Real-time Adaptive and Localized Spatiotemporal Clutter Filtering for Ultrasound Small Vessel Imaging
Authors:
Chengwu Huang,
U-Wai Lok,
**gke Zhang,
Hui Liu,
Shigao Chen
Abstract:
Effective clutter filtering is crucial in suppressing tissue clutter and extracting blood flow signal in Doppler ultrasound. Recent advances in eigen-based clutter filtering techniques have enabled ultrasound imaging of microvasculature without the need for contrast agents. However, simultaneously achieving fully adaptive, highly sensitive and real-time implementation of such eigen-based filtering…
▽ More
Effective clutter filtering is crucial in suppressing tissue clutter and extracting blood flow signal in Doppler ultrasound. Recent advances in eigen-based clutter filtering techniques have enabled ultrasound imaging of microvasculature without the need for contrast agents. However, simultaneously achieving fully adaptive, highly sensitive and real-time implementation of such eigen-based filtering techniques in clinical scanning scenarios for broad translation remains challenging. To address this, here we propose a fast spatiotemporal clutter filtering technique based on eigenvalue decomposition (EVD) and a novel localized data processing framework for robust and high-definition ultrasound imaging of blood flow. Unlike the existing local clutter filter that hard splits the ultrasound data into small blocks, our approach applies a series of 2D spatial Gaussian windows to the original data to generate local data subsets. This approach improves performance of flow detection while effectively avoiding undesired grid artifacts with dramatically reduced number of subsets required in local EVD filtering to shorten computation time. By leveraging the computational power of Graphics Processing Units (GPUs), we demonstrate the real-time implementation capability of the proposed approach. We also introduce and systematically evaluate several adaptive and automatic eigenvalue thresholding methods tailored for EVD-based filtering to facilitate optimization of blood flow imaging for either global or localized processing. The feasibility of the proposed clutter filtering technique is validated by experimental results from phantom and different in vivo studies, revealing robust clinical application potential. A tradeoff between improved performance and computational cost associated with the packet size and subset number in local processing is also investigated.
△ Less
Submitted 17 May, 2024;
originally announced May 2024.
Super-Resolution Ultrasound Localization Microscopy Based on a High Frame-rate Clinical Ultrasound Scanner: An In-human Feasibility Study
Authors:
Chengwu Huang,
Wei Zhang,
** Gong,
U-Wai Lok,
Shanshan Tang,
Tinghui Yin,
Xirui Zhang,
Lei Zhu,
Maodong Sang,
Pengfei Song,
Rongqin Zheng,
Shigao Chen
Abstract:
Non-invasive detection of microvascular alterations in deep tissues in vivo provides critical information for clinical diagnosis and evaluation of a broad-spectrum of pathologies. Recently, the emergence of super-resolution ultrasound localization microscopy (ULM) offers new possibilities for clinical imaging of microvasculature at capillary level. Currently, the clinical utility of ULM on clinica…
▽ More
Non-invasive detection of microvascular alterations in deep tissues in vivo provides critical information for clinical diagnosis and evaluation of a broad-spectrum of pathologies. Recently, the emergence of super-resolution ultrasound localization microscopy (ULM) offers new possibilities for clinical imaging of microvasculature at capillary level. Currently, the clinical utility of ULM on clinical ultrasound scanners is hindered by the technical limitations, such as long data acquisition time, and compromised tracking performance associated with low imaging frame-rate. Here we present an in-human ULM on a high frame-rate (HFR) clinical ultrasound scanner to achieve super-resolution microvessel imaging using a short acquisition time (<10s). Ultrasound MB data were acquired from different human tissues, (liver, kidney, pancreatic, and breast tumor) using an HFR clinical scanner. By leveraging the HFR and advanced processing techniques including sub-pixel motion registration, MB signal separation, and Kalman filter-based tracking, MBs can be robustly localized and tracked for successful ULM under the circumstances of relatively high MB concentration and limited data acquisition time in humans. Subtle morphological and hemodynamic information were demonstrated on data acquired with single breath-hold and free-hand scanning. Compared with contrast-enhanced power Doppler generated based on the same MB dataset, ULM showed a 5.7-fold resolution improvement in a vessel, and provided a wide-range flow speed measurement that is Doppler angle-independent. This study demonstrated the feasibility of ultrafast in-human ULM in various human tissues based on a clinical scanner that supports HFR imaging, and showed a great potential for the implementation of super-resolution ultrasound microvessel imaging in a myriad of clinical applications involving microvascular abnormalities and pathologies.
△ Less
Submitted 28 September, 2020;
originally announced September 2020.