Study of collision and $γ$-cascade times following neutron-capture processes in cryogenic detectors
Authors:
CRAB collaboration,
G. Soum-Sidikov,
H. Abele,
J. Burkhart,
F. Cappella,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
J-P. Crocombette,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
E. Dumonteil,
A. Erhart,
A. Giuliani,
C. Goupy,
F. Gunsing,
E. Jericha,
M. Kaznacheeva,
A. Kinast,
H. Kluck,
A. Langenkämper,
T. Lasserre
, et al. (25 additional authors not shown)
Abstract:
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay betwe…
▽ More
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay between the development in time of the de-excitation $γ$-cascade of the target nucleus and that of the associated atomic collisions in matter. We present detailed simulations coupling the FIFRELIN code for the description of the $γ$-cascades and the IRADINA code for the modelling of the fast atomic movements in matter. Nuclear recoil spectra are predicted, and made available to the community, for concrete cases of Al$_2$O$_3$, Si, Ge and CaWO$_4$ crystals exposed to a low intensity beam of thermal neutrons. We find that timing effects cause new calibration peaks to emerge in the recoil spectra and also impact the shape of the continuous recoil distribution. We discuss how they could give access to a rich physics program, spanning the accurate study of the response of cryogenic detectors in the sub-keV range, tests of solid state physics simulations and tests of nuclear models.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Observation of a nuclear recoil peak at the 100 eV scale induced by neutron capture
Authors:
CRAB Collaboration,
NUCLEUS Collaboration,
H. Abele,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
I. Colantoni,
J. -P. Crocombette,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
D. Desforge,
A. Doblhammer,
E. Dumonteil,
S. Dorer,
A. Erhart,
A. Fuss,
M. Friedl,
A. Garai
, et al. (53 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact…
▽ More
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact moderator. The measured spectrum is found in agreement with simulations and the expected peak structure from the single-$γ$ de-excitation of $^{183}$W is identified with 3 $σ$ significance. This result demonstrates a new method for precise, in-situ, and non-intrusive calibration of low-threshold experiments.
△ Less
Submitted 2 June, 2023; v1 submitted 7 November, 2022;
originally announced November 2022.
-
The Double Chooz antineutrino detectors
Authors:
Double Chooz Collaboration,
H. de Kerret,
Y. Abe,
C. Aberle,
T. Abrahão,
J. M. Ahijado,
T. Akiri,
J. M. Alarcón,
J. Alba,
H. Almazan,
J. C. dos Anjos,
S. Appel,
F. Ardellier,
I. Barabanov,
J. C. Barriere,
E. Baussan,
A. Baxter,
I. Bekman,
M. Bergevin,
A. Bernstein,
W. Bertoli,
T. J. C. Bezerra,
L. Bezrukov,
C. Blanco,
N. Bleurvacq
, et al. (226 additional authors not shown)
Abstract:
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in th…
▽ More
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.
△ Less
Submitted 13 September, 2022; v1 submitted 31 January, 2022;
originally announced January 2022.
-
Neutron availability in the Complementary Experiments Hall of the IFMIF-DONES facility
Authors:
Jason Hirtz,
Alain Letourneau,
Loïc Thulliez,
Angel Ibarra,
Wojciech Krolas,
Adam Maj
Abstract:
The IFMIF-DONES facility will be dedicated to the irradiation of structural materials planned for the use in future fusion reactors such as DEMO (Demonstration Fusion Power Plant). The potentialities of the IFMIF-DONES facility to complement its principal purpose by other experiments that would open the facility to other communities is addressed in this work. It concerns a study based on simulatio…
▽ More
The IFMIF-DONES facility will be dedicated to the irradiation of structural materials planned for the use in future fusion reactors such as DEMO (Demonstration Fusion Power Plant). The potentialities of the IFMIF-DONES facility to complement its principal purpose by other experiments that would open the facility to other communities is addressed in this work. It concerns a study based on simulations to evaluate the neutronic performances of IFMIF-DONES in an hall dedicated to complementary experiments where neutrons can be transported. With the simple beam tube geometry of 4.5~cm entrance diameter studied in this work we have shown that a collimated fast-neutron beam of about 2~10$^{10}$~n/cm$^2$/s is available in the hall. Adding a moderator in the hall with neutron extraction lines would allow to get thermal neutron beams of about ~10$^{6}$-10$^{7}$~n/cm$^2$/s for dedicated experiments. The results show that IFMIF-DONES has the potentialities to be a medium-flux neutron facility for most of the neutron applications.
△ Less
Submitted 21 January, 2022;
originally announced January 2022.
-
Stop** power of fission fragments in thin Mylar and nickel foils
Authors:
T. Materna,
E. Berthoumieux,
Q. Deshayes,
D. Doré,
M. Kebbiri,
A. Letourneau,
L. Thulliez,
Y. H. Kim,
U. Köster,
X. Ledoux
Abstract:
The energy loss of heavy ions in thin Mylar and nickel foils was measured accurately using fission fragments from $^{239}Pu(n_{th},f)$, mass and energy separated by the Lohengrin separator at ILL. The detection setup, placed at the focal plane of the Lohengrin separator enabled to measure precisely the kinetic energy difference of selected fragments after passing through the sample. From these dat…
▽ More
The energy loss of heavy ions in thin Mylar and nickel foils was measured accurately using fission fragments from $^{239}Pu(n_{th},f)$, mass and energy separated by the Lohengrin separator at ILL. The detection setup, placed at the focal plane of the Lohengrin separator enabled to measure precisely the kinetic energy difference of selected fragments after passing through the sample. From these data, the stop** powers in Mylar and nickel layers were extracted and compared to calculations. Whereas large deviations are observed with SRIM-2013 for Mylar, fairly good agreements are obtained with the semi-empirical approach of Knyazheva et al. and the calculations contained within the DPASS database. In nickel, SRIM-2013 and Knyazheva model are in agreement with our data within about 10 %, while large deviations are observed with DPASS. We used our data to provide updated parameters for the Knyazheva et al. model and rescale DPASS database for nickel and Mylar.
△ Less
Submitted 4 May, 2021;
originally announced May 2021.
-
Calibration of nuclear recoils at the 100 eV scale using neutron capture
Authors:
L. Thulliez,
D. Lhuillier,
F. Cappella,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
E. Dumonteil,
A. Erhart,
A. Giuliani,
F. Gunsing,
E. Jericha,
M. Kaznacheeva,
A. Kinast,
A. Langenkämper,
T. Lasserre,
A. Letourneau,
O. Litaize,
P. de Marcillac,
S. Marnieros,
T. Materna,
B. Mauri,
E. Mazzucato,
C. Nones,
T. Ortmann
, et al. (12 additional authors not shown)
Abstract:
The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear recoils resulting from the $γ$ emission following thermal neutron capture. In particular, several MeV-scale single-$γ$ transitions induce well-defined nuclear…
▽ More
The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear recoils resulting from the $γ$ emission following thermal neutron capture. In particular, several MeV-scale single-$γ$ transitions induce well-defined nuclear recoil peaks in the 100 eV range. Using the FIFRELIN code, complete schemes of $γ$-cascades for various isotopes can be predicted with high accuracy to determine the continuous background of nuclear recoils below the calibration peaks. We present a comprehensive experimental concept for the calibration of CaWO$_4$ and Ge cryogenic detectors at a research reactor. For CaWO$_4$ the simulations show that two nuclear recoil peaks at 112.5 eV and 160.3 eV should be visible above background simply in the spectrum of the cryogenic detector. Then we discuss how the additional tagging for the associated $γ$ increases the sensitivity of the method and extends its application to a wider energy range and to Ge cryogenic detectors.
△ Less
Submitted 23 May, 2021; v1 submitted 27 November, 2020;
originally announced November 2020.
-
First antineutrino energy spectrum from $^{235}$U fissions with the STEREO detector at ILL
Authors:
STEREO collaboration,
H. Almazán,
L. Bernard,
A. Blanchet,
A. Bonhomme,
C. Buck,
P. del Amo Sanchez,
I. El Atmani,
L. Labit,
J. Lamblin,
A. Letourneau,
D. Lhuillier,
M. Licciardi,
M. Lindner,
T. Materna,
H. Pessard,
J. -S. Réal,
J. -S. Ricol,
C. Roca,
R. Rogly,
T. Salagnac,
V. Savu,
S. Schoppmann,
V. Sergeyeva,
T. Soldner
, et al. (2 additional authors not shown)
Abstract:
This article reports the measurement of the $^{235}$U-induced antineutrino spectrum shape by the STEREO experiment. 43'000 antineutrinos have been detected at about 10 m from the highly enriched core of the ILL reactor during 118 full days equivalent at nominal power. The measured inverse beta decay spectrum is unfolded to provide a pure $^{235}$U spectrum in antineutrino energy. A careful study o…
▽ More
This article reports the measurement of the $^{235}$U-induced antineutrino spectrum shape by the STEREO experiment. 43'000 antineutrinos have been detected at about 10 m from the highly enriched core of the ILL reactor during 118 full days equivalent at nominal power. The measured inverse beta decay spectrum is unfolded to provide a pure $^{235}$U spectrum in antineutrino energy. A careful study of the unfolding procedure, including a cross-validation by an independent framework, has shown that no major biases are introduced by the method. A significant local distortion is found with respect to predictions around $E_ν\simeq 5.3$ MeV. A gaussian fit of this local excess leads to an amplitude of $A = 12.1 \pm 3.4\%$ (3.5$σ$).
△ Less
Submitted 4 June, 2021; v1 submitted 5 October, 2020;
originally announced October 2020.
-
Accurate Measurement of the Electron Antineutrino Yield of U-235 Fissions from the STEREO Experiment with 119 Days of Reactor-On Data
Authors:
STEREO Collaboration,
H. Almazán,
L. Bernard,
A. Blanchet,
A. Bonhomme,
C. Buck,
P. del Amo Sanchez,
I. El Atmani,
J. Haser,
L. Labit,
J. Lamblin,
A. Letourneau,
D. Lhuillier,
M. Licciardi,
M. Lindner,
T. Materna,
A. Minotti,
A. Onillon,
H. Pessard,
J. -S. Réal,
C. Roca,
R. Rogly,
T. Salagnac,
V. Savu,
S. Schoppmann
, et al. (4 additional authors not shown)
Abstract:
We report a measurement of the antineutrino rate from the fission of U-235 with the STEREO detector using 119 days of reactor turned on. In our analysis, we perform several detailed corrections and achieve the most precise single measurement at reactors with highly enriched U-235 fuel. We measure an IBD cross section per fission of $σ_f$ = (6.34 $\pm$ 0.06 [stat] $\pm$ 0.15 [sys] $\pm$ 0.15 [model…
▽ More
We report a measurement of the antineutrino rate from the fission of U-235 with the STEREO detector using 119 days of reactor turned on. In our analysis, we perform several detailed corrections and achieve the most precise single measurement at reactors with highly enriched U-235 fuel. We measure an IBD cross section per fission of $σ_f$ = (6.34 $\pm$ 0.06 [stat] $\pm$ 0.15 [sys] $\pm$ 0.15 [model]) $\times$ 10${}^{-43}$ cm${}^{2}$/fission and observe a rate deficit of (5.2 $\pm$ 0.8 [stat] $\pm$ 2.3 [sys] $\pm$ 2.3 [model])% compared to the model, consistent with the deficit of the world average. Testing U-235 as the sole source of the deficit, we find a tension between the results of lowly and highly enriched U-235 fuel of 2.1 standard deviations.
△ Less
Submitted 10 November, 2020; v1 submitted 8 April, 2020;
originally announced April 2020.
-
Improved Sterile Neutrino Constraints from the STEREO Experiment with 179 Days of Reactor-On Data
Authors:
STEREO Collaboration,
H. Almazán,
L. Bernard,
A. Blanchet,
A. Bonhomme,
C. Buck,
P. del Amo Sanchez,
I. El Atmani,
J. Haser,
F. Kandzia,
S. Kox,
L. Labit,
J. Lamblin,
A. Letourneau,
D. Lhuillier,
M. Licciardi,
M. Lindner,
T. Materna,
A. Minotti,
H. Pessard,
J. -S. Réal,
C. Roca,
R. Rogly,
T. Salagnac,
V. Savu
, et al. (5 additional authors not shown)
Abstract:
The STEREO experiment is a very short baseline reactor antineutrino experiment. It is designed to test the hypothesis of light sterile neutrinos being the cause of a deficit of the observed antineutrino interaction rate at short baselines with respect to the predicted rate, known as the reactor antineutrino anomaly. The STEREO experiment measures the antineutrino energy spectrum in six identical d…
▽ More
The STEREO experiment is a very short baseline reactor antineutrino experiment. It is designed to test the hypothesis of light sterile neutrinos being the cause of a deficit of the observed antineutrino interaction rate at short baselines with respect to the predicted rate, known as the reactor antineutrino anomaly. The STEREO experiment measures the antineutrino energy spectrum in six identical detector cells covering baselines between 9 and 11 m from the compact core of the ILL research reactor. In this article, results from 179 days of reactor turned on and 235 days of reactor turned off are reported at a high degree of detail. The current results include improvements in the modelling of detector optical properties and the gamma-cascade after neutron captures by gadolinium, the treatment of backgrounds, and the statistical method of the oscillation analysis. Using a direct comparison between antineutrino spectra of all cells, largely independent of any flux prediction, we find the data compatible with the null oscillation hypothesis. The best-fit point of the reactor antineutrino anomaly is rejected at more than 99.9% C.L.
△ Less
Submitted 9 September, 2020; v1 submitted 13 December, 2019;
originally announced December 2019.
-
Improved STEREO simulation with a new gamma ray spectrum of excited gadolinium isotopes using FIFRELIN
Authors:
H. Almazán,
L. Bernard,
A. Blanchet,
A. Bonhomme,
C. Buck,
A. Chebboubi,
P. del Amo Sanchez,
I. El Atmani,
J. Haser,
F. Kandzia,
S. Kox,
L. Labit,
J. Lamblin,
A. Letourneau,
D. Lhuillier,
M. Lindner,
O. Litaize,
T. Materna,
A. Minotti,
H. Pessard,
J. -S. Réal,
C. Roca,
T. Salagnac,
V. Savu,
S. Schoppmann
, et al. (5 additional authors not shown)
Abstract:
The STEREO experiment measures the electron antineutrino spectrum emitted in a research reactor using the inverse beta decay reaction on H nuclei in a gadolinium loaded liquid scintillator. The detection is based on a signal coincidence of a prompt positron and a delayed neutron capture event. The simulated response of the neutron capture on gadolinium is crucial for the comparison with data, in p…
▽ More
The STEREO experiment measures the electron antineutrino spectrum emitted in a research reactor using the inverse beta decay reaction on H nuclei in a gadolinium loaded liquid scintillator. The detection is based on a signal coincidence of a prompt positron and a delayed neutron capture event. The simulated response of the neutron capture on gadolinium is crucial for the comparison with data, in particular in the case of the detection efficiency. Among all stable isotopes, $^{155}$Gd and $^{157}$Gd have the highest cross sections for thermal neutron capture. The excited nuclei after the neutron capture emit gamma rays with a total energy of about 8 MeV. The complex level schemes of $^{156}$Gd and $^{158}$Gd are a challenge for the modeling and prediction of the deexcitation spectrum, especially for compact detectors where gamma rays can escape the active volume. With a new description of the Gd(n,$γ$) cascades obtained using the FIFRELIN code, the agreement between simulation and measurements with a neutron calibration source was significantly improved in the STEREO experiment. A database of ten millions of deexcitation cascades for each isotope has been generated and is now available for the user.
△ Less
Submitted 24 October, 2019; v1 submitted 28 May, 2019;
originally announced May 2019.
-
Neutron Scattering Instrumentation at Compact Neutron Sources
Authors:
Sarah Böhm,
Tobias Cronert,
Jan-Philipp Dabrück,
Xavier Fabrèges,
Thomas Gutberlet,
Ferenc Mezei,
Alain Letourneau,
Alain Menelle,
Frédéric Ott,
Ulrich Rücker,
Hoang Tran,
Jorg Voïgt,
Paul Zakalek
Abstract:
There is currently a strong interest in Compact Accelerator-based Neutron Source (CANS) as a possible new type of source for neutron scattering experiments. A workshop around the "Neutron scattering instrumentation around CANS" was organized in July 2017 between several European institutes. This report summarizes the main outcome of the discussions. The document is aiming at providing general guid…
▽ More
There is currently a strong interest in Compact Accelerator-based Neutron Source (CANS) as a possible new type of source for neutron scattering experiments. A workshop around the "Neutron scattering instrumentation around CANS" was organized in July 2017 between several European institutes. This report summarizes the main outcome of the discussions. The document is aiming at providing general guidelines for the instrumentation around CANS. Detailed technical discussions are or will be provided in specific publications.
△ Less
Submitted 7 September, 2018;
originally announced September 2018.
-
The STEREO Experiment
Authors:
N. Allemandou,
H. Almazán,
P. del Amo Sanchez,
L. Bernard,
C. Bernard,
A. Blanchet,
A. Bonhomme,
G. Bosson,
O. Bourrion,
J. Bouvier,
C. Buck,
V. Caillot,
M. Chala,
P. Champion,
P. Charon,
A. Collin,
P. Contrepois,
G. Coulloux,
B. Desbrières,
G. Deleglise,
W. El Kanawati,
J. Favier,
S. Fuard,
I. Gomes Monteiro,
B. Gramlich
, et al. (40 additional authors not shown)
Abstract:
The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research n…
▽ More
The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research nuclear reactor of the Institut Laue Langevin in Grenoble, France. This paper describes the STEREO site, the detector components and associated shielding designed to suppress the external sources of background which were characterized on site. It reports the performances in terms of detector response and energy reconstruction.
△ Less
Submitted 14 August, 2018; v1 submitted 24 April, 2018;
originally announced April 2018.
-
Reactor antineutrino shoulder explained by energy scale nonlinearities?
Authors:
G. Mention,
M. Vivier,
J. Gaffiot,
T. Lasserre,
A. Letourneau,
T. Materna
Abstract:
The Daya Bay, Double Chooz and RENO experiments recently observed a significant distortion in their detected reactor antineutrino spectra, being at odds with the current predictions. Although such a result suggests to revisit the current reactor antineutrino spectra modeling, an alternative scenario, which could potentially explain this anomaly, is explored in this letter. Using an appropriate sta…
▽ More
The Daya Bay, Double Chooz and RENO experiments recently observed a significant distortion in their detected reactor antineutrino spectra, being at odds with the current predictions. Although such a result suggests to revisit the current reactor antineutrino spectra modeling, an alternative scenario, which could potentially explain this anomaly, is explored in this letter. Using an appropriate statistical method, a study of the Daya Bay experiment energy scale is performed. While still being in agreement with the γ calibration data and Boron 12 measured spectrum, it is shown that a O(1%) deviation of the energy scale reproduces the distortion observed in the Daya Bay spectrum, remaining within the quoted calibration uncertainties. Potential origins of such a deviation, which challenge the energy calibration of these detectors, are finally discussed.
△ Less
Submitted 26 May, 2017;
originally announced May 2017.
-
Neutrons production on the IPHI accelerator for the validation of the design of the compact neutron source SONATE
Authors:
Alain Menelle,
Frederic Ott,
Fabien Prunes,
Benoit Homatter,
Burkhard Annighöfer,
Florence Porcher,
Christiane Alba-Simionesco,
Nicolas Chauvin,
Jérôme Schwindling,
Alain Letourneau,
Anthony Marchix,
Ngoc-Hoang Tran
Abstract:
We aim at building an accelerator based compact neutron source which would provide a thermal neutron flux on the order of 4E12 n.s-1.cm-2.sr-1. Such brilliance would put compact neutron sources on par with existing medium flux neutron research reactors. We performed the first neutron production tests on the IPHI proton accelerator at Saclay. The neutron fluxes were measured using gold foil activat…
▽ More
We aim at building an accelerator based compact neutron source which would provide a thermal neutron flux on the order of 4E12 n.s-1.cm-2.sr-1. Such brilliance would put compact neutron sources on par with existing medium flux neutron research reactors. We performed the first neutron production tests on the IPHI proton accelerator at Saclay. The neutron fluxes were measured using gold foil activation and 3He detectors. The measured fluxes were compared with MCNP and GEANT4 Monte Carlo simulations in which the whole experimental setup was modelled. There is a good agreement between the experimental measurements and the Monte-Carlo simulations. The available modelling tools will allow us to optimize the whole Target Moderator Reflector assembly together with the neutron scattering spectrometer geometries.
△ Less
Submitted 26 January, 2017; v1 submitted 1 December, 2016;
originally announced December 2016.
-
Performances of Neutron Scattering Spectrometers on a Compact Neutron Source
Authors:
Xavier Fabrèges,
Alain Menelle,
Frédéric Ott,
Nicolas Chauvin,
Jérôme Schwindling,
Alain Letourneau,
Anthony Marchix,
Christiane Alba-Simionesco
Abstract:
There is currently a big effort put into the operation and construction of world class neutron scattering facilities (SNS and SNS-TS2 in the US, J-PARC in Japan, ESS in Europe, CSS in China, PIK in Russia). On the other hand, there exists a network of smaller neutron scattering facilities which play a key role in creating a large neutron scattering community who is able to efficiently use the exis…
▽ More
There is currently a big effort put into the operation and construction of world class neutron scattering facilities (SNS and SNS-TS2 in the US, J-PARC in Japan, ESS in Europe, CSS in China, PIK in Russia). On the other hand, there exists a network of smaller neutron scattering facilities which play a key role in creating a large neutron scattering community who is able to efficiently use the existing facilities. With the foreseen closure of the ageing nuclear research reactors, especially in Europe there is a risk of seeing a shrinking of the community who would then be able to use efficiently the world class facilities. There is thus a reflection being conducted in several countries for the replacement of smaller research reactors with low energy accelerator based sources. We consider here a reference design for a compact neutron source based on existing accelerator components. We estimate the performances of various types of neutron scattering instruments built around such a source. The results suggest that nowadays state of the art neutron scattering experiments could be successfully performed on such a compact source and that it is thus a viable replacement solution for neutron research reactors.
△ Less
Submitted 26 January, 2017; v1 submitted 1 December, 2016;
originally announced December 2016.
-
Characterization of the Spontaneous Light Emission of the PMTs used in the Double Chooz Experiment
Authors:
Double Chooz collaboration,
Y. Abe,
T. Abrahão,
H. Almazan,
C. Alt,
S. Appel,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Calvo,
L. Camilleri,
R. Carr,
M. Cerrada,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad
, et al. (124 additional authors not shown)
Abstract:
During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical volume has been observed. A specific study of the ensemble of phenomena called "Light Noise" has been carried out in-situ, and in an external laboratory, in order to characterize the signals and to identify the possible…
▽ More
During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical volume has been observed. A specific study of the ensemble of phenomena called "Light Noise" has been carried out in-situ, and in an external laboratory, in order to characterize the signals and to identify the possible processes underlying the effect. Some mechanisms of instrumental noise originating from the PMTs were identified and it has been found that the leading one arises from the light emission localized on the photomultiplier base and produced by the combined effect of heat and high voltage across the transparent epoxy resin covering the electric components. The correlation of the rate and the amplitude of the signal with the temperature has been observed. For the first detector in operation the induced background has been mitigated using online and offline analysis selections based on timing and light pattern of the signals, while a modification of the photomultiplier assembly has been implemented for the second detector in order to blacken the PMT bases.
△ Less
Submitted 17 August, 2016; v1 submitted 23 April, 2016;
originally announced April 2016.
-
Muon capture on light isotopes in Double Chooz
Authors:
Double Chooz collaboration,
Y. Abe,
T. Abrahão,
H. Almazan,
C. Alt,
S. Appel,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
L. Camilleri,
R. Carr,
M. Cerrada,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad
, et al. (122 additional authors not shown)
Abstract:
Using the Double Chooz detector, designed to measure the neutrino mixing angle $θ_{13}$, the products of $μ^-$ capture on $^{12}$C, $^{13}$C, $^{14}$N and $^{16}$O have been measured. Over a period of 489.5 days, $2.3\times10^6$ stop** cosmic $μ^-$ have been collected, of which $1.8\times10^5$ captured on carbon, nitrogen, or oxygen nuclei in the inner detector scintillator or acrylic vessels. T…
▽ More
Using the Double Chooz detector, designed to measure the neutrino mixing angle $θ_{13}$, the products of $μ^-$ capture on $^{12}$C, $^{13}$C, $^{14}$N and $^{16}$O have been measured. Over a period of 489.5 days, $2.3\times10^6$ stop** cosmic $μ^-$ have been collected, of which $1.8\times10^5$ captured on carbon, nitrogen, or oxygen nuclei in the inner detector scintillator or acrylic vessels. The resulting isotopes were tagged using prompt neutron emission (when applicable), the subsequent beta decays, and, in some cases, $β$-delayed neutrons. The most precise measurement of the rate of $^{12}\mathrm C(μ^-,ν)^{12}\mathrm B$ to date is reported: $6.57^{+0.11}_{-0.21}\times10^{3}\,\mathrm s^{-1}$, or $(17.35^{+0.35}_{-0.59})\%$ of nuclear captures. By tagging excited states emitting gammas, the ground state transition rate to $^{12}$B has been determined to be $5.68^{+0.14}_{-0.23}\times10^3\,\mathrm s^{-1}$. The heretofore unobserved reactions $^{12}\mathrm C(μ^-,να)^{8}\mathrm{Li}$, $^{13}\mathrm C(μ^-,ν\mathrm nα)^{8}\mathrm{Li}$, and $^{13}\mathrm C(μ^-,ν\mathrm n)^{12}\mathrm B$ are measured. Further, a population of $β$n decays following stop** muons is identified with $5.5σ$ significance. Statistics limit our ability to identify these decays definitively. Assuming negligible production of $^{8}$He, the reaction $^{13}\mathrm C(μ^-,να)^{9}\mathrm{Li}$ is found to be present at the $2.7σ$ level. Limits are set on a variety of other processes.
△ Less
Submitted 17 May, 2016; v1 submitted 23 December, 2015;
originally announced December 2015.
-
Measurement of $θ_{13}$ in Double Chooz using neutron captures on hydrogen with novel background rejection techniques
Authors:
Y. Abe,
S. Appel,
T. Abrahão,
H. Almazan,
C. Alt,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
L. Camilleri,
R. Carr,
M. Cerrada,
E. Chauveau,
P. Chimenti,
A. P. Collin,
J. M. Conrad,
J. I. Crespo-Anadón
, et al. (120 additional authors not shown)
Abstract:
The Double Chooz collaboration presents a measurement of the neutrino mixing angle $θ_{13}$ using reactor $\overlineν_{e}$ observed via the inverse beta decay reaction in which the neutron is captured on hydrogen. This measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050…
▽ More
The Double Chooz collaboration presents a measurement of the neutrino mixing angle $θ_{13}$ using reactor $\overlineν_{e}$ observed via the inverse beta decay reaction in which the neutron is captured on hydrogen. This measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050m from two reactor cores. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties. Accidental coincidences, the dominant background in this analysis, are suppressed by more than an order of magnitude with respect to our previous publication by a multi-variate analysis. These improvements demonstrate the capability of precise measurement of reactor $\overlineν_{e}$ without gadolinium loading. Spectral distortions from the $\overlineν_{e}$ reactor flux predictions previously reported with the neutron capture on gadolinium events are confirmed in the independent data sample presented here. A value of $\sin^{2}2θ_{13} = 0.095^{+0.038}_{-0.039}$(stat+syst) is obtained from a fit to the observed event rate as a function of the reactor power, a method insensitive to the energy spectrum shape. A simultaneous fit of the hydrogen capture events and of the gadolinium capture events yields a measurement of $\sin^{2}2θ_{13} = 0.088\pm0.033$(stat+syst).
△ Less
Submitted 28 December, 2015; v1 submitted 29 October, 2015;
originally announced October 2015.
-
Online Monitoring of the Osiris Reactor with the Nucifer Neutrino Detector
Authors:
G. Boireau,
L. Bouvet,
A. P. Collin,
G. Coulloux,
M. Cribier,
H. Deschamp,
V. Durand,
M. Fechner,
V. Fischer,
J. Gaffiot,
N. Gerard Castaing,
R. Granelli,
Y. Kato,
T. Lasserre,
L. Latron,
P. Legou,
A. Letourneau,
D. Lhuillier,
G. Mention,
T. Mueller,
T-A. Nghiem,
N. Pedrol,
J. Pelzer,
M. Pequignot,
Y. Piret
, et al. (29 additional authors not shown)
Abstract:
Originally designed as a new nuclear reactor monitoring device, the Nucifer detector has successfully detected its first neutrinos. We provide the second shortest baseline measurement of the reactor neutrino flux. The detection of electron antineutrinos emitted in the decay chains of the fission products, combined with reactor core simulations, provides an new tool to assess both the thermal power…
▽ More
Originally designed as a new nuclear reactor monitoring device, the Nucifer detector has successfully detected its first neutrinos. We provide the second shortest baseline measurement of the reactor neutrino flux. The detection of electron antineutrinos emitted in the decay chains of the fission products, combined with reactor core simulations, provides an new tool to assess both the thermal power and the fissile content of the whole nuclear core and could be used by the Inter- national Agency for Atomic Energy (IAEA) to enhance the Safeguards of civil nuclear reactors. Deployed at only 7.2m away from the compact Osiris research reactor core (70MW) operating at the Saclay research centre of the French Alternative Energies and Atomic Energy Commission (CEA), the experiment also exhibits a well-suited configuration to search for a new short baseline oscillation. We report the first results of the Nucifer experiment, describing the performances of the 0.85m3 detector remotely operating at a shallow depth equivalent to 12m of water and under intense background radiation conditions. Based on 145 (106) days of data with reactor ON (OFF), leading to the detection of an estimated 40760 electron antineutrinos, the mean number of detected antineutrinos is 281 +- 7(stat) +- 18(syst) electron antineutrinos/day, in agreement with the prediction 277(23) electron antineutrinos/day. Due the the large background no conclusive results on the existence of light sterile neutrinos could be derived, however. As a first societal application we quantify how antineutrinos could be used for the Plutonium Management and Disposition Agreement.
△ Less
Submitted 25 May, 2016; v1 submitted 18 September, 2015;
originally announced September 2015.
-
Prompt directional detection of galactic supernova by combining large liquid scintillator neutrino detectors
Authors:
V. Fischer,
T. Chirac,
T. Lasserre,
C. Volpe,
M. Cribier,
M. Durero,
J. Gaffiot,
T. Houdy,
A. Letourneau,
G. Mention,
M. Pequignot,
V. Sibille,
M. Vivier
Abstract:
Core-collapse supernovae produce an intense burst of electron antineutrinos in the few-tens-of-MeV range. Several Large Liquid Scintillator-based Detectors (LLSD) are currently operated worldwide, being very effective for low energy antineutrino detection through the Inverse Beta Decay (IBD) process. In this article, we develop a procedure for the prompt extraction of the supernova location by rev…
▽ More
Core-collapse supernovae produce an intense burst of electron antineutrinos in the few-tens-of-MeV range. Several Large Liquid Scintillator-based Detectors (LLSD) are currently operated worldwide, being very effective for low energy antineutrino detection through the Inverse Beta Decay (IBD) process. In this article, we develop a procedure for the prompt extraction of the supernova location by revisiting the details of IBD kinematics over the broad energy range of supernova neutrinos. Combining all current scintillator-based detector, we show that one can locate a canonical supernova at 10 kpc with an accuracy of 45 degrees (68% C.L.). After the addition of the next generation of scintillator-based detectors, the accuracy could reach 12 degrees (68% C.L.), therefore reaching the performances of the large water Cerenkov neutrino detectors. We also discuss a possible improvement of the SuperNova Early Warning System (SNEWS) inter-experiment network with the implementation of a directionality information in each experiment. Finally, we discuss the possibility to constrain the neutrino energy spectrum as well as the mass of the newly born neutron star with the LLSD data
△ Less
Submitted 25 August, 2015; v1 submitted 21 April, 2015;
originally announced April 2015.
-
Experimental Parameters for a Cerium 144 Based Intense Electron Antineutrino Generator Experiment at Very Short Baselines
Authors:
J. Gaffiot,
T. Lasserre,
G. Mention,
M. Vivier,
M. Cribier,
M. Durero,
V. Fischer,
A. Letourneau,
E. Dumonteil,
I. S. Saldikov,
G. V. Tikhomirov
Abstract:
The standard three-neutrino oscillation paradigm, associated with small squared mass splittings $\ll 0.1\ \mathrm{eV^2}$, has been successfully built up over the last 15 years using solar, atmospheric, long baseline accelerator and reactor neutrino experiments. However, this well-established picture might suffer from anomalous results reported at very short baselines in some of these experiments.…
▽ More
The standard three-neutrino oscillation paradigm, associated with small squared mass splittings $\ll 0.1\ \mathrm{eV^2}$, has been successfully built up over the last 15 years using solar, atmospheric, long baseline accelerator and reactor neutrino experiments. However, this well-established picture might suffer from anomalous results reported at very short baselines in some of these experiments. If not experimental artifacts, such results could possibly be interpreted as the existence of at least an additional fourth sterile neutrino species, mixing with the known active flavors with an associated mass splitting $\ll 0.1\ \mathrm{eV^2}$, and being insensitive to standard weak interactions. Precision measurements at very short baselines (5 to 15 m) with intense MeV electronic antineutrino emitters can be used to probe these anomalies. In this article, the expected antineutrino signal and backgrounds of a generic experiment which consists of deploying an intense beta minus radioactive source inside or in the vicinity of a large liquid scintillator detector are studied. The technical challenges to perform such an experiment are identified, along with quantifying the possible source and detector induced systematics, and their impact on the sensitivity to the observation of neutrino oscillations at short baselines.
△ Less
Submitted 9 February, 2015; v1 submitted 24 November, 2014;
originally announced November 2014.
-
Ortho-positronium observation in the Double Chooz Experiment
Authors:
Y. Abe,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadon,
K. Crum,
A. S. Cucoanes
, et al. (121 additional authors not shown)
Abstract:
The Double Chooz experiment measures the neutrino mixing angle $θ_{13}$ by detecting reactor $\barν_e$ via inverse beta decay. The positron-neutron space and time coincidence allows for a sizable background rejection, nonetheless liquid scintillator detectors would profit from a positron/electron discrimination, if feasible in large detector, to suppress the remaining background. Standard particle…
▽ More
The Double Chooz experiment measures the neutrino mixing angle $θ_{13}$ by detecting reactor $\barν_e$ via inverse beta decay. The positron-neutron space and time coincidence allows for a sizable background rejection, nonetheless liquid scintillator detectors would profit from a positron/electron discrimination, if feasible in large detector, to suppress the remaining background. Standard particle identification, based on particle dependent time profile of photon emission in liquid scintillator, can not be used given the identical mass of the two particles. However, the positron annihilation is sometimes delayed by the ortho-positronium (o-Ps) metastable state formation, which induces a pulse shape distortion that could be used for positron identification. In this paper we report on the first observation of positronium formation in a large liquid scintillator detector based on pulse shape analysis of single events. The o-Ps formation fraction and its lifetime were measured, finding the values of 44$\%$ $\pm$ 12$\%$ (sys.) $\pm$ 5$\%$ (stat.) and $3.68$ns $\pm$ 0.17ns (sys.) $\pm$ 0.15ns (stat.) respectively, in agreement with the results obtained with a dedicated positron annihilation lifetime spectroscopy setup.
△ Less
Submitted 7 October, 2014; v1 submitted 25 July, 2014;
originally announced July 2014.
-
Improved measurements of the neutrino mixing angle $θ_{13}$ with the Double Chooz detector
Authors:
Y. Abe,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadón,
K. Crum,
A. S. Cucoanes
, et al. (121 additional authors not shown)
Abstract:
The Double Chooz experiment presents improved measurements of the neutrino mixing angle $θ_{13}$ using the data collected in 467.90 live days from a detector positioned at an average distance of 1050 m from two reactor cores at the Chooz nuclear power plant. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties with respect t…
▽ More
The Double Chooz experiment presents improved measurements of the neutrino mixing angle $θ_{13}$ using the data collected in 467.90 live days from a detector positioned at an average distance of 1050 m from two reactor cores at the Chooz nuclear power plant. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties with respect to previous publications, whereas the efficiency of the $\barν_{e}$ signal has increased. The value of $θ_{13}$ is measured to be $\sin^{2}2θ_{13} = 0.090 ^{+0.032}_{-0.029}$ from a fit to the observed energy spectrum. Deviations from the reactor $\barν_{e}$ prediction observed above a prompt signal energy of 4 MeV and possible explanations are also reported. A consistent value of $θ_{13}$ is obtained from a fit to the observed rate as a function of the reactor power independently of the spectrum shape and background estimation, demonstrating the robustness of the $θ_{13}$ measurement despite the observed distortion.
△ Less
Submitted 21 January, 2015; v1 submitted 30 June, 2014;
originally announced June 2014.
-
Precision Muon Reconstruction in Double Chooz
Authors:
Double Chooz collaboration,
Y. Abe,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadón,
K. Crum
, et al. (119 additional authors not shown)
Abstract:
We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volu…
▽ More
We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volumes. All muons are fit under the hypothesis that they are through-going and ultrarelativistic. If the energy depositions suggest that the muon may have stopped, the reconstruction fits also for this hypothesis and chooses between the two via the relative goodness-of-fit. In the ideal case of a through-going muon intersecting the center of the detector, the resolution is ~40 mm in each transverse dimension. High quality muon reconstruction is an important tool for reducing the impact of the cosmogenic isotope background in Double Chooz.
△ Less
Submitted 15 August, 2014; v1 submitted 23 May, 2014;
originally announced May 2014.
-
CeLAND: search for a 4th light neutrino state with a 3 PBq 144Ce-144Pr electron antineutrino generator in KamLAND
Authors:
A. Gando,
Y. Gando,
S. Hayashida,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
H. Ishikawa,
M. Koga,
R. Matsuda,
S. Matsuda,
T. Mitsui,
D. Motoki,
K. Nakamura,
Y. Oki,
M. Otani,
I. Shimizu,
J. Shirai,
F. Suekane,
A. Suzuki,
Y. Takemoto,
K. Tamae,
K. Ueshima,
H. Watanabe,
B. D. Xu,
S. Yamada
, et al. (41 additional authors not shown)
Abstract:
The reactor neutrino and gallium anomalies can be tested with a 3-4 PBq (75-100 kCi scale) 144Ce-144Pr antineutrino beta-source deployed at the center or next to a large low-background liquid scintillator detector. The antineutrino generator will be produced by the Russian reprocessing plant PA Mayak as early as 2014, transported to Japan, and deployed in the Kamioka Liquid Scintillator Anti-Neutr…
▽ More
The reactor neutrino and gallium anomalies can be tested with a 3-4 PBq (75-100 kCi scale) 144Ce-144Pr antineutrino beta-source deployed at the center or next to a large low-background liquid scintillator detector. The antineutrino generator will be produced by the Russian reprocessing plant PA Mayak as early as 2014, transported to Japan, and deployed in the Kamioka Liquid Scintillator Anti-Neutrino Detector (KamLAND) as early as 2015. KamLAND's 13 m diameter target volume provides a suitable environment to measure the energy and position dependence of the detected neutrino flux. A characteristic oscillation pattern would be visible for a baseline of about 10 m or less, providing a very clean signal of neutrino disappearance into a yet-unknown, sterile neutrino state. This will provide a comprehensive test of the electron dissaperance neutrino anomalies and could lead to the discovery of a 4th neutrino state for Delta_m^2 > 0.1 eV^2 and sin^2(2theta) > 0.05.
△ Less
Submitted 13 April, 2014; v1 submitted 3 December, 2013;
originally announced December 2013.
-
Reactor electron antineutrino disappearance in the Double Chooz experiment
Authors:
Y. Abe,
C. Aberle,
J. C. dos Anjos,
J. C. Barriere,
M. Bergevin,
A. Bernstein,
T. J. C. Bezerra,
L. Bezrukhov,
E. Blucher,
N. S. Bowden,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
P. Chimenti,
T. Classen,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadón,
K. Crum
, et al. (140 additional authors not shown)
Abstract:
The Double Chooz experiment has observed 8,249 candidate electron antineutrino events in 227.93 live days with 33.71 GW-ton-years (reactor power x detector mass x livetime) exposure using a 10.3 cubic meter fiducial volume detector located at 1050 m from the reactor cores of the Chooz nuclear power plant in France. The expectation in case of theta13 = 0 is 8,937 events. The deficit is interpreted…
▽ More
The Double Chooz experiment has observed 8,249 candidate electron antineutrino events in 227.93 live days with 33.71 GW-ton-years (reactor power x detector mass x livetime) exposure using a 10.3 cubic meter fiducial volume detector located at 1050 m from the reactor cores of the Chooz nuclear power plant in France. The expectation in case of theta13 = 0 is 8,937 events. The deficit is interpreted as evidence of electron antineutrino disappearance. From a rate plus spectral shape analysis we find sin^2 2θ13 = 0.109 \pm 0.030(stat) \pm 0.025(syst). The data exclude the no-oscillation hypothesis at 99.8% CL (2.9σ).
△ Less
Submitted 30 August, 2012; v1 submitted 26 July, 2012;
originally announced July 2012.
-
A large HPGe detector for the non-destructive radioassay of an ultra-low-background counting facility
Authors:
M. Fechner,
C. Henson,
J. Gaffiot,
T. Lasserre,
A. Letourneau,
D. Lhuillier,
G. Mention,
Th. A. Mueller,
R. Quéval,
R. Svoboda
Abstract:
We present the use of a low background counting facility, equipped with a p-type 80% relative efficiency HPGe detector, protected by active and passive shielding, and large enough to count a 10" photo-multiplier tube (PMT). A GEANT4 Monte-Carlo of this detector was developed and tuned to 3% accuracy. We report the U, Th, and K contents in three different types of PMTs used in current neutrino expe…
▽ More
We present the use of a low background counting facility, equipped with a p-type 80% relative efficiency HPGe detector, protected by active and passive shielding, and large enough to count a 10" photo-multiplier tube (PMT). A GEANT4 Monte-Carlo of this detector was developed and tuned to 3% accuracy. We report the U, Th, and K contents in three different types of PMTs used in current neutrino experiments, with accuracies of $\sim 10$ ppb for U and Th and of $\sim 15$ ppm for K.
△ Less
Submitted 20 January, 2011;
originally announced January 2011.
-
SNIF: A Futuristic Neutrino Probe for Undeclared Nuclear Fission Reactors
Authors:
Thierry Lasserre,
Maximilien Fechner,
Guillaume Mention,
Romain Reboulleau,
Michel Cribier,
Alain Letourneau,
David Lhuillier
Abstract:
Today reactor neutrino experiments are at the cutting edge of fundamental research in particle physics. Understanding the neutrino is far from complete, but thanks to the impressive progress in this field over the last 15 years, a few research groups are seriously considering that neutrinos could be useful for society. The International Atomic Energy Agency (IAEA) works with its Member States to p…
▽ More
Today reactor neutrino experiments are at the cutting edge of fundamental research in particle physics. Understanding the neutrino is far from complete, but thanks to the impressive progress in this field over the last 15 years, a few research groups are seriously considering that neutrinos could be useful for society. The International Atomic Energy Agency (IAEA) works with its Member States to promote safe, secure and peaceful nuclear technologies. In a context of international tension and nuclear renaissance, neutrino detectors could help IAEA to enforce the Treaty on the Non-Proliferation of Nuclear Weapons (NPT). In this article we discuss a futuristic neutrino application to detect and localize an undeclared nuclear reactor from across borders. The SNIF (Secret Neutrino Interactions Finder) concept proposes to use a few hundred thousand tons neutrino detectors to unveil clandestine fission reactors. Beyond previous studies we provide estimates of all known background sources as a function of the detector's longitude, latitude and depth, and we discuss how they impact the detectability.
△ Less
Submitted 16 November, 2010;
originally announced November 2010.