-
Measurement of the distribution of $^{207}$Bi depositions on calibration sources for SuperNEMO
Authors:
R. Arnold,
C. Augier,
A. S. Barabash,
A. Basharina-Freshville,
E. Birdsall,
S. Blondel,
M. Bongrand,
D. Boursette,
R. Breier,
V. Brudanin,
J. Busto,
S. Calvez,
C. Cerna,
J. P. Cesar,
M. Ceschia,
A. Chapon,
E. Chauveau,
A. Chopra,
L. Dawson,
S. De Capua,
D. Duchesneau,
D. Durand,
G. Eurin,
J. J. Evans,
D. Filosofov
, et al. (75 additional authors not shown)
Abstract:
The SuperNEMO experiment will search for neutrinoless double-beta decay ($0νββ$), and study the Standard-Model double-beta decay process ($2νββ$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($ββ$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calib…
▽ More
The SuperNEMO experiment will search for neutrinoless double-beta decay ($0νββ$), and study the Standard-Model double-beta decay process ($2νββ$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($ββ$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of $^{207}$Bi within a frame assembly.
The quality of these sources, which depends upon the entire $^{207}$Bi droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of $^{207}$Bi droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.
△ Less
Submitted 20 May, 2021; v1 submitted 26 March, 2021;
originally announced March 2021.
-
Search for the double-beta decay of 82Se to the excited states of 82Kr with NEMO-3
Authors:
The NEMO-3 collaboration R. Arnold,
C. Augier,
A. S. Barabash,
A. Basharina-Freshville,
S. Blondel,
S. Blot,
M. Bongrand,
D. Boursette,
R. Breier,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
C. Cerna,
J. P. Cesar,
A. Chapon,
E. Chauveau,
A. Chopra,
L. Dawson,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin,
J. J. Evans
, et al. (82 additional authors not shown)
Abstract:
The double-beta decay of 82Se to the 0+1 excited state of 82Kr has been studied with the NEMO-3 detector using 0.93 kg of enriched 82Se measured for 4.75 y, corresponding to an exposure of 4.42 kg y. A dedicated analysis to reconstruct the gamma-rays has been performed to search for events in the 2e2g channel. No evidence of a 2nbb decay to the 0+1 state has been observed and a limit of T2n 1/2(82…
▽ More
The double-beta decay of 82Se to the 0+1 excited state of 82Kr has been studied with the NEMO-3 detector using 0.93 kg of enriched 82Se measured for 4.75 y, corresponding to an exposure of 4.42 kg y. A dedicated analysis to reconstruct the gamma-rays has been performed to search for events in the 2e2g channel. No evidence of a 2nbb decay to the 0+1 state has been observed and a limit of T2n 1/2(82Se; 0+gs -> 0+1) > 1.3 1021 y at 90% CL has been set. Concerning the 0nbb decay to the 0+1 state, a limit for this decay has been obtained with T0n 1/2(82Se; 0+g s -> 0+1) > 2.3 1022 y at 90% CL, independently from the 2nbb decay process. These results are obtained for the first time with a tracko-calo detector, reconstructing every particle in the final state.
△ Less
Submitted 17 January, 2020;
originally announced January 2020.
-
Low Background Gamma Spectroscopy at the Boulby Underground Laboratory
Authors:
P. R. Scovell,
E. Meehan,
H. M. Araújo,
J. Dobson,
C. Ghag,
H. Kraus,
V. A. Kudryavtsev,
X-. R. Liu,
P. Majewski,
S. M. Paling,
R. M. Preece,
R. Saakyan,
A. Tomás,
C. Toth,
L. M. Yeoman
Abstract:
The Boulby Underground Germanium Suite (BUGS) comprises three low background, high-purity germanium detectors operating in the Boulby Underground Laboratory, located 1.1 km underground in the north-east of England, UK. BUGS utilises three types of detector to facilitate a high-sensitivity, high-throughput radioassay programme to support the development of rare-event search experiments. A Broad Ene…
▽ More
The Boulby Underground Germanium Suite (BUGS) comprises three low background, high-purity germanium detectors operating in the Boulby Underground Laboratory, located 1.1 km underground in the north-east of England, UK. BUGS utilises three types of detector to facilitate a high-sensitivity, high-throughput radioassay programme to support the development of rare-event search experiments. A Broad Energy Germanium (BEGe) detector delivers sensitivity to low-energy gamma-rays such as those emitted by 210Pb and 234Th. A Small Anode Germanium (SAGe) well-type detector is employed for efficient screening of small samples. Finally, a standard p-type coaxial detector provides fast screening of standard samples. This paper presents the steps used to characterise the performance of these detectors for a variety of sample geometries, including the corrections applied to account for cascade summing effects. For low-density materials, BUGS is able to radio-assay to specific activities down to 3.6 mBq/kg for 234Th and 6.6 mBq/kg for 210Pb both of which have uncovered some significant equilibrium breaks in the 238U chain. In denser materials, where gamma-ray self-absorption increases, sensitivity is demonstrated to specific activities of 0.9 mBq/kg for 226Ra, 1.1 mBq/kg for 228 Ra, 0.3 mBq/kg for 224Ra, and 8.6 mBq/kg for 40K with all upper limits at a 90% confidence level. These meet the requirements of most screening campaigns presently under way for rare-event search experiments, such as the LUX-ZEPLIN (LZ) dark matter experiment. We also highlight the ability of the BEGe detector to probe the X-ray fluorescence region which can be important to identify the presence of radioisotopes associated with neutron production; this is of particular relevance in experiments sensitive to nuclear recoils.
△ Less
Submitted 15 November, 2017; v1 submitted 21 August, 2017;
originally announced August 2017.
-
Calorimeter development for the SuperNEMO double beta decay experiment
Authors:
A. S. Barabash,
A. Basharina-Freshville,
S. Blot,
M. Bongrand,
Ch. Bourgeois,
D. Breton,
V. Brudanin,
H. Burešovà,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
C. Cerna,
J. P. Cesar,
E. Chauveau,
A. Chopra,
G. Claverie,
S. De Capua,
F. Delalee,
D. Duchesneau,
V. Egorov,
G. Eurin,
J. J. Evans,
L. Fajt,
D. Filosofov
, et al. (73 additional authors not shown)
Abstract:
SuperNEMO is a double-$β$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$β$ decay isotope, reaching a sensitivity to the neutrinoless double-$β$ decay ($0νββ$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main…
▽ More
SuperNEMO is a double-$β$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$β$ decay isotope, reaching a sensitivity to the neutrinoless double-$β$ decay ($0νββ$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main goals and challenges of the SuperNEMO detector development programme has been to reach a calorimeter energy resolution, $Δ$E/E, around 3%/$sqrt(E)$(MeV) $σ$, or 7%/$sqrt(E)$(MeV) FWHM (full width at half maximum), using a calorimeter composed of large volume plastic scintillator blocks coupled to photomultiplier tubes. We describe the R\&D programme and the final design of the SuperNEMO calorimeter that has met this challenging goal.
△ Less
Submitted 21 July, 2017;
originally announced July 2017.
-
The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials
Authors:
A. S. Barabash,
A. Basharina-Freshville,
E. Birdsall,
S. Blondel,
S. Blot,
M. Bongrand,
D. Boursette,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
S. Cebrián,
C. Cerna,
J. P Cesar,
E. Chauveau,
A. Chopra,
T. Dafní,
S. De Capua,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin,
J. J. Evans,
L. Fajt
, et al. (71 additional authors not shown)
Abstract:
The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been…
▽ More
The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been developed to measure radiopurity of the selenium double $β$-decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in $^{208}$Tl and $^{214}$Bi, are presented, and validation of the BiPo-3 measurement with a calibrated aluminium foil is discussed. Results of the $^{208}$Tl and $^{214}$Bi activity measurements of the first enriched $^{82}$Se foils of the double $β$-decay SuperNEMO experiment are reported. The sensitivity of the BiPo-3 detector for the measurement of the SuperNEMO $^{82}$Se foils is $\mathcal{A}$($^{208}$Tl) $<2$ $μ$Bq/kg (90\% C.L.) and $\mathcal{A}$($^{214}$Bi) $<140$ $μ$Bq/kg (90\% C.L.) after 6 months of measurement.
△ Less
Submitted 7 June, 2017; v1 submitted 23 February, 2017;
originally announced February 2017.
-
Measurement of the 2$νββ$ decay half-life of $^{150}$Nd and a search for 0$νββ$ decay processes with the full exposure from the NEMO-3 detector
Authors:
NEMO-3 Collaboration,
:,
R. Arnold,
C. Augier,
J. D. Baker,
A. S. Barabash,
A. Basharina-Freshville,
S. Blondel,
S. Blot,
M. Bongrand,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascell,
C. Cerna,
J. P. Cesar,
A. Chapon,
E. Chauveau,
A. Chopra,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin,
J. J. Evans
, et al. (71 additional authors not shown)
Abstract:
We present results from a search for neutrinoless double-$β$ ($0νββ$) decay using 36.6 g of the isotope $^{150}$Nd with data corresponding to a live time of 5.25 y recorded with the NEMO-3 detector. We construct a complete background model for this isotope, including a measurement of the two-neutrino double-$β$ decay half-life of $T^{2ν}_{1/2}=$[9.34 $\pm$ 0.22 (stat.) $^{+0.62}_{-0.60}$ (syst.)]…
▽ More
We present results from a search for neutrinoless double-$β$ ($0νββ$) decay using 36.6 g of the isotope $^{150}$Nd with data corresponding to a live time of 5.25 y recorded with the NEMO-3 detector. We construct a complete background model for this isotope, including a measurement of the two-neutrino double-$β$ decay half-life of $T^{2ν}_{1/2}=$[9.34 $\pm$ 0.22 (stat.) $^{+0.62}_{-0.60}$ (syst.)]$\times 10^{18}$ y for the ground state transition, which represents the most precise result to date for this isotope. We perform a multivariate analysis to search for \zeronu decays in order to improve the sensitivity and, in the case of observation, disentangle the possible underlying decay mechanisms. As no evidence for \zeronu decay is observed, we derive lower limits on half-lives for several mechanisms involving physics beyond the Standard Model. The observed lower limit, assuming light Majorana neutrino exchange mediates the decay, is $T^{0ν}_{1/2} >$ 2.0 $\times 10^{22}$ y at the 90% C.L., corresponding to an upper limit on the effective neutrino mass of $\langle m_ν \rangle$ $<$ 1.6 - 5.3 eV..
△ Less
Submitted 12 October, 2016; v1 submitted 27 June, 2016;
originally announced June 2016.
-
Measurement of the double-beta decay half-life and search for the neutrinoless double-beta decay of $^{48}{\rm Ca}$ with the NEMO-3 detector
Authors:
NEMO-3 Collaboration,
:,
R. Arnold,
C. Augier,
A. M. Bakalyarov,
J. D. Baker,
A. S. Barabash,
A. Basharina-Freshville,
S. Blondel,
S. Blot,
M. Bongrand,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
C. Cerna,
J. P. Cesar,
A. Chapon,
E. Chauveau,
A. Chopra,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin
, et al. (75 additional authors not shown)
Abstract:
The NEMO-3 experiment at the Modane Underground Laboratory has investigated the double-$β$ decay of $^{48}{\rm Ca}$. Using $5.25$ yr of data recorded with a $6.99\,{\rm g}$ sample of $^{48}{\rm Ca}$, approximately $150$ double-$β$ decay candidate events have been selected with a signal-to-background ratio greater than $3$. The half-life for the two-neutrino double-$β$ decay of $^{48}{\rm Ca}$ has…
▽ More
The NEMO-3 experiment at the Modane Underground Laboratory has investigated the double-$β$ decay of $^{48}{\rm Ca}$. Using $5.25$ yr of data recorded with a $6.99\,{\rm g}$ sample of $^{48}{\rm Ca}$, approximately $150$ double-$β$ decay candidate events have been selected with a signal-to-background ratio greater than $3$. The half-life for the two-neutrino double-$β$ decay of $^{48}{\rm Ca}$ has been measured to be $T^{2ν}_{1/2}\,=\,[6.4\, ^{+0.7}_{-0.6}{\rm (stat.)} \, ^{+1.2}_{-0.9}{\rm (syst.)}] \times 10^{19}\,{\rm yr}$. A search for neutrinoless double-$β$ decay of $^{48}{\rm Ca}$ yields a null result and a corresponding lower limit on the half-life is found to be $T^{0ν}_{1/2} > 2.0 \times 10^{22}\,{\rm yr}$ at $90\%$ confidence level, translating into an upper limit on the effective Majorana neutrino mass of $< m_{ββ} > < 6.0 - 26$ ${\rm eV}$, with the range reflecting different nuclear matrix element calculations. Limits are also set on models involving Majoron emission and right-handed currents.
△ Less
Submitted 16 June, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
UK low-background infrastructure for delivering SuperNEMO
Authors:
Xin Ran Liu
Abstract:
SuperNEMO is a next generation neutrinoless double beta decay experiment with a design capability to reach a half-life sensitivity of $10^{26}$ years corresponding to an effective Majorana neutrino mass of $\langle m_{ββ} \rangle$ $<$ 50 - 100 meV. To achieve this sensitivity, stringent radio-purity requirements are imposed resulting in an equally stringent screening programme. Dedicated facilitie…
▽ More
SuperNEMO is a next generation neutrinoless double beta decay experiment with a design capability to reach a half-life sensitivity of $10^{26}$ years corresponding to an effective Majorana neutrino mass of $\langle m_{ββ} \rangle$ $<$ 50 - 100 meV. To achieve this sensitivity, stringent radio-purity requirements are imposed resulting in an equally stringent screening programme. Dedicated facilities have been established in the UK for screening and selection of detector construction materials.
Gamma ray spectroscopy using high-purity germanium (HPGe) detectors has been the standard method for the measurement of material contamination. A low-background facility has been established at Boulby Underground Laboratory. The first results from the 2 current HPGe detector are shown.
Radon is one of the most critical backgrounds for SuperNEMO and most other low background experiments. It can enter the detector either through diffusion, contamination during construction or emanation from the detector materials resulting in radioactive daughter isotopes. To reach the target sensitivity, the $^{222}$Rn concentration inside the SuperNEMO tracker volume must be less than 150 $μ$Bq/m3.
A "Radon Concentration Line" (RnCL) was developed to be used in conjunction with a state-of-the-art radon detector to make a more sensitive measurement of large gas volumes. This apparatus has now been commissioned and is capable of measuring radon levels in large samples down to 10 $μ$Bq/m3. The results from first measurements of radon content using the RnCL are presented. These measurements include gas bottles, boil-off nitrogen and a SuperNEMO sub-module during the early stages of construction.
△ Less
Submitted 30 April, 2015;
originally announced April 2015.