-
Technical Design Report for the LUXE Experiment
Authors:
H. Abramowicz,
M. Almanza Soto,
M. Altarelli,
R. Aßmann,
A. Athanassiadis,
G. Avoni,
T. Behnke,
M. Benettoni,
Y. Benhammou,
J. Bhatt,
T. Blackburn,
C. Blanch,
S. Bonaldo,
S. Boogert,
O. Borysov,
M. Borysova,
V. Boudry,
D. Breton,
R. Brinkmann,
M. Bruschi,
F. Burkart,
K. Büßer,
N. Cavanagh,
F. Dal Corso,
W. Decking
, et al. (109 additional authors not shown)
Abstract:
This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger fiel…
▽ More
This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger field and beyond. The further implications for the search of physics beyond the Standard Model are also discussed.
△ Less
Submitted 2 August, 2023; v1 submitted 1 August, 2023;
originally announced August 2023.
-
Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
O. Borysov,
M. Borysova,
I. Bozovic- Jelisavcic,
W. Daniluk,
D. Dannheim,
M. Demichev,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempelb,
H. Henschel,
M. Idzik,
A. Ignatenkoc,
A. Ishikawa,
A. Joffe,
G. Kacarevic,
S. Kananov,
O. Karachebanb
, et al. (29 additional authors not shown)
Abstract:
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY wi…
▽ More
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1-5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Moli`ere radius at 5 GeV was determined to be (8.1 +/- 0.1 (stat) +/- 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 +/- 0.1) mm. The dependence of the effective Moli`ere radius on the electron energy in the range 1-5 GeV was also studied. Good agreement was obtained between data and MC simulation.
△ Less
Submitted 25 October, 2019; v1 submitted 29 December, 2018;
originally announced December 2018.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Borysova,
I. Bozovic-Jelisavcic,
G. Chelkov,
W. Daniluk,
D. Dannheim,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempel,
H. Henschel,
M. Idzik,
A. Ignatenko,
A. Ishikawa,
S. Kananov,
O. Karacheban,
W. Klempt
, et al. (35 additional authors not shown)
Abstract:
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined t…
▽ More
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.
△ Less
Submitted 12 March, 2018; v1 submitted 10 May, 2017;
originally announced May 2017.
-
Trap** in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
Authors:
W. Adam,
T. Bergauer,
M. Dragicevic,
M. Friedl,
R. Fruehwirth,
M. Hoch,
J. Hrubec,
M. Krammer,
W. Treberspurg,
W. Waltenberger,
S. Alderweireldt,
W. Beaumont,
X. Janssen,
S. Luyckx,
P. Van Mechelen,
N. Van Remortel,
A. Van Spilbeeck,
P. Barria,
C. Caillol,
B. Clerbaux,
G. De Lentdecker,
D. Dobur,
L. Favart,
A. Grebenyuk,
Th. Lenzi
, et al. (663 additional authors not shown)
Abstract:
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi…
▽ More
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trap** rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trap** rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trap** rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
Investigation of a direction sensitive sapphire detector stack at the 5 GeV electron beam at DESY-II
Authors:
O. Karacheban,
K. Afanaciev,
M. Hempel,
H. Henschel,
W. Lange,
J. L. Leonard,
I. Levy,
W. Lohmann,
S. Schuwalow
Abstract:
Extremely radiation hard sensors are needed in particle physics experiments to instrument the region near the beam pipe. Examples are beam halo and beam loss monitors at the Large Hadron Collider, FLASH or XFEL. Currently artificial diamond sensors are widely used. In this paper single crystal sapphire sensors are considered as a promising alternative. Industrially grown sapphire wafers are availa…
▽ More
Extremely radiation hard sensors are needed in particle physics experiments to instrument the region near the beam pipe. Examples are beam halo and beam loss monitors at the Large Hadron Collider, FLASH or XFEL. Currently artificial diamond sensors are widely used. In this paper single crystal sapphire sensors are considered as a promising alternative. Industrially grown sapphire wafers are available in large sizes, are of low cost and, like diamond sensors, can be operated without cooling. Here we present results of an irradiation study done with sapphire sensors in a high intensity low energy electron beam. Then, a multichannel direction-sensitive sapphire detector stack is described. It comprises 8 sapphire plates of 1 cm^2 size and 525 micro m thickness, metallized on both sides, and apposed to form a stack. Each second metal layer is supplied with a bias voltage, and the layers in between are connected to charge-sensitive preamplifiers. The performance of the detector was studied in a 5 GeV electron beam. The charge collection efficiency measured as a function of the bias voltage rises with the voltage, reaching about 10 % at 950 V. The signal size obtained from electrons crossing the stack at this voltage is about 22000 e, where e is the unit charge.
The signal size is measured as a function of the hit position, showing variations of up to 20 % in the direction perpendicular to the beam and to the electric field. The measurement of the signal size as a function of the coordinate parallel to the electric field confirms the prediction that mainly electrons contribute to the signal. Also evidence for the presence of a polarisation field was observed.
△ Less
Submitted 15 July, 2015; v1 submitted 15 April, 2015;
originally announced April 2015.
-
ECFA Detector R&D Panel, Review Report
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
P. Bambade,
L. Bortko,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
A. Dragone,
L. Dumitru,
K. Elsener,
I. Emeliantchik,
E. Firu,
J. Fischer,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
G. Grzelak,
G. Haller,
H. Henschel
, et al. (46 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The in…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.
△ Less
Submitted 19 November, 2014; v1 submitted 18 November, 2014;
originally announced November 2014.
-
Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
D. Avila,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Bergholz,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
L. Dumitru,
K. Elsener,
V. Fadeyev,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
H. Henschel
, et al. (44 additional authors not shown)
Abstract:
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sens…
▽ More
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.
△ Less
Submitted 1 June, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Fast Beam Condition Monitor for CMS: performance and upgrade
Authors:
Jessica L. Leonard,
Alan Bell,
Piotr Burtowy,
Anne Dabrowski,
Maria Hempel,
Hans Henschel,
Wolfgang Lange,
Wolfgang Lohmann,
Nathaniel Odell,
Marek Penno,
Brian Pollack,
Dominik Przyborowski,
Vladimir Ryjov,
David Stickland,
Roberval Walsh,
Weronika Warzycha,
Agnieszka Zagozdzinska
Abstract:
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is b…
▽ More
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance of BCM1F during LHC run I, including results of the van der Meer scan and on-line luminosity monitoring done in 2012. In order to match the requirements due to higher luminosity and 25 ns bunch spacing, several changes to the system must be implemented during the upcoming shutdown, including upgraded electronics and precise gain monitoring. First results from Run II preparation are shown.
△ Less
Submitted 8 May, 2014;
originally announced May 2014.
-
Measurement of the Luminosity in the ZEUS Experiment at HERA II
Authors:
L. Adamczyk,
J. Andruszkow,
T. Bold,
P. Borzemski,
C. Buettner,
A. Caldwell,
J. Chwastowski,
W. Daniluk,
V. Drugakov,
A. Eskreys,
J. Figiel,
A. Galas,
M. Gil,
M. Helbich,
F. Januschek,
P. Jurkiewicz,
D. Kisielewska,
U. Klein,
A. Kotarba,
W. Lohmann,
Y. Ning,
K. Oliwa,
K. Olkiewicz,
S. Paganis,
J. Pieron
, et al. (12 additional authors not shown)
Abstract:
The luminosity in the ZEUS detector was measured using photons from electron bremsstrahlung. In 2001 the HERA collider was upgraded for operation at higher luminosity. At the same time the luminosity-measuring system of the ZEUS experiment was modified to tackle the expected higher photon rate and synchrotron radiation. The existing lead-scintillator calorimeter was equipped with radiation hard sc…
▽ More
The luminosity in the ZEUS detector was measured using photons from electron bremsstrahlung. In 2001 the HERA collider was upgraded for operation at higher luminosity. At the same time the luminosity-measuring system of the ZEUS experiment was modified to tackle the expected higher photon rate and synchrotron radiation. The existing lead-scintillator calorimeter was equipped with radiation hard scintillator tiles and shielded against synchrotron radiation. In addition, a magnetic spectrometer was installed to measure the luminosity independently using photons converted in the beam-pipe exit window. The redundancy provided a reliable and robust luminosity determination with a systematic uncertainty of 1.7%. The experimental setup, the techniques used for luminosity determination and the estimate of the systematic uncertainty are reported.
△ Less
Submitted 13 June, 2013; v1 submitted 6 June, 2013;
originally announced June 2013.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
Luminometer for the future International Linear Collider - simulation and beam test results
Authors:
J. A. Aguilar,
S. Kulis,
W. Wierba,
L. Zawiejski,
E. Kielar,
M. Chrzaszcz,
O. Novgorodova,
H. Henschel,
W. Lohmann,
S. Schuwalow,
K. Afanaciev,
A. Ignatenko,
S. Kollowa,
I. Levy,
M. Idzik,
J. Kotula,
A. Moszczynski,
K. Oliwa,
B. Pawlik,
W. Daniluk
Abstract:
LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the order of 10e-3, or 10e-4 when running in GigaZ mode. Luminosity will be determined by counting Bhabha scattering events coincident in the two calorimeter module…
▽ More
LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the order of 10e-3, or 10e-4 when running in GigaZ mode. Luminosity will be determined by counting Bhabha scattering events coincident in the two calorimeter modules placed symmetrically on opposite sides of the interaction point. To meet these goals, the energy resolution of the calorimeter must be better than 1.5% at high energies. LumiCal has been designed as a 30-layer sampling calorimeter with tungsten as the passive material and silicon as the active material. Monte Carlo simulation using the Geant4 software framework has been used to identify design elements which adversely impact energy resolution and correct for them without loss of statistics. BeamCal, covering polar angles smaller than LumiCal, will serve for beam tuning, luminosity optimisation and high energy electron detection. Secondly, prototypes of the sensors and electronics for both detectors have been evaluated during beam tests, the results of which are also presented here.
△ Less
Submitted 22 November, 2011;
originally announced November 2011.
-
Performance of the Fast Beam Conditions Monitor BCM1F of CMS in the first running periods of LHC
Authors:
R. S. Schmidt,
A. J. Bell,
E. Castro,
R. Hall-Wilton,
M. Hempel,
W. Lange,
W. Lohmann,
S. Müller,
V. Ryjov,
D. Stickland,
R. Walsh
Abstract:
The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different time scales. They detect adverse beam conditions, facilitate beam tuning close to CMS, and measure the doses accumulated in different detector components. Data…
▽ More
The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different time scales. They detect adverse beam conditions, facilitate beam tuning close to CMS, and measure the doses accumulated in different detector components. Data are taken and analysed independently of the CMS data acquisition, displayed in the control room, and provide inputs to the trigger system and the LHC operators. In case of beam conditions dangerous to the CMS detector, a beam abort is induced.
The Fast Beam Conditions Monitor, BCM1F, is a flux counter close to the beam pipe inside the tracker volume. It uses single-crystal CVD diamond sensors, radiation-hard FE electronics, and optical signal transmission to measure the beam halo as well as collision products bunch by bunch. The system has been operational during the initiatory runs of LHC in September 2008. It works reliably since the restart in 2009 and is invaluable to CMS for everyday LHC operation. A characterisation of the system on the basis of data collected during LHC operation is presented.
△ Less
Submitted 16 December, 2010;
originally announced December 2010.
-
Summary of the Linear Collider Testbeam Workshop 2009 - LCTW09
Authors:
V. Boudry,
G. Fisk,
R. E. Frey,
F. Gaede,
C. Hast,
J. Hauptman,
K. Kawagoe,
L. Linssen,
R. Lipton,
W. Lohmann,
T. Matsuda,
T. Nelson,
R. Poeschl,
E. Ramberg,
F. Sefkow,
M. Vos,
M. Wing,
J. Yu
Abstract:
This note summarises the workshop LCTW09 held between the 3.11.2009 and 5.11.2009 at LAL Orsay. The workshop was dedicated to discuss the beam tests in the years 2010 up to 2013 for detectors to be operated at a future linear electron positron collider. The document underlines the rich R&D program on these detectors in the coming years. Large synergies were identified in the DAQ and software syste…
▽ More
This note summarises the workshop LCTW09 held between the 3.11.2009 and 5.11.2009 at LAL Orsay. The workshop was dedicated to discuss the beam tests in the years 2010 up to 2013 for detectors to be operated at a future linear electron positron collider. The document underlines the rich R&D program on these detectors in the coming years. Large synergies were identified in the DAQ and software systems. Considerable consolidation of resources are expected from the establishment of semi-permanent beam lines for linear collider detector R&D at major centres like CERN and FNAL. Reproducing a beam structure as foreseen for the International Linear Collider (ILC) would clearly enhance the value of the obtained beam test results. Although not ultimately needed for every research program, all groups would exploit such a feature if it is available.
△ Less
Submitted 7 October, 2010;
originally announced October 2010.
-
Forward Instrumentation for ILC Detectors
Authors:
Halina Abramowicz,
Angel Abusleme,
Konstantin Afanaciev,
Jonathan Aguilar,
Prasoon Ambalathankandy,
Philip Bambade,
Matthias Bergholz,
Ivanka Bozovic-Jelisavcic,
Elena Castro,
Georgy Chelkov,
Cornelia Coca,
Witold Daniluk,
Angelo Dragone,
Laurentiu Dumitru,
Konrad Elsener,
Igor Emeliantchik,
Tomasz Fiutowski,
Mikhail Gostkin,
Christian Grah,
Grzegorz Grzelak,
Gunter Haller,
Hans Henschel,
Alexandr Ignatenko,
Marek Idzik,
Kazutoshi Ito
, et al. (33 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions wil…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions will allow a fast luminosity estimate and the determination of beam parameters. The sensors of this calorimeter must be radiation hard. Both devices will improve the hermeticity of the detector in the search for new particles. Finely segmented and very compact calorimeters will match the requirements. Due to the high occupancy fast front-end electronics is needed. The design of the calorimeters developed and optimised with Monte Carlo simulations is presented. Sensors and readout electronics ASICs have been designed and prototypes are available. Results on the performance of these major components are summarised.
△ Less
Submitted 3 November, 2010; v1 submitted 13 September, 2010;
originally announced September 2010.
-
Fast Beam Conditions Monitor BCM1F for the CMS Experiment
Authors:
A. Bell,
E. Castro,
R. Hall-Wilton,
W. Lange,
W. Lohmann,
A. Macpherson,
M. Ohlerich,
N. Rodriguez,
V. Ryjov,
R. S. Schmidt,
R. L. Stone
Abstract:
The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of different sub-systems measuring either the particle flux near the beam pipe with time resolution between nano- and microseconds or the integrated dose over longer tim…
▽ More
The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of different sub-systems measuring either the particle flux near the beam pipe with time resolution between nano- and microseconds or the integrated dose over longer time intervals. This paper presents the Fast Beam Conditions Monitor, BCM1F, which is designed for fast flux monitoring measuring both beam halo and collision products. BCM1F is located inside the CMS pixel detector volume close to the beam-pipe. It uses sCVD diamond sensors and radiation hard front-end electronics, along with an analog optical readout of the signals. The commissioning of the system and its successful operation during the first be ams of the LHC are described.
△ Less
Submitted 18 December, 2009; v1 submitted 12 November, 2009;
originally announced November 2009.
-
R&D for Very Forward Calorimeters at the ILC Detector
Authors:
W. Lohmann
Abstract:
Special calorimeters are needed to instrument the very forward region of an ILC detector. These devices will improve the hermeticity being important for new particle searches. A luminometer is foreseen to measure the rate of low angle Bhabha scattering with a precision better than 10-3. A calorimeter adjacent to the beam-pipe will be hit by a large amount of beamstrahlung remnants. The amount an…
▽ More
Special calorimeters are needed to instrument the very forward region of an ILC detector. These devices will improve the hermeticity being important for new particle searches. A luminometer is foreseen to measure the rate of low angle Bhabha scattering with a precision better than 10-3. A calorimeter adjacent to the beam-pipe will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions will allow a fast luminosity estimate and the determination of beam parameters. However, the sensors must be extremely radiation hard. Finely segmented and very compact calorimeters will match the requirements. Due to the high occupancy fast FE electronics is needed. A possible design of the calorimeters is presented and an overview on the R&D status is given
△ Less
Submitted 19 February, 2009;
originally announced February 2009.
-
The Impact of BeamCal Performance at Different ILC Beam Parameters and Crossing Angles on \tilde{tau} searches
Authors:
P. Bambade,
V. Drugakov,
W. Lohmann
Abstract:
The ILC accelerator parameters and detector concepts are still under discussion in the world-wide community. As will be shown, the performance of the BeamCal, the calorimeter in the very forward area of the ILC detector, is very sensitive to the beam parameter and crossing angle choices. We propose here BeamCal designs for a small (0 or 2 mrad) and large (20 mrad) crossing angles and report abou…
▽ More
The ILC accelerator parameters and detector concepts are still under discussion in the world-wide community. As will be shown, the performance of the BeamCal, the calorimeter in the very forward area of the ILC detector, is very sensitive to the beam parameter and crossing angle choices. We propose here BeamCal designs for a small (0 or 2 mrad) and large (20 mrad) crossing angles and report about the veto performance study done. As illustration, the influence of several proposed beam parameter sets and crossing-angles on the signal to background ratio in the stau search is estimated for a particular realization of the super-symmetric model.
△ Less
Submitted 19 October, 2006;
originally announced October 2006.
-
Beam Calorimeter Technologies
Authors:
R. Dollan,
Ch. Grah,
E. Kuznetsova,
W. Lange,
W. Lohmann,
A. Stahl,
K. Afanaciev,
V. Drugakov,
I. Emeliantchik
Abstract:
Two different technologies are considered for the Beam Calorimeters of the ILC detector. Simulation studies of the performance have been done for a diamond-tungsten sandwich calorimeter and for a homogeneous heavy element crystal calorimeter with optical fiber readout. Studies of the stability and the linearity of a polycrystalline diamond were done for the diamond-tungsten option. For the heavy…
▽ More
Two different technologies are considered for the Beam Calorimeters of the ILC detector. Simulation studies of the performance have been done for a diamond-tungsten sandwich calorimeter and for a homogeneous heavy element crystal calorimeter with optical fiber readout. Studies of the stability and the linearity of a polycrystalline diamond were done for the diamond-tungsten option. For the heavy crystal option the light yield reduction due to the wavelength shifting fiber readout was studied.
△ Less
Submitted 25 July, 2005; v1 submitted 1 July, 2005;
originally announced July 2005.