-
SENSEI: First Direct-Detection Results on sub-GeV Dark Matter from SENSEI at SNOLAB
Authors:
SENSEI Collaboration,
Prakruth Adari,
Itay M. Bloch,
Ana M. Botti,
Mariano Cababie,
Gustavo Cancelo,
Brenda A. Cervantes-Vergara,
Michael Crisler,
Miguel Daal,
Ansh Desai,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Stephen E. Holland,
Yonatan Kehat,
Yaron Korn,
Ian Lawson,
Steffon Luoma,
Aviv Orly,
Santiago E. Perez,
Dario Rodrigues,
Nathan A. Saffold,
Silvia Scorza
, et al. (12 additional authors not shown)
Abstract:
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 elect…
▽ More
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our "hot-pixel" mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.
△ Less
Submitted 20 December, 2023;
originally announced December 2023.
-
Searching for millicharged particles with 1 kg of Skipper-CCDs using the NuMI beam at Fermilab
Authors:
Santiago Perez,
Dario Rodrigues,
Juan Estrada,
Roni Harnik,
Zhen Liu,
Brenda A. Cervantes-Vergara,
Juan Carlos D'Olivo,
Ryan D. Plestid,
Javier Tiffenberg,
Tien-Tien Yu,
Alexis Aguilar-Arevalo,
Fabricio Alcalde-Bessia,
Nicolas Avalos,
Oscar Baez,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Ana Botti,
Gustavo Cancelo,
Nuria Castelló-Mor,
Alvaro E. Chavarria,
Claudio R. Chavez,
Fernando Chierchie,
Juan Manuel De Egea,
Cyrus Dreyer
, et al. (35 additional authors not shown)
Abstract:
Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab.…
▽ More
Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab. mCPs would be produced at low energies through photon-mediated processes from decays of scalar, pseudoscalar, and vector mesons, or direct Drell-Yan productions. Estimates show that the OIT would be a world-leading probe for mCPs in the MeV mass range.
△ Less
Submitted 2 December, 2023; v1 submitted 17 April, 2023;
originally announced April 2023.
-
Skipper-CCD Sensors for the Oscura Experiment: Requirements and Preliminary Tests
Authors:
Brenda A. Cervantes-Vergara,
Santiago Perez,
Juan Estrada,
Ana Botti,
Claudio R. Chavez,
Fernando Chierchie,
Nathan Saffold,
Alexis Aguilar-Arevalo,
Fabricio Alcalde-Bessia,
Nicolás Avalos,
Oscar Baez,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Gustavo Cancelo,
Nuria Castelló-Mor,
Alvaro E. Chavarria,
Juan Manuel De Egea,
Juan Carlos D'Olivo,
Cyrus Dreyer,
Alex Drlica-Wagner,
Rouven Essig,
Ezequiel Estrada,
Erez Etzion,
Paul Grylls
, et al. (30 additional authors not shown)
Abstract:
Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal…
▽ More
Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru. In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.
△ Less
Submitted 11 April, 2024; v1 submitted 10 April, 2023;
originally announced April 2023.
-
The DAMIC-M Experiment: Status and First Results
Authors:
I. Arnquist,
N. Avalos,
P. Bailly,
D. Baxter,
X. Bertou,
M. Bogdan,
C. Bourgeois,
J. Brandt,
A. Cadiou,
N. Castelló-Mor,
A. E. Chavarria,
M. Conde,
N. J. Corso,
J. Cortabitarte Gutiérrez,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
R. Desani,
M. Dhellot,
J-J. Dormard,
J. Duarte-Campderros,
E. Estrada,
D. Florin,
N. Gadola
, et al. (47 additional authors not shown)
Abstract:
The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV…
▽ More
The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called "hidden sector." A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.
△ Less
Submitted 25 November, 2022; v1 submitted 11 October, 2022;
originally announced October 2022.
-
Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection
Authors:
D. Norcini,
N. Castello-Mor,
D. Baxter,
N. J. Corso,
J. Cuevas-Zepeda,
C. De Dominicis,
A. Matalon,
S. Munagavalasa,
S. Paul,
P. Privitera,
K. Ramanathan,
R. Smida,
R. Thomas,
R. Yajur,
A. E. Chavarria,
K. McGuire,
P. Mitra,
A. Piers,
M. Settimo,
J. Cortabitarte Gutierrez,
J. Duarte-Campderros,
A. Lantero-Barreda,
A. Lopez-Virto,
I. Vila,
R. Vilar
, et al. (19 additional authors not shown)
Abstract:
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $γ$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a…
▽ More
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $γ$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $γ$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$ $initio$ calculations originally developed for X-ray absorption spectroscopy.
△ Less
Submitted 2 July, 2022;
originally announced July 2022.
-
Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors
Authors:
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
D. Durnford,
S. Fallows,
J. Farine,
R. Filgas,
A. García-Viltres,
F. Girard,
G. Giroux,
O. Harris,
E. W. Hoppe,
C. M. Jackson,
M. **,
C. B. Krauss
, et al. (32 additional authors not shown)
Abstract:
The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct…
▽ More
The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.
△ Less
Submitted 7 November, 2022; v1 submitted 11 May, 2022;
originally announced May 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Characterization of the background spectrum in DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
I. Arnquist,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
N. Corso,
E. Darragh-Ford,
M. L. Di Vacri,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
A. Piers,
P. Privitera,
K. Ramanathan
, et al. (9 additional authors not shown)
Abstract:
We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed GEANT4-based particle-transport simulation to model both bulk and surface backgrounds from natural radioactivity down to 50 eV$_{\text{ee}}$. We fit to the energy…
▽ More
We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed GEANT4-based particle-transport simulation to model both bulk and surface backgrounds from natural radioactivity down to 50 eV$_{\text{ee}}$. We fit to the energy and depth distributions of the observed ionization events to differentiate and constrain possible background sources, for example, bulk $^{3}$H from silicon cosmogenic activation and surface $^{210}$Pb from radon plate-out. We observe the bulk background rate of the DAMIC at SNOLAB CCDs to be as low as $3.1 \pm 0.6$ counts kg$^{-1}$ day$^{-1}$ keV$_{\text{ee}}^{-1}$, making it the most sensitive silicon dark matter detector. Finally, we discuss the properties of a statistically significant excess of events over the background model with energies below 200 eV$_{\text{ee}}$.
△ Less
Submitted 24 March, 2022; v1 submitted 25 October, 2021;
originally announced October 2021.
-
Optical calibration of the SNO+ detector in the water phase with deployed sources
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
F. Barão,
N. Barros,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
M. Chen,
O. Chkvorets,
B. Cleveland,
D. Cookman,
J. Corning,
M. A. Cox,
C. Deluce,
M. M. Depatie
, et al. (98 additional authors not shown)
Abstract:
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light…
▽ More
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. The calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.
△ Less
Submitted 4 October, 2021; v1 submitted 7 June, 2021;
originally announced June 2021.
-
The SNO+ Experiment
Authors:
SNO+ Collaboration,
:,
V. Albanese,
R. Alves,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
S. Back,
F. Barão,
Z. Barnard,
A. Barr,
N. Barros,
D. Bartlett,
R. Bayes,
C. Beaudoin,
E. W. Beier,
G. Berardi,
A. Bialek,
S. D. Biller,
E. Blucher
, et al. (229 additional authors not shown)
Abstract:
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of pr…
▽ More
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of process plants, commissioning efforts, electronics upgrades, data acquisition systems, and calibration techniques. The SNO+ collaboration is reusing the acrylic vessel, PMT array, and electronics of the SNO detector, having made a number of experimental upgrades and essential adaptations for use with the liquid scintillator. With low backgrounds and a low energy threshold, the SNO+ collaboration will also pursue a rich physics program beyond the search for $0νββ$ decay, including studies of geo- and reactor antineutrinos, supernova and solar neutrinos, and exotic physics such as the search for invisible nucleon decay. The SNO+ approach to the search for $0νββ$ decay is scalable: a future phase with high $^{130}$Te-loading is envisioned to probe an effective Majorana mass in the inverted mass ordering region.
△ Less
Submitted 25 August, 2021; v1 submitted 23 April, 2021;
originally announced April 2021.
-
Development, characterisation, and deployment of the SNO+ liquid scintillator
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
D. Bartlett,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
D. Braid,
E. Caden,
E. J. Callaghan,
J. Caravaca
, et al. (201 additional authors not shown)
Abstract:
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity,…
▽ More
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity, ease of handling, and logistical availability. Its properties have been extensively characterized and are presented here. This liquid scintillator is now used in several neutrino physics experiments in addition to SNO+.
△ Less
Submitted 21 February, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Measurement of the bulk radioactive contamination of detector-grade silicon with DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
E. Darragh-Ford,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
A. Piers,
P. Privitera,
K. Ramanathan,
J. Da Rocha,
Y. Sarkis,
M. Settimo
, et al. (6 additional authors not shown)
Abstract:
We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC at SNOLAB experiment. We utilize the exquisite spatial resolution of CCDs to discriminate between $α$ and $β$ decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated $β$ decays, we measure a bulk radioactive conta…
▽ More
We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC at SNOLAB experiment. We utilize the exquisite spatial resolution of CCDs to discriminate between $α$ and $β$ decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated $β$ decays, we measure a bulk radioactive contamination of $^{32}$Si in the CCDs of $140 \pm 30$ $μ$Bq/kg, and place an upper limit on bulk $^{210}$Pb of $< 160~μ$Bq/kg. Using similar analyses of spatially-correlated bulk $α$ decays, we set limits of $< 11$ $μ$Bq/kg (0.9 ppt) on $^{238}$U and of $< 7.3$ $μ$Bq/kg (1.8 ppt) on $^{232}$Th. The ability of DAMIC CCDs to identify and reject spatially-coincident backgrounds, particularly from $^{32}$Si, has significant implications for the next generation of silicon-based dark matter experiments, where $β$'s from $^{32}$Si decay will likely be a dominant background. This capability demonstrates the readiness of the CCD technology to achieve kg-scale dark matter sensitivity.
△ Less
Submitted 23 July, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Measurement of neutron-proton capture in the SNO+ water phase
Authors:
The SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
N. Barros,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
D. Chauhan,
M. Chen,
O. Chkvorets,
B. Cleveland,
M. A. Cox,
M. M. Depatie,
J. Dittmer
, et al. (108 additional authors not shown)
Abstract:
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.…
▽ More
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.2-MeV capture $γ$ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. In addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb.
△ Less
Submitted 13 July, 2020; v1 submitted 24 February, 2020;
originally announced February 2020.
-
Constraints on Light Dark Matter Particles Interacting with Electrons from DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
E. Darragh-Ford,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
V. B. B. Mello,
P. Mitra,
Y. S. Mobarak,
J. Molina,
S. Paul,
A. Piers,
P. Privitera
, et al. (9 additional authors not shown)
Abstract:
We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2-6$\times$10$^{-22}$ A cm$^{-2}$. We evaluate the charge distribution of pixels that collect $<10~\rm{e^-}$ for contributions beyond the leakage current that may be attribute…
▽ More
We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2-6$\times$10$^{-22}$ A cm$^{-2}$. We evaluate the charge distribution of pixels that collect $<10~\rm{e^-}$ for contributions beyond the leakage current that may be attributed to dark matter interactions. Constraints are placed on so-far unexplored parameter space for dark matter masses between 0.6 and 100 MeV$c^{-2}$. We also present new constraints on hidden-photon dark matter with masses in the range $1.2$-$30$ eV$c^{-2}$.
△ Less
Submitted 8 April, 2020; v1 submitted 29 July, 2019;
originally announced July 2019.
-
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
S. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
R. Filgas
, et al. (54 additional authors not shown)
Abstract:
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by…
▽ More
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.
△ Less
Submitted 25 November, 2020; v1 submitted 29 May, 2019;
originally announced May 2019.
-
Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas
, et al. (47 additional authors not shown)
Abstract:
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total backgr…
▽ More
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.
△ Less
Submitted 11 February, 2019;
originally announced February 2019.
-
Search for invisible modes of nucleon decay in water with the SNO+ detector
Authors:
SNO+ Collaboration,
:,
M. Anderson,
S. Andringa,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
D. Bartlett,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
D. Braid,
E. Caden,
E. J. Callaghan,
J. Caravaca,
J. Carvalho
, et al. (173 additional authors not shown)
Abstract:
This paper reports results from a search for nucleon decay through 'invisible' modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently de-excite, often emitting detectable gamma rays. A search for such gamma rays yields limits of…
▽ More
This paper reports results from a search for nucleon decay through 'invisible' modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently de-excite, often emitting detectable gamma rays. A search for such gamma rays yields limits of $2.5 \times 10^{29}$ y at 90% Bayesian credibility level (with a prior uniform in rate) for the partial lifetime of the neutron, and $3.6 \times 10^{29}$ y for the partial lifetime of the proton, the latter a 70% improvement on the previous limit from SNO. We also present partial lifetime limits for invisible dinucleon modes of $1.3\times 10^{28}$ y for $nn$, $2.6\times 10^{28}$ y for $pn$ and $4.7\times 10^{28}$ y for $pp$, an improvement over existing limits by close to three orders of magnitude for the latter two.
△ Less
Submitted 13 December, 2018;
originally announced December 2018.
-
Develo** a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning
Authors:
B. Matusch,
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis
, et al. (48 additional authors not shown)
Abstract:
The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually develo** a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing…
▽ More
The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually develo** a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing formats and neural network architectures are applied to the task. First, they are optimized in a supervised learning context. Next, two novel semi-supervised learning algorithms are trained, and found to replicate the Acoustic Parameter (AP) discriminator previously used in PICO-60 with a mean of 97% accuracy.
△ Less
Submitted 27 November, 2018;
originally announced November 2018.
-
The search for neutron-antineutron oscillations at the Sudbury Neutrino Observatory
Authors:
SNO Collaboration,
B. Aharmim,
S. N. Ahmed,
A. E. Anthony,
N. Barros,
E. W. Beier,
A. Bellerive,
B. Beltran,
M. Bergevin,
S. D. Biller,
K. Boudjemline,
M. G. Boulay,
B. Cai,
Y. D. Chan,
D. Chauhan,
M. Chen,
B. T. Cleveland,
G. A. Cox,
X. Dai,
H. Deng,
J. A. Detwiler,
P. J. Doe,
G. Doucas,
P. -L. Drouin,
F. A. Duncan
, et al. (100 additional authors not shown)
Abstract:
Tests on $B-L$ symmetry breaking models are important probes to search for new physics. One proposed model with $Δ(B-L)=2$ involves the oscillations of a neutron to an antineutron. In this paper a new limit on this process is derived for the data acquired from all three operational phases of the Sudbury Neutrino Observatory experiment. The search was concentrated in oscillations occurring within t…
▽ More
Tests on $B-L$ symmetry breaking models are important probes to search for new physics. One proposed model with $Δ(B-L)=2$ involves the oscillations of a neutron to an antineutron. In this paper a new limit on this process is derived for the data acquired from all three operational phases of the Sudbury Neutrino Observatory experiment. The search was concentrated in oscillations occurring within the deuteron, and 23 events are observed against a background expectation of 30.5 events. These translate to a lower limit on the nuclear lifetime of $1.48\times 10^{31}$ years at 90% confidence level (CL) when no restriction is placed on the signal likelihood space (unbounded). Alternatively, a lower limit on the nuclear lifetime was found to be $1.18\times 10^{31}$ years at 90% CL when the signal was forced into a positive likelihood space (bounded). Values for the free oscillation time derived from various models are also provided in this article. This is the first search for neutron-antineutron oscillation with the deuteron as a target.
△ Less
Submitted 1 May, 2017;
originally announced May 2017.
-
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
P. Campion,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
G. Crowder,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas,
F. Girard
, et al. (37 additional authors not shown)
Abstract:
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less th…
▽ More
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than 1 event per month. A blind analysis of an efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 3.4 $\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one order of magnitude improvement from previous PICO results.
△ Less
Submitted 2 August, 2017; v1 submitted 24 February, 2017;
originally announced February 2017.
-
Final Results of the PICASSO Dark Matter Search Experiment
Authors:
E. Behnke,
M. Besnier,
P. Bhattacharjee,
X. Dai,
M. Das,
A. Davour,
F. Debris,
N. Dhungana,
J. Farine,
M. Fines-Neuschild,
S. Gagnebin,
G. Giroux,
E. Grace,
C. M. Jackson,
A. Kamaha,
C. B. Krauss,
M. Lafrenière,
M. Laurin,
I. Lawson,
L. Lessard,
I. Levine,
D. Marlisov,
J. -P. Martin,
P. Mitra,
A. J. Noble
, et al. (9 additional authors not shown)
Abstract:
The PICASSO dark matter search experiment operated an array of 32 superheated droplet detectors containing 3.0 kg of C$_{4}$F$_{10}$ and collected an exposure of 231.4 kgd at SNOLAB between March 2012 and January 2014. We report on the final results of this experiment which includes for the first time the complete data set and improved analysis techniques including \mbox{acoustic} localization to…
▽ More
The PICASSO dark matter search experiment operated an array of 32 superheated droplet detectors containing 3.0 kg of C$_{4}$F$_{10}$ and collected an exposure of 231.4 kgd at SNOLAB between March 2012 and January 2014. We report on the final results of this experiment which includes for the first time the complete data set and improved analysis techniques including \mbox{acoustic} localization to allow fiducialization and removal of higher activity regions within the detectors. No signal consistent with dark matter was observed. We set limits for spin-dependent interactions on protons of $σ_p^{SD}$~=~1.32~$\times$~10$^{-2}$~pb (90\%~C.L.) at a WIMP mass of 20 GeV/c$^{2}$. In the spin-independent sector we exclude cross sections larger than $σ_p^{SI}$~=~4.86~$\times$~10$^{-5 }$~pb~(90\% C.L.) in the region around 7 GeV/c$^{2}$. The pioneering efforts of the PICASSO experiment have paved the way forward for a next generation detector incorporating much of this technology and experience into larger mass bubble chambers.
△ Less
Submitted 23 March, 2017; v1 submitted 4 November, 2016;
originally announced November 2016.
-
Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
B. A. Cervantes Vergara,
A. E. Chavarria,
C. R. Chavez,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
R. Gaïor,
Y. Guandincerri,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
A. Letessier-Selvon,
J. Liao,
J. Molina,
J. R. Peña,
P. Privitera
, et al. (13 additional authors not shown)
Abstract:
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic…
▽ More
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic-scattering cross section are accordingly placed. A region of parameter space relevant to the potential signal from the CDMS-II Si experiment is excluded using the same target for the first time. This result obtained with a limited exposure demonstrates the potential to explore the low-mass WIMP region (<10 GeV/$c^{2}$) of the upcoming DAMIC100, a 100 g detector currently being installed in SNOLAB.
△ Less
Submitted 9 November, 2016; v1 submitted 25 July, 2016;
originally announced July 2016.
-
Improved dark matter search results from PICO-2L Run 2
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
M. Das,
F. Debris,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas,
M. Fines-Neuschild,
F. Girard,
G. Giroux
, et al. (33 additional authors not shown)
Abstract:
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nu…
▽ More
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nuclear-recoil event was observed in the data, consistent both with the predicted background rate from neutrons and with the observed rate of unambiguous multiple-bubble neutron scattering events. The chamber exhibits the same excellent electron-recoil and alpha decay rejection as was previously reported. These data provide the most stringent direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
△ Less
Submitted 25 March, 2016; v1 submitted 14 January, 2016;
originally announced January 2016.
-
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Authors:
C. Amole,
M. Ardid,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
S. Daley,
M. Das,
F. Debris,
N. Dhungana,
J. Farine,
I. Felis,
R. Filgas,
F. Girard,
G. Giroux,
A. Grandison
, et al. (34 additional authors not shown)
Abstract:
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays…
▽ More
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining $48.2\%$ of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.
△ Less
Submitted 3 March, 2016; v1 submitted 26 October, 2015;
originally announced October 2015.
-
The DAMIC dark matter experiment
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Bole,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarria,
J. R. T. de Mello Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera,
Y. Sarkis
, et al. (8 additional authors not shown)
Abstract:
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in ver…
▽ More
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in very effective background identification techniques. The experiment has a unique sensitivity to dark matter particles with masses below 10 GeV/c$^2$. Previous results have demonstrated the potential of this technology, motivating the construction of DAMIC100, a 100 grams silicon target detector currently being installed at SNOLAB. In this contribution, the mode of operation and unique imaging capabilities of the CCDs, and how they may be exploited to characterize and suppress backgrounds will be discussed, as well as physics results after one year of data taking.
△ Less
Submitted 7 October, 2015;
originally announced October 2015.
-
Status of the DAMIC direct dark matter search experiment
Authors:
DAMIC Collaboration,
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Boule,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarría,
J. R. T. de Melo Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera
, et al. (9 additional authors not shown)
Abstract:
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detect…
▽ More
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detector, DAMIC100, currently being installed at SNOLAB. This contribution discusses the installation progress, new calibration efforts near the threshold, a preliminary result with 2014 data, and the prospects for physics results after one year of data taking.
△ Less
Submitted 8 December, 2015; v1 submitted 30 September, 2015;
originally announced October 2015.
-
Current Status and Future Prospects of the SNO+ Experiment
Authors:
SNO+ Collaboration,
:,
S. Andringa,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
D. Braid,
E. Caden,
E. Callaghan,
J. Caravaca,
J. Carvalho,
L. Cavalli,
D. Chauhan,
M. Chen,
O. Chkvorets,
K. Clark
, et al. (133 additional authors not shown)
Abstract:
SNO+ is a large liquid scintillator-based experiment located 2km underground at SNOLAB, Sudbury, Canada. It reuses the Sudbury Neutrino Observatory detector, consisting of a 12m diameter acrylic vessel which will be filled with about 780 tonnes of ultra-pure liquid scintillator. Designed as a multipurpose neutrino experiment, the primary goal of SNO+ is a search for the neutrinoless double-beta de…
▽ More
SNO+ is a large liquid scintillator-based experiment located 2km underground at SNOLAB, Sudbury, Canada. It reuses the Sudbury Neutrino Observatory detector, consisting of a 12m diameter acrylic vessel which will be filled with about 780 tonnes of ultra-pure liquid scintillator. Designed as a multipurpose neutrino experiment, the primary goal of SNO+ is a search for the neutrinoless double-beta decay (0$νββ$) of 130Te. In Phase I, the detector will be loaded with 0.3% natural tellurium, corresponding to nearly 800 kg of 130Te, with an expected effective Majorana neutrino mass sensitivity in the region of 55-133 meV, just above the inverted mass hierarchy. Recently, the possibility of deploying up to ten times more natural tellurium has been investigated, which would enable SNO+ to achieve sensitivity deep into the parameter space for the inverted neutrino mass hierarchy in the future. Additionally, SNO+ aims to measure reactor antineutrino oscillations, low-energy solar neutrinos, and geoneutrinos, to be sensitive to supernova neutrinos, and to search for exotic physics. A first phase with the detector filled with water will begin soon, with the scintillator phase expected to start after a few months of water data taking. The 0$νββ$ Phase I is foreseen for 2017.
△ Less
Submitted 28 January, 2016; v1 submitted 24 August, 2015;
originally announced August 2015.
-
Measurement of radioactive contamination in the high-resistivity silicon CCDs of the DAMIC experiment
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Bole,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarria,
J. R. T. de Mello Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera,
Y. Sarkis
, et al. (8 additional authors not shown)
Abstract:
We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $α$ and $β$ particles. Uranium and thorium contamination in the CCD bulk was measured through $α$ spectroscopy, wit…
▽ More
We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $α$ and $β$ particles. Uranium and thorium contamination in the CCD bulk was measured through $α$ spectroscopy, with an upper limit on the $^{238}$U ($^{232}$Th) decay rate of 5 (15) kg$^{-1}$ d$^{-1}$ at 95% CL. We also searched for pairs of spatially correlated electron tracks separated in time by up to tens of days, as expected from $^{32}$Si-$^{32}$P or $^{210}$Pb-$^{210}$Bi sequences of $β$ decays. The decay rate of $^{32}$Si was found to be $80^{+110}_{-65}$ kg$^{-1}$ d$^{-1}$ (95% CI). An upper limit of $\sim$35 kg$^{-1}$ d$^{-1}$ (95% CL) on the $^{210}$Pb decay rate was obtained independently by $α$ spectroscopy and the $β$ decay sequence search. These levels of radioactive contamination are sufficiently low for the successful operation of CCDs in the forthcoming 100 g DAMIC detector.
△ Less
Submitted 9 July, 2015; v1 submitted 8 June, 2015;
originally announced June 2015.
-
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
S. Daley,
M. Das,
F. Debris,
N. Dhungana,
J. Farine,
I. Felis,
R. Filgas,
M. Fines-Neuschild,
F. Girard,
G. Giroux
, et al. (32 additional authors not shown)
Abstract:
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation o…
▽ More
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. These data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.
△ Less
Submitted 29 June, 2015; v1 submitted 27 February, 2015;
originally announced March 2015.
-
DEAP-3600 Dark Matter Search
Authors:
DEAP Collaboration,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
J. Bonatt,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
M. Chen,
R. Chouinard,
B. T. Cleveland,
K. Dering,
J. DiGioseffo,
F. Duncan,
T. Flower,
R. Ford,
P. Giampa,
P. Gorel,
K. Graham,
D. R. Grant,
E. Guliyev,
A. L. Hallin,
M. Hamstra
, et al. (32 additional authors not shown)
Abstract:
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $β$/$γ$ backgrounds…
▽ More
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $β$/$γ$ backgrounds and helped to develop low radioactivity techniques to mitigate surface-related $α$ backgrounds. Construction of the DEAP-3600 detector is nearly complete and commissioning is starting in 2014. The target sensitivity to spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons of 10$^{-46}$ cm$^2$ will allow one order of magnitude improvement in sensitivity over current searches at 100 GeV WIMP mass. This paper presents an overview and status of the DEAP-3600 project and discusses plans for a future multi-tonne experiment, DEAP-50T.
△ Less
Submitted 25 August, 2015; v1 submitted 27 October, 2014;
originally announced October 2014.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Update on the MiniCLEAN Dark Matter Experiment
Authors:
K. Rielage,
M. Akashi-Ronquest,
M. Bodmer,
R. Bourque,
B. Buck,
A. Butcher,
T. Caldwell,
Y. Chen,
K. Coakley,
E. Flores,
J. A. Formaggio,
D. Gastler,
F. Giuliani,
M. Gold,
E. Grace,
J. Griego,
N. Guerrero,
V. Guiseppe,
R. Henning,
A. Hime,
S. Jaditz,
C. Kachulis,
E. Kearns,
J. Kelsey,
J. R. Klein
, et al. (21 additional authors not shown)
Abstract:
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o…
▽ More
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
DAMIC: a novel dark matter experiment
Authors:
The DAMIC Collaboration,
Alexis A. Aguilar-Arevalo,
Xavier Bertou,
Melissa J. Butner,
Gustavo Cancelo,
Alvaro Chavarria,
Juan Carlos D'Olivo,
Juan Cruz Estrada Vigil,
Guillermo Fernandez Moroni,
Federico Izraelevitch,
Ben Kilminster,
Ian T. Lawson,
Fernando Marsal,
Jorge Molina,
Paolo Privitera,
Tom Schwarz,
Miguel Sofo Haro,
Javier Tiffenberg,
Frederic Trillaud,
**g Zhou
Abstract:
DAMIC (Dark Matter in CCDs) is a novel dark matter experiment that has unique sensitivity to dark matter particles with masses below 10 GeV. Due to its low electronic readout noise (R.M.S. ~3 e-) this instrument is able to reach a detection threshold below 0.5 keV nuclear recoil energy, making the search for dark matter particles with low masses possible. We report on early results and experience…
▽ More
DAMIC (Dark Matter in CCDs) is a novel dark matter experiment that has unique sensitivity to dark matter particles with masses below 10 GeV. Due to its low electronic readout noise (R.M.S. ~3 e-) this instrument is able to reach a detection threshold below 0.5 keV nuclear recoil energy, making the search for dark matter particles with low masses possible. We report on early results and experience gained from a detector that has been running at SNOLAB from Dec 2012. We also discuss the measured and expected backgrounds and present the plan for future detectors to be installed in 2014.
△ Less
Submitted 24 October, 2013;
originally announced October 2013.
-
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Authors:
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
K. Boudjemline,
M. G. Boulay B. Cai T. Caldwell,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Contreras,
K. Dering,
F. Duncan,
R. Ford,
R. Gagnon F. Giuliani,
M. Gold V. V. Golovko,
P. Gorel,
K. Graham,
D. R. Grant,
R. Hakobyan,
A. L. Hallin,
P. Harvey,
C. Hearns,
C. J. Jillings,
M. Kuźniak,
I. Lawson,
O. Li
, et al. (27 additional authors not shown)
Abstract:
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction.…
▽ More
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16 and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry.
△ Less
Submitted 23 April, 2014; v1 submitted 5 November, 2012;
originally announced November 2012.
-
New Insights into Particle Detection with Superheated Liquids
Authors:
S. Archambault,
F. Aubin,
M. Auger,
M. Beleshi,
E. Behnke,
J. Behnke,
B. Beltran,
K. Clark,
X. Dai,
A. Davour,
F. Debris. J. Farine,
M. -H. Genest,
G. Giroux,
R. Gornea,
R. Faust,
H. Hinnefeld,
A. Kamaha,
C. B. Krauss,
M. Lafrenière,
M. Laurin,
I. Lawson,
C. Leroy,
C. Lévy,
L. Lessard,
I. Levine
, et al. (12 additional authors not shown)
Abstract:
We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$α$,$γ$). In particular, detectors were spiked with alpha-emitters located inside and outside the droplets. It is shown that the responses are different, depending on whether alpha particles or recoil nuclei create the signals. The energy threshold…
▽ More
We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$α$,$γ$). In particular, detectors were spiked with alpha-emitters located inside and outside the droplets. It is shown that the responses are different, depending on whether alpha particles or recoil nuclei create the signals. The energy thresholds for $α$-emitters are compared with test beam measurements using mono-energetic neutrons, as well as with theoretical predictions. Finally a model is presented which describes how the observed intensities of particle induced acoustic signals can be related to the dynamics of bubble growth in superheated liquids. An improved understanding of the bubble dynamics is an important first step in obtaining better discrimination between particle types interacting in detectors of this kind.
△ Less
Submitted 20 November, 2010;
originally announced November 2010.