-
Design of the ECCE Detector for the Electron Ion Collider
Authors:
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin,
R. Capobianco
, et al. (259 additional authors not shown)
Abstract:
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent track…
▽ More
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. This detector concept has been selected to be the basis for the EIC project detector.
△ Less
Submitted 11 May, 2023; v1 submitted 6 September, 2022;
originally announced September 2022.
-
Detector Requirements and Simulation Results for the EIC Exclusive, Diffractive and Tagging Physics Program using the ECCE Detector Concept
Authors:
A. Bylinkin,
C. T. Dean,
S. Fegan,
D. Gangadharan,
K. Gates,
S. J. D. Kay,
I. Korover,
W. B. Li,
X. Li,
R. Montgomery,
D. Nguyen,
G. Penman,
J. R. Pybus,
N. Santiesteban,
R. Trotta,
A. Usman,
M. D. Baker,
J. Frantz,
D. I. Glazier,
D. W. Higinbotham,
T. Horn,
J. Huang,
G. Huber,
R. Reed,
J. Roche
, et al. (258 additional authors not shown)
Abstract:
This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC's exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark-gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detecter system close to the beamline to ensure exclusivity and tag ion beam/fr…
▽ More
This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC's exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark-gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detecter system close to the beamline to ensure exclusivity and tag ion beam/fragments for a particular reaction of interest. Preliminary studies confirmed the proposed technology and design satisfy the requirements. The projected physics impact results are based on the projected detector performance from the simulation at 10 or 100 fb^-1 of integrated luminosity. Additionally, a few insights on the potential 2nd Interaction Region can (IR) were also documented which could serve as a guidepost for the future development of a second EIC detector.
△ Less
Submitted 6 March, 2023; v1 submitted 30 August, 2022;
originally announced August 2022.
-
Open Heavy Flavor Studies for the ECCE Detector at the Electron Ion Collider
Authors:
X. Li,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin
, et al. (262 additional authors not shown)
Abstract:
The ECCE detector has been recommended as the selected reference detector for the future Electron-Ion Collider (EIC). A series of simulation studies have been carried out to validate the physics feasibility of the ECCE detector. In this paper, detailed studies of heavy flavor hadron and jet reconstruction and physics projections with the ECCE detector performance and different magnet options will…
▽ More
The ECCE detector has been recommended as the selected reference detector for the future Electron-Ion Collider (EIC). A series of simulation studies have been carried out to validate the physics feasibility of the ECCE detector. In this paper, detailed studies of heavy flavor hadron and jet reconstruction and physics projections with the ECCE detector performance and different magnet options will be presented. The ECCE detector has enabled precise EIC heavy flavor hadron and jet measurements with a broad kinematic coverage. These proposed heavy flavor measurements will help systematically study the hadronization process in vacuum and nuclear medium especially in the underexplored kinematic region.
△ Less
Submitted 23 July, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Exclusive J/$ψ$ Detection and Physics with ECCE
Authors:
X. Li,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin
, et al. (262 additional authors not shown)
Abstract:
Exclusive heavy quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. The momentum transfer dependence of this process is sensitive to the interaction sites, which provides a powerful tool to probe the…
▽ More
Exclusive heavy quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. The momentum transfer dependence of this process is sensitive to the interaction sites, which provides a powerful tool to probe the spatial distribution of gluons in the nucleus. Recently the problem of the origin of hadron mass has received lots of attention in determining the anomaly contribution $M_{a}$. The trace anomaly is sensitive to the gluon condensate, and exclusive production of quarkonia such as J/$ψ$ and $Υ$ can serve as a sensitive probe to constrain it. In this paper, we present the performance of the ECCE detector for exclusive J/$ψ$ detection and the capability of this process to investigate the above physics opportunities with ECCE.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
Design and Simulated Performance of Calorimetry Systems for the ECCE Detector at the Electron Ion Collider
Authors:
F. Bock,
N. Schmidt,
P. K. Wang,
N. Santiesteban,
T. Horn,
J. Huang,
J. Lajoie,
C. Munoz Camacho,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
W. Boeglin,
M. Borysova,
E. Brash
, et al. (263 additional authors not shown)
Abstract:
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and two hadronic calorimeters. Key…
▽ More
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and two hadronic calorimeters. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.
△ Less
Submitted 19 July, 2022;
originally announced July 2022.
-
AI-assisted Optimization of the ECCE Tracking System at the Electron Ion Collider
Authors:
C. Fanelli,
Z. Papandreou,
K. Suresh,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann
, et al. (258 additional authors not shown)
Abstract:
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the "glue" that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to…
▽ More
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the "glue" that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to leverage Artificial Intelligence (AI) already starting from the design and R&D phases. The EIC Comprehensive Chromodynamics Experiment (ECCE) is a consortium that proposed a detector design based on a 1.5T solenoid. The EIC detector proposal review concluded that the ECCE design will serve as the reference design for an EIC detector. Herein we describe a comprehensive optimization of the ECCE tracker using AI. The work required a complex parametrization of the simulated detector system. Our approach dealt with an optimization problem in a multidimensional design space driven by multiple objectives that encode the detector performance, while satisfying several mechanical constraints. We describe our strategy and show results obtained for the ECCE tracking system. The AI-assisted design is agnostic to the simulation framework and can be extended to other sub-detectors or to a system of sub-detectors to further optimize the performance of the EIC detector.
△ Less
Submitted 19 May, 2022; v1 submitted 18 May, 2022;
originally announced May 2022.
-
Scientific Computing Plan for the ECCE Detector at the Electron Ion Collider
Authors:
J. C. Bernauer,
C. T. Dean,
C. Fanelli,
J. Huang,
K. Kauder,
D. Lawrence,
J. D. Osborn,
C. Paus,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash
, et al. (256 additional authors not shown)
Abstract:
The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing thes…
▽ More
The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing these challenges in the process of producing a complete detector proposal based upon detailed detector and physics simulations. In this document, the software and computing efforts to produce this proposal are discussed; furthermore, the computing and software model and resources required for the future of ECCE are described.
△ Less
Submitted 17 May, 2022;
originally announced May 2022.
-
Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
T. Beyrouthy,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (157 additional authors not shown)
Abstract:
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton co…
▽ More
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Precision timing for collider-experiment-based calorimetry
Authors:
S. V. Chekanov,
F. Simon,
V. Boudry,
W. Chung,
P. W. Gorham,
M. Nguyen,
C. G. Tully,
S. C. Eno,
Y. Lai,
A. V. Kotwal,
S. Ko,
I. Laktineh,
S. Lee,
J. S. H. Lee,
M. T. Lucchini,
R. Prechelt,
H. Yoo,
C. -H Yeh,
S. -S. Yu,
G. S. Varner,
R. Zhu
Abstract:
In this White Paper for the 2021 Snowmass process, we discuss aspects of precision timing within electromagnetic and hadronic calorimeter systems for high-energy physics collider experiments. Areas of applications include particle identification, event and object reconstruction, and pileup mitigation. Two different system options are considered, namely cell-level timing capabilities covering the f…
▽ More
In this White Paper for the 2021 Snowmass process, we discuss aspects of precision timing within electromagnetic and hadronic calorimeter systems for high-energy physics collider experiments. Areas of applications include particle identification, event and object reconstruction, and pileup mitigation. Two different system options are considered, namely cell-level timing capabilities covering the full detector volume, and dedicated timing layers integrated in calorimeter systems. A selection of technologies for the different approaches is also discussed.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
Dual-Readout Calorimetry for Future Experiments Probing Fundamental Physics
Authors:
I. Pezzotti,
Harvey Newman,
J. Freeman,
J. Hirschauer,
R. Ferrari,
G. Gaudio,
G. Polesello,
R. Santoro,
M. Lucchini,
S. Giagu,
F. Bedeschi,
Sehwook Lee,
P. Harris,
C. Tully,
A. Jung,
Nural Akchurin,
A. Belloni,
S. Eno,
J. Qian,
B. Zhou,
J. Zhu,
Jason Sang Hun Lee,
I. Vivarelli,
R. Hirosky,
Hwidong Yoo
Abstract:
In this White Paper for the 2021 Snowmass process, we detail the status and prospects for dual-readout calorimetry. While all calorimeters allow estimation of energy depositions in their active material, dual-readout calorimeters aim to provide additional information on the light produced in the sensitive media via, for example, wavelength and polarization, and/or a precision timing measurements,…
▽ More
In this White Paper for the 2021 Snowmass process, we detail the status and prospects for dual-readout calorimetry. While all calorimeters allow estimation of energy depositions in their active material, dual-readout calorimeters aim to provide additional information on the light produced in the sensitive media via, for example, wavelength and polarization, and/or a precision timing measurements, allowing an estimation of the shower-by-shower particle content. Utilizing this knowledge of the shower particle content may allow unprecedented energy resolution for hadronic particles and jets and new types of particle flow algorithms. We also discuss the impact continued development of this kind of calorimetry could have on precision on Higgs boson property measurements at future colliders.
△ Less
Submitted 4 May, 2022; v1 submitted 8 March, 2022;
originally announced March 2022.
-
Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstr…
▽ More
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high $p_T$ muons in proton--proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.
△ Less
Submitted 22 September, 2021; v1 submitted 20 July, 2021;
originally announced July 2021.
-
Modeling the triple-GEM detector response to background particles for the CMS Experiment
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
I. Azhgirey,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (164 additional authors not shown)
Abstract:
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The…
▽ More
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.
△ Less
Submitted 8 July, 2021;
originally announced July 2021.
-
Neutron Detection using a Gadolinium-Cathode GEM Detector
Authors:
DongHyun Song,
Kyungeon Choi,
Youngun Jeng,
Yechan Kang,
Jason Sang Hun Lee,
Inkyu Park,
Sunyoung Yoo
Abstract:
A gas electron multiplier (GEM) detector with a gadolinium cathode has been developed to explore its potential application as a neutron detector. It consists of three standard-sized ($10\times 10$ cm${}^{2}$) GEM foils and a thin gadolinium plate as the cathode, which is used as a neutron converter. The neutron detection efficiencies were measured for two different cathode setups and for two diffe…
▽ More
A gas electron multiplier (GEM) detector with a gadolinium cathode has been developed to explore its potential application as a neutron detector. It consists of three standard-sized ($10\times 10$ cm${}^{2}$) GEM foils and a thin gadolinium plate as the cathode, which is used as a neutron converter. The neutron detection efficiencies were measured for two different cathode setups and for two different drift gaps. The thermal neutron source at the Korea Research Institute of Standards and Science (KRISS) was used to measure the neutron detection efficiency. Based on the neutron flux measured by KRISS, the neutron detection efficiency of our gadolinium GEM detector was $4.630 \pm 0.034(stat.) \pm 0.279(syst.) \%$.
△ Less
Submitted 4 December, 2020;
originally announced December 2020.
-
Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequent…
▽ More
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.
△ Less
Submitted 20 September, 2020;
originally announced September 2020.