Rapid, $B_1$-insensitive, dual-band quasi-adiabatic saturation transfer with optimal control for complete quantification of myocardial ATP flux
Authors:
Jack J. Miller,
Ladislav Valkovič,
Matthew Kerr,
Kerstin N. Timm,
William Watson,
Justin Y. C. Lau,
Andrew Tyler,
Christopher Rodgers,
Paul A. Bottomley,
Lisa C. Heather,
Damian J. Tyler
Abstract:
Purpose: Phosphorus saturation-transfer experiments can quantify metabolic fluxes non-invasively. Typically, the forward flux through the creatine-kinase reaction is investigated by observing the decrease in phosphocreatine (PCr) after saturation of $γ$-ATP. The quantification of total ATP utilisation is currently under-explored, as it requires simultaneous saturation of inorganic phosphate (Pi) a…
▽ More
Purpose: Phosphorus saturation-transfer experiments can quantify metabolic fluxes non-invasively. Typically, the forward flux through the creatine-kinase reaction is investigated by observing the decrease in phosphocreatine (PCr) after saturation of $γ$-ATP. The quantification of total ATP utilisation is currently under-explored, as it requires simultaneous saturation of inorganic phosphate (Pi) and PCr. This is challenging, as currently available saturation pulses reduce the already-low $γ$-ATP signal present.
Methods: Using a hybrid optimal-control and Shinnar-Le-Roux method, a quasi-adiabatic RF pulse was designed for the dual-saturation of PCr and Pi to enable determination of total ATP utilisation. The pulses were evaluated in Bloch equation simulations, compared with a conventional hard-cosine DANTE saturation sequence, before application to perfused rat hearts at 11.7 Tesla.
Results: The quasi-adiabatic pulse was insensitive to a $>2.5$-fold variation in $B_1$, producing equivalent saturation with a 53% reduction in delivered pulse power and a 33-fold reduction in spillover at the minimum effective $B_1$. This enabled the complete quantification of the synthesis and degradation fluxes for ATP in 30-45 minutes in the perfused rat heart. While the net synthesis flux ($4.24\pm0.8$ mM/s, SEM) was not significantly different from degradation flux ($6.88\pm2$ mM/s, $p=0.06$) and both measures are consistent with prior work, nonlinear error analysis highlights uncertainties in the Pi-to-ATP measurement that may explain a trend suggesting a possible imbalance.
Conclusion: This work demonstrates a novel quasi-adiabatic dual-saturation RF pulse with significantly improved performance that can be used to measure ATP turnover in the heart in vivo.
△ Less
Submitted 25 November, 2020; v1 submitted 10 August, 2020;
originally announced August 2020.
A 3D-Hybrid-Shot Spiral Sequence for Hyperpolarized $^{13}$C Imaging
Authors:
Andrew Tyler,
Justin Y. C. Lau,
Vicky Ball,
Kerstin N. Timm,
Tony Zhou,
Damian J. Tyler,
Jack J. Miller
Abstract:
Purpose: Hyperpolarized imaging experiments have conflicting requirements of high spatial, temporal, and spectral resolution. Spectral-Spatial RF excitation has been shown to form an attractive magnetization-efficient method for hyperpolarized imaging, but the optimum readout strategy is not yet known.
Methods: In this work we propose a novel 3D hybrid-shot spiral sequence which features two con…
▽ More
Purpose: Hyperpolarized imaging experiments have conflicting requirements of high spatial, temporal, and spectral resolution. Spectral-Spatial RF excitation has been shown to form an attractive magnetization-efficient method for hyperpolarized imaging, but the optimum readout strategy is not yet known.
Methods: In this work we propose a novel 3D hybrid-shot spiral sequence which features two constant density regions that permit the retrospective reconstruction of either high spatial or high temporal resolution images post hoc, (adaptive spatiotemporal imaging) allowing greater flexibility in acquisition and reconstruction.
Results: We have implemented this sequence, both via simulation and on a pre-clinical scanner, to demonstrate its feasibility, in both a 1H phantom and with hyperpolarized 13C pyruvate in vivo. Conclusion: This sequence forms an attractive method for acquiring hyperpolarized imaging datasets, providing adaptive spatiotemporal imaging to ameliorate the conflict of spatial and temporal resolution, with significant potential for clinical translation.
△ Less
Submitted 10 July, 2020;
originally announced July 2020.