light output produced by light ions (Z<=4) in CsI(Tl) crystals is studied over a wide range of detected energies (E<=300 MeV). Energy-light calibration data sets are obtained with the 10 cm crystals in the recently upgraded High-Resolution Array (HiRA10). We use proton recoil data from 40,48Ca + CH2 at 28 MeV/u, 56.6 MeV/u, 39 MeV/u and 139.8 MeV/u and data from a dedicated experiment with dir…
▽ More
The light output produced by light ions (Z<=4) in CsI(Tl) crystals is studied over a wide range of detected energies (E<=300 MeV). Energy-light calibration data sets are obtained with the 10 cm crystals in the recently upgraded High-Resolution Array (HiRA10). We use proton recoil data from 40,48Ca + CH2 at 28 MeV/u, 56.6 MeV/u, 39 MeV/u and 139.8 MeV/u and data from a dedicated experiment with direct low-energy beams. We also use the punch through points of p, d, and t particles from 40,48Ca + 58,64Ni, 112,124Sn collisions reactions at 139.8 MeV/u. Non-linearities, arising in particular from Tl do** and light collection efficiency in the CsI crystals, are found to significantly affect the light output and therefore the calibration of the detector response for light charged particles, especially the hydrogen isotopes. A new empirical parametrization of the hydrogen light output, L(E,Z=1,A), is proposed to account for the observed effects. Results are found to be consistent for all 48 CsI(Tl) crystals in a cluster of 12 HiRA10 telescopes.
△ Less
Submitted 21 March, 2019; v1 submitted 18 February, 2019;
originally announced February 2019.
-
On Determining Dead Layer and Detector Thicknesses for a Position-Sensitive Silicon Detector
Authors:
J. Manfredi,
Jenny Lee,
W. G. Lynch,
C. Y. Niu,
M. B. Tsang,
C. Anderson,
J. Barney,
K. W. Brown,
Z. Chajecki,
K. P. Chan,
G. Chen,
J. Estee,
Z. Li,
C. Pruitt,
A. M. Rogers,
A. Sanetullaev,
H. Setiawan,
R. Showalter,
C. Y. Tsang,
J. R. Winkelbauer,
Z. Xiao,
Z. Xu
Abstract:
In this work, two particular properties of the position-sensitive, thick silicon detectors (known as the "E" detectors) in the High Resolution Array (HiRA) are investigated: the thickness of the dead layer on the front of the detector, and the overall thickness of the detector itself. The dead layer thickness for each E detector in HiRA is extracted using a measurement of alpha particles emitted f…
▽ More
In this work, two particular properties of the position-sensitive, thick silicon detectors (known as the "E" detectors) in the High Resolution Array (HiRA) are investigated: the thickness of the dead layer on the front of the detector, and the overall thickness of the detector itself. The dead layer thickness for each E detector in HiRA is extracted using a measurement of alpha particles emitted from a $^{212}$Pb pin source placed close to the detector surface. This procedure also allows for energy calibrations of the E detectors, which are otherwise inaccessible for alpha source calibration as each one is sandwiched between two other detectors. The E detector thickness is obtained from a combination of elastically scattered protons and an energy-loss calculation method. Results from these analyses agree with values provided by the manufacturer.
△ Less
Submitted 18 January, 2018;
originally announced January 2018.
-
A Gating Grid Driver for Time Projection Chambers
Authors:
S. Tangwancharoen,
W. G. Lynch,
J. Barney,
J. Estee,
R. Shane,
M. B. Tsang,
Y. Zhang,
T. Isobe,
M. Kurata-Nishimura,
T. Murakami,
Z. G. Xiao,
Y. F. Zhang
Abstract:
A simple but novel driver system has been developed to operate the wire gating grid of a Time Projection Chamber (TPC). This system connects the wires of the gating grid to its driver via low impedance transmission lines. When the gating grid is open, all wires have the same voltage allowing drift electrons, produced by the ionization of the detector gas molecules, to pass through to the anode wir…
▽ More
A simple but novel driver system has been developed to operate the wire gating grid of a Time Projection Chamber (TPC). This system connects the wires of the gating grid to its driver via low impedance transmission lines. When the gating grid is open, all wires have the same voltage allowing drift electrons, produced by the ionization of the detector gas molecules, to pass through to the anode wires. When the grid is closed, the wires have alternating higher and lower voltages causing the drift electrons to terminate at the more positive wires. Rapid opening of the gating grid with low pickup noise is achieved by quickly shorting the positive and negative wires to attain the average bias potential with N-type and P-type MOSFET switches. The circuit analysis and simulation software SPICE shows that the driver restores the gating grid voltage to 90% of the opening voltage in less than 0.20 $μ$s. When tested in the experimental environment of a time projection chamber larger termination resistors were chosen so that the driver opens the gating grid in 0.35 $μ$s. In each case, opening time is basically characterized by the RC constant given by the resistance of the switches and terminating resistors and the capacitance of the gating grid and its transmission line. By adding a second pair of N-type and P-type MOSFET switches, the gating grid is closed by restoring 99% of the original charges to the wires within 3 $μ$s.
△ Less
Submitted 20 December, 2016;
originally announced December 2016.
-
Charged-particle detection efficiencies of close-packed CsI arrays
Authors:
P. Morfouace,
W. G. Lynch,
M. B. Tsang
Abstract:
Detector efficiency determination is essential to correct the measured yields and extract reliable cross sections of particles emitted in nuclear reactions. We investigate the efficiencies for measuring the full energies of light charged particle in arrays of CsI crystals employed in particle detection arrays such as HiRA, LASSA and MUST2. We perform these simulations with a GEANT4 Monte Carlo tra…
▽ More
Detector efficiency determination is essential to correct the measured yields and extract reliable cross sections of particles emitted in nuclear reactions. We investigate the efficiencies for measuring the full energies of light charged particle in arrays of CsI crystals employed in particle detection arrays such as HiRA, LASSA and MUST2. We perform these simulations with a GEANT4 Monte Carlo transport code implemented in the NPTool framework. Both Coulomb multiple scattering and nuclear reactions within the crystal can significantly reduce the efficiency of detecting the full energy of high energy particles. The calculated efficiencies decrease exponentially as a function of the range of the particle and are quite similar for both the hydrogen ($p, d, t$) and helium ($^3$He, $α$) isotopes. The use of a close-packed array introduces significant position dependent efficiency losses at the interior boundaries between crystals that need to be considered in the design of an array and in the efficiency corrections of measured energy spectra.
△ Less
Submitted 5 December, 2016;
originally announced December 2016.
-
KATANA - a charge-sensitive triggering system for the S$π$RIT experiment
Authors:
P. Lasko,
M. Adamczyk,
J. Brzychczyk,
P. Hirnyk,
J. Łukasik,
P. Pawłowski,
K. Pelczar,
A. Snoch,
A. Sochocka,
Z. Sosin,
J. Barney,
G. Cerizza,
J. Estee,
T. Isobe,
G. Jhang,
M. Kaneko,
M. Kurata-Nishimura,
W. G. Lynch,
T. Murakami,
C. Santamaria,
M. B. Tsang,
Y. Zhang
Abstract:
KATANA - the Krakow Array for Triggering with Amplitude discrimiNAtion - has been built and used as a trigger and veto detector for the S$π$RIT TPC at RIKEN. Its construction allows operating in magnetic field and providing fast response for ionizing particles, giving the approximate forward multiplicity and charge information. Depending on this information, trigger and veto signals are generated.…
▽ More
KATANA - the Krakow Array for Triggering with Amplitude discrimiNAtion - has been built and used as a trigger and veto detector for the S$π$RIT TPC at RIKEN. Its construction allows operating in magnetic field and providing fast response for ionizing particles, giving the approximate forward multiplicity and charge information. Depending on this information, trigger and veto signals are generated. The article presents performance of the detector and details of its construction. A simple phenomenological parametrization of the number of emitted scintillation photons in plastic scintillator is proposed. The effect of the light output deterioration in the plastic scintillator due to the in-beam irradiation is discussed.
△ Less
Submitted 13 January, 2017; v1 submitted 21 October, 2016;
originally announced October 2016.
-
S$π$RIT: A time-projection chamber for symmetry-energy studies
Authors:
R. Shane,
A. McIntosh,
T. Isobe,
W. G. Lynch,
H. Baba,
J. Barney,
Z. Chajecki,
M. Chartier,
J. Estee,
M. Famiano,
B. Hong,
K. Ieki,
G. Jhang,
R. Lemmon,
F. Lu,
T. Murakami,
N. Nakatsuka,
M. Nishimura,
R. Olsen,
W. Powell,
H. Sakurai,
A. Taketani,
S. Tangwancharoen,
M. B. Tsang,
T. Usukura
, et al. (3 additional authors not shown)
Abstract:
A Time-Projection Chamber (TPC) called the SAMURAI Pion-Reconstruction and Ion-Tracker (S$π$RIT) has recently been constructed at Michigan State University as part of an international effort to constrain the symmetry-energy term in the nuclear Equation of State (EoS). The S$π$RIT TPC will be used in conjunction with the SAMURAI spectrometer at the Radioactive Isotope Beam Factory (RIBF) at RIKEN t…
▽ More
A Time-Projection Chamber (TPC) called the SAMURAI Pion-Reconstruction and Ion-Tracker (S$π$RIT) has recently been constructed at Michigan State University as part of an international effort to constrain the symmetry-energy term in the nuclear Equation of State (EoS). The S$π$RIT TPC will be used in conjunction with the SAMURAI spectrometer at the Radioactive Isotope Beam Factory (RIBF) at RIKEN to measure yield ratios for pions and other light isospin multiplets produced in central collisions of neutron-rich heavy ions, such as $^{132}$Sn + $^{124}$Sn. The S$π$RIT TPC can function both as a TPC detector and as an active target. It has a vertical drift length of 50 cm, parallel to the magnetic field. Gas multiplication is achieved through the use of a multi-wire anode. Image charges are produced in the 12096 pads, and are read out with the recently developed Generic Electronics for TPCs.
△ Less
Submitted 22 September, 2014;
originally announced September 2014.
-
Tracking rare-isotope beams with microchannel plates
Authors:
A. M. Rogers,
A. Sanetullaev,
W. G. Lynch,
M. B. Tsang,
J. Lee,
D. Bazin,
D. Coupland,
V. Henzl,
D. Henzlova,
M. Kilburn,
M. S. Wallace,
M. Youngs,
F. Delaunay,
M. Famiano,
D. Shapira,
K. L. Jones,
K. T. Schmitt,
Z. Y. Sun
Abstract:
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams,…
▽ More
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams, the magnetic field strength between the secondary-electron accelerating foil and the microchannel plate had to be increased substantially. Results from an experiment using a 37-MeV/nucleon ${}^{56}$Ni beam show that the tracking system can achieve sub-nanosecond timing resolution and a position resolution of $\sim$1 mm for beam intensities up to $5\times10^{5}$ pps.
△ Less
Submitted 11 September, 2013;
originally announced September 2013.