Argon Purification Studies and a Novel Liquid Argon Re-circulation System
Authors:
K. Mavrokoridis,
R. G. Calland,
J. Coleman,
P. K. Lightfoot,
N. McCauley,
K. J. McCormick,
C. Touramanis
Abstract:
Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a comprehensive study of the effects of electronegative impurity on gaseous and liquid argon scintillation light, an analysis of the efficacy of various purificat…
▽ More
Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a comprehensive study of the effects of electronegative impurity on gaseous and liquid argon scintillation light, an analysis of the efficacy of various purification chemicals, as well as the Liverpool LAr setup, which utilises a novel re-circulation purification system. Of the impurities tested - Air, O_2, H_2O, N_2 and CO_2 in the range of between 0.01 ppm to 1000 ppm - H_2O was found to have the most profound effect on gaseous argon scintillation light, and N_2 was found to have the least. Additionally, a correlation between the slow component decay time and the total energy deposited with 0.01 ppm - 100 ppm O_2 contamination levels in liquid argon has been established. The superiority of molecular sieves over anhydrous complexes at absorbing Ar gas, N_2 gas and H_2O vapour has been quantified using BET isotherm analysis. The efficiency of Cu and P_2O5 at removing O_2 and H_2O impurities from 1 bar N6 argon gas at both room temperature and -130 ^oC was investigated and found to be high. A novel, highly scalable LAr re-circulation system has been developed. The complete system, consisting of a motorised bellows pump operating in liquid and a purification cartridge, were designed and built in-house. The system was operated successfully over many days and achieved a re-circulation rate of 27 litres/hour and high purity.
△ Less
Submitted 26 June, 2011;
originally announced June 2011.
-
ArDM: a ton-scale LAr detector for direct Dark Matter searches
Authors:
ArDM Collaboration,
A. Marchionni,
C. Amsler,
A. Badertscher,
V. Boccone,
A. Bueno,
M. C. Carmona-Benitez,
J. Coleman,
W. Creus,
A. Curioni,
M. Daniel,
E. J. Dawe,
U. Degunda,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
P. K. Lightfoot,
D. Lussi,
J. Lozano,
K. Mavrokoridis,
A. Melgarejo
, et al. (19 additional authors not shown)
Abstract:
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr with a charge imaging detector. The ionization charge is extracted from the liquid into the gas phase and there amplified by the use of a Large Electron Multiplier in order to reduc…
▽ More
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr with a charge imaging detector. The ionization charge is extracted from the liquid into the gas phase and there amplified by the use of a Large Electron Multiplier in order to reduce the detection threshold. Direct detection of the ionization charge with fine spatial granularity, combined with a measurement of the amplitude and time evolution of the associated primary scintillation light, provide powerful tools for the identification of WIMP interactions against the background due to electrons, photons and possibly neutrons if scattering more than once. A one ton LAr detector is presently installed on surface at CERN to fully test all functionalities and it will be soon moved to an underground location. We will emphasize here the lessons learned from such a device for the design of a large LAr TPC for neutrino oscillation, proton decay and astrophysical neutrinos searches.
△ Less
Submitted 29 December, 2010;
originally announced December 2010.
-
First results on light readout from the 1-ton ArDM liquid argon detector for dark matter searches
Authors:
C. Amsler,
A. Badertscher,
V. Boccone,
A. Bueno,
M. C. Carmona-Benitez,
W. Creus,
A. Curioni,
M. Daniel,
E. J. Dawe,
U. Degunda,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
P. K. Lightfoot,
D. Lussi,
J. Lozano,
A. Marchionni,
K. Mavrokoridis,
A. Melgarejo,
P. Mijakowski,
G. Natterer
, et al. (16 additional authors not shown)
Abstract:
ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM…
▽ More
ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM on the surface at CERN. With a preliminary and incomplete set of PMTs, the light yield at zero electric field is found to be between 0.3-0.5 phe/keVee depending on the position within the detector volume, confirming our expectations based on smaller detector setups.
△ Less
Submitted 27 October, 2010; v1 submitted 19 September, 2010;
originally announced September 2010.
-
Development of wavelength shifter coated reflectors for the ArDM argon dark matter detector
Authors:
The ArDM Collaboration,
V. Boccone,
P. K. Lightfoot,
K. Mavrokoridis,
C. Regenfus,
C. Amsler,
A. Badertscher,
A. Bueno,
H. Cabrera,
M. C. Carmona-Benitez,
M. Daniel,
E. J. Daw,
U. Degunda,
A. Dell'Antone,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
D. Lussi,
J. Lozano,
A. Marchionni,
A. Melgarejo
, et al. (16 additional authors not shown)
Abstract:
To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were…
▽ More
To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were deposited by spraying and vacuum evaporation onto specular 3M{\small\texttrademark}-foil and diffuse Tetratex{\small\textregistered} (TTX) substrates. Light yields of each reflector and TPB coating combination were compared. Reflection coefficients of TPB coated reflectors were independently measured using a spectroradiometer in a wavelength range between 200 and 650 nm. WLS coating on the PMT window was also studied. These measurements were used to define the parameters of the light reflectors of the ArDM experiment. Fifteen large $120\times 25$ cm$^2$ TTX sheets were coated and assembled in the detector. Measurements in argon gas are reported providing good evidence of fulfilling the light collection requirements of the experiment.
△ Less
Submitted 1 April, 2009;
originally announced April 2009.
-
Optical readout tracking detector concept using secondary scintillation from liquid argon generated by a thick gas electron multiplier
Authors:
P. K. Lightfoot,
G. J. Barker,
K. Mavrokoridis,
Y. A. Ramachers,
N. J. C. Spooner
Abstract:
For the first time secondary scintillation, generated within the holes of a thick gas electron multiplier (TGEM) immersed in liquid argon, has been observed and measured using a silicon photomultiplier device (SiPM). 250 electron-ion pairs, generated in liquid argon via the interaction of a 5.9KeV Fe-55 gamma source, were drifted under the influence of a 2.5KV/cm field towards a 1.5mm thickness…
▽ More
For the first time secondary scintillation, generated within the holes of a thick gas electron multiplier (TGEM) immersed in liquid argon, has been observed and measured using a silicon photomultiplier device (SiPM). 250 electron-ion pairs, generated in liquid argon via the interaction of a 5.9KeV Fe-55 gamma source, were drifted under the influence of a 2.5KV/cm field towards a 1.5mm thickness TGEM, the local field sufficiently high to generate secondary scintillation light within the liquid as the charge traversed the central region of the TGEM hole. The resulting VUV light was incident on an immersed SiPM device coated in the waveshifter tetraphenyl butadiene (TPB), the emission spectrum peaked at 460nm in the high quantum efficiency region of the device. For a SiPM over-voltage of 1V, a TGEM voltage of 9.91KV, and a drift field of 2.5KV/cm, a total of 62 photoelectrons were produced at the SiPM device per Fe-55 event, corresponding to an estimated gain of 150 photoelectrons per drifted electron.
△ Less
Submitted 11 December, 2008;
originally announced December 2008.
-
Characterisation of a silicon photomultiplier device for applications in liquid argon based neutrino physics and dark matter searches
Authors:
P. K. Lightfoot,
G. J. Barker,
K. Mavrokoridis,
Y. A. Ramachers,
N. J. C. Spooner
Abstract:
The performance of a silicon photomultiplier has been assessed at low temperature in order to evaluate its suitability as a scintillation readout device in liquid argon particle physics detectors. The gain, measured as 2.1E6 for a constant over-voltage of 4V was measured between 25degC and -196degC and found to be invariant with temperature, the corresponding single photoelectron dark count rate…
▽ More
The performance of a silicon photomultiplier has been assessed at low temperature in order to evaluate its suitability as a scintillation readout device in liquid argon particle physics detectors. The gain, measured as 2.1E6 for a constant over-voltage of 4V was measured between 25degC and -196degC and found to be invariant with temperature, the corresponding single photoelectron dark count rate reducing from 1MHz to 40Hz respectively. Following multiple thermal cycles no deterioration in the device performance was observed. The photon detection efficiency (PDE) was assessed as a function of photon wavelength and temperature. For an over-voltage of 4V, the PDE, found again to be invariant with temperature, was measured as 25% for 460nm photons and 11% for 680nm photons. Device saturation due to high photon flux rate, observed both at room temperature and -196degC, was again found to be independent of temperature. Although the output signal remained proportional to the input signal so long as the saturation limit was not exceeded, the photoelectron pulse resolution and decay time increased slightly at -196degC.
△ Less
Submitted 6 August, 2008; v1 submitted 21 July, 2008;
originally announced July 2008.
-
First measurement of low intensity fast neutron background from rock at the Boulby Underground Laboratory
Authors:
E. Tziaferi,
M. J. Carson,
V. A. Kudryavtsev,
R. Lerner,
P. K. Lightfoot,
S. M. Paling,
M. Robinson,
N. J. C. Spooner
Abstract:
A technique to measure low intensity fast neutron flux has been developed. The design, calibrations, procedure for data analysis and interpretation of the results are discussed in detail. The technique has been applied to measure the neutron background from rock at the Boulby Underground Laboratory, a site used for dark matter and other experiments, requiring shielding from cosmic ray muons. The…
▽ More
A technique to measure low intensity fast neutron flux has been developed. The design, calibrations, procedure for data analysis and interpretation of the results are discussed in detail. The technique has been applied to measure the neutron background from rock at the Boulby Underground Laboratory, a site used for dark matter and other experiments, requiring shielding from cosmic ray muons. The experiment was performed using a liquid scintillation detector. A 6.1 litre volume stainless steel cell was filled with an in-house made liquid scintillator loaded with Gd to enhance neutron capture. A two-pulse signature (proton recoils followed by gammas from neutron capture) was used to identify the neutron events from much larger gamma background from PMTs. Suppression of gammas from the rock was achieved by surrounding the detector with high-purity lead and copper. Calibrations of the detector were performed with various gamma and neutron sources. Special care was taken to eliminate PMT afterpulses and correlated background events from the delayed coincidences of two pulses in the Bi-Po decay chain. A four month run revealed a neutron-induced event rate of 1.84 +- 0.65 (stat.) events/day. Monte Carlo simulations based on the GEANT4 toolkit were carried out to estimate the efficiency of the detector and the energy spectra of the expected proton recoils. From comparison of the measured rate with Monte Carlo simulations the flux of fast neutrons from rock was estimated as (1.72 +- 0.61 (stat.) +- 0.38 (syst.))*10^(-6) cm^(-2) s^(-1) above 0.5 MeV.
△ Less
Submitted 8 December, 2006;
originally announced December 2006.
-
A two-phase argon avalanche detector operated in a single electron counting mode
Authors:
A. Bondar,
A. Buzulutskov,
A. Grebenuk,
D. Pavlyuchenko,
R. Snopkov,
Y. Tikhonov,
V. A. Kudryavtsev,
P. K. Lightfoot,
N. J. C. Spooner
Abstract:
The performance of a two-phase Ar avalanche detector in a single electron counting mode was studied, with regard to potential application in coherent neutrino-nucleus scattering and dark matter search experiments. The detector comprised of a 1 cm thick liquid Ar layer and a triple-GEM multiplier operated in the saturated vapour above the liquid phase. Successful operation of the detector in sing…
▽ More
The performance of a two-phase Ar avalanche detector in a single electron counting mode was studied, with regard to potential application in coherent neutrino-nucleus scattering and dark matter search experiments. The detector comprised of a 1 cm thick liquid Ar layer and a triple-GEM multiplier operated in the saturated vapour above the liquid phase. Successful operation of the detector in single electron counting mode, in the gain range from 6000 to 40000, has for the first time been demonstrated.
△ Less
Submitted 7 November, 2006;
originally announced November 2006.
-
Reduction of Coincident Photomultiplier Noise Relevant to Astroparticle Physics Experiment
Authors:
M. Robinson,
P. K. Lightfoot,
M. J. Carson,
V. A. Kudryavtsev,
N. J. C. Spooner
Abstract:
In low background and low threshold particle astrophysics experiments using observation of Cherenkov or scintillation light it is common to use pairs or arrays of photomultipliers operated in coincidence. In such circumstances, for instance in dark matter and neutrino experiments, unexpected PMT noise events have been observed, probably arising from generation of light from one PMT being detecte…
▽ More
In low background and low threshold particle astrophysics experiments using observation of Cherenkov or scintillation light it is common to use pairs or arrays of photomultipliers operated in coincidence. In such circumstances, for instance in dark matter and neutrino experiments, unexpected PMT noise events have been observed, probably arising from generation of light from one PMT being detected by one or more other PMTs. We describe here experimental investigation of such coincident noise events and development of new techniques to remove them using novel pulse shape discrimination procedures. When applied to data from a low background NaI detector with facing PMTs the new procedures are found to improve noise rejection by a factor of 20 over conventional techniques, with significantly reduced loss of signal events.
△ Less
Submitted 5 March, 2005;
originally announced March 2005.