-
Current Methods for Hyperpolarized [1-13C]pyruvate MRI Human Studies
Authors:
Peder EZ Larson,
Jenna ML Bernard,
James A Bankson,
Nikolaj Bøgh,
Robert A Bok,
Albert P. Chen,
Charles H Cunningham,
Jeremy Gordon,
Jan-Bernd Hövener,
Christoffer Laustsen,
Dirk Mayer,
Mary A McLean,
Franz Schilling,
James Slater,
Jean-Luc Vanderheyden,
Cornelius von Morze,
Daniel B Vigneron,
Duan Xu,
the HP 13C MRI Consensus Group
Abstract:
MRI with hyperpolarized (HP) 13C agents, also known as HP 13C MRI, can measure processes such as localized metabolism that is altered in numerous cancers, liver, heart, kidney diseases, and more. It has been translated into human studies during the past 10 years, with recent rapid growth in studies largely based on increasing availability of hyperpolarized agent preparation methods suitable for us…
▽ More
MRI with hyperpolarized (HP) 13C agents, also known as HP 13C MRI, can measure processes such as localized metabolism that is altered in numerous cancers, liver, heart, kidney diseases, and more. It has been translated into human studies during the past 10 years, with recent rapid growth in studies largely based on increasing availability of hyperpolarized agent preparation methods suitable for use in humans. This paper aims to capture the current successful practices for HP MRI human studies with [1-13C]pyruvate - by far the most commonly used agent, which sits at a key metabolic junction in glycolysis. The paper is divided into four major topic areas: (1) HP 13C-pyruvate preparation, (2) MRI system setup and calibrations, (3) data acquisition and image reconstruction, and (4) data analysis and quantification. In each area, we identified the key components for a successful study, summarized both published studies and current practices, and discuss evidence gaps, strengths, and limitations. This paper is the output of the HP 13C MRI Consensus Group as well as the ISMRM Hyperpolarized Media MR and Hyperpolarized Methods & Equipment study groups. It further aims to provide a comprehensive reference for future consensus building as the field continues to advance human studies with this metabolic imaging modality.
△ Less
Submitted 22 November, 2023; v1 submitted 7 September, 2023;
originally announced September 2023.
-
The detection of acute kidney injury with hyperpolarized 13C Urea and multi-exponential fitting
Authors:
James T Grist,
Christian Østergaard Mariager,
Haiyun Qi,
Per Mose Nielsen,
Christoffer Laustsen
Abstract:
Purpose: To assess the utility of Laplacian fitting to describe the differences in hyperpolarized 13C urea T2 relaxation in ischemic and healthy rodent kidneys. Theory and Methods: Six rats with unilateral renal ischemia were investigated. 13C urea T2 map** was undertaken with a radial fast spin echo method, with subsequent post-processing performed with regularised Laplacian fitting. Results: S…
▽ More
Purpose: To assess the utility of Laplacian fitting to describe the differences in hyperpolarized 13C urea T2 relaxation in ischemic and healthy rodent kidneys. Theory and Methods: Six rats with unilateral renal ischemia were investigated. 13C urea T2 map** was undertaken with a radial fast spin echo method, with subsequent post-processing performed with regularised Laplacian fitting. Results: Simulations showed that Laplacian fitting was stable down to a signal to noise ratio of 20. In vivo results showed a significant increase in the mono- and decrease in bi-exponential pools in IRI kidneys, in comparison to healthy (14+-10% vs 4+-2%, 85+-10% vs 95+-3%, p<0.05). Conclusion: We demonstrate, for the first time, the differences in multi-exponential behaviour of 13C,15N2-urea between the healthy and ischemic rodent kidney. The distribution of relaxation pools were found to be both visually and numerically significantly different. The ability to improve the information level in hyperpolarized MR, by utilizing the relaxation contrast mechanisms is an appealing option, that can easily be adopted in large animals and even in clinical studies in the near future.
△ Less
Submitted 24 October, 2019;
originally announced October 2019.
-
Superparamagnetic iron oxide polyacrylic acid coated γ-Fe2O3 nanoparticles does not affect kidney function but causes acute effect on the cardiovascular function in healthy mice
Authors:
Nina K. Iversen,
Sebastian Frische,
Karen Thomsen,
Christoffer Laustsen,
Michael Pedersen,
Pernille B. L. Hansen,
Peter Bie,
Jérome Fresnais,
Jean-Francois Berret,
Erik Baatrup,
Tobias Wang
Abstract:
This study describes the distribution of intravenously injected polyacrylic acid (PAA) coated γ-Fe2O3 NPs (10 mg kg-1) at the organ, cellular and subcellular levels in healthy BALB/cJ mice and in parallel addresses the effects of NP injection on kidney function, blood pressure and vascular contractility. Magnetic resonance imaging (MRI) and transmission electron microscopy (TEM) showed accumulatio…
▽ More
This study describes the distribution of intravenously injected polyacrylic acid (PAA) coated γ-Fe2O3 NPs (10 mg kg-1) at the organ, cellular and subcellular levels in healthy BALB/cJ mice and in parallel addresses the effects of NP injection on kidney function, blood pressure and vascular contractility. Magnetic resonance imaging (MRI) and transmission electron microscopy (TEM) showed accumulation of NPs in the liver within 1h after intravenous infusion, accommodated by intracellular uptake in endothelial and Kupffer cells with subsequent intracellular uptake in renal cells, particularly the cytoplasm of the proximal tubule, in podocytes and mesangial cells. The renofunctional effects of NPs were evaluated by arterial acid-base status and measurements of glomerular filtration rate (GFR) after instrumentation with chronically indwelling catheters. Arterial pH was 7.46 and 7.41 in mice 0.5 h after injections of saline or NP, and did not change over the next 12h. In addition, the injections of NP did not affect arterial PCO2 or [HCO3-] either. Twenty-four and 96h after NP injections, the GFR averaged 11.0 and 13.0 ml min-1 g-1, respectively, values which were statistically comparable with controls (14.0 and 14.0 ml min-1 g-1). Mean arterial blood pressure (MAP) decreased 12-24h after NP injections (111 vs 123 min-1) associated with a decreased contractility of small mesenteric arteries revealed by myography to characterise endothelial function. In conclusion, our study demonstrates that accumulation of superparamagnetic iron oxide nanoparticles does not affect kidney function in healthy mice but temporarily decreases blood pressure.
△ Less
Submitted 7 January, 2014;
originally announced January 2014.