Measurement of the cluster position resolution of the Belle II Silicon Vertex Detector
Authors:
R. Leboucher,
K. Adamczyk,
L. Aggarwal,
H. Aihara,
T. Aziz,
S. Bacher,
S. Bahinipati,
G. Batignani,
J. Baudot,
P. K. Behera,
S. Bettarini,
T. Bilka,
A. Bozek,
F. Buchsteiner,
G. Casarosa,
L. Corona,
T. Czank,
S. B. Das,
G. Dujany,
C. Finck,
F. Forti,
M. Friedl,
A. Gabrielli,
E. Ganiev,
B. Gobbo
, et al. (56 additional authors not shown)
Abstract:
The Silicon Vertex Detector (SVD), with its four double-sided silicon strip sensor layers, is one of the two vertex sub-detectors of Belle II operating at SuperKEKB collider (KEK, Japan). Since 2019 and the start of the data taking, the SVD has demonstrated a reliable and highly efficient operation, even running in an environment with harsh beam backgrounds that are induced by the world's highest…
▽ More
The Silicon Vertex Detector (SVD), with its four double-sided silicon strip sensor layers, is one of the two vertex sub-detectors of Belle II operating at SuperKEKB collider (KEK, Japan). Since 2019 and the start of the data taking, the SVD has demonstrated a reliable and highly efficient operation, even running in an environment with harsh beam backgrounds that are induced by the world's highest instantaneous luminosity. In order to provide the best quality track reconstruction with an efficient pattern recognition and track fit, and to correctly propagate the uncertainty on the hit's position to the track parameters, it is crucial to precisely estimate the resolution of the cluster position measurement. Several methods for estimating the position resolution directly from the data will be discussed.
△ Less
Submitted 7 September, 2022;
originally announced September 2022.
The Silicon Vertex Detector of the Belle II Experiment
Authors:
G. Dujany,
K. Adamczyk,
L. Aggarwal,
H. Aihara,
T. Aziz,
S. Bacher,
S. Bahinipati,
G. Batignani,
J. Baudot,
P. K. Behera,
S. Bettarini,
T. Bilka,
A. Bozek,
F. Buchsteiner,
G. Casarosa,
L. Corona,
T. Czank,
S. B. Das,
C. Finck,
F. Forti,
M. Friedl,
A. Gabrielli,
E. Ganiev,
B. Gobbo,
S. Halder
, et al. (56 additional authors not shown)
Abstract:
In 2019 the Belle II experiment started data taking at the asymmetric SuperKEKB collider (KEK, Japan) operating at the Y(4S) resonance. Belle II will search for new physics beyond the Standard Model by collecting an integrated luminosity of 50~ab$^{-1}$. The silicon vertex detector (SVD), consisting of four layers of double-sided silicon strip sensors, is one of the two vertex sub-detectors. The S…
▽ More
In 2019 the Belle II experiment started data taking at the asymmetric SuperKEKB collider (KEK, Japan) operating at the Y(4S) resonance. Belle II will search for new physics beyond the Standard Model by collecting an integrated luminosity of 50~ab$^{-1}$. The silicon vertex detector (SVD), consisting of four layers of double-sided silicon strip sensors, is one of the two vertex sub-detectors. The SVD extrapolates the tracks to the inner pixel detector (PXD) with enough precision to correctly identify hits in the PXD belonging to the track. In addition the SVD has standalone tracking capability and utilizes ionization to enhance particle identification in the low momentum region. The SVD is operating reliably and with high efficiency, despite exposure to the harsh beam background of the highest peak-luminosity collider ever built. High signal-to-noise ratio and hit efficiency have been measured, as well as the spatial resolution; all these quantities show excellent stability over time. Data-simulation agreement on cluster properties has recently been improved through a careful tuning of the simulation. The precise hit-time resolution can be exploited to reject out-of-time hits induced by beam background, which will make the SVD more robust against higher levels of background. During the first three years of running, radiation damage effects on strip noise, sensor currents and depletion voltage have been observed, as well as some coupling capacitor failure due to intense radiation bursts. None of these effects cause significant degradation in the detector performance.
△ Less
Submitted 18 March, 2022; v1 submitted 26 November, 2021;
originally announced November 2021.