-
JulianA.jl -- A Julia package for radiotherapy
Authors:
Renato Bellotti,
Antony J. Lomax,
Andreas Adelmann,
Jan Hrbacek
Abstract:
The importance of computers is continually increasing in radiotherapy. Efficient algorithms, implementations and the ability to leverage advancements in computer science are crucial to improve cancer care even further and deliver the best treatment to each patient. Yet, the software landscape for radiotherapy is fragmented into proprietary systems that do not share a common interface. Further, the…
▽ More
The importance of computers is continually increasing in radiotherapy. Efficient algorithms, implementations and the ability to leverage advancements in computer science are crucial to improve cancer care even further and deliver the best treatment to each patient. Yet, the software landscape for radiotherapy is fragmented into proprietary systems that do not share a common interface. Further, the radiotherapy community does not have access to the vast possibilities offered by modern programming languages and their ecosystem of libraries yet.
We present JulianA.jl, a novel Julia package for radiotherapy. It aims to provide a modular and flexible foundation for the development and efficient implementation of algorithms and workflows for radiotherapy researchers and clinicians. JulianA.jl can be interfaced with any scriptable treatment planning system, be it commercial, open source or in-house developed. This article highlights our design choices and showcases the package's simplicity and powerful automatic treatment planning capabilities.
△ Less
Submitted 4 July, 2024;
originally announced July 2024.
-
A Unified Generation-Registration Framework for Improved MR-based CT Synthesis in Proton Therapy
Authors:
Xia Li,
Renato Bellotti,
Barbara Bachtiary,
Jan Hrbacek,
Damien C. Weber,
Antony J. Lomax,
Joachim M. Buhmann,
Ye Zhang
Abstract:
Background: In MR-guided proton therapy planning, aligning MR and CT images is key for MR-based CT synthesis, especially in mobile regions like the head-and-neck. Misalignments here can lead to less accurate synthetic CT (sCT) images, impacting treatment precision. Purpose: This study introduces a novel network that cohesively unifies image generation and registration processes to enhance the qual…
▽ More
Background: In MR-guided proton therapy planning, aligning MR and CT images is key for MR-based CT synthesis, especially in mobile regions like the head-and-neck. Misalignments here can lead to less accurate synthetic CT (sCT) images, impacting treatment precision. Purpose: This study introduces a novel network that cohesively unifies image generation and registration processes to enhance the quality and anatomical fidelity of sCTs derived from better-aligned MR images. Methods: The approach synergizes a generation network (G) with a deformable registration network (R), optimizing them jointly in MR-to-CT synthesis. This goal is achieved by alternately minimizing the discrepancies between the generated/registered CT images and their corresponding reference CT counterparts. The generation network employs a UNet architecture, while the registration network leverages an implicit neural representation of the Deformable Vector Fields (DVFs). We validated this method on a dataset comprising 60 Head-and-Neck patients, reserving 12 cases for holdout testing. Results: Compared to the baseline Pix2Pix method with MAE 124.95\pm 30.74 HU, the proposed technique demonstrated 80.98\pm 7.55 HU. The unified translation-registration network produced sharper and more anatomically congruent outputs, showing superior efficacy in converting MR images to sCTs. Additionally, from a dosimetric perspective, the plan recalculated on the resulting sCTs resulted in a remarkably reduced discrepancy to the reference proton plans. Conclusions: This study conclusively demonstrates that a holistic MR-based CT synthesis approach, integrating both image-to-image translation and deformable registration, significantly improves the precision and quality of sCT generation, particularly for the challenging body area with varied anatomic changes between corresponding MR and CT.
△ Less
Submitted 23 January, 2024;
originally announced January 2024.
-
JulianA: An automatic treatment planning platform for intensity-modulated proton therapy and its application to intra- and extracerebral neoplasms
Authors:
Renato Bellotti,
Jonas Willmann,
Antony J. Lomax,
Andreas Adelmann,
Damien C. Weber,
Jan Hrbacek
Abstract:
Creating high quality treatment plans is crucial for a successful radiotherapy treatment. However, it demands substantial effort and special training for dosimetrists. Existing automated treatment planning systems typically require either an explicit prioritization of planning objectives, human-assigned objective weights, large amounts of historic plans to train an artificial intelligence or long…
▽ More
Creating high quality treatment plans is crucial for a successful radiotherapy treatment. However, it demands substantial effort and special training for dosimetrists. Existing automated treatment planning systems typically require either an explicit prioritization of planning objectives, human-assigned objective weights, large amounts of historic plans to train an artificial intelligence or long planning times. Many of the existing auto-planning tools are difficult to extend to new planning goals.
A new spot weight optimisation algorithm, called JulianA, was developed. The algorithm minimises a scalar loss function that is built only based on the prescribed dose to the tumour and organs at risk (OARs), but does not rely on historic plans. The objective weights in the loss function have default values that do not need to be changed for the patients in our dataset. The system is a versatile tool for researchers and clinicians without specialised programming skills. Extending it is as easy as adding an additional term to the loss function. JulianA was validated on a dataset of 19 patients with intra- and extracerebral neoplasms within the cranial region that had been treated at our institute. For each patient, a reference plan which was delivered to the cancer patient, was exported from our treatment database. Then JulianA created the auto plan using the same beam arrangement. The reference and auto plans were given to a blinded independent reviewer who assessed the acceptability of each plan, ranked the plans and assigned the human-/machine-made labels.
The auto plans were considered acceptable in 16 out of 19 patients and at least as good as the reference plan for 11 patients. Whether a plan was crafted by a dosimetrist or JulianA was only recognised for 9 cases. The median time for the spot weight optimisation is approx. 2 min (range: 0.5 min - 7 min).
△ Less
Submitted 15 December, 2023; v1 submitted 17 May, 2023;
originally announced May 2023.
-
Feasibility of the J-PET to monitor range of therapeutic proton beams
Authors:
Jakub Baran,
Damian Borys,
Karol Brzeziński,
Jan Gajewski,
Michał Silarski,
Neha Chug,
Aurélien Coussat,
Eryk Czerwiński,
Meysam Dadgar,
Kamil Dulski,
Kavya V. Eliyan,
Aleksander Gajos Krzysztof Kacprzak,
Łukasz Kapłon,
Konrad Klimaszewski,
Paweł Konieczka,
Renata Kopeć,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Deepak Kumar,
Antony J. Lomax,
Keegan McNamara,
Szymon Niedźwiecki,
Paweł Olko,
Dominik Panek
, et al. (18 additional authors not shown)
Abstract:
Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated prot…
▽ More
Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.
△ Less
Submitted 28 February, 2023;
originally announced February 2023.
-
Universal and dynamic ridge filter for pencil beam scanning particle therapy: novel concept for ultra-fast treatment delivery
Authors:
Vivek Maradia,
Isabella Colizzi,
David Meer,
Damien Charles Weber,
Antony John Lomax,
Oxana Actis,
Serena Psoroulas
Abstract:
Purpose In PBS particle therapy, short treatment delivery time is paramount for the efficient treatment of moving targets with motion mitigation techniques (such as breath-hold, rescanning, and gating). Energy and spot position change time are limiting factors in reducing treatment time. In this study, we designed a universal and dynamic energy modulator (ridge filter, RF) to broaden the Bragg pea…
▽ More
Purpose In PBS particle therapy, short treatment delivery time is paramount for the efficient treatment of moving targets with motion mitigation techniques (such as breath-hold, rescanning, and gating). Energy and spot position change time are limiting factors in reducing treatment time. In this study, we designed a universal and dynamic energy modulator (ridge filter, RF) to broaden the Bragg peak, to reduce the number of energies and spots required to cover the target volume, thus lowering the treatment time. Methods Our RF unit comprises two identical RFs placed just before the isocenter. Both RFs move relative to each other, changing the Bragg peaks characteristics dynamically. We simulated different Bragg peak shapes with the RF in TOPAS and validated them experimentally. We then delivered single-field plans with 1Gy/fraction to different geometrical targets in water, to measure the dose delivery time using the RF and compare it with the clinical settings. Results Aligning the RFs in different positions produces different broadening in the Bragg peak; we achieved a maximum broadening of 2 cm. With RF we reduced the number of energies in a field by more than 60%, and the dose delivery time by 50%, for all geometrical targets investigated, without compromising the dose distribution transverse and distal fall-off. Conclusions Our novel universal and dynamic RF allows for the adaptation of the Bragg peak broadening for a spot and/or energy layer based on the requirement of dose sha** in the target volume. It significantly reduces the number of energy layers and spots to cover the target volume, and thus the treatment time. This RF design is ideal for ultra-fast treatment delivery within a single breath-hold (5-10 sec), efficient delivery of motion mitigation techniques, and small animal irradiation with ultra-high dose rates (FLASH).
△ Less
Submitted 13 August, 2022;
originally announced August 2022.
-
Commissioning of a clinical pencil beam scanning proton therapy unit for ultrahigh dose rates (FLASH)
Authors:
K. P. Nesteruk,
M. Togno,
M. Grossmann,
A. J. Lomax,
D. C. Weber,
J. M. Schippers,
S. Safai,
D. Meer,
S. Psoroulas
Abstract:
Purpose: The purpose of this work was to provide a flexible platform for FLASH research with protons by adapting a former clinical pencil beam scanning gantry to irradiations with ultrahigh dose rates.
Methods: PSI Gantry 1 treated patients until December 2018. We optimized the beamline parameters to transport the 250 MeV beam extracted from the PSI COMET accelerator to the treatment room, maxim…
▽ More
Purpose: The purpose of this work was to provide a flexible platform for FLASH research with protons by adapting a former clinical pencil beam scanning gantry to irradiations with ultrahigh dose rates.
Methods: PSI Gantry 1 treated patients until December 2018. We optimized the beamline parameters to transport the 250 MeV beam extracted from the PSI COMET accelerator to the treatment room, maximizing the transmission of beam intensity to the sample. We characterized a dose monitor on the gantry to ensure good control of the dose, delivered in spot-scanning mode. We characterized the beam for different dose rates and field sizes for transmission irradiations. We explored scanning possibilities in order to enable conformal irradiations or transmission irradiations of large targets (with transverse scanning). Results: We achieved a transmission of 86 % from the cyclotron to the treatment room. We reached a peak dose rate of 9000 Gy/s at 3 mm water equivalent depth, along the central axis of a single pencil beam. Field sizes of up to 5x5 mm$^{2}$ were achieved for single spot FLASH irradiations. Fast transverse scanning allowed to cover a field of 16x1.2 cm$^{2}$. With the use of a nozzle-mounted range shifter we are able to span depths in water ranging from 19.6 to 37.9 cm. Various dose levels were delivered with a precision within less than 1 %. Conclusions: We have realized a proton FLASH irradiation setup able to investigate continuously a wide dose rate spectrum, from 1 to 9000 Gy/s in a single spot irradiation as well as in the pencil beam scanning mode. As such, we have developed a versatile test bench for FLASH research.
△ Less
Submitted 5 January, 2021;
originally announced January 2021.