Skip to main content

Showing 1–40 of 40 results for author: Lippincott, W

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.12874  [pdf, other

    physics.ins-det hep-ex

    The Design, Implementation, and Performance of the LZ Calibration Systems

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, E. E. Barillier, J. W. Bargemann, K. Beattie, T. Benson, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, E. Bishop, G. M. Blockinger, B. Boxer , et al. (179 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low e… ▽ More

    Submitted 20 June, 2024; v1 submitted 2 May, 2024; originally announced June 2024.

  2. arXiv:2405.18403  [pdf, other

    physics.ins-det

    Batch VUV4 Characterization for the SBC-LAr10 scintillating bubble chamber

    Authors: H. Hawley-Herrera, E. Alfonso-Pita, E. Behnke, M. Bressler, B. Broerman, K. Clark, J. Corbett, C. E. Dahl, K. Dering, A. de St. Croix, D. Durnford, P. Giampa, J. Hall, O. Harris, N. Lamb, M. Laurin, I. Levine, W. H. Lippincott, X. Liu, N. Moss, R. Neilson, M. -C. Piro, D. Pyda, Z. Sheng, G. Sweeney , et al. (6 additional authors not shown)

    Abstract: The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. The VUV4 SiPMs, or Quads, underwent a characterization at two temperatures which measured the breakdown voltage ($V_{\text{BD}}$), the SiPM gain ($g_{\text{SiPM}}$), the rate of change of $g_{\text{SiPM}}$ with re… ▽ More

    Submitted 28 May, 2024; originally announced May 2024.

    Comments: 25 pages, 19 figures

    Report number: FERMILAB-PUB-24-0280-LDRD-PPD

  3. arXiv:2405.14732  [pdf, other

    physics.ins-det hep-ex

    The Data Acquisition System of the LZ Dark Matter Detector: FADR

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, E. E. Barillier, J. W. Bargemann, K. Beattie, T. Benson, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, E. Bishop, G. M. Blockinger, B. Boxer , et al. (190 additional authors not shown)

    Abstract: The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals.… ▽ More

    Submitted 23 May, 2024; originally announced May 2024.

    Comments: 18 pages, 24 figures

  4. arXiv:2304.06142  [pdf, other

    hep-ex physics.ins-det

    Nuclear recoil response of liquid xenon and its impact on solar 8B neutrino and dark matter searches

    Authors: X. Xiang, R. J. Gaitskell, R. Liu, J. Bang, J. Xu, W. H. Lippincott, J. Aalbers, J. E. Y. Dobson, M. Szydagis, G. R. C. Rischbieter, N. Parveen, D. Q. Huang, I. Olcina, R. J. James, J. A. Nikoleyczik

    Abstract: Knowledge of the ionization and scintillation responses of liquid xenon (LXe) to nuclear recoils is crucial for LXe-based dark matter experiments. Current calibrations carry large uncertainties in the low-energy region below $\sim3$ keV$_nr$ where signals from dark matter particles of $<$10 GeV/c$^2$ masses are expected. The coherent elastic neutrino-nucleus scattering (CE$ν$NS) by solar $^8$B neu… ▽ More

    Submitted 12 April, 2023; originally announced April 2023.

  5. arXiv:2211.17120  [pdf, other

    hep-ex physics.ins-det

    Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, S. K. Alsum, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, J. Bang, J. W. Bargemann, A. Baxter, K. Beattie, P. Beltrame, E. P. Bernard, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, G. M. Blockinger, B. Boxer , et al. (178 additional authors not shown)

    Abstract: The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-bet… ▽ More

    Submitted 17 July, 2023; v1 submitted 30 November, 2022; originally announced November 2022.

    Comments: 25 pages, 15 figures

    Journal ref: Phys. Rev. D 108, 012010 (2023)

  6. arXiv:2209.14111  [pdf, ps, other

    hep-ex physics.ins-det

    Report of the Instrumentation Frontier Working Group for Snowmass 2021

    Authors: Phillip S. Barbeau, Petra Merkel, **long Zhang, Darin Acosta, Anthony A. Affolder, Artur Apresyan, Marina Artuso, Vallary Bhopatkar, Stephen Butalla, Gabriella A. Carini, Thomas Cecil, Amy Connolly, C. Eric Dahl, Allison Deiana, Katherine Dunne, Carlos O. Escobar, Juan Estrada, Farah Fahim, James E. Fast, Maurice Garcia-Sciveres, Roxanne Guenette, Michael T. Hedges, Kent Irwin, Albrecht Karle, Wes Ketchum , et al. (20 additional authors not shown)

    Abstract: Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technol… ▽ More

    Submitted 3 November, 2022; v1 submitted 28 September, 2022; originally announced September 2022.

    Comments: 53 pages, 0 figures, contribution to Snowmass 2021

  7. arXiv:2207.12400  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$ν$NS Detection

    Authors: E. Alfonso-Pita, M. Baker, E. Behnke, A. Brandon, M. Bressler, B. Broerman, K. Clark, R. Coppejans, J. Corbett, C. Cripe, M. Crisler, C. E. Dahl, K. Dering, A. de St. Croix, D. Durnford, K. Foy, P. Giampa, J. Gresl, J. Hall, O. Harris, H. Hawley-Herrera, C. M. Jackson, M. Khatri, Y. Ko, N. Lamb , et al. (20 additional authors not shown)

    Abstract: The Scintillating Bubble Chamber (SBC) Collaboration is develo** liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This dev… ▽ More

    Submitted 29 September, 2022; v1 submitted 21 July, 2022; originally announced July 2022.

    Comments: 35 pages, 12 figures, contributed white paper to Snowmass 2021 (final version for Snowmass proceedings)

    Report number: FERMILAB-CONF-22-535-LDRD-PPD

  8. arXiv:2203.02309  [pdf, other

    physics.ins-det astro-ph.CO hep-ex nucl-ex

    A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics

    Authors: J. Aalbers, K. Abe, V. Aerne, F. Agostini, S. Ahmed Maouloud, D. S. Akerib, D. Yu. Akimov, J. Akshat, A. K. Al Musalhi, F. Alder, S. K. Alsum, L. Althueser, C. S. Amarasinghe, F. D. Amaro, A. Ames, T. J. Anderson, B. Andrieu, N. Angelides, E. Angelino, J. Angevaare, V. C. Antochi, D. Antón Martin, B. Antunovic, E. Aprile, H. M. Araújo , et al. (572 additional authors not shown)

    Abstract: The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut… ▽ More

    Submitted 4 March, 2022; originally announced March 2022.

    Comments: 77 pages, 40 figures, 1262 references

    Report number: INT-PUB-22-003

    Journal ref: J. Phys. G: Nucl. Part. Phys. 50 (2023) 013001

  9. arXiv:2110.01537  [pdf, other

    physics.ins-det hep-ex hep-ph nucl-ex

    Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches

    Authors: A. Avasthi, T. W. Bowyer, C. Bray, T. Brunner, N. Catarineu, E. Church, R. Guenette, S. J. Haselschwardt, J. C. Hayes, M. Heffner, S. A. Hertel, P. H. Humble, A. Jamil, S. Kim, R. F. Lang, K. G. Leach, B. G. Lenardo, W. H. Lippincott, A. Marino, D. N. McKinsey, E. H. Miller, D. C. Moore, B. Mong, B. Monreal, M. E. Monzani , et al. (9 additional authors not shown)

    Abstract: Large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay ($0νββ$) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas or liquid phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomen… ▽ More

    Submitted 21 December, 2021; v1 submitted 4 October, 2021; originally announced October 2021.

    Comments: 19 pages, 10 figures; published version

    Journal ref: Phys. Rev. D 104, 112007 (2021)

  10. arXiv:2109.11487  [pdf, other

    physics.ins-det hep-ex

    Measurement of Charge and Light Yields for $^{127}$Xe L-Shell Electron Captures in Liquid Xenon

    Authors: Dylan J Temples, Jacob McLaughlin, Jack Bargemann, Daniel Baxter, Amy Cottle, C Eric Dahl, W Hugh Lippincott, Alissa Monte, Jason Phelan

    Abstract: Dark matter searches using dual-phase xenon time-projection chambers (LXe-TPCs) rely on their ability to reject background electron recoils (ERs) while searching for signal-like nuclear recoils (NRs). ER response is typically calibrated using $β$-decay sources, such as tritium, but these calibrations do not characterize events accompanied by an atomic vacancy, as in solar neutrino scatters off inn… ▽ More

    Submitted 14 December, 2021; v1 submitted 23 September, 2021; originally announced September 2021.

    Comments: 15 pages, 14 figures

    Report number: FERMILAB-PUB-21-397-E

    Journal ref: Phys. Rev. D 104, 112001 (2021)

  11. arXiv:2104.13374  [pdf, other

    physics.ins-det nucl-ex

    Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of $^{134}$Xe

    Authors: The LUX-ZEPLIN, Collaboration, :, D. S. Akerib, A. K. Al Musalhi, S. K. Alsum, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araujo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, J. Bang, J. W. Bargemann, D. Bauer, A. Baxter, P. Beltrame, E. P. Bernard, A. Bernstein, A. Bhatti, A. Biekert , et al. (172 additional authors not shown)

    Abstract: The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity t… ▽ More

    Submitted 22 November, 2021; v1 submitted 26 April, 2021; originally announced April 2021.

    Comments: Version accepted for publication in Phys. Rev. C

  12. arXiv:2101.08785  [pdf, other

    hep-ex hep-ph nucl-ex physics.ins-det

    Physics reach of a low threshold scintillating argon bubble chamber in coherent elastic neutrino-nucleus scattering reactor experiments

    Authors: L. J. Flores, Eduardo Peinado, E. Alfonso-Pita, K. Allen, M. Baker, E. Behnke, M. Bressler, K. Clark, R. Coppejans, C. Cripe, M. Crisler, C. E. Dahl, A. de St. Croix, D. Durnford, P. Giampa, O. Harris, P. Hatch, H. Hawley, C. M. Jackson, Y. Ko, C. Krauss, N. Lamb, M. Laurin, I. Levine, W. H. Lippincott , et al. (9 additional authors not shown)

    Abstract: The physics reach of a low threshold (100 eV) scintillating argon bubble chamber sensitive to Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) from reactor neutrinos is studied. The sensitivity to the weak mixing angle, neutrino magnetic moment, and a light $Z'$ gauge boson mediator are analyzed. A Monte Carlo simulation of the backgrounds is performed to assess their contribution to the sig… ▽ More

    Submitted 26 May, 2021; v1 submitted 21 January, 2021; originally announced January 2021.

    Comments: 9 pages, 5 figures. v2: figures added, minor changes. Matches published version

    Journal ref: Phys. Rev. D 103, 091301 (2021)

  13. arXiv:2101.08753  [pdf, other

    astro-ph.IM physics.ins-det

    Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

    Authors: D. S. Akerib, A. K. Al Musalhi, S. K. Alsum, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, J. Bang, J. W. Bargemann, D. Bauer, A. Baxter, P. Beltrame, E. P. Bernard, A. Bernstein, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, G. M. Blockinger , et al. (162 additional authors not shown)

    Abstract: Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matt… ▽ More

    Submitted 21 January, 2021; originally announced January 2021.

    Comments: 14 pages, 6 figures

  14. arXiv:2006.02506  [pdf, other

    physics.ins-det hep-ex

    The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, S. Aviles, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame, J. Bensinger , et al. (365 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent… ▽ More

    Submitted 28 February, 2022; v1 submitted 3 June, 2020; originally announced June 2020.

    Comments: 45 pages (79 inc. tables), 7 figures, 9 tables

    Journal ref: The European Physical Journal C, Volume 80, Article number: 1044 (2020)

  15. Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment

    Authors: The LUX-ZEPLIN Collaboration, :, D. S. Akerib, C. W. Akerlof, A. Alqahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, J. Bang, D. Bauer, A. Baxter, J. Bensinger, E. P. Bernard, A. Bernstein, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, K. E. Boast , et al. (173 additional authors not shown)

    Abstract: The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of par… ▽ More

    Submitted 23 June, 2020; v1 submitted 25 January, 2020; originally announced January 2020.

    Comments: 24 pages, 19 figures; Corresponding Authors: A. Cottle, V. Kudryavtsev, D. Woodward

  16. arXiv:1910.09124  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    The LUX-ZEPLIN (LZ) Experiment

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, J. Barthel, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame , et al. (357 additional authors not shown)

    Abstract: We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n… ▽ More

    Submitted 3 November, 2019; v1 submitted 20 October, 2019; originally announced October 2019.

  17. arXiv:1905.12522  [pdf, ps, other

    physics.ins-det astro-ph.CO hep-ex hep-ph

    Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, S. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, R. Filgas , et al. (54 additional authors not shown)

    Abstract: The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by… ▽ More

    Submitted 25 November, 2020; v1 submitted 29 May, 2019; originally announced May 2019.

    Comments: 18 pages, 12 figures

    Journal ref: Phys. Rev. D 100, 082006 (2019)

  18. Measurement of the Gamma Ray Background in the Davis Cavern at the Sanford Underground Research Facility

    Authors: D. S. Akerib, C. W. Akerlof, S. K. Alsum, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, A. Baxter, E. P. Bernard, A. Biekert, T. P. Biesiadzinski, K. E. Boast, B. Boxer, P. Brás, J. H. Buckley, V. V. Bugaev, S. Burdin, J. K. Busenitz, C. Carels, D. L. Carlsmith, M. C. Carmona-Benitez, M. Cascella , et al. (142 additional authors not shown)

    Abstract: Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located with… ▽ More

    Submitted 14 November, 2019; v1 submitted 3 April, 2019; originally announced April 2019.

    Comments: 11 pages, 9 figures

    Journal ref: Astroparticle Physics, Volume 116, Pages 102391 (2020)

  19. arXiv:1902.04031  [pdf, other

    astro-ph.CO hep-ex physics.ins-det

    Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis, R. Filgas , et al. (47 additional authors not shown)

    Abstract: Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total backgr… ▽ More

    Submitted 11 February, 2019; originally announced February 2019.

    Comments: 9 pages, 8 figures

    Journal ref: Phys. Rev. D 100, 022001 (2019)

  20. arXiv:1811.11308  [pdf, other

    physics.comp-ph physics.ins-det

    Develo** a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning

    Authors: B. Matusch, C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, M. Bressler, B. Broerman, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, C. B. Coutu, C. Cowles, M. Crisler, G. Crowder, N. A. Cruz-Venegas, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis , et al. (48 additional authors not shown)

    Abstract: The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually develo** a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing… ▽ More

    Submitted 27 November, 2018; originally announced November 2018.

    Comments: 27 pages, 10 figures

  21. arXiv:1802.06039  [pdf, other

    astro-ph.IM astro-ph.CO hep-ex physics.ins-det

    Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment

    Authors: D. S. Akerib, C. W. Akerlof, S. K. Alsum, H. M. Araújo, M. Arthurs, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, D. Bauer, J. Belle, P. Beltrame, T. Benson, E. P. Bernard, T. P. Biesiadzinski, K. E. Boast, B. Boxer, P. Brás, J. H. Buckley, V. V. Bugaev, S. Burdin, J. K. Busenitz, C. Carels, D. L. Carlsmith, B. Carlson , et al. (153 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up… ▽ More

    Submitted 2 December, 2019; v1 submitted 16 February, 2018; originally announced February 2018.

    Comments: 14 pages, 11 figures

    Journal ref: Phys. Rev. D 101, 052002 (2020)

  22. arXiv:1703.09144  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Technical Design Report

    Authors: B. J. Mount, S. Hans, R. Rosero, M. Yeh, C. Chan, R. J. Gaitskell, D. Q. Huang, J. Makkinje, D. C. Malling, M. Pangilinan, C. A. Rhyne, W. C. Taylor, J. R. Verbus, Y. D. Kim, H. S. Lee, J. Lee, D. S. Leonard, J. Li, J. Belle, A. Cottle, W. H. Lippincott, D. J. Markley, T. J. Martin, M. Sarychev, T. E. Tope , et al. (237 additional authors not shown)

    Abstract: In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.

    Submitted 27 March, 2017; originally announced March 2017.

    Comments: 392 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Numbers Two and Three (CD-2 and CD-3) management processes. Report also available by chapter at <a href="http://hep.ucsb.edu/LZ/TDR/">this URL</a>

    Report number: LBNL-1007256

  23. arXiv:1702.07666  [pdf, ps, other

    astro-ph.CO hep-ex physics.ins-det

    Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, P. Campion, G. Cao, C. J. Chen, U. Chowdhury, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, G. Crowder, C. E. Dahl, M. Das, S. Fallows, J. Farine, I. Felis, R. Filgas, F. Girard , et al. (37 additional authors not shown)

    Abstract: New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less th… ▽ More

    Submitted 2 August, 2017; v1 submitted 24 February, 2017; originally announced February 2017.

    Comments: 6 pages, 6 figures

    Journal ref: Phys. Rev. Lett. 118, 251301 (2017)

  24. Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, I. J. Arnquist, M. Arthurs, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, J. Belle, P. Beltrame, T. Benson, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. Bolozdynya, B. Boxer, R. Bramante, P. Brás, J. H. Buckley, V. V. Bugaev , et al. (180 additional authors not shown)

    Abstract: The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,… ▽ More

    Submitted 26 September, 2017; v1 submitted 8 February, 2017; originally announced February 2017.

    Comments: 13 pages, 3 figures, accepted for publication in Astroparticle Physics

  25. arXiv:1603.02290  [pdf

    physics.ins-det hep-ex

    Near-infrared scintillation of liquid argon

    Authors: T. Alexander, C. O. Escobar, W. H. Lippincott, P. Rubinov

    Abstract: Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $μ$m < $λ$; < 1.5$μ$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show en… ▽ More

    Submitted 7 March, 2016; originally announced March 2016.

    Comments: 9 pages, 7 figures, contribution to the proceedings of the conference Light Detection in Noble Elements (LIDINE 2015)

    Journal ref: JINST 11 C03010 (2016)

  26. arXiv:1601.03729  [pdf, other

    astro-ph.CO physics.ins-det

    Improved dark matter search results from PICO-2L Run 2

    Authors: C. Amole, M. Ardid, I. J. Arnquist, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, M. Das, F. Debris, S. Fallows, J. Farine, I. Felis, R. Filgas, M. Fines-Neuschild, F. Girard, G. Giroux , et al. (33 additional authors not shown)

    Abstract: New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nu… ▽ More

    Submitted 25 March, 2016; v1 submitted 14 January, 2016; originally announced January 2016.

    Journal ref: Phys. Rev. D 93, 061101 (2016)

  27. arXiv:1510.07754  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber

    Authors: C. Amole, M. Ardid, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, S. Daley, M. Das, F. Debris, N. Dhungana, J. Farine, I. Felis, R. Filgas, F. Girard, G. Giroux, A. Grandison , et al. (34 additional authors not shown)

    Abstract: New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays… ▽ More

    Submitted 3 March, 2016; v1 submitted 26 October, 2015; originally announced October 2015.

    Comments: v3 to reflect published version

    Journal ref: Phys. Rev. D 93, 052014 (2016)

  28. arXiv:1509.02910  [pdf

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Conceptual Design Report

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, P. Bauer, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. I. Bolozdynya, E. M. Boulton, R. Bramante, J. H. Buckley, V. V. Bugaev, R. Bunker, S. Burdin, J. K. Busenitz , et al. (170 additional authors not shown)

    Abstract: The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp… ▽ More

    Submitted 23 September, 2015; v1 submitted 9 September, 2015; originally announced September 2015.

    Comments: 278 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Number One (CD-1) management process. Report also available by chapter at http://hep.ucsb.edu/LZ/CDR. This version includes corrections of minor typographic errors

    Report number: LBNL-190005

  29. Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

    Authors: **gke Xu, Emily Shields, Frank Calaprice, Shawn Westerdale, Francis Froborg, Burkhant Suerfu, Thomas Alexander, Ani Aprahamian, Henning O. Back, Clark Casarella, Xiao Fang, Yogesh K. Gupta, Aldo Ianni, Edward Lamere, W. Hugh Lippincott, Qian Liu, Stephanie Lyons, Kevin Siegl, Mallory Smith, Wanpeng Tan, Bryant Vande Kolk

    Abstract: The dark matter interpretation of the DAMA modulation signal depends on the NaI(Tl) scintillation efficiency of nuclear recoils. Previous measurements for Na recoils have large discrepancies, especially in the DAMA/LIBRA modulation energy region. We report a quenching effect measurement of Na recoils in NaI(Tl) from 3keV$_{\text{nr}}$ to 52keV$_{\text{nr}}$, covering the whole DAMA/LIBRA energy re… ▽ More

    Submitted 24 March, 2015; originally announced March 2015.

    Journal ref: Phys. Rev. C 92, 015807 (2015)

  30. arXiv:1503.00008  [pdf, other

    astro-ph.CO physics.ins-det

    Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber

    Authors: C. Amole, M. Ardid, D. M. Asner, D. Baxter, E. Behnke, P. Bhattacharjee, H. Borsodi, M. Bou-Cabo, S. J. Brice, D. Broemmelsiek, K. Clark, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, S. Daley, M. Das, F. Debris, N. Dhungana, J. Farine, I. Felis, R. Filgas, M. Fines-Neuschild, F. Girard, G. Giroux , et al. (32 additional authors not shown)

    Abstract: New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation o… ▽ More

    Submitted 29 June, 2015; v1 submitted 27 February, 2015; originally announced March 2015.

    Comments: 6 pages, 6 figures, v2 to match published version

    Journal ref: Phys. Rev. Lett. 114, 231302 (2015)

  31. arXiv:1406.4825  [pdf, other

    physics.ins-det hep-ex

    Measurement of Scintillation and Ionization Yield and Scintillation Pulse Shape from Nuclear Recoils in Liquid Argon

    Authors: H. Cao, T. Alexander, A. Aprahamian, R. Avetisyan, H. O. Back, A. G. Cocco, F. DeJongh, G. Fiorillo, C. Galbiati, L. Grandi, Y. Guardincerri, C. Kendziora, W. H. Lippincott, C. Love, S. Lyons, L. Manenti, C. J. Martoff, Y. Meng, D. Montanari, P. Mosteiro, D. Olvitt, S. Pordes, H. Qian, B. Rossi, R. Saldanha , et al. (10 additional authors not shown)

    Abstract: We have measured the scintillation and ionization yield of recoiling nuclei in liquid argon as a function of applied electric field by exposing a dual-phase liquid argon time projection chamber (LAr-TPC) to a low energy pulsed narrow band neutron beam produced at the Notre Dame Institute for Structure and Nuclear Astrophysics. Liquid scintillation counters were arranged to detect and identify neut… ▽ More

    Submitted 27 May, 2015; v1 submitted 18 June, 2014; originally announced June 2014.

    Comments: v2 to reflect published version

    Journal ref: Phys. Rev. D 91, 092007 (2015)

  32. Pulse-shape discrimination and energy resolution of a liquid-argon scintillator with xenon do**

    Authors: Christopher G. Wahl, Ethan P. Bernard, W. Hugh Lippincott, James A. Nikkel, Yunchang Shin, Daniel N. McKinsey

    Abstract: Liquid-argon scintillation detectors are used in fundamental physics experiments and are being considered for security applications. Previous studies have suggested that the addition of small amounts of xenon dopant improves performance in light or signal yield, energy resolution, and particle discrimination. In this study, we investigate the detector response for xenon dopant concentrations from… ▽ More

    Submitted 20 April, 2014; v1 submitted 3 March, 2014; originally announced March 2014.

    Journal ref: JINST 9 P06013

  33. arXiv:1310.8327  [pdf, other

    hep-ex astro-ph.CO astro-ph.HE astro-ph.IM physics.ins-det

    Snowmass CF1 Summary: WIMP Dark Matter Direct Detection

    Authors: P. Cushman, C. Galbiati, D. N. McKinsey, H. Robertson, T. M. P. Tait, D. Bauer, A. Borgland, B. Cabrera, F. Calaprice, J. Cooley, T. Empl, R. Essig, E. Figueroa-Feliciano, R. Gaitskell, S. Golwala, J. Hall, R. Hill, A. Hime, E. Hoppe, L. Hsu, E. Hungerford, R. Jacobsen, M. Kelsey, R. F. Lang, W. H. Lippincott , et al. (24 additional authors not shown)

    Abstract: As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter spa… ▽ More

    Submitted 3 November, 2013; v1 submitted 30 October, 2013; originally announced October 2013.

    Comments: Snowmass CF1 Final Summary Report: 47 pages and 28 figures with a 5 page appendix on instrumentation R&D

  34. arXiv:1306.5675  [pdf, other

    physics.ins-det hep-ex

    Observation of the Dependence of Scintillation from Nuclear Recoils in Liquid Argon on Drift Field

    Authors: T. Alexander, H. O. Back, H. Cao, A. G. Cocco, F. DeJongh, G. Fiorillo, C. Galbiati, C. Ghag, L. Grandi, C. Kendziora, W. H. Lippincott, B. Loer, C. Love, L. Manenti, C. J. Martoff, Y. Meng, D. Montanari, P. Mosteiro, D. Olvitt, S. Pordes, H. Qian, B. Rossi, R. Saldanha, W. Tan, J. Tatarowicz , et al. (5 additional authors not shown)

    Abstract: We have exposed a dual-phase Liquid Argon Time Projection Chamber (LAr-TPC) to a low energy pulsed narrowband neutron beam, produced at the Notre Dame Institute for Structure and Nuclear Astrophysics to study the scintillation light yield of recoiling nuclei in a LAr-TPC. A liquid scintillation counter was arranged to detect and identify neutrons scattered in the LAr-TPC target and to select the e… ▽ More

    Submitted 16 December, 2013; v1 submitted 24 June, 2013; originally announced June 2013.

    Comments: v3 updated to reflect published version, including a set of plots for 49.9 keV data

    Journal ref: Phys. Rev. D 88, 092006 (2013)

  35. arXiv:1304.6001  [pdf, other

    physics.ins-det astro-ph.CO hep-ex

    Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber

    Authors: COUPP Collaboration, E. Behnke, T. Benjamin, S. J. Brice, D. Broemmelsiek, J. I. Collar, P. S. Cooper, M. Crisler, C. E. Dahl, D. Fustin, J. Hall, C. Harnish, I. Levine, W. H. Lippincott, T. Moan, T. Nania, R. Neilson, E. Ramberg, A. E. Robinson, A. Sonnenschein, E. Vázquez-Jáuregui, R. A. Rivera, L. Uplegger

    Abstract: We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel… ▽ More

    Submitted 31 January, 2014; v1 submitted 22 April, 2013; originally announced April 2013.

    Comments: 5 pages, 3 figures

    Report number: FERMILAB-PUB-10-318-A-CD-E

    Journal ref: Phys. Rev. D 88, 021102 (2013)

  36. arXiv:1211.0909  [pdf, other

    astro-ph.IM nucl-ex physics.ins-det

    Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector

    Authors: P. -A. Amaudruz, M. Batygov, B. Beltran, K. Boudjemline, M. G. Boulay B. Cai T. Caldwell, M. Chen, R. Chouinard, B. T. Cleveland, D. Contreras, K. Dering, F. Duncan, R. Ford, R. Gagnon F. Giuliani, M. Gold V. V. Golovko, P. Gorel, K. Graham, D. R. Grant, R. Hakobyan, A. L. Hallin, P. Harvey, C. Hearns, C. J. Jillings, M. Kuźniak, I. Lawson, O. Li , et al. (27 additional authors not shown)

    Abstract: The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction.… ▽ More

    Submitted 23 April, 2014; v1 submitted 5 November, 2012; originally announced November 2012.

    Journal ref: Astroparticle Physics 62, 178-194 (2015)

  37. arXiv:1111.3260  [pdf, ps, other

    nucl-ex astro-ph.IM physics.ins-det

    Scintillation yield and time dependence from electronic and nuclear recoils in liquid neon

    Authors: W. H. Lippincott, K. J. Coakley, D. Gastler, E. Kearns, D. N. McKinsey, J. A. Nikkel

    Abstract: We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear recoil energy. We also measure the \leff\, parameter in liquid neon between 30 and 370 keV nuclear recoil energ… ▽ More

    Submitted 13 August, 2012; v1 submitted 14 November, 2011; originally announced November 2011.

    Comments: 18 pages, 23 figures, v2 updated to reflect published version

    Journal ref: Physics Review C, 86, 015807 (2012)

  38. arXiv:1004.0373  [pdf, ps, other

    physics.ins-det astro-ph.IM nucl-ex

    Measurement of scintillation efficiency for nuclear recoils in liquid argon

    Authors: D. Gastler, E. Kearns, A. Hime, L. C. Stonehill, S. Seibert, J. Klein, W. H. Lippincott, D. N. McKinsey, J. A. Nikkel

    Abstract: The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the nuclear recoil scintillation response to the electronic recoil response, is 0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.

    Submitted 8 May, 2012; v1 submitted 2 April, 2010; originally announced April 2010.

    Comments: revision 2

  39. arXiv:0709.1880  [pdf, ps, other

    nucl-ex astro-ph physics.atom-ph

    Detection and Imaging of He_2 Molecules in Superfluid Helium

    Authors: W. G. Rellergert, S. B. Cahn, A. Garvan, J. C. Hanson, W. H. Lippincott, J. A. Nikkel, D. N. McKinsey

    Abstract: We present data that show a cycling transition can be used to detect and image metastable He$_2$ triplet molecules in superfluid helium. We demonstrate that limitations on the cycling efficiency due to the vibrational structure of the molecule can be mitigated by the use of repum** lasers. Images of the molecules obtained using the method are also shown. This technique gives rise to a new kind… ▽ More

    Submitted 18 December, 2007; v1 submitted 12 September, 2007; originally announced September 2007.

    Comments: 4 pages, 5 figures, content revised

    Journal ref: Phys.Rev.Lett.100:025301,2008

  40. arXiv:nucl-ex/0503006  [pdf, ps, other

    nucl-ex astro-ph physics.atom-ph

    Trace Detection of Metastable Helium Molecules in Superfluid Helium by Laser-Induced Fluorescence

    Authors: D. N. McKinsey, W. H. Lippincott, J. Nikkel, W. Rellergert

    Abstract: We describe an approach to detecting ionizing radiation that combines the special properties of superfluid helium with the sensitivity of quantum optics techniques. Ionization in liquid helium results in the copious production of metastable helium molecules, which can be detected by laser-induced fluorescence. Each molecule can be probed many times using a cycling transition, resulting in the de… ▽ More

    Submitted 11 March, 2005; originally announced March 2005.

    Comments: 10 pages, 2 figures. Submitted to Physical Review Letters

    Journal ref: Phys.Rev.Lett. 95 (2005) 111101