-
A 25-micron single photon sensitive kinetic inductance detector
Authors:
Peter K. Day,
Nicholas F. Cothard,
Christopher Albert,
Logan Foote,
Elijah Kane,
Byeong H. Eom,
Ritoban Basu Thakur,
Reinier M. J. Janssen,
Andrew Beyer,
Pierre Echternach,
Sven van Berkel,
Steven Hailey-Dunsheath,
Thomas R. Stevenson,
Shahab Dabironezare,
Jochem J. A. Baselmans,
Jason Glenn,
C. Matt Bradford,
Henry G. Leduc
Abstract:
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integ…
▽ More
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integrating mode, the detectors remain photon noise limited over more than six orders of magnitude in absorbed power from 70 zW to 200 fW, with a limiting NEP of 4.6 x 10^-20 W/rtHz at 1 Hz. In addition, the detectors are highly stable with flat power spectra under optical load down to 1 mHz. Operational parameters of the detector are determined including the efficiency of conversion of the incident optical power into quasiparticles in the aluminum absorbing element and the quasiparticle self-recombination constant.
△ Less
Submitted 14 May, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Significant noise improvement in a Kinetic Inductance Phonon-Mediated detector by use of a wideband parametric amplifier
Authors:
Karthik Ramanathan,
Osmond Wen,
Taylor Aralis,
Ritoban Basu Thakur,
Bruce Bumble,
Yen-Yung Chang,
Peter K. Day,
Byeong Ho Eom,
Henry G. LeDuc,
Brandon J. Sandoval,
Ryan Stephenson,
Sunil R. Golwala
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers,…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers, are oftentimes limited in their sensitivity by low temperature amplifier noise introduced in the signal readout chain. We report here an effort to couple a wideband Kinetic Inductance Travelling Wave Parametric Amplifier (KI-TWPA), operated near the Standard Quantum Limit of minimal added amplifier noise, to sensors spanning a 70 MHz bandwidth at 3.5 GHz. This results in a ~5x improvement in the inferred detector energy resolution in the best sensor and highlights the potential of constructing O(100) meV resolving phonon-mediated particle detectors. We detail limitations introduced by lossy passive components, degraded RF responsivity, and microphysical noise sources like two-level systems (TLS), in achieving ultimate quantum-limited system noise levels.
△ Less
Submitted 8 February, 2024;
originally announced February 2024.
-
Frequency-domain multiplexing of SNSPDs with tunable superconducting resonators
Authors:
Sasha Sypkens,
Lorenzo Minutolo,
Sahil Patel,
Emanuel Knehr,
Alexander B. Walter,
Henry G. Leduc,
Lautaro Narváez,
Ralph Chamberlin,
Tracee Jamison-Hooks,
Matthew D. Shaw,
Peter K. Day,
Boris Korzh
Abstract:
This work culminates in a demonstration of an alternative Frequency Domain Multiplexing (FDM) scheme for Superconducting Nanowire Single-Photon Detectors (SNSPDs) using the Kinetic inductance Parametric UP-converter (KPUP) made out of NbTiN. There are multiple multiplexing architectures for SNSPDs that are already in use, but FDM could prove superior in applications where the operational bias curr…
▽ More
This work culminates in a demonstration of an alternative Frequency Domain Multiplexing (FDM) scheme for Superconducting Nanowire Single-Photon Detectors (SNSPDs) using the Kinetic inductance Parametric UP-converter (KPUP) made out of NbTiN. There are multiple multiplexing architectures for SNSPDs that are already in use, but FDM could prove superior in applications where the operational bias currents are very low, especially for mid- and far-infrared SNSPDs. Previous FDM schemes integrated the SNSPD within the resonator, while in this work we use an external resonator, which gives more flexibility to optimize the SNSPD architecture. The KPUP is a DC-biased superconducting resonator in which a nanowire is used as its inductive element to enable sensitivity to current perturbations. When coupled to an SNSPD, the KPUP can be used to read out current pulses on the few $μ$A scale. The KPUP is made out of NbTiN, which has high non-linear kinetic inductance for increased sensitivity at higher current bias and high operating temperature. Meanwhile, the SNSPD is made from WSi, which is a popular material for broadband SNSPDs. To read out the KPUP and SNSPD array, a software-defined radio platform and a graphics processing unit are used. Frequency Domain Multiplexed SNSPDs have applications in astronomy, remote sensing, exoplanet science, dark matter detection, and quantum sensing.
△ Less
Submitted 30 January, 2024;
originally announced January 2024.
-
Parallel-Plate Capacitor Titanium Nitride Kinetic Inductance Detectors for Infrared Astronomy
Authors:
Joanna Perido,
Peter K. Day,
Andrew D. Beyer,
Nicholas F. Cothard,
Steven Hailey-Dunsheath,
Henry G. Leduc,
Byeong H. Eom,
Jason Glenn
Abstract:
The Balloon Experiment for Galactic INfrared Science (BEGINS) is a concept for a sub-orbital observatory that will operate from $λ$ = 25-250 $μ$m to characterize dust in the vicinity of high-mass stars. The mission's sensitivity requirements will be met by utilizing arrays of 1,840 lens-coupled, lumped-element kinetic inductance detectors (KIDs) operating at 300 mK. Each KID will consist of a tita…
▽ More
The Balloon Experiment for Galactic INfrared Science (BEGINS) is a concept for a sub-orbital observatory that will operate from $λ$ = 25-250 $μ$m to characterize dust in the vicinity of high-mass stars. The mission's sensitivity requirements will be met by utilizing arrays of 1,840 lens-coupled, lumped-element kinetic inductance detectors (KIDs) operating at 300 mK. Each KID will consist of a titanium nitride (TiN) parallel strip absorbing inductive section and parallel plate capacitor (PPC) deposited on a silicon (Si) substrate. The PPC geometry allows for reduction of the pixel spacing. At the BEGINS focal plane the detectors require optical NEPs from $2\times10^{-16}$ W/$\sqrt{\textrm{Hz}}$ to $6\times10^{-17}$ W/$\sqrt{\textrm{Hz}}$ from 25-250 $μ$m for optical loads ranging from 4 pW to 10 pW. We present the design, optical performance and quasiparticle lifetime measurements of a prototype BEGINS KID array at 25 $μ$m when coupled to Fresnel zone plate lenses. For our optical set up and the absorption efficiency of the KIDs, the electrical NEP requirement at 25 $μ$m is $7.6\times10^{-17}$ W/$\sqrt{\textrm{Hz}}$ for an absorbed optical power of 0.36 pW. We find that over an average of five resonators the the detectors are photon noise limited down to about 200 fW, with a limiting NEP of about $7.4\times10^{-17}$ W/$\sqrt{\textrm{Hz}}$.
△ Less
Submitted 28 December, 2023;
originally announced December 2023.
-
High-sensitivity Kinetic Inductance Detector Arrays for the Probe Far-Infrared Mission for Astrophysics
Authors:
Logan Foote,
Chris Albert,
Jochem Baselmans,
Andrew Beyer,
Nicholas Cothard,
Peter Day,
Steven Hailey-Dunsheath,
Pierre Echternach,
Reinier Janssen,
Elijah Kane,
Henry Leduc,
Lun-Jun Liu,
Hien Nguyen,
Joanna Perido,
Jason Glenn,
Jonas Zmuidzinas,
Charles,
Bradford
Abstract:
Far-infrared (far-IR) astrophysics missions featuring actively cooled telescopes will offer orders of magnitude observing speed improvement at wavelengths where galaxies and forming planetary systems emit most of their light. The PRobe far-Infrared Mission for Astrophysics (PRIMA), which is currently under study, emphasizes low and moderate resolution spectroscopy throughout the far-IR. Full utili…
▽ More
Far-infrared (far-IR) astrophysics missions featuring actively cooled telescopes will offer orders of magnitude observing speed improvement at wavelengths where galaxies and forming planetary systems emit most of their light. The PRobe far-Infrared Mission for Astrophysics (PRIMA), which is currently under study, emphasizes low and moderate resolution spectroscopy throughout the far-IR. Full utilization of PRIMA's cold telescope requires far-IR detector arrays with per-pixel noise equivalent powers (NEPs) at or below 1 x 10-19 W/rtHz. We are develo** low-volume Aluminum kinetic inductance detector (KID) arrays to reach these sensitivities. We will present on the development of our long-wavelength (210 um) array approach, with a focus on multitone measurements of our 1,008-pixel arrays. We measure an NEP below 1 x 10-19 W/rtHz for 73 percent of our pixels.
△ Less
Submitted 29 May, 2024; v1 submitted 3 November, 2023;
originally announced November 2023.
-
Wideband Direct Detection Constraints on Hidden Photon Dark Matter with the QUALIPHIDE Experiment
Authors:
Karthik Ramanathan,
Nikita Klimovich,
Ritoban Basu Thakur,
Byeong Ho Eom,
Henry G. LeDuc,
Shibo Shu,
Andrew D. Beyer,
Peter K. Day
Abstract:
We report direction detection constraints on the presence of hidden photon dark matter with masses between 20-30 ueV using a cryogenic emitter-receiver-amplifier spectroscopy setup designed as the first iteration of QUALIPHIDE (QUantum LImited PHotons In the Dark Experiment). A metallic dish sources conversion photons from hidden photon kinetic mixing onto a horn antenna which is coupled to a C-ba…
▽ More
We report direction detection constraints on the presence of hidden photon dark matter with masses between 20-30 ueV using a cryogenic emitter-receiver-amplifier spectroscopy setup designed as the first iteration of QUALIPHIDE (QUantum LImited PHotons In the Dark Experiment). A metallic dish sources conversion photons from hidden photon kinetic mixing onto a horn antenna which is coupled to a C-band kinetic inductance traveling wave parametric amplifier, providing for near quantum-limited noise performance. We demonstrate a first probing of the kinetic mixing parameter "chi" to just above 10^-12 for the majority of hidden photon masses in this region. These results not only represent stringent constraints on new dark matter parameter space but are also the first demonstrated use of wideband quantum-limited amplification for astroparticle applications
△ Less
Submitted 7 September, 2022;
originally announced September 2022.
-
Nonlinearity and wideband parametric amplification in an NbTiN microstrip transmission line
Authors:
Shibo Shu,
Nikita Klimovich,
Byeong Ho Eom,
Andrew Beyer,
Ritoban Basu Thakur,
Henry Leduc,
Peter Day
Abstract:
The nonlinear response associated with the current dependence of the superconducting kinetic inductance was studied in capacitively shunted NbTiN microstrip transmission lines. It was found that the inductance per unit length of one microstrip line could be changed by up to 20% by applying a DC current, corresponding to a single pass time delay of 0.7 ns. To investigate nonlinear dissipation, Brag…
▽ More
The nonlinear response associated with the current dependence of the superconducting kinetic inductance was studied in capacitively shunted NbTiN microstrip transmission lines. It was found that the inductance per unit length of one microstrip line could be changed by up to 20% by applying a DC current, corresponding to a single pass time delay of 0.7 ns. To investigate nonlinear dissipation, Bragg reflectors were placed on either end of a section of this type of transmission line, creating resonances over a range of frequencies. From the change in the resonance linewidth and amplitude with DC current, the ratio of the reactive to the dissipative response of the line was found to be 788. The low dissipation makes these transmission lines suitable for a number of applications that are microwave and millimeter-wave band analogues of nonlinear optical processes. As an example, by applying a millimeter-wave pump tone, very wide band parametric amplification was observed between about 3 and 34 GHz. Use as a current variable delay line for an on-chip millimeter-wave Fourier transform spectrometer is also considered.
△ Less
Submitted 19 May, 2021; v1 submitted 28 February, 2021;
originally announced March 2021.
-
Improving the dynamic range of single photon counting kinetic inductance detectors
Authors:
Nicholas Zobrist,
Nikita Klimovich,
Byeong Ho Eom,
Grégoire Coiffard,
Miguel Daal,
Noah Swimmer,
Sarah Steiger,
Bruce Bumble,
Henry G. LeDuc,
Peter Day,
Benjamin A. Mazin
Abstract:
We develop a simple coordinate transformation which can be employed to compensate for the nonlinearity introduced by a Microwave Kinetic Inductance Detector's (MKID) homodyne readout scheme. This coordinate system is compared to the canonically used polar coordinates and is shown to improve the performance of the filtering method often used to estimate a photon's energy. For a detector where the c…
▽ More
We develop a simple coordinate transformation which can be employed to compensate for the nonlinearity introduced by a Microwave Kinetic Inductance Detector's (MKID) homodyne readout scheme. This coordinate system is compared to the canonically used polar coordinates and is shown to improve the performance of the filtering method often used to estimate a photon's energy. For a detector where the coordinate nonlinearity is primarily responsible for limiting its resolving power, this technique leads to increased dynamic range, which we show by applying the transformation to data from a hafnium MKID designed to be sensitive to photons with wavelengths in the 800 to 1300 nm range. The new coordinates allow the detector to resolve photons with wavelengths down to 400 nm, raising the resolving power at that wavelength from 6.8 to 17.
△ Less
Submitted 9 December, 2020;
originally announced December 2020.
-
Wide-band Parametric Amplifier Readout and Resolution of Optical Microwave Kinetic Inductance Detectors
Authors:
Nicholas Zobrist,
Byeong Ho Eom,
Peter Day,
Benjamin A. Mazin,
Seth R. Meeker,
Bruce Bumble,
Henry G. LeDuc,
Gérgoire Coiffard,
Paul Szypryt,
Neelay Fruitwala,
Isabel Lipartito,
Clint Bockstiegel
Abstract:
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based trav…
▽ More
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based traveling wave parametric amplifier can be used for this application and reaches the quantum limit. The total system noise for this readout scheme was equal to ~2.1 in units of quanta. For incident photons in the 800 to 1300 nm range, the amplifier increased the average resolving power of the detector from ~6.7 to 9.3 at which point the resolution becomes limited by noise on the pulse height of the signal. Noise measurements suggest that a resolving power of up to 25 is possible if redesigned detectors can remove this additional noise source.
△ Less
Submitted 6 July, 2019;
originally announced July 2019.
-
Ultraviolet, Optical, and Near-IR Microwave Kinetic Inductance Detector Materials Developments
Authors:
P. Szypryt,
B. A. Mazin,
B. Bumble,
H. G. Leduc,
L. Baker
Abstract:
We have fabricated 2024 pixel microwave kinetic inductance detector (MKID) arrays in the ultraviolet/optical/near-IR (UVOIR) regime that are currently in use in astronomical instruments. In order to make MKIDs desirable for novel instruments, larger arrays with nearly perfect yield need to be fabricated. As array size increases, however, the percent yield often decreases due to frequency collision…
▽ More
We have fabricated 2024 pixel microwave kinetic inductance detector (MKID) arrays in the ultraviolet/optical/near-IR (UVOIR) regime that are currently in use in astronomical instruments. In order to make MKIDs desirable for novel instruments, larger arrays with nearly perfect yield need to be fabricated. As array size increases, however, the percent yield often decreases due to frequency collisions in the readout. The per-pixel performance must also be improved, namely the energy resolution. We are investigating ways to reduce frequency collisions and to improve the per pixel performance of our devices through new superconducting material systems and fabrication techniques. There are two main routes that we are currently exploring. First, we are attempting to create more uniform titanium nitride films through the use of atomic layer deposition rather than the more traditional sputtering method. In addition, we are experimenting with completely new material systems for MKIDs, such as platinum silicide.
△ Less
Submitted 1 December, 2014;
originally announced December 2014.
-
Design and Testing of Kinetic Inductance Detectors Made of Titanium Nitride
Authors:
P. Diener,
H. G. Leduc,
S. J. C. Yates,
Y. J. Y. Lankwarden,
J. J. A. Baselmans
Abstract:
To use highly resistive material for Kinetic Inductance Detectors (KID), new designs have to be done, in part due to the impedance match needed between the KID chip and the whole 50 ohms readout circuit. Chips from two new hybrid designs, with an aluminum throughline coupled to titanium nitride microresonators, have been measured and compared to a TiN only chip. In the hybrid chips, parasitic temp…
▽ More
To use highly resistive material for Kinetic Inductance Detectors (KID), new designs have to be done, in part due to the impedance match needed between the KID chip and the whole 50 ohms readout circuit. Chips from two new hybrid designs, with an aluminum throughline coupled to titanium nitride microresonators, have been measured and compared to a TiN only chip. In the hybrid chips, parasitic temperature dependent box resonances are absent. The dark KID properties have been measured in a large set of resonators. A surprisingly long lifetime, up to 5.6 ms is observed in a few KIDs. For the other more reproducible devices, the mean electrical Noise Equivalent Power is 5.4 10-19 W.Hz1/2.
△ Less
Submitted 17 September, 2013;
originally announced September 2013.
-
A titanium-nitride near-infrared kinetic inductance photon-counting detector and its anomalous electrodynamics
Authors:
J. Gao,
M. R. Visser,
M. O. Sandberg,
F. C. S. da Silva,
S. W. Nam,
D. P. Pappas,
K. D. Irwin,
D. S. Wisbey,
E. Langman,
S. R. Meeker,
B. A. Mazin,
H. G. Leduc,
J. Zmuidzinas
Abstract:
We demonstrate single-photon counting at 1550 nm with titanium-nitride (TiN) microwave kinetic inductance detectors. Energy resolution of 0.4 eV and arrival-time resolution of 1.2 microseconds are achieved. 0-, 1-, 2-photon events are resolved and shown to follow Poisson statistics. We find that the temperature-dependent frequency shift deviates from the Mattis-Bardeen theory, and the dissipation…
▽ More
We demonstrate single-photon counting at 1550 nm with titanium-nitride (TiN) microwave kinetic inductance detectors. Energy resolution of 0.4 eV and arrival-time resolution of 1.2 microseconds are achieved. 0-, 1-, 2-photon events are resolved and shown to follow Poisson statistics. We find that the temperature-dependent frequency shift deviates from the Mattis-Bardeen theory, and the dissipation response shows a shorter decay time than the frequency response at low temperatures. We suggest that the observed anomalous electrodynamics may be related to quasiparticle traps or subgap states in the disordered TiN films. Finally, the electron density-of-states is derived from the pulse response.
△ Less
Submitted 3 August, 2012;
originally announced August 2012.
-
Crosstalk Reduction for Superconducting Microwave Resonator Arrays
Authors:
Omid Noroozian,
Peter K. Day,
Byeong Ho Eom,
Henry G. Leduc,
Jonas Zmuidzinas
Abstract:
Large-scale arrays of Microwave Kinetic Inductance Detectors (MKIDs) are attractive candidates for use in imaging instruments for next generation submillimeter-wave telescopes such as CCAT. We have designed and fabricated tightly packed ~250-pixel MKID arrays using lumped-element resonators etched from a thin layer of superconducting TiNx deposited on a silicon substrate. The high pixel packing de…
▽ More
Large-scale arrays of Microwave Kinetic Inductance Detectors (MKIDs) are attractive candidates for use in imaging instruments for next generation submillimeter-wave telescopes such as CCAT. We have designed and fabricated tightly packed ~250-pixel MKID arrays using lumped-element resonators etched from a thin layer of superconducting TiNx deposited on a silicon substrate. The high pixel packing density in our initial design resulted in large microwave crosstalk due to electromagnetic coupling between the resonators. Our second design eliminates this problem by adding a grounding shield and using a double-wound geometry for the meander inductor to allow conductors with opposite polarity to be in close proximity. In addition, the resonator frequencies are distributed in a checkerboard pattern across the array. We present details for the two resonator and array designs and describe a circuit model for the full array that predicts the distribution of resonator frequencies and the crosstalk level. We also show results from a new experimental technique that conveniently measures crosstalk without the need for an optical setup. Our results reveal an improvement in crosstalk from 57% in the initial design down to \leq 2% in the second design. The general procedure and design guidelines in this work are applicable to future large arrays employing microwave resonators.
△ Less
Submitted 25 June, 2012;
originally announced June 2012.
-
Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors
Authors:
D. C. Moore,
S. R. Golwala,
B. Bumble,
B. Cornell,
P. K. Day,
H. G. LeDuc,
J. Zmuidzinas
Abstract:
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allows the location of the interaction to be determined with < 1 mm precision at 30 keV. Using this position information, variations…
▽ More
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allows the location of the interaction to be determined with < 1 mm precision at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of σ_E = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly-pixelized athermal phonon sensors for ~1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to next-generation rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering.
△ Less
Submitted 10 June, 2012; v1 submitted 20 March, 2012;
originally announced March 2012.
-
Titanium Nitride Films for Ultrasensitive Microresonator Detectors
Authors:
Henry G. Leduc,
Bruce Bumble,
Peter K. Day,
Anthony D. Turner,
Byeong Ho Eom,
Sunil Golwala,
David C. Moore,
Omid Noroozian,
Jonas Zmuidzinas,
Jiansong Gao,
Benjamin A. Mazin,
Sean McHugh,
Andrew Merrill
Abstract:
Titanium nitride (TiNx) films are ideal for use in superconducting microresonator detectors because: a) the critical temperature varies with composition (0 < Tc < 5 K); b) the normal-state resistivity is large, ρ_n ~ 100 $μ$Ohm cm, facilitating efficient photon absorption and providing a large kinetic inductance and detector responsivity; and c) TiN films are very hard and mechanically robust. Res…
▽ More
Titanium nitride (TiNx) films are ideal for use in superconducting microresonator detectors because: a) the critical temperature varies with composition (0 < Tc < 5 K); b) the normal-state resistivity is large, ρ_n ~ 100 $μ$Ohm cm, facilitating efficient photon absorption and providing a large kinetic inductance and detector responsivity; and c) TiN films are very hard and mechanically robust. Resonators using reactively sputtered TiN films show remarkably low loss (Q_i > 10^7) and have noise properties similar to resonators made using other materials, while the quasiparticle lifetimes are reasonably long, 10-200 $μ$s. TiN microresonators should therefore reach sensitivities well below 10^-19 WHz^(-1/2).
△ Less
Submitted 9 August, 2010; v1 submitted 29 March, 2010;
originally announced March 2010.
-
Two-level system noise reduction for Microwave Kinetic Inductance Detectors
Authors:
Omid Noroozian,
Jiansong Gao,
Jonas Zmuidzinas,
Henry G. LeDuc,
Benjamin A. Mazin
Abstract:
Noise performance is one of the most crucial aspects of any detector. Superconducting Microwave Kinetic Inductance Detectors (MKIDs) have an "excess" frequency noise that shows up as a small time dependent jitter of the resonance frequency characterized by the frequency noise power spectrum measured in units of Hz^2/Hz. Recent studies have shown that this noise almost certainly originates from a…
▽ More
Noise performance is one of the most crucial aspects of any detector. Superconducting Microwave Kinetic Inductance Detectors (MKIDs) have an "excess" frequency noise that shows up as a small time dependent jitter of the resonance frequency characterized by the frequency noise power spectrum measured in units of Hz^2/Hz. Recent studies have shown that this noise almost certainly originates from a surface layer of two-level system (TLS) defects on the metallization or substrate. Fluctuation of these TLSs introduces noise in the resonator due to coupling of the TLS electric dipole moments to the resonator's electric field. Motivated by a semi-empirical quantitative theory of this noise mechanism, we have designed and tested new resonator geometries in which the high-field "capacitive" portion of the CPW resonator is replaced by an interdigitated capacitor (IDC) structure with 10 - 20 micron electrode spacing, as compared to the 2 micron spacing used for our more conventional CPW resonators. Measurements show that this new IDC design has dramatically lower TLS noise, currently by about a factor of ~29 in terms of the frequency noise power spectrum, corresponding to an improvement of about a factor of 29^(1/2) in NEP. These new devices are replacing the CPW resonators in our next design iteration in progress for MKIDCam. Opportunities and prospects for future reduction of the TLS noise will be discussed.
△ Less
Submitted 10 September, 2009;
originally announced September 2009.