Skip to main content

Showing 1–33 of 33 results for author: Loddo, F

Searching in archive physics. Search in all archives.
.
  1. arXiv:2302.02764  [pdf, other

    physics.ins-det hep-ex

    Machine Learning based tool for CMS RPC currents quality monitoring

    Authors: E. Shumka, A. Samalan, M. Tytgat, M. El Sawy, G. A. Alves, F. Marujo, E. A. Coelho, E. M. Da Costa, H. Nogima, A. Santoro, S. Fonseca De Souza, D. De Jesus Damiao, M. Thiel, K. Mota Amarilo, M. Barroso Ferreira Filho, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, M. Rodozov, M. Shopova, G. Soultanov, A. Dimitrov, L. Litov, B. Pavlov, P. Petkov , et al. (83 additional authors not shown)

    Abstract: The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly m… ▽ More

    Submitted 6 February, 2023; originally announced February 2023.

  2. RPC based tracking system at CERN GIF++ facility

    Authors: K. Mota Amarilo, A. Samalan, M. Tytgat, M. El Sawy, G. A. Alves, F. Marujo, E. A. Coelho, E. M. Da Costa, H. Nogima, A. Santoro, S. Fonseca De Souza, D. De Jesus Damiao, M. Thiel, M. Barroso Ferreira Filho, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, M. Rodozov, M. Shopova, G. Soultanov, A. Dimitrov, L. Litov, B. Pavlov, P. Petkov, A. Petrov , et al. (83 additional authors not shown)

    Abstract: With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system… ▽ More

    Submitted 29 November, 2022; originally announced November 2022.

    Comments: 12 pages, 9 figures. Contribution to XVI Workshop on Resistive Plate Chambers and Related Detectors (RPC2022), September 26-30 2022. Submitted to Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

  3. arXiv:2203.12037  [pdf, other

    physics.ins-det hep-ex

    Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade

    Authors: M. Abbas, M. Abbrescia, H. Abdalla, A. Abdelalim, S. AbuZeid, A. Agapitos, A. Ahmad, A. Ahmed, W. Ahmed, C. Aimè, C. Aruta, I. Asghar, P. Aspell, C. Avila, J. Babbar, Y. Ban, R. Band, S. Bansal, L. Benussi, T. Beyrouthy, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi , et al. (157 additional authors not shown)

    Abstract: The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton co… ▽ More

    Submitted 22 March, 2022; originally announced March 2022.

    Comments: 45 pages, 39 figures, submitted to Nuclear Instruments and Methods in Physics Research Section A

  4. arXiv:2109.14331  [pdf, other

    physics.ins-det hep-ex

    Upgrade of the CMS Resistive Plate Chambers for the High Luminosity LHC

    Authors: A. Samalan, M. Tytgat, G. A. Alves, F. Marujo, F. Torres Da Silva De Araujo, E. M. DaCosta, D. De Jesus Damiao, H. Nogima, A. Santoro, S. Fonseca De Souza, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, M. Rodozov, M. Shopova, G. Soultanov, M. Bonchev, A. Dimitrov, L. Litov, B. Pavlov, P. Petkov, A. Petrov, S. J. Qian, C. Bernal, A. Cabrera , et al. (86 additional authors not shown)

    Abstract: During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solen… ▽ More

    Submitted 2 November, 2021; v1 submitted 29 September, 2021; originally announced September 2021.

  5. arXiv:2107.09364  [pdf, other

    physics.ins-det hep-ex

    Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector

    Authors: M. Abbas, M. Abbrescia, H. Abdalla, A. Abdelalim, S. AbuZeid, A. Agapitos, A. Ahmad, A. Ahmed, W. Ahmed, C. Aimè, C. Aruta, I. Asghar, P. Aspell, C. Avila, J. Babbar, Y. Ban, R. Band, S. Bansal, L. Benussi, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi, O. Bouhali , et al. (156 additional authors not shown)

    Abstract: After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstr… ▽ More

    Submitted 22 September, 2021; v1 submitted 20 July, 2021; originally announced July 2021.

    Comments: 10 pages, 5 figures

  6. arXiv:2107.03621  [pdf, other

    physics.ins-det hep-ex

    Modeling the triple-GEM detector response to background particles for the CMS Experiment

    Authors: M. Abbas, M. Abbrescia, H. Abdalla, A. Abdelalim, S. AbuZeid, A. Agapitos, A. Ahmad, A. Ahmed, W. Ahmed, C. Aimè, C. Aruta, I. Asghar, P. Aspell, C. Avila, I. Azhgirey, J. Babbar, Y. Ban, R. Band, S. Bansal, L. Benussi, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi , et al. (164 additional authors not shown)

    Abstract: An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The… ▽ More

    Submitted 8 July, 2021; originally announced July 2021.

    Comments: 16 pages, 9 figures, 6 tables

  7. arXiv:2009.09505  [pdf, other

    physics.ins-det hep-ex

    Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade

    Authors: M. Abbas, M. Abbrescia, H. Abdalla, A. Abdelalim, S. AbuZeid, A. Agapitos, A. Ahmad, A. Ahmed, W. Ahmed, C. Aimè, C. Aruta, I. Asghar, P. Aspell, C. Avila, J. Babbar, Y. Ban, R. Band, S. Bansal, L. Benussi, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi, O. Bouhali , et al. (156 additional authors not shown)

    Abstract: We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequent… ▽ More

    Submitted 20 September, 2020; originally announced September 2020.

    Comments: 22 pages, 14 figures

    Journal ref: 2020 JINST 15 P12019

  8. arXiv:2005.12769  [pdf, other

    physics.ins-det hep-ex

    CMS RPC Background -- Studies and Measurements

    Authors: R. Hadjiiska, A. Samalan, M. Tytgat, N. Zaganidis, G. A. Alves, F. Marujo, F. Torres Da Silva De Araujo, E. M. Da Costa, D. De Jesus Damiao, H. Nogima, A. Santoro, S. Fonseca De Souza, A. Aleksandrov, P. Iaydjiev, M. Rodozov, M. Shopova, G. Sultanov, M. Bonchev, A. Dimitrov, L. Litov, B. Pavlov, P. Petkov, A. Petrov, S. J. Qian, C. Bernal , et al. (84 additional authors not shown)

    Abstract: The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be upd… ▽ More

    Submitted 13 December, 2020; v1 submitted 26 May, 2020; originally announced May 2020.

    Comments: 6 pages, Conference proceeding for the 2020 Resistive Plate Chambers and Related Detectors. Minor revision of the report, the results remain unchanged. Three new plots are added and some details were explained better

  9. arXiv:1706.00222  [pdf, other

    physics.ins-det hep-ex

    Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

    Authors: M. Dragicevic, M. Friedl, J. Hrubec, H. Steininger, A. Gädda, J. Härkönen, T. Lampén, P. Luukka, T. Peltola, E. Tuominen, E. Tuovinen, A. Winkler, P. Eerola, T. Tuuva, G. Baulieu, G. Boudoul, L. Caponetto, C. Combaret, D. Contardo, T. Dupasquier, G. Gallbit, N. Lumb, L. Mirabito, S. Perries, M. Vander Donckt , et al. (462 additional authors not shown)

    Abstract: A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator… ▽ More

    Submitted 1 June, 2017; originally announced June 2017.

    Report number: CMS-NOTE-2017-002

  10. arXiv:1512.08529  [pdf, ps, other

    physics.ins-det

    A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

    Authors: D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, O. Aboamer, D. Acosta, A. Ahmad, W. Ahmed, W. Ahmed, A. Aleksandrov, R. Aly, P. Altieri, C. Asawatangtrakuldee, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, V. Barashko, P. Barria, G. Bencze, N. Beni, L. Benussi , et al. (133 additional authors not shown)

    Abstract: We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active are… ▽ More

    Submitted 28 December, 2015; originally announced December 2015.

    Comments: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste, Italy). arXiv admin note: text overlap with arXiv:1512.08481

    Report number: INFN-15-10/LNF

  11. Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors

    Authors: D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, O. Aboamer, D. Acosta, A. Ahmad, W. Ahmed, W. Ahmed, A. Aleksandrov, R. Aly, P. Altieri, C. Asawatangtrakuldee, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, V. Barashko, P. Barria, G. Bencze, N. Beni, L. Benussi , et al. (133 additional authors not shown)

    Abstract: A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.

    Submitted 28 December, 2015; originally announced December 2015.

    Comments: Two pages, one figure. Presented by Luigi Benussi (corresponding author) to Elba 2015 conference

    Report number: Frascati Preprint INFN-15-09/LNF

  12. Trap** in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Authors: W. Adam, T. Bergauer, M. Dragicevic, M. Friedl, R. Fruehwirth, M. Hoch, J. Hrubec, M. Krammer, W. Treberspurg, W. Waltenberger, S. Alderweireldt, W. Beaumont, X. Janssen, S. Luyckx, P. Van Mechelen, N. Van Remortel, A. Van Spilbeeck, P. Barria, C. Caillol, B. Clerbaux, G. De Lentdecker, D. Dobur, L. Favart, A. Grebenyuk, Th. Lenzi , et al. (663 additional authors not shown)

    Abstract: The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi… ▽ More

    Submitted 7 May, 2015; originally announced May 2015.

    Journal ref: 2016 JINST 11 P04023

  13. arXiv:1503.07471  [pdf, other

    hep-ph hep-ex physics.ins-det

    Search for Sterile Neutrinos in the Muon Neutrino Disappearance Mode at FNAL

    Authors: A. Anokhina, A. Bagulya, M. Benettoni, P. Bernardini, R. Brugnera, M. Calabrese, A. Cecchetti, S. Cecchini, M. Chernyavskiy, F. Dal Corso, O. Dalkarov, A. Del Prete, G. De Robertis, M. De Serio, D. Di Ferdinando, S. Dusini, T. Dzhatdoev, R. A. Fini, G. Fiore, A. Garfagnini, M. Guerzoni, B. Klicek, U. Kose, K. Jakovcic, G. Laurenti , et al. (39 additional authors not shown)

    Abstract: The NESSiE Collaboration has been setup to undertake a conclusive experiment to clarify the {\em muon--neutrino disappearance} measurements at short baselines in order to put severe constraints to models with more than the three--standard neutrinos. To this aim the current FNAL--Booster neutrino beam for a Short--Baseline experiment was carefully evaluated by considering the use of magnetic spectr… ▽ More

    Submitted 2 February, 2017; v1 submitted 25 March, 2015; originally announced March 2015.

    Comments: 19 pages, published in EPJC

    Journal ref: Eur. Phys. J. C (2017) 77:23

  14. arXiv:1412.0228  [pdf, other

    physics.ins-det

    Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

    Authors: D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, W. Ahmed, W. Ahmed, P. Altieri, R. Aly, C. Asawatangtrakuldee, A. Ashfaq, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, P. Barria, L. Benussi, V. Bhopatkar, S. Bianco, J. Bos, O. Bouhali, S. Braibant, S. Buontempo , et al. (113 additional authors not shown)

    Abstract: Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips wi… ▽ More

    Submitted 8 December, 2014; v1 submitted 30 November, 2014; originally announced December 2014.

    Comments: 8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci. Symposium, Seattle, WA, reference added

  15. arXiv:1410.3980  [pdf, other

    hep-ph hep-ex physics.ins-det

    The NESSiE way to searches for sterile neutrinos at FNAL

    Authors: L. Stanco, A. Anokhina, A. Bagulya, M. Benettoni, P. Bernardini, R. Brugnera, M. Calabrese, A. Cecchetti, S. Cecchini, M. Chernyavskiy, P. Creti, F. Dal Corso, O. Dalkarov, A. Del Prete, G. De Robertis, M. De Serio, L. Degli Esposti, D. Di Ferdinando, S. Dusini, T. Dzhatdoev, C. Fanin, R. A. Fini, G. Fiore, A. Garfagnini, S. Golovanov , et al. (44 additional authors not shown)

    Abstract: Neutrino physics is nowadays receiving more and more attention as a possible source of information for the long-standing problem of new physics beyond the Standard Model. The recent measurement of the mixing angle $θ_{13}$ in the standard mixing oscillation scenario encourages us to pursue the still missing results on leptonic CP violation and absolute neutrino masses. However, puzzling measuremen… ▽ More

    Submitted 15 October, 2014; originally announced October 2014.

    Comments: Proceeding of ICHEP2014, 2-7 July 2014, Valencia (Spain), 12 pages, 6 figures

  16. arXiv:1404.2521  [pdf, other

    hep-ph hep-ex physics.ins-det

    Prospects for the measurement of muon-neutrino disappearance at the FNAL-Booster

    Authors: A. Anokhina, A. Bagulya, M. Benettoni, P. Bernardini, R. Brugnera, M. Calabrese, A. Cecchetti, S. Cecchini, M. Chernyavskiy, P. Creti, F. Dal Corso, O. Dalkarov, A. Del Prete, G. De Robertis, M. De Serio, L. Degli Esposti, D. Di Ferdinando, S. Dusini, T. Dzhatdoev, C. Fanin, R. A. Fini, G. Fiore, A. Garfagnini, S. Golovanov, M. Guerzoni , et al. (44 additional authors not shown)

    Abstract: Neutrino physics is nowadays receiving more and more attention as a possible source of information for the long-standing problem of new physics beyond the Standard Model. The recent measurement of the mixing angle $θ_{13}$ in the standard mixing oscillation scenario encourages us to pursue the still missing results on leptonic CP violation and absolute neutrino masses. However, puzzling measuremen… ▽ More

    Submitted 9 April, 2014; originally announced April 2014.

    Comments: 76 pages, 52 figures

  17. arXiv:1312.1227  [pdf, other

    hep-ph physics.ins-det

    The NESSiE Concept for Sterile Neutrinos

    Authors: L. Stanco, A. Anokhina, A. Bagulya, M. Benettoni, P. Bernardini, A. Bertolin, R. Brugnera, M. Calabrese, A. Cecchetti, S. Cecchini, M. Chernyavskiy, G. Collazuol, P. Creti, F. Dal Corso, O. Dalkarov, A. Del Prete, I. De Mitri, G. De Robertis, M. De Serio, L. Degli Esposti, D. Di Ferdinando, U. Dore, S. Dusini, T. Dzhatdoev, C. Fanin , et al. (56 additional authors not shown)

    Abstract: Neutrino physics is nowadays receiving more and more attention as a possible source of information for the long-standing problem of new physics beyond the Standard Model. The recent measurement of the third mixing angle theta13 in the standard mixing oscillation scenario encourages us to pursue the still missing results on leptonic CP violation and absolute neutrino masses. However, several puzzli… ▽ More

    Submitted 4 December, 2013; originally announced December 2013.

    Comments: 13 pages, Proceedings of XV Workshop on Neutrino Telescopes, 11-15 March 2013, Venice, Italy

  18. arXiv:1306.5655  [pdf, other

    physics.ins-det hep-ex

    SuperB Technical Design Report

    Authors: SuperB Collaboration, M. Baszczyk, P. Dorosz, J. Kolodziej, W. Kucewicz, M. Sapor, A. Jeremie, E. Grauges Pous, G. E. Bruno, G. De Robertis, D. Diacono, G. Donvito, P. Fusco, F. Gargano, F. Giordano, F. Loddo, F. Loparco, G. P. Maggi, V. Manzari, M. N. Mazziotta, E. Nappi, A. Palano, B. Santeramo, I. Sgura, L. Silvestris , et al. (384 additional authors not shown)

    Abstract: In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch… ▽ More

    Submitted 24 June, 2013; originally announced June 2013.

    Comments: 495 pages

    Report number: INFN-13-01/PI, LAL 13-01, SLAC-R-1003

  19. arXiv:1301.6978  [pdf, other

    physics.ins-det hep-ex

    Simulation of the CMS Resistive Plate Chambers

    Authors: R. Hadjiiska, L. Litov, B. Pavlov, P. Petkov, A. Dimitrov, K. Beernaert, A. Cimmino, S. Costantini, G. Garcia, J. Lellouch, A. Marinov, A. Ocampo, N. Strobbe, F. Thyssen, M. Tytgat, P. Verwilligen, E. Yazgan, N. Zaganidis, A. Aleksandrov, V. Genchev, P. Iaydjiev, M. Rodozov, M. Shopova, G. Sultanov, Y. Ban , et al. (39 additional authors not shown)

    Abstract: The Resistive Plate Chamber (RPC) muon subsystem contributes significantly to the formation of the trigger decision and reconstruction of the muon trajectory parameters. Simulation of the RPC response is a crucial part of the entire CMS Monte Carlo software and directly influences the final physical results. An algorithm based on the parametrization of RPC efficiency, noise, cluster size and timin… ▽ More

    Submitted 29 January, 2013; originally announced January 2013.

    Comments: to be published in JINST

  20. arXiv:1211.3939  [pdf, ps, other

    physics.ins-det

    Beam Test Results for New Full-scale GEM Prototypes for a Future Upgrade of the CMS High-eta Muon System

    Authors: D. Abbaneo, M. Abbrescia, C. Armagnaud, P. Aspell, Y. Assran, Y. Ban, S. Bally, L. Benussi, U. Berzano, S. Bianco, J. Bos, K. Bunkowski, J. Cai, J. P. Chatelain, J. Christiansen, S. Colafranceschi, A. Colaleo, A. Conde Garcia, E. David, G. de Robertis, R. De Oliveira, S. Duarte Pinto, S. Ferry, F. Formenti, L. Franconi , et al. (34 additional authors not shown)

    Abstract: The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-eta region. Employing a new faster construction and assembly t… ▽ More

    Submitted 16 November, 2012; originally announced November 2012.

    Comments: 5 pages, 9 figures, submitted to Proc. 2012 IEEE Nucl. Sci. Symposium, Anaheim, CA

  21. arXiv:1209.3893  [pdf, ps, other

    hep-ex physics.ins-det

    Performance of the Gas Gain Monitoring system of the CMS RPC muon detector and effective working point fine tuning

    Authors: S. Colafranceschi, L. Benussi, S. Bianco, L. Passamonti, D. Piccolo, D. Pierluigi, A. Russo, G. Saviano, C. Vendittozzi, M. Abbrescia, A. Aleksandrov, U. Berzano, C. Calabria, C. Carrillo, A. Colaleo, V. Genchev, P. Iaydjiev, M. Kang, K. S. Lee, F. Loddo, S. K. Park, G. Pugliese, M. Maggi, S. Shin, M. Rodozov , et al. (3 additional authors not shown)

    Abstract: The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas mixture changes in the closed loop recirculation system. In 2011 the GGM began to operate using a feedback algorithm to control the applied voltage, in order to keep… ▽ More

    Submitted 18 September, 2012; originally announced September 2012.

  22. arXiv:1209.1989  [pdf, ps, other

    physics.ins-det hep-ex

    Uniformity and Stability of the CMS RPC Detector at the LHC

    Authors: S. Costantini, K. Beernaert, A. Cimmino, G. Garcia, J. Lellouch, A. Marinov, A. Ocampo, N. Strobbe, F. Thyssen, M. Tytgat, P. Verwilligen, E. Yazgan, N. Zaganidis, A. Dimitrov, R. Hadjiiska, L. Litov, B. Pavlov, P. Petkov, A. Aleksandrov, V. Genchev, P. Iaydjiev, M. Rodozov, M. Shopova, G. Sultanov, Y. Ban , et al. (38 additional authors not shown)

    Abstract: The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data taking period, and preliminary results obtained with 2012 data. The detector uniformity has been ensured with a dedicated High Voltage scan with LHC collisions… ▽ More

    Submitted 10 September, 2012; originally announced September 2012.

    Comments: Plenary talk presented at RPC2012. Part of JINST RPC2012 special issue

  23. arXiv:1209.1979  [pdf, ps, other

    physics.ins-det hep-ex

    The Upgrade of the CMS RPC System during the First LHC Long Shutdown

    Authors: M. Tytgat, A. Marinov, P. Verwilligen, N. Zaganidis, A. Aleksandrov, V. Genchev, P. Iaydjiev, M. Rodozov, M. Shopova, G. Sultanov, Y. Assran, M. Abbrescia, C. Calabria, A. Colaleo, G. Iaselli, F. Loddo, M. Maggi, G. Pugliese, L. Benussi, S. Bianco, M. Caponero, S. Colafranceschi, F. Felli, D. Piccolo, G. Saviano , et al. (9 additional authors not shown)

    Abstract: The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon parameters. Over the years, the instantaneous luminosity of the Large Hadron Collider gradually increases. During the LHC Phase 1 (~first 10 years of operation) an ultimate luminosity is expected above its design value… ▽ More

    Submitted 10 September, 2012; originally announced September 2012.

    Comments: 9 pages, 6 figures, presented by M.Tytgat at the XI workshop on Resistive Plate Chambers and Related Detectors (RPC2012), INFN - Laboratori Nazionali di Frascati, February 5-10, 2012

  24. arXiv:1209.1941  [pdf

    physics.ins-det hep-ex

    CMS Resistive Plate Chamber overview, from the present system to the upgrade phase I

    Authors: P. Paolucci, R. Hadjiiska, L. Litov, B. Pavlov, P. Petkov, A. Dimitrov, K. Beernaert, A. Cimmino, S. Costantini, G. Guillaume, J. Lellouch, A. Marinov, A. Ocampo, N. Strobbe, F. Thyssen, M. Tytgat, P. Verwilligen, E. Yazgan, N. Zaganidis, A. Aleksandrov, V. Genchev, P. Iaydjiev, M. Rodozov, M. Shopova, G. Sultanov , et al. (38 additional authors not shown)

    Abstract: University of Sofia, Faculty of Physics, Atomic Physics Department, 5, James Bourchier Boulevard, BG-1164 Sofia, Bulgaria Ghent University, Department of Physics and Astronomy, Proeftuinstraat 86, BE-9000 Ghent, Belgium Bulgarian Academy of Sciences, Inst. for Nucl. Res. and Nucl. Energy, Tzarigradsko shaussee Boulevard 72, BG-1784 Sofia, Bulgaria Peking University, Department of Technical Physics… ▽ More

    Submitted 10 September, 2012; originally announced September 2012.

    Comments: Conference Report for the "RPC2012 Conference" held in Frascati (ITALY) 12 pages, 10 figures

  25. arXiv:1208.0862  [pdf, other

    physics.ins-det hep-ex hep-ph

    Search for anomalies in the neutrino sector with muon spectrometers and large LArTPC imaging detectors at CERN

    Authors: M. Antonello, D. Bagliani, B. Baibussinov, H. Bilokon, F. Boffelli, M. Bonesini, E. Calligarich, N. Canci, S. Centro, A. Cesana, K. Cieslik, D. B. Cline, A. G. Cocco, D. Dequal, A. Dermenev, R. Dolfini, M. De Gerone, S. Dussoni, C. Farnese, A. Fava, A. Ferrari, G. Fiorillo, G. T. Garvey, F. Gatti, D. Gibin , et al. (114 additional authors not shown)

    Abstract: A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed in order to definitely clarify the possible existence of additional neutrino states, as pointed out by neutrino calibration source experiments, reactor and accelerator experiments and measure the corresponding oscillation parameters. The experiment is based on two identical LAr-TPCs complemented by magnetized spectromete… ▽ More

    Submitted 28 September, 2012; v1 submitted 3 August, 2012; originally announced August 2012.

    Comments: Contribution to the European Strategy for Particle Physics - Open Symposium Preparatory Group, Kracow 10-12 September 2012

  26. arXiv:1203.3432  [pdf

    physics.ins-det hep-ex

    Search for "anomalies" from neutrino and anti-neutrino oscillations at Delta_m^2 ~ 1eV^2 with muon spectrometers and large LAr-TPC imaging detectors

    Authors: M. Antonello, D. Bagliani, B. Baibussinov, H. Bilokon, F. Boffelli, M. Bonesini, E. Calligarich, N. Canci, S. Centro, A. Cesana, K. Cieslik, D. B. Cline, A. G. Cocco, D. Dequal, A. Dermenev, R. Dolfini, M. De Gerone, S. Dussoni, C. Farnese, A. Fava, A. Ferrari, G. Fiorillo, G. T. Garvey, F. Gatti, D. Gibin , et al. (114 additional authors not shown)

    Abstract: This proposal describes an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN "Far" position. An a… ▽ More

    Submitted 29 March, 2012; v1 submitted 15 March, 2012; originally announced March 2012.

    Comments: Experiment proposal

    Report number: CERN-SPSC-2012-010 and SPSC-P-347

  27. arXiv:1111.7249  [pdf, ps, other

    physics.ins-det hep-ex

    Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System

    Authors: M. Tytgat, A. Marinov, N. Zaganidis, Y. Ban, J. Cai, H. Teng, A. Mohapatra, T. Moulik, M. Abbrescia, A. Colaleo, G. de Robertis, F. Loddo, M. Maggi, S. Nuzzo, S. A. Tupputi, L. Benussi, S. Bianco, S. Colafranceschi, D. Piccolo, G. Raffone, G. Saviano, M. G. Bagliesi, R. Cecchi, G. Magazzu, E. Oliveri , et al. (34 additional authors not shown)

    Abstract: At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas dete… ▽ More

    Submitted 30 November, 2011; originally announced November 2011.

    Comments: 7 pages, 25 figures, submitted for publication in conference record of the 2011 IEEE Nuclear Science Symposium, Valencia, Spain

    Report number: RD51-Note-2011-012

  28. arXiv:1111.4883  [pdf, ps, other

    physics.ins-det hep-ex

    Test beam results of the GE1/1 prototype for a future upgrade of the CMS high-$η$ muon system

    Authors: D. Abbaneo, M. Abbrescia, C. Armagnaud, P. Aspell, M. G. Bagliesi, Y. Ban, S. Bally, L. Benussi, U. Berzano, S. Bianco, J. Bos, K. Bunkowski, J. Cai, R. Cecchi, J. P. Chatelain, J. Christiansen, S. Colafranceschi, A. Colaleo, A. Conde Garcia, E. David, G. de Robertis, R. De Oliveira, S. Duarte Pinto, S. Ferry, F. Formenti , et al. (33 additional authors not shown)

    Abstract: Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The const… ▽ More

    Submitted 30 November, 2011; v1 submitted 21 November, 2011; originally announced November 2011.

  29. arXiv:1003.3770  [pdf, ps, other

    physics.ins-det hep-ex

    Status of the Cylindical-GEM project for the KLOE-2 Inner Tracker

    Authors: A. Balla, G. Bencivenni, S. Cerioni, P. Ciambrone, E. De Lucia, G. De Robertis, D. Domenici, G. Felici, M. Gatta, M. Jacewicz, N. Lacalamita, S. Lauciani, R. Liuzzi, F. Loddo, M. Mongelli, G. Morello, A. Pelosi, M. Pistilli, L. Quintieri, A. Ranieri, V. Valentino

    Abstract: The status of the R&D on the Cylindrical-GEM (CGEM) detector foreseen as Inner Tracker for KLOE-2, the upgrade of the KLOE experiment at the DAFNE phi-factory, will be presented. The R&D includes several activities: i) the construction and complete characterization of the full-size CGEM prototype, equipped with 650 microns pitch 1-D longitudinal strips; ii) the study of the 2-D readout with XV pat… ▽ More

    Submitted 19 March, 2010; originally announced March 2010.

    Comments: 4 pages, 10 figures, Presented at Vienna Conference on Instrumentation (Feb 15-20, 2010, Vienna, Austria). Submitted to the Proceedings

  30. arXiv:1002.2572  [pdf, ps, other

    physics.ins-det hep-ex

    Technical Design Report of the Inner Tracker for the KLOE-2 experiment

    Authors: KLOE-2 Collaboration, :, F. Archilli, D. Badoni, D. Babusci, G. Bencivenni, C. Bini, C. Bloise, V. Bocci, F. Bossi, P. Branchini, A. Budano, S. A. Bulychjev, P. Campana, G. Capon, F. Ceradini, P. Ciambrone, E. Czerwinski, E. Danè, E. De Lucia, G. De Robertis, A. De Santis, G. De Zorzi, A. Di Domenico, C. Di Donato , et al. (59 additional authors not shown)

    Abstract: The technical design report of the Inner Tracker for the KLOE-2 experiment is presented

    Submitted 12 February, 2010; originally announced February 2010.

    Comments: 77 pages

    Report number: LNF-10/3(P)

  31. Sensitivity and environmental response of the CMS RPC gas gain monitoring system

    Authors: L. Benussi, S. Bianco, S. Colafranceschi, F. L. Fabbri, M. Giardoni, B. Ortenzi, A. Paolozzi, L. Passamonti, D. Pierluigi, B. Ponzio, A. Russo, A. Colaleo, F. Loddo, M. Maggi, A. Ranieri, M. Abbrescia, G. Iaselli, B. Marangelli, S. Natali, S. Nuzzo, G. Pugliese, F. Romano, G. Roselli, R. Trentadue, S. Tupputi , et al. (13 additional authors not shown)

    Abstract: Results from the gas gain monitoring (GGM) system for the muon detector using RPC in the CMS experiment at the LHC is presented. The system is designed to provide fast and accurate determination of any shift in the working point of the chambers due to gas mixture changes.

    Submitted 9 December, 2008; originally announced December 2008.

    Comments: 8 pages, 7 figures, uses lnfprepCMS.sty, presented by S. Colafranceschi at IEEE 08 Dresden (Germany) November 2008

    Report number: Frascati Preprint LNF - 08 / 27(P)

    Journal ref: JINST 4:P08006,2009

  32. The CMS RPC gas gain monitoring system: an overview and preliminary results

    Authors: L. Benussi, S. Bianco, S. Colafranceschi, D. Colonna, L. Daniello, F. L. Fabbri, M. Giardoni, B. Ortenzi, A. Paolozzi, L. Passamonti, D. Pierluigi, B. Ponzio, C. Pucci, A. Russo, G. Roselli, A. Colaleo, F. Loddo, M. Maggi, A. Ranieri, M. Abbrescia, G. Iaselli, B. Marangelli, S. Natali, S. Nuzzo, G. Pugliese , et al. (18 additional authors not shown)

    Abstract: The status of the CMS RPC Gas Gain Monitoring (GGM) system developed at the Frascati Laboratory of INFN (Istituto Nazionale di Fisica Nucleare) is reported on. The GGM system is a cosmic ray telescope based on small RPC detectors operated with the same gas mixture used by the CMS RPC system. The GGM gain and efficiency are continuously monitored on-line, thus providing a fast and accurate determ… ▽ More

    Submitted 5 December, 2008; originally announced December 2008.

    Comments: 8 pages, 9 figures, uses lnfprepCMS.sty, presented by L. Benussi at RPC07, Mumbai, INDIA 2008

    Report number: Frascati PrePrint LNF-08/29(P)

    Journal ref: Nucl.Instrum.Meth.A602:805-808,2009

  33. arXiv:physics/0701014  [pdf, ps, other

    physics.ins-det

    Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC

    Authors: M. Abbrescia, A. Colaleo, R. Guida, G. Iaselli, R. Liuzzi, F. Loddo, M. Maggi, B. Marangelli, S. Natali, S. Nuzzo, G. Pugliese, A. Ranieri, F. Romano, R. Trentadue, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, D. Donisi, F. L. Fabbri, F. Felli, M. Giardoni B. Ortenzi, M. Pallotta, A. Paolozzi , et al. (16 additional authors not shown)

    Abstract: The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor… ▽ More

    Submitted 30 December, 2006; originally announced January 2007.

    Comments: 9 pages, 8 figures. Presented by Stefano Bianco (Laboratori Nazionali di Frascati dell'INFN) at the IEEE NSS, San Diego (USA), October 2006

    Report number: Frascati preprint LNF-06/34 (P)