Skip to main content

Showing 1–9 of 9 results for author: Luukka, P

Searching in archive physics. Search in all archives.
.
  1. arXiv:2212.04773  [pdf, other

    physics.ins-det physics.med-ph

    Pixelated silicon detector for radiation beam profile measurements

    Authors: Joonas Tikkanen, Stefanie Kirschenmann, Nikita Kramarenko, Erik Brücken, Pirkitta Koponen, Panja Luukka, Teemu Siiskonen, Raimo Turpeinen, Jennifer Ott

    Abstract: A pixelated silicon detector, developed originally for particle physics experiments, was used for a beam profile measurement of a Co-60 irradiator in a water phantom. The beam profile was compared to a profile measured with a pinpoint ionization chamber. The differences in the pixel detector and pinpoint chamber relative profiles were within approximately 0.02, and after calculating correction fac… ▽ More

    Submitted 9 December, 2022; originally announced December 2022.

  2. arXiv:2211.09158  [pdf, other

    physics.ins-det hep-ex

    Characterisation of Gamma-irradiated MCz-Silicon Detectors with a High-$K$ Negative Oxide as Field Insulator

    Authors: S. Bharthuar, M. Bezak, E. Brücken, A Gädda, M. Golovleva, A. Karadzhinova-Ferrer, A. Karjalainen, N. Kramarenko, S. Kirschenmann, P. Luukka, J. Ott, E. Tuominen, M. Väänänen

    Abstract: The high-luminosity operation of the Tracker in the Compact Muon Solenid (CMS) detector at the Large Hadron Collider (LHC) experiment calls for the development of silicon-based sensors. This involves implementation of AC-coupling to micro-scale pixel sensor areas to provide enhanced isolation of radiation-induced leakage currents. The motivation of this study is the development of AC-pixel sensors… ▽ More

    Submitted 19 November, 2022; v1 submitted 16 November, 2022; originally announced November 2022.

  3. Quality assessment of Cadmium Telluride as a detector material for multispectral medical imaging

    Authors: S. Kirschenmann, M. Bezak, S. Bharthuar, E. Brücken, M. Golovleva, A. Gädda, M. Kalliokoski, A. Karadzhinova-Ferrer, P. Koponen, N. Kramarenko, P. Luukka, J. Ott, J. Tikkanen, R. Turpeinen, A. Winkler

    Abstract: Cadmium Telluride (CdTe) is a high-Z material with excellent photon radiation absorption properties, making it a promising material to include in radiation detection technologies. However, the brittleness of CdTe crystals as well as their varying concentration of defects necessitate a thorough quality assessment before the complex detector processing procedure. We present our quality assessment of… ▽ More

    Submitted 26 January, 2022; originally announced January 2022.

    Comments: This is the Accepted Manuscript version of an article accepted for publication in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/1748-0221/17/01/C01070

    Journal ref: JINST 17 C01070 (2022)

  4. Employing infrared microscopy (IRM) in combination with a pre-trained neural network to visualise and analyse the defect distribution in Cadmium Telluride crystals

    Authors: S. Kirschenmann, S. Bharthuar, E. Brücken, M. Golovleva, A. Gädda, M. Kalliokoski, P. Luukka, J. Ott, A. Winkler

    Abstract: While Cadmium Telluride (CdTe) excels in terms of photon radiation absorption properties and outperforms silicon (Si) in this respect, the crystal growth, characterization and processing into a radiation detector is much more complicated. Additionally, large concentrations of extended crystallographic defects, such as grain boundaries, twins, and tellurium (Te) inclusions, vary from crystal to cry… ▽ More

    Submitted 18 August, 2021; originally announced August 2021.

    Comments: This is the Accepted Manuscript version of an article accepted for publication in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/1748-0221/16/08/P08044

    Journal ref: JINST 16 P08044 (2021)

  5. arXiv:2001.02726  [pdf, other

    physics.ins-det physics.med-ph

    Multispectral Photon-Counting for Medical Imaging and Beam Characterization

    Authors: E. Brücken, S. Bharthuar, M. Emzir, M. Golovleva, A. Gädda, R. Hostettler, J. Härkönen, S. Kirschenmann, V. Litichevskyi, P. Luukka, L. Martikainen, T. Naaranoja, I. Nincă, J. Ott, H. Petrow, Z. Purisha, T. Siiskonen, S. Särkkä, J. Tikkanen, T. Tuuva, A. Winkler

    Abstract: We present the current status of our project of develo** a photon counting detector for medical imaging. An example motivation lays in producing a monitoring and dosimetry device for boron neutron capture therapy, currently not commercially available. Our approach combines in-house developed detectors based on cadmium telluride or thick silicon with readout chip technology developed for particle… ▽ More

    Submitted 20 February, 2020; v1 submitted 8 January, 2020; originally announced January 2020.

    Journal ref: JINST 15 C02024 (2020)

  6. arXiv:1706.00222  [pdf, other

    physics.ins-det hep-ex

    Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

    Authors: M. Dragicevic, M. Friedl, J. Hrubec, H. Steininger, A. Gädda, J. Härkönen, T. Lampén, P. Luukka, T. Peltola, E. Tuominen, E. Tuovinen, A. Winkler, P. Eerola, T. Tuuva, G. Baulieu, G. Boudoul, L. Caponetto, C. Combaret, D. Contardo, T. Dupasquier, G. Gallbit, N. Lumb, L. Mirabito, S. Perries, M. Vander Donckt , et al. (462 additional authors not shown)

    Abstract: A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator… ▽ More

    Submitted 1 June, 2017; originally announced June 2017.

    Report number: CMS-NOTE-2017-002

  7. Trap** in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Authors: W. Adam, T. Bergauer, M. Dragicevic, M. Friedl, R. Fruehwirth, M. Hoch, J. Hrubec, M. Krammer, W. Treberspurg, W. Waltenberger, S. Alderweireldt, W. Beaumont, X. Janssen, S. Luyckx, P. Van Mechelen, N. Van Remortel, A. Van Spilbeeck, P. Barria, C. Caillol, B. Clerbaux, G. De Lentdecker, D. Dobur, L. Favart, A. Grebenyuk, Th. Lenzi , et al. (663 additional authors not shown)

    Abstract: The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi… ▽ More

    Submitted 7 May, 2015; originally announced May 2015.

    Journal ref: 2016 JINST 11 P04023

  8. Processing and characterization of epitaxial GaAs radiation detectors

    Authors: X. Wu, T. Peltola, T. Arsenovich, A. Gädda, J. Härkönen, A. Junkes, A. Karadzhinova, P. Kostamo, H. Lipsanen, P. Luukka, M. Mattila, S. Nenonen, T. Riekkinen, E. Tuominen, A. Winkler

    Abstract: GaAs devices have relatively high atomic numbers (Z=31, 33) and thus extend the X-ray absorption edge beyond that of Si (Z=14) devices. In this study, radiation detectors were processed on GaAs substrates with 110 $μ\textrm{m}$ - 130 $μ\textrm{m}$ thick epitaxial absorption volume. Thick undoped and heavily doped p$^+$ epitaxial layers were grown using a custom-made horizontal Chloride Vapor Phase… ▽ More

    Submitted 13 March, 2015; originally announced March 2015.

    Comments: 7 pages, 10 figures, 10th International Conference on Radiation Effects on Semiconductor Materials, Detectors and Devices (RESMDD14), 8-10 October, Firenze, Italy

  9. arXiv:physics/0306015  [pdf, ps, other

    physics.ins-det

    Novel Data Acquisition System for Silicon Tracking Detectors

    Authors: L. A. Wendland, K. Banzuzi, S. Czellar, A. Heikkinen, J. Harkonen, P. Johansson, V. Karimaki, T. Lampen, P. Luukka, P. Mehtala, J. Niku, S. Nummela, J. Nysten, J. Simpura, E. Tuovinen, E. Tuominen, J. Tuominiemi, D. Ungaro, T. Vaarala, M. Voutilainen, A. Zibellini

    Abstract: We have developed a novel data acquisition system for measuring tracking parameters of a silicon detector in a particle beam. The system is based on a commercial Analog-to-Digital VME module and a PC Linux based Data Acquisition System. This DAQ is realized with C++ code using object-oriented techniques. Track parameters for the beam particles were reconstructed using off-line analysis code and… ▽ More

    Submitted 2 June, 2003; originally announced June 2003.

    Comments: Talk from the 2003 Computing in High Energy and Nuclear Physics (CHEP03), La Jolla, Ca, USA, March 2003, 6 pages, LaTeX, 5 eps figures. PSN TUGP006