-
A novel cryogenic VUV spectrofluorometer for the characterization of wavelength shifters
Authors:
A. Leonhardt,
M. Goldbrunner,
B. Hackett,
S. Schönert
Abstract:
We present a novel cryogenic VUV spectrofluorometer designed for the characterization of wavelength shifters (WLS) crucial for experiments based on liquid argon (LAr) scintillation light detection. Wavelength shifters like 1,1,4,4-tetraphenyl-1,3-butadiene (TPB) or polyethylene naphthalate (PEN) are used in these experiments to shift the VUV scintillation light to the visible region. Precise knowl…
▽ More
We present a novel cryogenic VUV spectrofluorometer designed for the characterization of wavelength shifters (WLS) crucial for experiments based on liquid argon (LAr) scintillation light detection. Wavelength shifters like 1,1,4,4-tetraphenyl-1,3-butadiene (TPB) or polyethylene naphthalate (PEN) are used in these experiments to shift the VUV scintillation light to the visible region. Precise knowledge of the optical properties of the WLS at liquid argon's temperature (87 K) and LAr scintillation wavelength (128 nm) is necessary to model and understand the detector response. The cryogenic VUV spectrofluorometer was commissioned to measure the emission spectra and relative wavelength shifting efficiency (WLSE) of samples between 300 K and 87 K for VUV (128 nm to 190 nm) and UV (310 nm) excitation. New mitigation techniques for surface effects on cold WLS were established. As part of this work, the TPB-based wavelength shifting reflector (WLSR) featured in the neutrinoless double-beta decay experiment LEGEND-200 was characterized. The wavelength shifting efficiency was observed to increase by (54 +/- 5)% from room temperature (RT) to 87 K. PEN installed in LEGEND-200 was also characterized and a first measurement of the relative wavelength shifting efficiency and emission spectrum at RT and 87 K is presented. The WLSE of amorphous PEN was found to be enhanced by at least (37 +/- 4)% for excitation with 128 nm and by (52 +/- 3)% for UV excitation at 87 K compared to RT.
△ Less
Submitted 2 April, 2024; v1 submitted 27 November, 2023;
originally announced November 2023.
-
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen
, et al. (125 additional authors not shown)
Abstract:
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi…
▽ More
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.
△ Less
Submitted 10 October, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Optical properties of low background PEN structural components for the LEGEND-200 experiment
Authors:
L. Manzanillas,
Y. Efremenko,
M. Febbraro,
F. Fischer,
M. Guitart Corominas,
B. Hackett,
A. Leonhardt,
B. Majorovits,
O. Schulz
Abstract:
Polyethylene Naphthalate (PEN) plastic scintillator has been identified as potential self-vetoing structural material in low-background physics experiments. Scintillating components have been produced radio-pure from PEN using injection compression molding technology. These low-background PEN components will be used as active holders to mount the Germanium detectors in the \legend-$200$ neutrinole…
▽ More
Polyethylene Naphthalate (PEN) plastic scintillator has been identified as potential self-vetoing structural material in low-background physics experiments. Scintillating components have been produced radio-pure from PEN using injection compression molding technology. These low-background PEN components will be used as active holders to mount the Germanium detectors in the \legend-$200$ neutrinoless double beta decay experiment. In this paper we present the measurement of the optical properties of these PEN components. Thus, the emission spectrum, time constant, attenuation and bulk absorption length as well as light output and light yield are reported. In addition, the surface of these PEN components has been characterized and an estimation of the surface roughness is presented. Moreover, the light output of the final \legend-$200$ detector holders has been measured and is reported. These measurements were used to estimate the self-vetoing efficiency of these holders.
△ Less
Submitted 30 August, 2022; v1 submitted 28 April, 2022;
originally announced April 2022.
-
Development and characterization of a slow wavelength shifting coating for background rejection in liquid argon detectors
Authors:
D. Gallacher,
A. Leonhardt,
H. Benmansour,
E. Ellingwood,
Q. Hars,
M. Kuźniak,
J. Anstey,
B. Bondzior,
M. G. Boulay,
B. Cai,
P. J. Dereń,
P. C. F. Di Stefano,
S. Garg,
J. Mason,
T. R. Pollmann,
P. Skensved,
V. Strickland,
M. Stringer
Abstract:
We describe a technique, applicable to liquid-argon-based dark matter detectors, allowing for discrimination of alpha-decays in detector regions with incomplete light collection from nuclear-recoil-like events.
Nuclear recoils and alpha events preferentially excite the liquid argon (LAr) singlet state, which has a decay time of ~6 ns. The wavelength-shifter TPB, which is typically applied to the…
▽ More
We describe a technique, applicable to liquid-argon-based dark matter detectors, allowing for discrimination of alpha-decays in detector regions with incomplete light collection from nuclear-recoil-like events.
Nuclear recoils and alpha events preferentially excite the liquid argon (LAr) singlet state, which has a decay time of ~6 ns. The wavelength-shifter TPB, which is typically applied to the inside of the active detector volume to make the LAr scintillation photons visible, has a short re-emission time that preserves the LAr scintillation timing. We developed a wavelength-shifting polymeric film - pyrene-doped polystyrene - for the DEAP-3600 detector and describe the production method and characterization. At liquid argon temperature, the film's re-emission timing is dominated by a modified exponential decay with time constant of 279(14) ns and has a wavelength-shifting efficiency of 46.4(2.9) % relative to TPB, measured at room temperature. By coating the detector neck (a region outside the active volume where the scintillation light collection efficiency is low) with this film, the visible energy and the scintillation pulse shape of alpha events in the neck region are modified, and we predict that through pulse shape discrimination, the coating will afford a suppression factor of O($10^{5}$) against these events.
△ Less
Submitted 24 December, 2021; v1 submitted 14 September, 2021;
originally announced September 2021.
-
LEGEND-1000 Preconceptual Design Report
Authors:
LEGEND Collaboration,
N. Abgrall,
I. Abt,
M. Agostini,
A. Alexander,
C. Andreoiu,
G. R. Araujo,
F. T. Avignone III,
W. Bae,
A. Bakalyarov,
M. Balata,
M. Bantel,
I. Barabanov,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
L. Baudis,
C. Bauer,
E. Bernieri,
L. Bezrukov,
K. H. Bhimani,
V. Biancacci,
E. Blalock,
A. Bolozdynya
, et al. (239 additional authors not shown)
Abstract:
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory…
▽ More
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory. By combining the lowest background levels with the best energy resolution in the field, LEGEND-1000 will perform a quasi-background-free search and can make an unambiguous discovery of neutrinoless double-beta decay with just a handful of counts at the decay $Q$ value. The experiment is designed to probe this decay with a 99.7%-CL discovery sensitivity in the $^{76}$Ge half-life of $1.3\times10^{28}$ years, corresponding to an effective Majorana mass upper limit in the range of 9-21 meV, to cover the inverted-ordering neutrino mass scale with 10 yr of live time.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Direct comparison of PEN and TPB wavelength shifters in a liquid argon detector
Authors:
M. G. Boulay,
V. Camillo,
N. Canci,
S. Choudhary,
L. Consiglio,
A. Flammini,
C. Galbiati,
C. Ghiano,
A. Gola,
S. Horikawa,
P. Kachru,
I. Kochanek,
K. Kondo,
G. Korga,
M. Kuźniak,
M. Kuźwa,
A. Leonhardt,
T. Łęcki,
A. Mazzi,
A. Moharana,
G. Nieradka,
G. Paternoster,
T. R. Pollmann,
A. Razeto,
D. Sablone
, et al. (4 additional authors not shown)
Abstract:
A large number of particle detectors employ liquid argon as their target material owing to its high scintillation yield and its ability to drift ionization charge over large distances. Scintillation light from argon is peaked at 128 nm and a wavelength shifter is required for its efficient detection. In this work, we directly compare the light yield achieved in two identical liquid argon chambers,…
▽ More
A large number of particle detectors employ liquid argon as their target material owing to its high scintillation yield and its ability to drift ionization charge over large distances. Scintillation light from argon is peaked at 128 nm and a wavelength shifter is required for its efficient detection. In this work, we directly compare the light yield achieved in two identical liquid argon chambers, one of which is equipped with PolyEthylene Naphthalate (PEN) and the other with TetraPhenyl Butadiene (TPB) wavelength shifter. Both chambers are lined with enhanced specular reflectors and instrumented with SiPMs with a coverage fraction of approximately 1%, which represents a geometry comparable to the future large scale detectors. We measured the light yield of the PEN chamber to be 39.4$\pm$0.4(stat)$\pm$1.9(syst)% of the yield of the TPB chamber. Using a Monte Carlo simulation this result is used to extract the wavelength shifting efficiency of PEN relative to TPB equal to 47.2$\pm$5.7%. This result paves the way for the use of easily available PEN foils as a wavelength shifter, which can substantially simplify the construction of future liquid argon detectors.
△ Less
Submitted 15 March, 2022; v1 submitted 29 June, 2021;
originally announced June 2021.
-
Development of very-thick transparent GEMs with wavelength-shifting capability for noble element TPCs
Authors:
M. Kuźniak,
D. González-Díaz,
P. Amedo,
C. D. R. Azevedo,
D. J. Fernández-Posada,
M. Kuźwa,
S. Leardini,
A. Leonhardt,
T. Łęcki,
L. Manzanillas,
D. Muenstermann,
G. Nieradka,
R. de Oliveira,
T. R. Pollmann,
A. Saá Hernández,
T. Sworobowicz,
C. Türkoğlu,
S. Williams
Abstract:
A new concept for the simultaneous detection of primary and secondary scintillation in time projection chambers is proposed. Its core element is a type of very-thick GEM structure supplied with transparent electrodes and machined from a polyethylene naphthalate plate, a natural wavelength-shifter. Such a device has good prospects for scalability and, by virtue of its genuine optical properties, it…
▽ More
A new concept for the simultaneous detection of primary and secondary scintillation in time projection chambers is proposed. Its core element is a type of very-thick GEM structure supplied with transparent electrodes and machined from a polyethylene naphthalate plate, a natural wavelength-shifter. Such a device has good prospects for scalability and, by virtue of its genuine optical properties, it can improve on the light collection efficiency, energy threshold and resolution of conventional micropattern gas detectors. This, together with the intrinsic radiopurity of its constituting elements, offers advantages for noble gas and liquid based time projection chambers, used for dark matter searches and neutrino experiments. Production, optical and electrical characterization, and first measurements performed with the new device are reported.
△ Less
Submitted 15 March, 2022; v1 submitted 7 June, 2021;
originally announced June 2021.
-
Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
Authors:
The DEAP Collaboration,
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
D. J. Auty,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
J. M. Corning
, et al. (104 additional authors not shown)
Abstract:
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window ar…
▽ More
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the charge of a single photoelectron, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulseshape and for afterpulsing in the light detectors.
The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.
△ Less
Submitted 6 April, 2021; v1 submitted 22 March, 2021;
originally announced March 2021.
-
Investigation of the surface properties of different highly aligned N-MWCNT carpets
Authors:
V. Eckert,
E. Haubold,
S. Oswald,
S. Michel,
C. Bellmann,
P. Potapov,
D. Wolf,
S. Hampel,
B. Büchner,
M. Mertig,
A. Leonhardt
Abstract:
We investigated the physicochemical surface properties of different highly aligned nitrogen-doped multi-walled carbon nanotube (N-MWCNT) carpets, synthesized using toluene/pyrazine, toluene/benzylamine and acetonitrile via a sublimation-based chemical vapor deposition (SCVD) method at 760°C. The surfaces of the N-MWCNT carpets synthesized using toluene/pyrazine and toluene/benzylamine were very hy…
▽ More
We investigated the physicochemical surface properties of different highly aligned nitrogen-doped multi-walled carbon nanotube (N-MWCNT) carpets, synthesized using toluene/pyrazine, toluene/benzylamine and acetonitrile via a sublimation-based chemical vapor deposition (SCVD) method at 760°C. The surfaces of the N-MWCNT carpets synthesized using toluene/pyrazine and toluene/benzylamine were very hydrophobic. In contrast, we observed a complete wetting of the N-MWCNT carpets synthesized using acetonitrile. The difference in the wetting behavior of these N-MWCNT carpets is the main focus in this study and was not investigated before. Here, we show that not only the presence or concentration of nitrogen inside the carbon lattice, but especially it's kind of incorporation have an important influence on the surface polarity.
△ Less
Submitted 17 October, 2019;
originally announced October 2019.
-
Dynamic Assignment in Microsimulations of Pedestrians
Authors:
Tobias Kretz,
Karsten Lehmann,
Ingmar Hofsäß,
Axel Leonhardt
Abstract:
A generic method for dynamic assignment used with microsimulation of pedestrian dynamics is introduced. As pedestrians - unlike vehicles - do not move on a network, but on areas they in principle can choose among an infinite number of routes. To apply assignment algorithms one has to select for each OD pair a finite (realistically a small) number of relevant representatives from these routes. This…
▽ More
A generic method for dynamic assignment used with microsimulation of pedestrian dynamics is introduced. As pedestrians - unlike vehicles - do not move on a network, but on areas they in principle can choose among an infinite number of routes. To apply assignment algorithms one has to select for each OD pair a finite (realistically a small) number of relevant representatives from these routes. This geometric task is the main focus of this contribution. The main task is to find for an OD pair the relevant routes to be used with common assignment methods. The method is demonstrated for one single OD pair and exemplified with an example.
△ Less
Submitted 7 January, 2014;
originally announced January 2014.
-
Investigation of electric conditions in the vicinity of carbon nanotubes grown in a DC plasma sheath
Authors:
J. Blazek,
P. Spatenka,
Ch. Taeschner,
A. Leonhardt
Abstract:
Carbon nanotubes (CNTs - long tubular carbon nanostructures) belong to the best electron field emitting materials. Based on the experimentally determined electron density in the dual hot filament/DC plasma deposition system the electric field close to the substrate and ion energy flux were calculated. The dependences of electric characteristics close to the nanotube tips on various geometric and…
▽ More
Carbon nanotubes (CNTs - long tubular carbon nanostructures) belong to the best electron field emitting materials. Based on the experimentally determined electron density in the dual hot filament/DC plasma deposition system the electric field close to the substrate and ion energy flux were calculated. The dependences of electric characteristics close to the nanotube tips on various geometric and plasma parameters were numerically investigated. Taking into account the field enhancement in the vicinity of the CNTs tips the force acting on them was determined. The reliability of numeric computations was tested on a model of conductive sphere placed in a homogeneous electric field, for which theoretical predictions concerning electric forces and field emission currents can be derived.
△ Less
Submitted 3 November, 2004;
originally announced November 2004.