-
Optomechanical cavities based on epitaxial GaP on nominally (001)-oriented Si
Authors:
Paula Mouriño,
Laura Mercadé,
Miguel Sinusía Lozano,
Raquel Resta,
Amadeu Griol,
Karim Ben Saddik,
Enrique Barrigón,
Sergio Fernández-Garrido,
Basilio Javier García,
Alejandro Martínez,
Víctor J. Gómez
Abstract:
Gallium phosphide (GaP) has recently received considerable attention as a suitable material for building photonic integrated circuits due to its remarkable optical and piezoelectric properties. Usually, GaP is grown epitaxially on III-V substrates to keep its crystallinity and later transferred to silicon wafers for further processing. Here, an alternative promising route for the fabrication of op…
▽ More
Gallium phosphide (GaP) has recently received considerable attention as a suitable material for building photonic integrated circuits due to its remarkable optical and piezoelectric properties. Usually, GaP is grown epitaxially on III-V substrates to keep its crystallinity and later transferred to silicon wafers for further processing. Here, an alternative promising route for the fabrication of optomechanical (OM) cavities on GaP epitaxially grown on nominally (001)-oriented Si is introduced by using a two-step process consisting of a low-temperature etching of GaP followed by selective etching of the underneath silicon. The low-temperature (-30 $^o$C) during the dry-etching of GaP hinders the lateral etching rate, preserving the pattern with a deviation between the design and the pattern in the GaP layer lower than 5 %, avoiding the complex process of transferring and bonding a GaP wafer to a silicon-on-insulator wafer. To demonstrate the quality and feasibility of the proposed fabrication route, suspended OM cavities are fabricated and experimentally characterized. The cavities show optical quality factors between 10$^3$ and 10$^4$, and localized mechanical resonances at frequencies around 3.1 GHz. Both optical and mechanical resonances are close to those previously reported on crystalline GaP structures. These results suggest a simple and low-cost way to build GaP-based photonic devices directly integrated on industry-standard Si(001) photonic wafers.
△ Less
Submitted 28 March, 2024;
originally announced March 2024.
-
A robust shape model for blood vessels analysis
Authors:
Pau Romero,
Abel Pedrós,
Rafael Sebastian,
Miguel Lozano,
Ignacio García-Fernández
Abstract:
The availability of digital twins for the cardiovascular system will enable insightful computational tools both for research and clinical practice. This, however, demands robust and well defined models and methods for the different steps involved in the process. We present a vessel coordinate system (VCS) that enables the unanbiguous definition of locations in a vessel section, by adapting the ide…
▽ More
The availability of digital twins for the cardiovascular system will enable insightful computational tools both for research and clinical practice. This, however, demands robust and well defined models and methods for the different steps involved in the process. We present a vessel coordinate system (VCS) that enables the unanbiguous definition of locations in a vessel section, by adapting the idea of cylindrical coordinates to the vessel geometry. Using the VCS model, point correspondence can be defined among different samples of a cohort, allowing data transfer, quantitative comparison, shape coregistration or population analysis. Furthermore, the VCS model allows for the generation of specific meshes (e.g. cylindrical grids, ogrids) necessary for an accurate reconstruction of the geometries used in fluid simulations. We provide the technical details for coordinates computation and discuss the assumptions taken to guarantee that they are well defined. The VCS model is tested in a series of applications. We present a robust, low dimensional, patient specific vascular model and use it to study phenotype variability analysis of the thoracic aorta within a cohort of patients. Point correspondence is exploited to build an haemodynamics atlas of the aorta for the same cohort. The atlas originates from fluid simulations (Navier-Stokes with Finite Volume Method) conducted using OpenFOAMv10. We finally present a relevant discussion on the VCS model, which covers its impact in important areas such as shape modeling and computer fluids dynamics (CFD).
△ Less
Submitted 23 February, 2024; v1 submitted 1 November, 2023;
originally announced November 2023.
-
Probing Inhomogeneous Cuprate Superconductivity by Terahertz Josephson Echo Spectroscopy
Authors:
Albert Liu,
Danica Pavicevic,
Marios H. Michael,
Alex G. Salvador,
Pavel E. Dolgirev,
Michael Fechner,
Ankit S. Disa,
Pedro M. Lozano,
Qiang Li,
Genda D. Gu,
Eugene Demler,
Andrea Cavalleri
Abstract:
Inhomogeneities play a crucial role in determining the properties of quantum materials. Yet methods that can measure these inhomogeneities are few, and apply to only a fraction of the relevant microscopic phenomena. For example, the electronic properties of cuprate materials are known to be inhomogeneous over nanometer length scales, although questions remain about how such disorder influences sup…
▽ More
Inhomogeneities play a crucial role in determining the properties of quantum materials. Yet methods that can measure these inhomogeneities are few, and apply to only a fraction of the relevant microscopic phenomena. For example, the electronic properties of cuprate materials are known to be inhomogeneous over nanometer length scales, although questions remain about how such disorder influences supercurrents and their dynamics. Here, two-dimensional terahertz spectroscopy is used to study interlayer superconducting tunneling in near-optimally-doped La1.83Sr0.17CuO4. We isolate a 2 THz Josephson echo signal with which we disentangle intrinsic lifetime broadening from extrinsic inhomogeneous broadening. We find that the Josephson plasmons are only weakly inhomogeneously broadened, with an inhomogeneous linewidth that is three times smaller than their intrinsic lifetime broadening. This extrinsic broadening remains constant up to 0.7Tc, above which it is overcome by the thermally-increased lifetime broadening. Crucially, the effects of disorder on the Josephson plasma resonance are nearly two orders of magnitude smaller than the in-plane variations in the superconducting gap in this compound, which have been previously documented using Scanning Tunnelling Microscopy (STM) measurements. Hence, even in the presence of significant disorder in the superfluid density, the finite frequency interlayer charge fluctuations exhibit dramatically reduced inhomogeneous broadening. We present a model that relates disorder in the superfluid density to the observed lifetimes.
△ Less
Submitted 28 August, 2023;
originally announced August 2023.
-
Plasma induced surface modification of sapphire and its influence on graphene grown by PECVD
Authors:
Miguel Sinusia Lozano,
Ignacio Bernat-Montoya,
Todora Ivanova Angelova,
Alberto Boscá Mojena,
Francisco J. Díaz-Fernández,
Miroslavna Kovylina,
Alejandro Martínez,
Elena Pinilla Cienfuegos,
Víctor J. Gómez
Abstract:
The catalyst-free synthesis of graphene on dielectrics prevents the damage induced by the transfer process. Although challenging, to master this synthesis would boost the integration of graphene on consumer electronics since defects hinder its optoelectronic properties. In this work, the influence of the different surface terminations of c-plane sapphire substrates on the synthesis of graphene via…
▽ More
The catalyst-free synthesis of graphene on dielectrics prevents the damage induced by the transfer process. Although challenging, to master this synthesis would boost the integration of graphene on consumer electronics since defects hinder its optoelectronic properties. In this work, the influence of the different surface terminations of c-plane sapphire substrates on the synthesis of graphene via plasma-enhanced chemical vapour deposition (PECVD) is studied. The different terminations of the sapphire surface are controlled by a plasma etching process. A design of experiments (DoE) procedure was carried out to evaluate the major effects governing the etching process of four different parameters: i.e. discharge power, time, pressure and gas employed. In the characterization of the substrate, two sapphire surface terminations were identified and characterized by means of contact angle measurements, being a hydrophilic (hydrophobic) surface the fingerprint of an Al- (OH-) terminated surface, respectively. The defects within the synthesized graphene were analysed by Raman spectroscopy. Notably, we found that the ID/IG ratio decreases for graphene grown on OH-terminated surfaces. Furthermore, two different regimes related to the nature of graphene defects were identified and depending on the sapphire terminated surface are bound either to vacancy or boundary like defects. Finally, studying the density of defects and the crystallite area, as well as their relationship with the sapphire surface termination paves the way for increasing the crystallinity of the synthesized graphene.
△ Less
Submitted 1 March, 2023;
originally announced March 2023.
-
Laser-guided lightning
Authors:
Aurélien Houard,
Pierre Walch,
Thomas Produit,
Victor Moreno,
Benoit Mahieu,
Antonio Sunjerga,
Clemens Herkommer,
Amirhossein Mostajabi,
Ugo Andral,
Yves-Bernard André,
Magali Lozano,
Laurent Bizet,
Malte C. Schroeder,
Guillaume Schimmel,
Michel Moret,
Mark Stanley,
W. A. Rison,
Oliver Maurice,
Bruno Esmiller,
Knut Michel,
Walter Haas,
Thomas Metzger,
Marcos Rubinstein,
Farhad Rachidi,
Vernon Cooray
, et al. (3 additional authors not shown)
Abstract:
Electric currents circulating between charged clouds and the earth surface during lightning discharges are responsible for considerable damages and casualties. It is therefore important to develop better protection methods in addition to the traditional Franklin rod. Here we present the first demonstration that filaments formed by short and intense laser pulses can guide lightning discharges over…
▽ More
Electric currents circulating between charged clouds and the earth surface during lightning discharges are responsible for considerable damages and casualties. It is therefore important to develop better protection methods in addition to the traditional Franklin rod. Here we present the first demonstration that filaments formed by short and intense laser pulses can guide lightning discharges over considerable distances. We believe that this experimental breakthrough will lead to progress in lightning protection and lightning physics. An experimental campaign was carried out on the Säntis Mountain in Northeastern Switzerland during the Summer of 2021 with a high repetition rate terawatt laser. The guiding of an upward negative lightning leader over a distance of 50 m was recorded by two separate high-speed cameras. The guiding of negative lightning leaders by laser filaments was corroborated in three other instances by VHF interferometric measurements, and the number of X-ray bursts detected during guided lightning events was significantly increased. While this research field has been very active for more than 20 years with many research groups around the world working to achieve this goal, this result demonstrates lightning guiding by lasers, which may lead to the development of a laser lightning rod. This work paves the way for new atmospheric applications of ultrashort lasers and represents a significant step forward in the development of a laser based lightning protection for airports, launchpads or large infrastructures.
△ Less
Submitted 19 January, 2023; v1 submitted 8 July, 2022;
originally announced July 2022.
-
A method for approximating optimal statistical significances with machine-learned likelihoods
Authors:
Ernesto Arganda,
Xabier Marcano,
Víctor Martín Lozano,
Anibal D. Medina,
Andres D. Perez,
Manuel Szewc,
Alejandro Szynkman
Abstract:
Machine-learning techniques have become fundamental in high-energy physics and, for new physics searches, it is crucial to know their performance in terms of experimental sensitivity, understood as the statistical significance of the signal-plus-background hypothesis over the background-only one. We present here a simple method that combines the power of current machine-learning techniques to face…
▽ More
Machine-learning techniques have become fundamental in high-energy physics and, for new physics searches, it is crucial to know their performance in terms of experimental sensitivity, understood as the statistical significance of the signal-plus-background hypothesis over the background-only one. We present here a simple method that combines the power of current machine-learning techniques to face high-dimensional data with the likelihood-based inference tests used in traditional analyses, which allows us to estimate the sensitivity for both discovery and exclusion limits through a single parameter of interest, the signal strength. Based on supervised learning techniques, it can perform well also with high-dimensional data, when traditional techniques cannot. We apply the method to a toy model first, so we can explore its potential, and then to a LHC study of new physics particles in dijet final states. Considering as the optimal statistical significance the one we would obtain if the true generative functions were known, we show that our method provides a better approximation than the usual naive counting experimental results.
△ Less
Submitted 9 November, 2022; v1 submitted 12 May, 2022;
originally announced May 2022.
-
Estimation of absorbed dose in organs using Waza-AriV2 web-based software in head CT scans
Authors:
Juan Miguel Lozano,
Harley Alejo Martinez,
Edison Salazar,
Maria Esperanza Castellanos
Abstract:
Recently, Yamashita et al. reported direct measurements of ionizing radiation doses to individual organs in postmortem (using OSL dosimetry) that were exposed in the most frequent clinical CT scan protocols, corresponding to the whole body, head, thorax and abdomen. The authors compare the experimental results with the values calculated in the Waza-AriV2 software, which is a system based on the Mo…
▽ More
Recently, Yamashita et al. reported direct measurements of ionizing radiation doses to individual organs in postmortem (using OSL dosimetry) that were exposed in the most frequent clinical CT scan protocols, corresponding to the whole body, head, thorax and abdomen. The authors compare the experimental results with the values calculated in the Waza-AriV2 software, which is a system based on the MonteCarlo method that performs the estimation of organ doses from the exposure parameters used in the CT equipment. However, the results of the absorbed doses calculated in each examination had significant variations with respect to the doses measured directly in postmortem. In this communication, we made a calculation under the correct interpretation in one of the acquisition parameters (mA) which leads to a significant discrepancy between the estimated and measured values reported by Yamashita et al. We also make the comparison between the Waza-AriV2 and NCICT software.
△ Less
Submitted 10 September, 2021; v1 submitted 3 September, 2021;
originally announced September 2021.
-
Integration of hydrothermal liquefaction and carbon capture and storage for the production of advanced liquid biofuels with negative CO2 emissions
Authors:
E. M. Lozano,
T. H. Pedersen,
L. A. Rosendahl
Abstract:
The technical and economic feasibility to deliver sustainable liquid biocrude through hydrothermal liquefaction (HTL) while enabling negative carbon dioxide emissions is evaluated in this paper, looking into the potential of the process in the context of negative emission technologies (NETs) for climate change mitigation. In the HTL process, a gas phase consisting mainly of carbon dioxide is obtai…
▽ More
The technical and economic feasibility to deliver sustainable liquid biocrude through hydrothermal liquefaction (HTL) while enabling negative carbon dioxide emissions is evaluated in this paper, looking into the potential of the process in the context of negative emission technologies (NETs) for climate change mitigation. In the HTL process, a gas phase consisting mainly of carbon dioxide is obtained as a side product driving a potential for the implementation of carbon capture and storage in the process (BECCS) that has not been explored yet in the existing literature and is undertaken in this study. To this end, the process is divided in a standard HTL base and a carbon capture add-on, having forestry residues as feedstock. The Selexol technology is adapted in a novel scheme to simultaneously separate the CO2 from the HTL gas and recover the excess hydrogen for biocrude upgrading. The cost evaluation indicates that the additional cost of the carbon capture can be compensated by revenues from the excess process heat and the European carbon allowance market. The impact in the MFSP of the HTL base case ranges from -7% to 3%, with -15% in the most favorable scenario, with a GHG emissions reduction potential of 102-113% compared to the fossil baseline. These results show that the implementation of CCS in the HTL process is a promising alternative from technical, economic and environmental perspective in future scenarios in which advanced liquid biofuels and NETs are expected to play a role in the decarbonization of the energy system.
△ Less
Submitted 8 September, 2020;
originally announced September 2020.
-
The observation of vibrating pear shapes in radon nuclei: update
Authors:
P. A. Butler,
L. P. Gaffney,
P. Spagnoletti,
J. Konki,
M. Scheck,
J. F. Smith,
K. Abrahams,
M. Bowry,
J. Cederkäll,
T. Chupp,
G. De Angelis,
H. De Witte,
P. E. Garrett,
A. Goldkuhle,
C. Henrich,
A. Illana,
K. Johnston,
D. T. Joss,
J. M. Keatings,
N. A. Kelly,
M. Komorowska,
T. Kröll,
M. Lozano,
B. S. Nara Singh,
D. O'Donnell
, et al. (19 additional authors not shown)
Abstract:
There is a large body of evidence that atomic nuclei can undergo octupole distortion and assume the shape of a pear. This phenomenon is important for measurements of electric-dipole moments of atoms, which would indicate CP violation and hence probe physics beyond the standard model of particle physics. Isotopes of both radon and radium have been identified as candidates for such measurements. Her…
▽ More
There is a large body of evidence that atomic nuclei can undergo octupole distortion and assume the shape of a pear. This phenomenon is important for measurements of electric-dipole moments of atoms, which would indicate CP violation and hence probe physics beyond the standard model of particle physics. Isotopes of both radon and radium have been identified as candidates for such measurements. Here, we have observed the low-lying quantum states in $^{224}$Rn and $^{226}$Rn by accelerating beams of these radioactive nuclei. We report here additional states not assigned in our 2019 publication. We show that radon isotopes undergo octupole vibrations but do not possess static pear-shapes in their ground states. We conclude that radon atoms provide less favourable conditions for the enhancement of a measurable atomic electric-dipole moment.
△ Less
Submitted 10 June, 2020; v1 submitted 23 March, 2020;
originally announced March 2020.
-
Evolution of Octupole Deformation in Radium Nuclei from Coulomb Excitation of Radioactive $^{222}$Ra and $^{228}$Ra Beams
Authors:
P. A. Butler,
L. P. Gaffney,
P. Spagnoletti,
K. Abrahams,
M. Bowry,
J. Cederkäll,
G. De Angelis,
H. De Witte,
P. E. Garrett,
A. Goldkuhle,
C. Henrich,
A. Illana,
K. Johnston,
D. T. Joss,
J. M. Keatings,
N. A. Kelly,
M. Komorowska,
J. Konki,
T. Kröll,
M. Lozano,
B. S. Nara Singh,
D. O'Donnell,
J. Ojala,
R. D. Page,
L. G. Pedersen
, et al. (18 additional authors not shown)
Abstract:
There is sparse direct experimental evidence that atomic nuclei can exhibit stable pear shapes arising from strong octupole correlations. In order to investigate the nature of octupole collectivity in radium isotopes, electric octupole ($E3$) matrix elements have been determined for transitions in $^{222,228}$Ra nuclei using the method of sub-barrier, multi-step Coulomb excitation. Beams of the ra…
▽ More
There is sparse direct experimental evidence that atomic nuclei can exhibit stable pear shapes arising from strong octupole correlations. In order to investigate the nature of octupole collectivity in radium isotopes, electric octupole ($E3$) matrix elements have been determined for transitions in $^{222,228}$Ra nuclei using the method of sub-barrier, multi-step Coulomb excitation. Beams of the radioactive radium isotopes were provided by the HIE-ISOLDE facility at CERN. The observed pattern of $E$3 matrix elements for different nuclear transitions is explained by describing $^{222}$Ra as pear-shaped with stable octupole deformation, while $^{228}$Ra behaves like an octupole vibrator.
△ Less
Submitted 27 January, 2020;
originally announced January 2020.
-
Generic approach for the modeling of liquefied thermochemical products and biomass heat of formation. Case study: HTL biocrude, Pyrolysis oil and assessment of energy requirements
Authors:
Eliana M. Lozano,
Thomas H. Pedersen,
Lasse Rosendahl
Abstract:
A generic approach is proposed for the estimation of advanced biocrudes properties from liquefied biomass and the enthalpy of formation of biomass feedstocks applicable to the modeling of biomass conversion processes where the exact stoichiometry and kinetics are unknown,such as pyrolysis, solvolysis and hydrothermal liquefaction (HTL) . The enthalpy of formation of the biomass is estimated throug…
▽ More
A generic approach is proposed for the estimation of advanced biocrudes properties from liquefied biomass and the enthalpy of formation of biomass feedstocks applicable to the modeling of biomass conversion processes where the exact stoichiometry and kinetics are unknown,such as pyrolysis, solvolysis and hydrothermal liquefaction (HTL) . The enthalpy of formation of the biomass is estimated through a direct correlation based on ultimate and proximate analysis, whose parameters can easily be fitted with experimental data available from sources such as the Phillys database for different biomass types and implemented in process simulators such as Aspen Plus. For the biocrude modeling, a multi-objective optimization model is proposed that refines the selection of model compounds to match measured bulk thermochemical and physical properties. Parameter fitting and multi-objective optimization were both performed in Matlab and the codes are available in the supplementary material. As a case study, the optimization model was applied to two different oils obtained via HTL and pyrolysis of woody biomass. The first case was further studied in order to estimate the impact of the proposed models in the energy requirements. The process was implemented in Aspen Plus but the methodology is applicable to other simulation tools. The results show that the methods for estimating enthalpies of formation have a high impact on the energy balance and consequently the models developed allow a more accurate estimation of the energy requirement in the reactor. This is a key element in making accurate heat integration and techno-economic analyses of thermochemical conversion processes.
△ Less
Submitted 2 August, 2019;
originally announced August 2019.
-
Relativistic near-single-cycle optics at 1 kHz
Authors:
Marie Ouillé,
Aline Vernier,
Frederik Boehle,
Maimouna Bocoum,
Magali Lozano,
Jean-Philippe Rousseau,
Zhao Cheng,
Domynikas Gustas,
Andreas Blumenstein,
Peter Simon,
Stefan Haessler,
Jérôme Faure,
Tamas Nagy,
Rodrigo Lopez-Martens
Abstract:
We present a laser source delivering waveform-controlled 1.5-cycle pulses that can be focused to relativistic intensity at 1 kHz repetition rate. These pulses are generated by nonlinear compression of high-temporal-contrast sub-25\,fs pulses from a kHz Ti:Sapphire double-chirped pulse amplifier in a stretched flexible hollow fiber compressor scaled for high peak power. The unique capabilities of t…
▽ More
We present a laser source delivering waveform-controlled 1.5-cycle pulses that can be focused to relativistic intensity at 1 kHz repetition rate. These pulses are generated by nonlinear compression of high-temporal-contrast sub-25\,fs pulses from a kHz Ti:Sapphire double-chirped pulse amplifier in a stretched flexible hollow fiber compressor scaled for high peak power. The unique capabilities of this source are demonstrated by observing carrier-envelope phase effects in laser-wakefield acceleration of relativistic electrons for the first time.
△ Less
Submitted 2 July, 2019;
originally announced July 2019.
-
Slow Extraction of Charged Ion Pulses from the REXEBIS
Authors:
Niels Bidault,
Jose Alberto Rodriguez,
Miguel Lozano,
Sergey Sadovich
Abstract:
The Isotope mass Separator On-Line DEvice (ISOLDE) facility located at CERN, produces and transports Radioactive Ion Beams (RIBs) at low or high energy through the REX/HIE-ISOLDE linear accelerator, for nuclear physics, astrophysics, solid-state physics and applied-physics purposes. Increasing the charge state of the ions is a prerequisite for efficient acceleration and is accomplished by an Elect…
▽ More
The Isotope mass Separator On-Line DEvice (ISOLDE) facility located at CERN, produces and transports Radioactive Ion Beams (RIBs) at low or high energy through the REX/HIE-ISOLDE linear accelerator, for nuclear physics, astrophysics, solid-state physics and applied-physics purposes. Increasing the charge state of the ions is a prerequisite for efficient acceleration and is accomplished by an Electron Beam Ion Source (REXEBIS). For more effective event discrimination at the experimental detectors, such as the MINIBALL spectrometer, it is advantageous to increase the pulse width of extracted ions from this EBIS. A Slow Extraction scheme is presented which uses a function comprised of discrete voltage steps to apply the extraction potential to the EBIS trap barrier. This function effectively stretches the pulse length of both stable and radioactive ion beams, with different mass-to-charge ratios and provides for extracted pulse widths in the millisecond range. Key operational parameters of the EBIS impacting the average ionic temperature and its axial energy spread are discussed, in order to anticipate changes in the resulting ion pulse time structures during experimental runs.
△ Less
Submitted 8 August, 2018;
originally announced August 2018.
-
Non-contact XUV metrology of Ru/B4C multilayer optics by means of Hartmann wavefront analysis
Authors:
Mabel Ruiz-Lopez,
Hugo Dacasa,
Benoit Mahieu,
Magali Lozano,
Philippe Zeitoun,
Davide Bleiner
Abstract:
Short-wavelength imaging, spectroscopy, and lithography scale down the characteristic length-scale to nano meters. This poses tight constraints on the optics finishing tolerances, which is often difficult to characterize. Indeed, even a tiny surface defect degrades the reflectivity and spatial projection of such optics. In this study, we demonstrate experimentally that a Hartmann wavefront sensor…
▽ More
Short-wavelength imaging, spectroscopy, and lithography scale down the characteristic length-scale to nano meters. This poses tight constraints on the optics finishing tolerances, which is often difficult to characterize. Indeed, even a tiny surface defect degrades the reflectivity and spatial projection of such optics. In this study, we demonstrate experimentally that a Hartmann wavefront sensor for extreme ultraviolet (XUV) wavelengths is an effective non-contact analytical method for inspecting the surface of multilayer optics. The experiment was carried out in a tabletop laboratory using a high-order harmonic generation as an XUV source. The wavefront sensor was used to measure the wavefront errors after the reflection of the XUV beam on a spherical Ru/B4C multilayer mirror, scanning a large surface of approximately 40 mm in diameter. The results showed that the technique detects the aberrations in the nanometer range.
△ Less
Submitted 22 June, 2018;
originally announced June 2018.
-
Prototy** of petalets for the Phase-II Upgrade of the silicon strip tracking detector of the ATLAS Experiment
Authors:
S. Kuehn,
V. Benítez,
J. Fernández-Tejero,
C. Fleta,
M. Lozano,
M. Ullán,
H. Lacker,
L. Rehnisch,
D. Sperlich,
D. Ariza,
I. Bloch,
S. Díez,
I. Gregor,
J. Keller,
K. Lohwasser,
L. Poley,
V. Prahl,
N. Zakharchuk,
M. Hauser,
K. Jakobs,
K. Mahboubi,
R. Mori,
U. Parzefall,
J. Bernabéu,
C. Lacasta
, et al. (9 additional authors not shown)
Abstract:
In the high luminosity era of the Large Hadron Collider, the HL-LHC, the instantaneous luminosity is expected to reach unprecedented values, resulting in about 200 proton-proton interactions in a typical bunch crossing. To cope with the resultant increase in occupancy, bandwidth and radiation damage, the ATLAS Inner Detector will be replaced by an all-silicon system, the Inner Tracker (ITk). The I…
▽ More
In the high luminosity era of the Large Hadron Collider, the HL-LHC, the instantaneous luminosity is expected to reach unprecedented values, resulting in about 200 proton-proton interactions in a typical bunch crossing. To cope with the resultant increase in occupancy, bandwidth and radiation damage, the ATLAS Inner Detector will be replaced by an all-silicon system, the Inner Tracker (ITk). The ITk consists of a silicon pixel and a strip detector and exploits the concept of modularity. Prototy** and testing of various strip detector components has been carried out. This paper presents the developments and results obtained with reduced-size structures equivalent to those foreseen to be used in the forward region of the silicon strip detector. Referred to as petalets, these structures are built around a composite sandwich with embedded cooling pipes and electrical tapes for routing the signals and power. Detector modules built using electronic flex boards and silicon strip sensors are glued on both the front and back side surfaces of the carbon structure. Details are given on the assembly, testing and evaluation of several petalets. Measurement results of both mechanical and electrical quantities are shown. Moreover, an outlook is given for improved prototy** plans for large structures.
△ Less
Submitted 5 November, 2017;
originally announced November 2017.
-
Ultra Thin 3D Silicon Detector for Plasma Diagnostics at the ITER Tokamak
Authors:
F. Garcia,
G. Pellegrini,
M. Lozano,
J. P. Balbuena,
C. Fleta,
C. Guardiola,
D. Quirion
Abstract:
An ultra thin silicon detector called U3DTHIN has been designed and built for neutral particle analyzers (NPA) and thermal neutron detection. The main purpose of this detector is to provide a state-of-the-art solution for detector system of NPAs for the ITER experimental reactor and to be used in combination with a Boron conversion layer for the detection of thermal neutrons. Currently the NPAs…
▽ More
An ultra thin silicon detector called U3DTHIN has been designed and built for neutral particle analyzers (NPA) and thermal neutron detection. The main purpose of this detector is to provide a state-of-the-art solution for detector system of NPAs for the ITER experimental reactor and to be used in combination with a Boron conversion layer for the detection of thermal neutrons. Currently the NPAs are using very thin scintillator - photomultiplier tube, and their main drawbacks are poor energy resolution, intrinsic scintillation nonlinearity, relative low count rate capability and finally poor signal to background discrimination power for the low energy channels. The proposed U3DTHIN detector is based on very thin sensitive substrate which will provide nearly 100% detection efficiency for ions and at the same time very low sensitivity for the neutron and gamma radiation. To achieve a very fast charge collection of the carriers generated by the ions detection a 3D electrode structure[5] has been introduced in the sensitive volume of the detector. One of the most innovative features of these detectors has been the optimal combination of the thin entrance window and the sensitive substrate thickness, to accommodate very large energy dynamic range of the detected ions. An entrance window with a thickness of tens of nanometers together with a sensitive substrate thickness varying from less than 5 microns, to detect the lowest energetic ions to 20 microns for the height ones has been selected after simulations with GEANT4. To increase the signal to background ratio the detector will operate in spectroscopy regime allowing to perform pulse-height analysis. The technology used to fabricate these 3D ultra thin detectors developed at Centro Nacional de Microelectronica in Barcelona and the first signals from an alpha source (241Am) will presented
△ Less
Submitted 16 December, 2016;
originally announced January 2017.
-
Relativistic electron beams driven by kHz single-cycle light pulses
Authors:
D. Guénot,
D. Gustas,
A. Vernier,
B. Beaurepaire,
F. Böhle,
M. Bocoum,
M. Lozano,
A. Jullien,
R. Lopez-Martens,
A. Lifschitz,
J. Faure
Abstract:
Laser-plasma acceleration is an emerging technique for accelerating electrons to high energies over very short distances. The accelerated electron bunches have femtosecond duration, making them particularly relevant for applications such as ultrafast imaging or femtosecond X-ray generation. Current laser-plasma accelerators are typically driven by Joule-class laser systems that have two main drawb…
▽ More
Laser-plasma acceleration is an emerging technique for accelerating electrons to high energies over very short distances. The accelerated electron bunches have femtosecond duration, making them particularly relevant for applications such as ultrafast imaging or femtosecond X-ray generation. Current laser-plasma accelerators are typically driven by Joule-class laser systems that have two main drawbacks: their relatively large scale and their low repetition-rate, with a few shots per second at best. The accelerated electron beams have energies ranging from 100 MeV to multi-GeV, however a MeV electron source would be more suited to many societal and scientific applications. Here, we demonstrate a compact and reliable laser-plasma accelerator producing high-quality few-MeV electron beams at kilohertz repetition rate. This breakthrough was made possible by using near-single-cycle light pulses, which lowered the required laser energy for driving the accelerator by three orders of magnitude, thus enabling high repetition-rate operation and dramatic downsizing of the laser system. The measured electron bunches are collimated, with an energy distribution that peaks at 5 MeV and contains up to 1 pC of charge. Numerical simulations reproduce all experimental features and indicate that the electron bunches are only $\sim 1$ fs long. We anticipate that the advent of these kHz femtosecond relativistic electron sources will pave the way to wide-impact applications, such as ultrafast electron diffraction in materials with an unprecedented sub-10 fs resolution.
△ Less
Submitted 2 December, 2016; v1 submitted 29 November, 2016;
originally announced November 2016.
-
Spectral-phase interferometry for direct electric-field reconstruction applied to seeded extreme-ultraviolet free-electron lasers
Authors:
Benoît Mahieu,
David Gauthier,
Giovanni De Ninno,
Hugo Dacasa,
Magali Lozano,
Jean-Philippe Rousseau,
Philippe Zeitoun,
David Garzella,
Hamed Merdji
Abstract:
We present a setup for complete characterization of femtosecond pulses generated by seeded free-electron lasers (FEL's) in the extreme-ultraviolet spectral region. Two delayed and spectrally shifted replicas are produced and used for spectral phase interferometry for direct electric field reconstruction (SPIDER). We show that it can be achieved by a simple arrangement of the seed laser. Temporal s…
▽ More
We present a setup for complete characterization of femtosecond pulses generated by seeded free-electron lasers (FEL's) in the extreme-ultraviolet spectral region. Two delayed and spectrally shifted replicas are produced and used for spectral phase interferometry for direct electric field reconstruction (SPIDER). We show that it can be achieved by a simple arrangement of the seed laser. Temporal shape and phase obtained in FEL simulations are well retrieved by the SPIDER reconstruction, allowing to foresee the implementation of this diagnostic on existing and future sources. This will be a significant step towards an experimental investigation and control of FEL spectral phase.
△ Less
Submitted 12 February, 2015;
originally announced February 2015.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
First investigation of a novel 2D position-sensitive semiconductor detector concept
Authors:
D. Bassignana,
M. Fernandez,
R. Jaramillo,
M. Lozano,
F. J. Munoz,
G. Pellegrini,
D. Quirion,
I. Vila
Abstract:
This paper presents a first study of the performance of a novel 2D position-sensitive microstrip detector, where the resistive charge division method was implemented by replacing the metallic electrodes with resistive electrodes made of polycrystalline silicon. A characterization of two proof-of-concept prototypes with different values of the electrode resistivity was carried out using a pulsed Ne…
▽ More
This paper presents a first study of the performance of a novel 2D position-sensitive microstrip detector, where the resistive charge division method was implemented by replacing the metallic electrodes with resistive electrodes made of polycrystalline silicon. A characterization of two proof-of-concept prototypes with different values of the electrode resistivity was carried out using a pulsed Near Infra-Red laser. The experimental data were compared with the electrical simulation of the sensor equivalent circuit coupled to simple electronics readout circuits. The good agreement between experimental and simulation results establishes the soundness of resistive charge division method in silicon microstrip sensors and validates the developed simulation as a tool for the optimization of future sensor prototypes. Spatial resolution in the strip length direction depends on the ionizing event position. The average value obtained from the protype analysis is close to 1.2% of the strip length for a 6 MIP signal.
△ Less
Submitted 3 February, 2012; v1 submitted 27 June, 2011;
originally announced June 2011.
-
Charged Particle Tracking with the Timepix ASIC
Authors:
Kazuyoshi Akiba,
Marina Artuso,
Ryan Badman,
Alessandra Borgia,
Richard Bates,
Florian Bayer,
Martin van Beuzekom,
Jan Buytaert,
Enric Cabruja,
Michael Campbell,
Paula Collins,
Michael Crossley,
Raphael Dumps,
Lars Eklund,
Daniel Esperante,
Celeste Fleta,
Abraham Gallas,
Miriam Gandelman,
Justin Garofoli,
Marco Gersabeck,
Vladimir V. Gligorov,
Hamish Gordon,
Erik H. M. Heijne,
Veerle Heijne,
Daniel Hynds
, et al. (17 additional authors not shown)
Abstract:
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was u…
▽ More
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was used to evaluate in detail the performance of two Timepix hybrid pixel assemblies; a standard planar 300 micron thick sensor, and 285 micron thick double sided 3D sensor. This paper describes a detailed charge calibration study of the pixel devices, which allows the true charge to be extracted, and reports on measurements of the charge collection characteristics and Landau distributions. The planar sensor achieved a best resolution of 4.0 micron for angled tracks, and resolutions of between 4.4 and 11 micron for perpendicular tracks, depending on the applied bias voltage. The double sided 3D sensor, which has significantly less charge sharing, was found to have an optimal resolution of 9.0 micron for angled tracks, and a resolution of 16.0 micron for perpendicular tracks. Based on these studies it is concluded that the Timepix ASIC shows an excellent performance when used as a device for charged particle tracking.
△ Less
Submitted 14 June, 2011; v1 submitted 14 March, 2011;
originally announced March 2011.
-
Test Beam Results of 3D Silicon Pixel Sensors for the ATLAS upgrade
Authors:
ATLAS 3D Collaboration,
P. Grenier,
G. Alimonti,
M. Barbero,
R. Bates,
E. Bolle,
M. Borri,
M. Boscardin,
C. Buttar,
M. Capua,
M. Cavalli-Sforza,
M. Cobal,
A. Cristofoli,
G-F. Dalla Betta,
G. Darbo,
C. Da Vià,
E. Devetak,
B. DeWilde,
B. Di Girolamo,
D. Dobos,
K. Einsweiler,
D. Esseni,
S. Fazio,
C. Fleta,
J. Freestone
, et al. (68 additional authors not shown)
Abstract:
Results on beam tests of 3D silicon pixel sensors aimed at the ATLAS Insertable-B-Layer and High Luminosity LHC (HL-LHC)) upgrades are presented. Measurements include charge collection, tracking efficiency and charge sharing between pixel cells, as a function of track incident angle, and were performed with and without a 1.6 T magnetic field oriented as the ATLAS Inner Detector solenoid field. Sen…
▽ More
Results on beam tests of 3D silicon pixel sensors aimed at the ATLAS Insertable-B-Layer and High Luminosity LHC (HL-LHC)) upgrades are presented. Measurements include charge collection, tracking efficiency and charge sharing between pixel cells, as a function of track incident angle, and were performed with and without a 1.6 T magnetic field oriented as the ATLAS Inner Detector solenoid field. Sensors were bump bonded to the front-end chip currently used in the ATLAS pixel detector. Full 3D sensors, with electrodes penetrating through the entire wafer thickness and active edge, and double-sided 3D sensors with partially overlap** bias and read-out electrodes were tested and showed comparable performance.
△ Less
Submitted 21 January, 2011;
originally announced January 2011.
-
Alignment of Silicon tracking systems R&D on Semitransparent Microstrip Sensors
Authors:
Jordi Duarte,
Marcos Fernandez,
Javier Gonzalez,
Richard Jaramillo,
Amparo Lopez,
Celso Martinez,
David Moya,
Alberto Ruiz,
I. Vila,
D. Bassignana,
E. Cabruja,
M. Lozano,
G. Pellegrini
Abstract:
We summarize the R&D activities on a novel semitransparent microstrip sensor to be used on laser-based alignment systems for silicon trackers. The new sensor is used both for particle tracking and laser detection. The aim of this research line is to increase the optical transmittance (T) of Silicon microstrips detectors to infrared light, introducing minor modifications to the sensor design stil…
▽ More
We summarize the R&D activities on a novel semitransparent microstrip sensor to be used on laser-based alignment systems for silicon trackers. The new sensor is used both for particle tracking and laser detection. The aim of this research line is to increase the optical transmittance (T) of Silicon microstrips detectors to infrared light, introducing minor modifications to the sensor design still suitable for its industrial production. The optical simulations used in the sensor design have been experimentally validated against several patterned material samples. This activities have been carried out in the context of SiLC collaboration for the next International Linear Collider.
△ Less
Submitted 9 January, 2009;
originally announced January 2009.
-
Science with the new generation high energy gamma- ray experiments
Authors:
M. Alvarez,
D. D'Armiento,
G. Agnetta,
A. Alberdi,
A. Antonelli,
A. Argan,
P. Assis,
E. A. Baltz,
C. Bambi,
G. Barbiellini,
H. Bartko,
M. Basset,
D. Bastieri,
P. Belli,
G. Benford,
L. Bergstrom,
R. Bernabei,
G. Bertone,
A. Biland,
B. Biondo,
F. Bocchino,
E. Branchini,
M. Brigida,
T. Bringmann,
P. Brogueira
, et al. (175 additional authors not shown)
Abstract:
This Conference is the fifth of a series of Workshops on High Energy Gamma- ray Experiments, following the Conferences held in Perugia 2003, Bari 2004, Cividale del Friuli 2005, Elba Island 2006. This year the focus was on the use of gamma-ray to study the Dark Matter component of the Universe, the origin and propagation of Cosmic Rays, Extra Large Spatial Dimensions and Tests of Lorentz Invaria…
▽ More
This Conference is the fifth of a series of Workshops on High Energy Gamma- ray Experiments, following the Conferences held in Perugia 2003, Bari 2004, Cividale del Friuli 2005, Elba Island 2006. This year the focus was on the use of gamma-ray to study the Dark Matter component of the Universe, the origin and propagation of Cosmic Rays, Extra Large Spatial Dimensions and Tests of Lorentz Invariance.
△ Less
Submitted 4 December, 2007;
originally announced December 2007.