-
A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures
Authors:
A. Erhart,
V. Wagner,
A. Wex,
C. Goupy,
D. Lhuillier,
E. Namuth,
C. Nones,
R. Rogly,
V. Savu,
M. Schwarz,
R. Strauss,
M. Vivier,
H. Abele,
G. Angloher,
A. Bento,
J. Burkhart,
L. Canonica,
F. Cappella,
N. Casali,
R. Cerulli,
A. Cruciani,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer
, et al. (37 additional authors not shown)
Abstract:
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we…
▽ More
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we developed a cryogenic muon veto equipped with wavelength shifting fibers and a silicon photo multiplier operating inside a dilution refrigerator. The achievable compactness of cryostat-internal integration is a key factor in kee** the muon rate to a minimum while maximizing coverage. The thermal and light output properties of a plastic scintillation detector were examined. We report first data on the thermal conductivity and heat capacity of the polystyrene-based scintillator UPS-923A over a wide range of temperatures extending below one Kelvin. The light output was measured down to 0.8K and observed to increase by a factor of 1.61$\pm$0.05 compared to 300K. The development of an organic plastic scintillation muon veto operating in sub-Kelvin temperature environments opens new perspectives for rare-event searches with cryogenic detectors at sites lacking substantial overburden.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
Study of collision and $γ$-cascade times following neutron-capture processes in cryogenic detectors
Authors:
CRAB collaboration,
G. Soum-Sidikov,
H. Abele,
J. Burkhart,
F. Cappella,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
J-P. Crocombette,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
E. Dumonteil,
A. Erhart,
A. Giuliani,
C. Goupy,
F. Gunsing,
E. Jericha,
M. Kaznacheeva,
A. Kinast,
H. Kluck,
A. Langenkämper,
T. Lasserre
, et al. (25 additional authors not shown)
Abstract:
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay betwe…
▽ More
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay between the development in time of the de-excitation $γ$-cascade of the target nucleus and that of the associated atomic collisions in matter. We present detailed simulations coupling the FIFRELIN code for the description of the $γ$-cascades and the IRADINA code for the modelling of the fast atomic movements in matter. Nuclear recoil spectra are predicted, and made available to the community, for concrete cases of Al$_2$O$_3$, Si, Ge and CaWO$_4$ crystals exposed to a low intensity beam of thermal neutrons. We find that timing effects cause new calibration peaks to emerge in the recoil spectra and also impact the shape of the continuous recoil distribution. We discuss how they could give access to a rich physics program, spanning the accurate study of the response of cryogenic detectors in the sub-keV range, tests of solid state physics simulations and tests of nuclear models.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Exploring coherent elastic neutrino-nucleus scattering of reactor neutrinos with the NUCLEUS experiment
Authors:
The NUCLEUS collaboration,
C. Goupy,
H. Abele,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
I. Colantoni,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
A. Erhart,
M. Friendl,
A. Garai,
V. M. Ghete,
D. Hauff,
F. Jeanneau,
E. Jericha,
M. Kaznacheeva,
A. Kinast
, et al. (37 additional authors not shown)
Abstract:
The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS is a unique process to study neutrino properties and to search for physics beyond the Standard Model. The study of CEvNS is also important for light Dark-Matter searches. It could be a possible irreducible background for…
▽ More
The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS is a unique process to study neutrino properties and to search for physics beyond the Standard Model. The study of CEvNS is also important for light Dark-Matter searches. It could be a possible irreducible background for high-sensitivity Dark-Matter searches. NUCLEUS is an experiment under construction based on ultra-low threshold (20 eVnr) cryogenic calorimeters, operated at tens-of-mK temperatures.
△ Less
Submitted 10 November, 2022; v1 submitted 8 November, 2022;
originally announced November 2022.
-
Observation of a nuclear recoil peak at the 100 eV scale induced by neutron capture
Authors:
CRAB Collaboration,
NUCLEUS Collaboration,
H. Abele,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
I. Colantoni,
J. -P. Crocombette,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
D. Desforge,
A. Doblhammer,
E. Dumonteil,
S. Dorer,
A. Erhart,
A. Fuss,
M. Friedl,
A. Garai
, et al. (53 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact…
▽ More
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact moderator. The measured spectrum is found in agreement with simulations and the expected peak structure from the single-$γ$ de-excitation of $^{183}$W is identified with 3 $σ$ significance. This result demonstrates a new method for precise, in-situ, and non-intrusive calibration of low-threshold experiments.
△ Less
Submitted 2 June, 2023; v1 submitted 7 November, 2022;
originally announced November 2022.
-
Development of an Organic Plastic Scintillator based Muon Veto Operating at Sub-Kelvin Temperatures for the NUCLEUS Experiment
Authors:
Andreas Erhart,
Victoria Wagner,
Ludwig Klinkenberg,
Thierry Lasserre,
David Lhuillier,
Claudia Nones,
Rudolph Rogly,
Vladimir Savu,
Matthieu Vivier
Abstract:
The NUCLEUS experiment aims at measuring the coherent elastic scattering of nuclear reactor antineutrinos off nuclei using cryogenic calorimeters. Operating at an overburden of 3m.w.e., muon-induced backgrounds are expected to be dominant. It is therefore essential to develop an efficient muon veto, with a detection efficiency of more than 99%. This will be realized in NUCLEUS through a compact cu…
▽ More
The NUCLEUS experiment aims at measuring the coherent elastic scattering of nuclear reactor antineutrinos off nuclei using cryogenic calorimeters. Operating at an overburden of 3m.w.e., muon-induced backgrounds are expected to be dominant. It is therefore essential to develop an efficient muon veto, with a detection efficiency of more than 99%. This will be realized in NUCLEUS through a compact cube assembly of plastic scintillator panels. In order to prevent a large unshielded area where the cryostat intersects the shielding arrangement without unnecessarily increasing the induced detector dead time, a novel concept has been investigated, featuring a plastic scintillator based active muon veto operating inside the NUCLEUS cryostat at sub-Kelvin temperatures. The verification of the key physical aspects of this cryogenic muon veto detector led to the first reported measurements of organic plastic scintillators at sub-Kelvin temperatures. The functionality of the principal scintillation process of organic plastic scintillators at these temperatures has been confirmed. On the basis of these findings, a disc-shape plastic scintillator equipped with wavelength shifting fibers and a silicon photomultiplier to guide and detect the scintillation light has been developed. The NUCLEUS cryogenic muon veto will be the first of its kind to be operated at sub-Kelvin temperatures.
△ Less
Submitted 3 May, 2022;
originally announced May 2022.
-
KATRIN: Status and Prospects for the Neutrino Mass and Beyond
Authors:
M. Aker,
M. Balzer,
D. Batzler,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
M. Biassoni,
B. Bieringer,
F. Block,
S. Bobien,
L. Bombelli,
D. Bormann,
B. Bornschein,
L. Bornschein,
M. Böttcher,
C. Brofferio,
C. Bruch,
T. Brunst,
T. S. Caldwell,
M. Carminati,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
O. Cremonesi
, et al. (137 additional authors not shown)
Abstract:
The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a su…
▽ More
The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a sub-eV sensitivity. After 1000 days of data-taking, KATRIN's design sensitivity is 0.2 eV at the 90% confidence level. In this white paper we describe the current status of KATRIN; explore prospects for measuring the neutrino mass and other physics observables, including sterile neutrinos and other beyond-Standard-Model hypotheses; and discuss research-and-development projects that may further improve the KATRIN sensitivity.
△ Less
Submitted 16 June, 2023; v1 submitted 15 March, 2022;
originally announced March 2022.
-
White Paper on Light Sterile Neutrino Searches and Related Phenomenology
Authors:
M. A. Acero,
C. A. Argüelles,
M. Hostert,
D. Kalra,
G. Karagiorgi,
K. J. Kelly,
B. Littlejohn,
P. Machado,
W. Pettus,
M. Toups,
M. Ross-Lonergan,
A. Sousa,
P. T. Surukuchi,
Y. Y. Y. Wong,
W. Abdallah,
A. M. Abdullahi,
R. Akutsu,
L. Alvarez-Ruso,
D. S. M. Alves,
A. Aurisano,
A. B. Balantekin,
J. M. Berryman,
T. Bertólez-Martínez,
J. Brunner,
M. Blennow
, et al. (147 additional authors not shown)
Abstract:
This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference,…
▽ More
This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference, with emphasis on needs and options for future exploration that may lead to the ultimate resolution of the anomalies. We see the main experimental, analysis, and theory-driven thrusts that will be essential to achieving this goal being: 1) Cover all anomaly sectors -- given the unresolved nature of all four canonical anomalies, it is imperative to support all pillars of a diverse experimental portfolio, source, reactor, decay-at-rest, decay-in-flight, and other methods/sources, to provide complementary probes of and increased precision for new physics explanations; 2) Pursue diverse signatures -- it is imperative that experiments make design and analysis choices that maximize sensitivity to as broad an array of these potential new physics signatures as possible; 3) Deepen theoretical engagement -- priority in the theory community should be placed on development of standard and beyond standard models relevant to all four short-baseline anomalies and the development of tools for efficient tests of these models with existing and future experimental datasets; 4) Openly share data -- Fluid communication between the experimental and theory communities will be required, which implies that both experimental data releases and theoretical calculations should be publicly available; and 5) Apply robust analysis techniques -- Appropriate statistical treatment is crucial to assess the compatibility of data sets within the context of any given model.
△ Less
Submitted 17 May, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Development of a compact muon veto for the NUCLEUS experiment
Authors:
V. Wagner,
R. Rogly,
A. Erhart,
V. Savu,
C. Goupy,
D. Lhuillier,
M. Vivier,
L. Klinkenberg,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
I. Colantoni,
A. Cruciani,
G. del Castello,
M. Friedl,
A. Garai,
V. M. Ghete,
V. Guidi,
D. Hauff,
M. Kaznacheeva,
A. Kinast
, et al. (30 additional authors not shown)
Abstract:
The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e., muon-induced backgrounds are expected to be one of the dominant background contributions. Besides a high efficiency to identify muon events passing the experimental setup, the NUCLEUS muon veto has to fulfill tight spati…
▽ More
The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e., muon-induced backgrounds are expected to be one of the dominant background contributions. Besides a high efficiency to identify muon events passing the experimental setup, the NUCLEUS muon veto has to fulfill tight spatial requirements to fit the constraints given by the experimental site and to minimize the induced detector dead-time. We developed highly efficient and compact muon veto modules based on plastic scintillators equipped with wavelength shifting fibers and silicon photo multipliers to collect and detect the scintillation light. In this paper, we present the full characterization of a prototype module with different light read-out configurations. We conclude that an efficient and compact muon veto system can be built for the NUCLEUS experiment from a cube assembly of the developed modules. Simulations show that an efficiency for muon identification of >99 % and an associated rate of 325 Hz is achievable, matching the requirements of the NUCLEUS experiment.
△ Less
Submitted 26 April, 2022; v1 submitted 8 February, 2022;
originally announced February 2022.
-
The Double Chooz antineutrino detectors
Authors:
Double Chooz Collaboration,
H. de Kerret,
Y. Abe,
C. Aberle,
T. Abrahão,
J. M. Ahijado,
T. Akiri,
J. M. Alarcón,
J. Alba,
H. Almazan,
J. C. dos Anjos,
S. Appel,
F. Ardellier,
I. Barabanov,
J. C. Barriere,
E. Baussan,
A. Baxter,
I. Bekman,
M. Bergevin,
A. Bernstein,
W. Bertoli,
T. J. C. Bezerra,
L. Bezrukov,
C. Blanco,
N. Bleurvacq
, et al. (226 additional authors not shown)
Abstract:
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in th…
▽ More
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.
△ Less
Submitted 13 September, 2022; v1 submitted 31 January, 2022;
originally announced January 2022.
-
Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment
Authors:
M. Aker,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards,
K. Eitel,
E. Ellinger
, et al. (110 additional authors not shown)
Abstract:
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectromet…
▽ More
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6$\,$keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $β$-electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the \linebreak energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique.
We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% T$_2$ gas mixture at 30$\,$K, as used in the first KATRIN neutrino mass analyses, as well as a D$_2$ gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $σ(m_ν^2)<10^{-2}\,\mathrm{eV}^2$ [arXiv:2101.05253] in the KATRIN neutrino-mass measurement to a subdominant level.
△ Less
Submitted 14 May, 2021;
originally announced May 2021.
-
The Design, Construction, and Commissioning of the KATRIN Experiment
Authors:
M. Aker,
K. Altenmüller,
J. F. Amsbaugh,
M. Arenz,
M. Babutzka,
J. Bast,
S. Bauer,
H. Bechtler,
M. Beck,
A. Beglarian,
J. Behrens,
B. Bender,
R. Berendes,
A. Berlev,
U. Besserer,
C. Bettin,
B. Bieringer,
K. Blaum,
F. Block,
S. Bobien,
J. Bohn,
K. Bokeloh,
H. Bolz,
B. Bornschein,
L. Bornschein
, et al. (204 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goa…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [arXiv:1909.06048]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns.
△ Less
Submitted 11 June, 2021; v1 submitted 5 March, 2021;
originally announced March 2021.
-
Analysis methods for the first KATRIN neutrino-mass measurement
Authors:
M. Aker,
K. Altenmüller,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
K. Blaum,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
D. Díaz Barrero,
K. Debowski,
M. Deffert,
M. Descher,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (104 additional authors not shown)
Abstract:
We report on the data set, data handling, and detailed analysis techniques of the first neutrino-mass measurement by the Karlsruhe Tritium Neutrino (KATRIN) experiment, which probes the absolute neutrino-mass scale via the $β$-decay kinematics of molecular tritium. The source is highly pure, cryogenic T$_2$ gas. The $β$ electrons are guided along magnetic field lines toward a high-resolution, inte…
▽ More
We report on the data set, data handling, and detailed analysis techniques of the first neutrino-mass measurement by the Karlsruhe Tritium Neutrino (KATRIN) experiment, which probes the absolute neutrino-mass scale via the $β$-decay kinematics of molecular tritium. The source is highly pure, cryogenic T$_2$ gas. The $β$ electrons are guided along magnetic field lines toward a high-resolution, integrating spectrometer for energy analysis. A silicon detector counts $β$ electrons above the energy threshold of the spectrometer, so that a scan of the thresholds produces a precise measurement of the high-energy spectral tail. After detailed theoretical studies, simulations, and commissioning measurements, extending from the molecular final-state distribution to inelastic scattering in the source to subtleties of the electromagnetic fields, our independent, blind analyses allow us to set an upper limit of 1.1 eV on the neutrino-mass scale at a 90\% confidence level. This first result, based on a few weeks of running at a reduced source intensity and dominated by statistical uncertainty, improves on prior limits by nearly a factor of two. This result establishes an analysis framework for future KATRIN measurements, and provides important input to both particle theory and cosmology.
△ Less
Submitted 12 May, 2021; v1 submitted 13 January, 2021;
originally announced January 2021.
-
Calibration of nuclear recoils at the 100 eV scale using neutron capture
Authors:
L. Thulliez,
D. Lhuillier,
F. Cappella,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
E. Dumonteil,
A. Erhart,
A. Giuliani,
F. Gunsing,
E. Jericha,
M. Kaznacheeva,
A. Kinast,
A. Langenkämper,
T. Lasserre,
A. Letourneau,
O. Litaize,
P. de Marcillac,
S. Marnieros,
T. Materna,
B. Mauri,
E. Mazzucato,
C. Nones,
T. Ortmann
, et al. (12 additional authors not shown)
Abstract:
The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear recoils resulting from the $γ$ emission following thermal neutron capture. In particular, several MeV-scale single-$γ$ transitions induce well-defined nuclear…
▽ More
The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear recoils resulting from the $γ$ emission following thermal neutron capture. In particular, several MeV-scale single-$γ$ transitions induce well-defined nuclear recoil peaks in the 100 eV range. Using the FIFRELIN code, complete schemes of $γ$-cascades for various isotopes can be predicted with high accuracy to determine the continuous background of nuclear recoils below the calibration peaks. We present a comprehensive experimental concept for the calibration of CaWO$_4$ and Ge cryogenic detectors at a research reactor. For CaWO$_4$ the simulations show that two nuclear recoil peaks at 112.5 eV and 160.3 eV should be visible above background simply in the spectrum of the cryogenic detector. Then we discuss how the additional tagging for the associated $γ$ increases the sensitivity of the method and extends its application to a wider energy range and to Ge cryogenic detectors.
△ Less
Submitted 23 May, 2021; v1 submitted 27 November, 2020;
originally announced November 2020.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
Search for Signatures of Sterile Neutrinos with Double Chooz
Authors:
The Double Chooz Collaboration,
T. Abrahão,
H. Almazan,
J. C. dos Anjos,
S. Appel,
J. C. Barriere,
I. Bekman,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
M. Cerrada,
E. Chauveau,
P. Chimenti,
O. Corpace,
J. V. Dawson,
Z. Djurcic,
A. Etenko,
H. Furuta,
I. Gil-Botella,
A. Givaudan,
H. Gomez
, et al. (70 additional authors not shown)
Abstract:
We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e.\ comparing the data to the model prediction of disappe…
▽ More
We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e.\ comparing the data to the model prediction of disappearance in a data-to-data comparison of the two respective detectors. The analysis is optimized for a model of three active and one sterile neutrino. It is sensitive in the typical mass range $5 \cdot 10^{-3} $ eV$^2 \lesssim Δm^2_{41} \lesssim 3\cdot 10^{-1} $ eV$^2$ for mixing angles down to $\sin^2 2θ_{14} \gtrsim 0.02$. No significant disappearance additionally to the conventional disappearance related to $θ_{13} $ is observed and correspondingly exclusion bounds on the sterile mixing parameter $θ_{14} $ as function of $ Δm^2_{41} $ are obtained.
△ Less
Submitted 19 July, 2021; v1 submitted 11 September, 2020;
originally announced September 2020.
-
Reactor Rate Modulation oscillation analysis with two detectors in Double Chooz
Authors:
Double Chooz Collaboration,
T. Abrahão,
H. Almazan,
J. C. dos Anjos,
S. Appel,
I. Bekman,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
M. Cerrada,
E. Chauveau,
P. Chimenti,
J. V. Dawson,
Z. Djurcic,
A. Etenko,
H. Furuta,
I. Gil-Botella,
L. F. G. Gonzalez,
M. C. Goodman,
T. Hara,
D. Hellwig
, et al. (62 additional authors not shown)
Abstract:
A $θ_{13}$ oscillation analysis based on the observed antineutrino rates at the Double Chooz far and near detectors for different reactor power conditions is presented. This approach provides a so far unique simultaneous determination of $θ_{13}$ and the total background rates without relying on any assumptions on the specific background contributions. The analysis comprises 865 days of data colle…
▽ More
A $θ_{13}$ oscillation analysis based on the observed antineutrino rates at the Double Chooz far and near detectors for different reactor power conditions is presented. This approach provides a so far unique simultaneous determination of $θ_{13}$ and the total background rates without relying on any assumptions on the specific background contributions. The analysis comprises 865 days of data collected in both detectors with at least one reactor in operation. The oscillation results are enhanced by the use of 24.06 days (12.74 days) of reactor-off data in the far (near) detector. The analysis considers the \nue interactions up to a visible energy of 8.5 MeV, using the events at higher energies to build a cosmogenic background model considering fast-neutrons interactions and $^{9}$Li decays. The background-model-independent determination of the mixing angle yields sin$^2(2θ_{13})=0.094\pm0.017$, being the best-fit total background rates fully consistent with the cosmogenic background model. A second oscillation analysis is also performed constraining the total background rates to the cosmogenic background estimates. While the central value is not significantly modified due to the consistency between the reactor-off data and the background estimates, the addition of the background model reduces the uncertainty on $θ_{13}$ to 0.015. Along with the oscillation results, the normalization of the anti-neutrino rate is measured with a precision of 0.86\%, reducing the 1.43\% uncertainty associated to the expectation.
△ Less
Submitted 3 December, 2020; v1 submitted 27 July, 2020;
originally announced July 2020.
-
MADMAX Status Report
Authors:
S. Beurthey,
N. Böhmer,
P. Brun,
A. Caldwell,
L. Chevalier,
C. Diaconu,
G. Dvali,
P. Freire,
E. Garutti,
C. Gooch,
A. Hambarzumjan,
S. Heyminck,
F. Hubaut,
J. Jochum,
P. Karst,
S. Khan,
D. Kittlinger,
S. Knirck,
M. Kramer,
C. Krieger,
T. Lasserre,
C. Lee,
X. Li,
A. Lindner,
B. Majorovits
, et al. (20 additional authors not shown)
Abstract:
In this report we present the status of the MAgnetized Disk and Mirror Axion eXperiment (MADMAX), the first dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. MADMAX will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable em…
▽ More
In this report we present the status of the MAgnetized Disk and Mirror Axion eXperiment (MADMAX), the first dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. MADMAX will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable emission of axion induced electromagnetic waves at a frequency between 10 and 100 GHz corresponding to the axion mass. The present document orignated from a status report to the DESY PRC in 2019.
△ Less
Submitted 28 October, 2020; v1 submitted 24 March, 2020;
originally announced March 2020.
-
Suppression of Penning discharges between the KATRIN spectrometers
Authors:
M. Aker,
K. Altenmüller,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
K. Eitel
, et al. (129 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space b…
▽ More
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, "electron catchers" were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.
△ Less
Submitted 17 September, 2020; v1 submitted 21 November, 2019;
originally announced November 2019.
-
First operation of the KATRIN experiment with tritium
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
W. -J. Baek,
J. Barrett,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun
, et al. (146 additional authors not shown)
Abstract:
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.…
▽ More
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.2 eV 90% CL. In this work we report on the first operation of KATRIN with tritium which took place in 2018. During this commissioning phase of the tritium circulation system, excellent agreement of the theoretical prediction with the recorded spectra was found and stable conditions over a time period of 13 days could be established. These results are an essential prerequisite for the subsequent neutrino mass measurements with KATRIN in 2019.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
M. Babutzka,
J. Barrett,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
K. Bokeloh,
J. Bonn,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
T. J. Corona
, et al. (184 additional authors not shown)
Abstract:
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an…
▽ More
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an effective neutrino mass square value of $(-1.0^{+0.9}_{-1.1})$ eV$^2$. From this we derive an upper limit of 1.1 eV (90$\%$ confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of two and provides model-independent input to cosmological studies of structure formation.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
Measurements with a TRISTAN prototype detector system at the "Troitsk nu-mass" experiment in integral and differential mode
Authors:
Tim Brunst,
Thibaut Houdy,
Susanne Mertens,
Aleksander Nozik,
Vladislav Pantuev,
Djohnrid Abdurashitov,
Konrad Altenmüller,
Alexander Belesev,
Luca Bombelli,
Vasiliy Chernov,
Evgeniy Geraskin,
Anton Huber,
Nikolay Ionov,
Gregory Koroteev,
Marc Korzeczek,
Thierry Lasserre,
Peter Lechner,
Nikolay Likhovid,
Alexey Lokhov,
Vladimir Parfenov,
Daniel Siegmann,
Aino Skasyrskaya,
Martin Slezák,
Igor Tkachev,
Sergey Zadorozhny
Abstract:
Sterile neutrinos emerge in minimal extensions of the Standard Model which can solve a number of open questions in astroparticle physics. For example, sterile neutrinos in the keV-mass range are viable dark matter candidates. Their existence would lead to a kink-like distortion in the tritium $β$-decay spectrum. In this work we report about the instrumentation of the Troitsk nu-mass experiment wit…
▽ More
Sterile neutrinos emerge in minimal extensions of the Standard Model which can solve a number of open questions in astroparticle physics. For example, sterile neutrinos in the keV-mass range are viable dark matter candidates. Their existence would lead to a kink-like distortion in the tritium $β$-decay spectrum. In this work we report about the instrumentation of the Troitsk nu-mass experiment with a 7-pixel TRISTAN prototype detector and measurements in both differential and integral mode. The combination of the two modes is a key requirement for a precise sterile neutrino search, as both methods are prone to largely different systematic uncertainties. Thanks to the excellent performance of the TRISTAN detector at high rates, a sterile neutrino search up to masses of about 6 keV could be performed, which enlarges the previous accessible mass range by a factor of 3. Upper limits on the neutrino mixing amplitude in the mass range < 5.6 keV (differential) and < 6.6 keV (integral) are presented. These results demonstrate the feasibility of a sterile neutrino search as planned in the upgrade of the KATRIN experiment with the final TRISTAN detector and read-out system.
△ Less
Submitted 18 October, 2019; v1 submitted 6 September, 2019;
originally announced September 2019.
-
Comprehensive geoneutrino analysis with Borexino
Authors:
M. Agostini,
K. Altenmüller,
S. Appel,
V. Atroshchenko,
Z. Bagdasarian,
D. Basilico,
G. Bellini,
J. Benziger,
D. Bick,
G. Bonfini,
D. Bravo,
B. Caccianiga,
F. Calaprice,
A. Caminata,
L. Cappelli,
P. Cavalcante,
F. Cavanna,
A. Chepurnov,
K. Choi,
D. D'Angelo,
S. Davini,
A. Derbin,
A. Di Giacinto,
V. Di Marcello,
X. F. Ding
, et al. (87 additional authors not shown)
Abstract:
This paper presents a geoneutrino measurement using 3262.74 days of data taken with the Borexino detector at LNGS in Italy. By observing $52.6 ^{+9.4}_{-8.6} ({\rm stat}) ^{+2.7}_{-2.1}({\rm sys})$ geoneutrinos (68% interval) from $^{238}$U and $^{232}$Th, a signal of $47.0^{+8.4}_{-7.7}\,({\rm stat)}^{+2.4}_{-1.9}\,({\rm sys})$ TNU with $^{+18.3}_{-17.2}$% total precision was obtained. This resul…
▽ More
This paper presents a geoneutrino measurement using 3262.74 days of data taken with the Borexino detector at LNGS in Italy. By observing $52.6 ^{+9.4}_{-8.6} ({\rm stat}) ^{+2.7}_{-2.1}({\rm sys})$ geoneutrinos (68% interval) from $^{238}$U and $^{232}$Th, a signal of $47.0^{+8.4}_{-7.7}\,({\rm stat)}^{+2.4}_{-1.9}\,({\rm sys})$ TNU with $^{+18.3}_{-17.2}$% total precision was obtained. This result assumes the same Th/U mass ratio found in chondritic CI meteorites but compatible results were found when contributions from $^{238}$U and $^{232}$Th were fit as free parameters. Antineutrino background from reactors is fit unconstrained and found compatible with the expectations. The null-hypothesis of observing a signal from the mantle is excluded at a 99.0% C.L. when exploiting the knowledge of the local crust. Measured mantle signal of $21.2 ^{+9.6}_{-9.0} ({\rm stat})^{+1.1}_{-0.9} ({\rm sys})$ TNU corresponds to the production of a radiogenic heat of $24.6 ^{+11.1}_{-10.4}$ TW (68% interval) from $^{238}$U and $^{232}$Th in the mantle. Assuming 18% contribution of $^{40}$K in the mantle and $8.1^{+1.9}_{-1.4}$ TW of radiogenic heat of the lithosphere, the Borexino estimate of the total Earth radiogenic heat is $38.2 ^{+13.6}_{-12.7}$ TW, corresponding to a convective Urey ratio of 0.78$^{+0.41}_{-0.28}$. These values are compatible with different geological models, however there is a 2.4$σ$ tension with those which predict the lowest concentration of heat-producing elements. By fitting the data with a constraint on the reactor antineutrino background, the existence of a hypothetical georeactor at the center of the Earth having power greater than 2.4 TW at 95% C.L. is excluded. Particular attention is given to all analysis details, which should be of interest for the next generation geoneutrino measurements.
△ Less
Submitted 14 February, 2020; v1 submitted 5 September, 2019;
originally announced September 2019.
-
Exploring CEvNS with NUCLEUS at the Chooz Nuclear Power Plant
Authors:
G. Angloher,
F. Ardellier-Desages,
A. Bento,
L. Canonica,
A. Erhart,
N. Ferreiro,
M. Friedl,
V. M. Ghete,
D. Hauff,
H. Kluck,
A. Langenkämper,
T. Lasserre,
D. Lhuillier,
A. Kinast,
M. Mancuso,
J. Molina Rubiales,
E. Mondragon,
G. Munch,
C. Nones,
L. Oberauer,
A. Onillon,
T. Ortmann,
L. Pattavina,
F. Petricca,
W. Potzel
, et al. (12 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers a unique way to study neutrino properties and to search for new physics beyond the Standard Model. Nuclear reactors are promising sources to explore this process at low energies since they deliver large fluxes of (anti-)neutrinos with typical energies of a few MeV. In this paper, a new-generation experiment to study CE$ν$NS is described…
▽ More
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers a unique way to study neutrino properties and to search for new physics beyond the Standard Model. Nuclear reactors are promising sources to explore this process at low energies since they deliver large fluxes of (anti-)neutrinos with typical energies of a few MeV. In this paper, a new-generation experiment to study CE$ν$NS is described. The NUCLEUS experiment will use cryogenic detectors which feature an unprecedentedly low energy threshold and a time response fast enough to be operated in above-ground conditions. Both sensitivity to low-energy nuclear recoils and a high event rate tolerance are stringent requirements to measure CE$ν$NS of reactor antineutrinos. A new experimental site, denoted the Very-Near-Site (VNS) at the Chooz nuclear power plant in France is described. The VNS is located between the two 4.25 GW$_{\mathrm{th}}$ reactor cores and matches the requirements of NUCLEUS. First results of on-site measurements of neutron and muon backgrounds, the expected dominant background contributions, are given. In this paper a preliminary experimental setup with dedicated active and passive background reduction techniques is presented. Furthermore, the feasibility to operate the NUCLEUS detectors in coincidence with an active muon-veto at shallow overburden is studied. The paper concludes with a sensitivity study pointing out the promising physics potential of NUCLEUS at the Chooz nuclear power plant.
△ Less
Submitted 24 May, 2019;
originally announced May 2019.
-
High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards
, et al. (102 additional authors not shown)
Abstract:
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstr…
▽ More
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.
△ Less
Submitted 18 March, 2019; v1 submitted 15 March, 2019;
originally announced March 2019.
-
Gamma-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
K. Eitel
, et al. (101 additional authors not shown)
Abstract:
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test th…
▽ More
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test the hypothesis that gamma radiation from external radioactive sources significantly increases the rate of background events created in the main spectrometer (MS) and observed in the focal-plane detector. Using detailed simulations of the gamma flux in the experimental hall, combined with a series of experimental tests that artificially increased or decreased the local gamma flux to the MS, we set an upper limit of 0.006 count/s (90% C.L.) from this mechanism. Our results indicate the effectiveness of the electrostatic and magnetic shielding used to block secondary electrons emitted from the inner surface of the MS.
△ Less
Submitted 10 July, 2019; v1 submitted 1 March, 2019;
originally announced March 2019.
-
A new experimental approach to probe QCD axion dark matter in the mass range above 40$μ$eV
Authors:
The MADMAX Collaboration,
P. Brun,
A. Caldwell,
L. Chevalier,
G. Dvali,
P. Freire,
E. Garutti,
S. Heyminck,
J. Jochum,
S. Knirck,
M. Kramer,
C. Krieger,
T. Lasserre,
C. Lee,
X. Li,
A. Lindner,
B. Majorovits,
S. Martens,
M. Matysek,
A. Millar,
G. Raffelt,
J. Redondo,
O. Reimann,
A. Ringwald,
K. Saikawa
, et al. (6 additional authors not shown)
Abstract:
The axion emerges in extensions of the Standard Model that explain the absence of CP violation in the strong interactions. Simultaneously, it can provide naturally the cold dark matter in our universe. Several searches for axions and axion-like particles (ALPs) have constrained the corresponding parameter space over the last decades but no unambiguous hints of their existence have been found. The…
▽ More
The axion emerges in extensions of the Standard Model that explain the absence of CP violation in the strong interactions. Simultaneously, it can provide naturally the cold dark matter in our universe. Several searches for axions and axion-like particles (ALPs) have constrained the corresponding parameter space over the last decades but no unambiguous hints of their existence have been found. The axion mass range below 1 meV remains highly attractive and a well motivated region for dark matter axions. In this White Paper we present a description of a new experiment based on the concept of a dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. This MAgnetized Disk and Mirror Axion eXperiment (MADMAX) will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable emission of axion induced electromagnetic waves at a frequency between 10 to 100 GHz corresponding to the axion mass.
△ Less
Submitted 28 October, 2020; v1 submitted 22 January, 2019;
originally announced January 2019.
-
A novel detector system for KATRIN to search for keV-scale sterile neutrinos
Authors:
Susanne Mertens,
Antonio Alborini,
Konrad Altenmüller,
Tobias Bode,
Luca Bombelli,
Tim Brunst,
Marco Carminati,
David Fink,
Carlo Fiorini,
Thibaut Houdy,
Anton Huber,
Marc Korzeczek,
Thierry Lasserre,
Peter Lechner,
Michele Manotti,
Ivan Peric,
David C. Radford,
Daniel Siegmann,
Martin Slezák,
Kathrin Valerius,
Joachim Wolf,
Sascha Wüstling
Abstract:
Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. If their mass is in the kilo-electron-volt regime, they are viable dark matter candidates. One way to search for sterile neutrinos in a laboratory-based experiment is via tritium-beta decay, where the new neutrino mass eigenstate would manifest itself as a kink-like distortion of the $β$-decay spectrum. The object…
▽ More
Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. If their mass is in the kilo-electron-volt regime, they are viable dark matter candidates. One way to search for sterile neutrinos in a laboratory-based experiment is via tritium-beta decay, where the new neutrino mass eigenstate would manifest itself as a kink-like distortion of the $β$-decay spectrum. The objective of the TRISTAN project is to extend the KATRIN setup with a new multi-pixel silicon drift detector system to search for a keV-scale sterile neutrino signal. In this paper we describe the requirements of such a new detector, and present first characterization measurement results obtained with a 7-pixel prototype system.
△ Less
Submitted 15 October, 2018;
originally announced October 2018.
-
The KATRIN Superconducting Magnets: Overview and First Performance Results
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (99 additional authors not shown)
Abstract:
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet sy…
▽ More
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064~m to 9~m, depending on the magnetic flux density along the beam line. Two transport and tritium pum** sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70$\%$ of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01$\%$ per month at 70$\%$ of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.
△ Less
Submitted 22 June, 2018; v1 submitted 21 June, 2018;
originally announced June 2018.
-
Muon-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel
, et al. (109 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of part…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of particular concern. Coincidence measurements with the MS and a scintillator-based muon detector system confirmed the model of secondary electron production by cosmic-ray muons inside the MS. Correlation measurements with the same setup showed that about $12\%$ of secondary electrons emitted from the inner surface are induced by cosmic-ray muons, with approximately one secondary electron produced for every 17 muon crossings. However, the magnetic and electrostatic shielding of the MS is able to efficiently suppress these electrons, and we find that muons are responsible for less than $17\%$ ($90\%$ confidence level) of the overall MS background.
△ Less
Submitted 13 December, 2018; v1 submitted 30 May, 2018;
originally announced May 2018.
-
Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment
Authors:
KATRIN Collaboration,
M. Arenz,
W. -J. Baek,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
R. Berendes,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
W. Buglak,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (105 additional authors not shown)
Abstract:
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such…
▽ More
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such as $\textsuperscript{219}$Rn and $\textsuperscript{220}$Rn, in the spectrometer volume. Active and passive countermeasures have been implemented and tested at the KATRIN main spectrometer. One of these is the magnetic pulse method, which employs the existing air coil system to reduce the magnetic guiding field in the spectrometer on a short timescale in order to remove low- and high-energy stored electrons. Here we describe the working principle of this method and present results from commissioning measurements at the main spectrometer. Simulations with the particle-tracking software Kassiopeia were carried out to gain a detailed understanding of the electron storage conditions and removal processes.
△ Less
Submitted 3 May, 2018;
originally announced May 2018.
-
Yields and production rates of cosmogenic $^9$Li and $^8$He measured with the Double Chooz near and far detectors
Authors:
H. de Kerret,
T. Abrahão,
H. Almazan,
J. C. dos Anjos,
S. Appel,
J. C. Barriere,
I. Bekman,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
M. Cerrada,
E. Chauveau,
P. Chimenti,
O. Corpace,
J. V. Dawson,
Z. Djurcic,
A. Etenko,
D. Franco,
H. Furuta,
I. Gil-Botella,
A. Givaudan
, et al. (73 additional authors not shown)
Abstract:
The yields and production rates of the radioisotopes $^9$Li and $^8$He created by cosmic muon spallation on $^{12}$C, have been measured by the two detectors of the Double Chooz experiment. The identical detectors are located at separate sites and depths, which means they are subject to different muon spectra. The near (far) detector has an overburden of $\sim$120 m.w.e. ($\sim$300 m.w.e.) corresp…
▽ More
The yields and production rates of the radioisotopes $^9$Li and $^8$He created by cosmic muon spallation on $^{12}$C, have been measured by the two detectors of the Double Chooz experiment. The identical detectors are located at separate sites and depths, which means they are subject to different muon spectra. The near (far) detector has an overburden of $\sim$120 m.w.e. ($\sim$300 m.w.e.) corresponding to a mean muon energy of $32.1\pm2.0\,\mathrm{GeV}$ ($63.7\pm5.5\,\mathrm{GeV}$). Comparing the data to a detailed simulation of the $^9$Li and $^8$He decays, the contribution of the $^8$He radioisotope at both detectors is found to be compatible with zero. The observed $^9$Li yields in the near and far detectors are $5.51\pm0.51$ and $7.90\pm0.51$, respectively, in units of $10^{-8}μ^{-1} \mathrm{g^{-1} cm^{2} }$. The shallow overburdens of the near and far detectors give a unique insight when combined with measurements by KamLAND and Borexino to give the first multi--experiment, data driven relationship between the $^9$Li yield and the mean muon energy according to the power law $Y = Y_0( <E_μ >/ 1\,\mathrm{GeV})^{\overlineα}$, giving $\overlineα=0.72\pm0.06$ and $Y_0=(0.43\pm0.11)\times 10^{-8}μ^{-1} \mathrm{g^{-1} cm^{2}}$. This relationship gives future liquid scintillator based experiments the ability to predict their cosmogenic $^9$Li background rates.
△ Less
Submitted 10 October, 2018; v1 submitted 22 February, 2018;
originally announced February 2018.
-
Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (102 additional authors not shown)
Abstract:
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage divid…
▽ More
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two $^{83\mathrm{m}}$Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor $M=1972.449(10)$ of the high-voltage divider K35 is in agreement with the last PTB calibration four years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.
△ Less
Submitted 15 May, 2018; v1 submitted 14 February, 2018;
originally announced February 2018.
-
First transmission of electrons and ions through the KATRIN beamline
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (104 additional authors not shown)
Abstract:
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons fr…
▽ More
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of Autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous Kr-83m was injected into the KATRIN source section, and a condensed Kr-83m source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. We have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.
△ Less
Submitted 7 July, 2018; v1 submitted 12 February, 2018;
originally announced February 2018.
-
Detector Development for a Sterile Neutrino Search with the KATRIN Experiment
Authors:
Tim Brunst,
Konrad Altenmüller,
Tobias Bode,
Luca Bombelli,
Vasiliy Chernov,
Anton Huber,
Marc Korzeczek,
Thierry Lasserre,
Peter Lechner,
Susanne Mertens,
Aleksander Nozik,
Vladislav Pantuev,
Daniel Siegmann,
Aino Skasyrskaya
Abstract:
The KATRIN (Karlsruhe Tritium Neutrino) experiment investigates the energetic endpoint of the tritium $β$-decay spectrum to determine the effective mass of the electron anti-neutrino with a precision of $200\,\mathrm{meV}$ ($90\,\%$ C.L.) after an effective data taking time of three years.
The TRISTAN (tritium $β$-decay to search for sterile neutrinos) group aims to detect a sterile neutrino sig…
▽ More
The KATRIN (Karlsruhe Tritium Neutrino) experiment investigates the energetic endpoint of the tritium $β$-decay spectrum to determine the effective mass of the electron anti-neutrino with a precision of $200\,\mathrm{meV}$ ($90\,\%$ C.L.) after an effective data taking time of three years.
The TRISTAN (tritium $β$-decay to search for sterile neutrinos) group aims to detect a sterile neutrino signature by measuring the entire tritium $β$-decay spectrum with an upgraded KATRIN system. One of the greatest challenges is to handle the high signal rates generated by the strong activity of the KATRIN tritium source. Therefore, a novel multi-pixel silicon drift detector is being designed, which is able to handle rates up to $10^{8}\,\mathrm{cps}$ with an excellent energy resolution of $<200\,\mathrm{eV}$ (FWHM) at $10\,\mathrm{keV}$.
This work gives an overview of the ongoing detector development and test results of the first seven pixel prototype detectors.
△ Less
Submitted 24 January, 2018;
originally announced January 2018.
-
Novel event classification based on spectral analysis of scintillation waveforms in Double Chooz
Authors:
T. Abrahão,
H. Almazan,
J. C. dos Anjos,
S. Appel,
I. Bekman,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
L. Camilleri,
M. Cerrada,
E. Chauveau,
P. Chimenti,
O. Corpace,
J. I. Crespo-Anadón,
J. V. Dawson,
Z. Djurcic,
A. Etenko,
M. Fallot,
D. Franco,
H. Furuta,
I. Gil-Botella
, et al. (72 additional authors not shown)
Abstract:
Liquid scintillators are a common choice for neutrino physics experiments, but their capabilities to perform background rejection by scintillation pulse shape discrimination is generally limited in large detectors. This paper describes a novel approach for a pulse shape based event classification developed in the context of the Double Chooz reactor antineutrino experiment. Unlike previous implemen…
▽ More
Liquid scintillators are a common choice for neutrino physics experiments, but their capabilities to perform background rejection by scintillation pulse shape discrimination is generally limited in large detectors. This paper describes a novel approach for a pulse shape based event classification developed in the context of the Double Chooz reactor antineutrino experiment. Unlike previous implementations, this method uses the Fourier power spectra of the scintillation pulse shapes to obtain event-wise information. A classification variable built from spectral information was able to achieve an unprecedented performance, despite the lack of optimization at the detector design level. Several examples of event classification are provided, ranging from differentiation between the detector volumes and an efficient rejection of instrumental light noise, to some sensitivity to the particle type, such as stop** muons, ortho-positronium formation, alpha particles as well as electrons and positrons. In combination with other techniques the method is expected to allow for a versatile and more efficient background rejection in the future, especially if detector optimization is taken into account at the design level.
△ Less
Submitted 18 January, 2018; v1 submitted 11 October, 2017;
originally announced October 2017.
-
Reactor antineutrino shoulder explained by energy scale nonlinearities?
Authors:
G. Mention,
M. Vivier,
J. Gaffiot,
T. Lasserre,
A. Letourneau,
T. Materna
Abstract:
The Daya Bay, Double Chooz and RENO experiments recently observed a significant distortion in their detected reactor antineutrino spectra, being at odds with the current predictions. Although such a result suggests to revisit the current reactor antineutrino spectra modeling, an alternative scenario, which could potentially explain this anomaly, is explored in this letter. Using an appropriate sta…
▽ More
The Daya Bay, Double Chooz and RENO experiments recently observed a significant distortion in their detected reactor antineutrino spectra, being at odds with the current predictions. Although such a result suggests to revisit the current reactor antineutrino spectra modeling, an alternative scenario, which could potentially explain this anomaly, is explored in this letter. Using an appropriate statistical method, a study of the Daya Bay experiment energy scale is performed. While still being in agreement with the γ calibration data and Boron 12 measured spectrum, it is shown that a O(1%) deviation of the energy scale reproduces the distortion observed in the Daya Bay spectrum, remaining within the quoted calibration uncertainties. Potential origins of such a deviation, which challenge the energy calibration of these detectors, are finally discussed.
△ Less
Submitted 26 May, 2017;
originally announced May 2017.
-
Coherent Neutrino Scattering with Low Temperature Bolometers at Chooz Reactor Complex
Authors:
J. Billard,
R. Carr,
J. Dawson,
E. Figueroa-Feliciano,
J. A. Formaggio,
J. Gascon,
M. De Jesus,
J. Johnston,
T. Lasserre,
A. Leder,
K. J. Palladino,
S. H. Trowbridge,
M. Vivier,
L. Winslow
Abstract:
We present the potential sensitivity of a future recoil detector for a first detection of the process of coherent elastic neutrino nucleus scattering (CE$ν$NS). We use the Chooz reactor complex in France as our luminous source of reactor neutrinos. Leveraging the ability to cleanly separate the rate correlated with the reactor thermal power against (uncorrelated) backgrounds, we show that a 10 kil…
▽ More
We present the potential sensitivity of a future recoil detector for a first detection of the process of coherent elastic neutrino nucleus scattering (CE$ν$NS). We use the Chooz reactor complex in France as our luminous source of reactor neutrinos. Leveraging the ability to cleanly separate the rate correlated with the reactor thermal power against (uncorrelated) backgrounds, we show that a 10 kilogram cryogenic bolometric array with 100 eV threshold should be able to extract a CE$ν$NS signal within one year of running.
△ Less
Submitted 20 September, 2017; v1 submitted 25 December, 2016;
originally announced December 2016.
-
Impact of ADC non-linearities on the sensitivity to sterile keV neutrinos with a KATRIN-like experiment
Authors:
K. Dolde,
S. Mertens,
D. Radford,
T. Bode,
A. Huber,
M. Korzeczek,
T. Lasserre,
M. Slezak
Abstract:
ADC non-linearities are a major systematic effect in the search for keV-scale sterile neutrinos with tritium $β$-decay experiments like KATRIN. They can significantly distort the spectral shape and thereby obscure the tiny kink-like signature of a sterile neutrino. In this work we demonstrate various mitigation techniques to reduce the impact of ADC non-linearities on the tritium $β$-decay spectru…
▽ More
ADC non-linearities are a major systematic effect in the search for keV-scale sterile neutrinos with tritium $β$-decay experiments like KATRIN. They can significantly distort the spectral shape and thereby obscure the tiny kink-like signature of a sterile neutrino. In this work we demonstrate various mitigation techniques to reduce the impact of ADC non-linearities on the tritium $β$-decay spectrum to a level of $<$ ppm. The best results are achieved with a multi-pixel ($\geq10^4$ pixels) detector using full waveform digitization. In this case, active-to-sterile mixing angles of the order of $\sin^2 θ= 10^{-7}$ would be accessible from the viewpoint of ADC non-linearities. With purely peak-sensing ADCs a comparable sensitivity could be reached with highly linear ADCs, sufficient non-linearity corrections or by increasing the number of pixels to $\geq 10^5$.
△ Less
Submitted 10 August, 2016;
originally announced August 2016.
-
Characterization of the Spontaneous Light Emission of the PMTs used in the Double Chooz Experiment
Authors:
Double Chooz collaboration,
Y. Abe,
T. Abrahão,
H. Almazan,
C. Alt,
S. Appel,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Calvo,
L. Camilleri,
R. Carr,
M. Cerrada,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad
, et al. (124 additional authors not shown)
Abstract:
During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical volume has been observed. A specific study of the ensemble of phenomena called "Light Noise" has been carried out in-situ, and in an external laboratory, in order to characterize the signals and to identify the possible…
▽ More
During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical volume has been observed. A specific study of the ensemble of phenomena called "Light Noise" has been carried out in-situ, and in an external laboratory, in order to characterize the signals and to identify the possible processes underlying the effect. Some mechanisms of instrumental noise originating from the PMTs were identified and it has been found that the leading one arises from the light emission localized on the photomultiplier base and produced by the combined effect of heat and high voltage across the transparent epoxy resin covering the electric components. The correlation of the rate and the amplitude of the signal with the temperature has been observed. For the first detector in operation the induced background has been mitigated using online and offline analysis selections based on timing and light pattern of the signals, while a modification of the photomultiplier assembly has been implemented for the second detector in order to blacken the PMT bases.
△ Less
Submitted 17 August, 2016; v1 submitted 23 April, 2016;
originally announced April 2016.
-
Muon capture on light isotopes in Double Chooz
Authors:
Double Chooz collaboration,
Y. Abe,
T. Abrahão,
H. Almazan,
C. Alt,
S. Appel,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
L. Camilleri,
R. Carr,
M. Cerrada,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad
, et al. (122 additional authors not shown)
Abstract:
Using the Double Chooz detector, designed to measure the neutrino mixing angle $θ_{13}$, the products of $μ^-$ capture on $^{12}$C, $^{13}$C, $^{14}$N and $^{16}$O have been measured. Over a period of 489.5 days, $2.3\times10^6$ stop** cosmic $μ^-$ have been collected, of which $1.8\times10^5$ captured on carbon, nitrogen, or oxygen nuclei in the inner detector scintillator or acrylic vessels. T…
▽ More
Using the Double Chooz detector, designed to measure the neutrino mixing angle $θ_{13}$, the products of $μ^-$ capture on $^{12}$C, $^{13}$C, $^{14}$N and $^{16}$O have been measured. Over a period of 489.5 days, $2.3\times10^6$ stop** cosmic $μ^-$ have been collected, of which $1.8\times10^5$ captured on carbon, nitrogen, or oxygen nuclei in the inner detector scintillator or acrylic vessels. The resulting isotopes were tagged using prompt neutron emission (when applicable), the subsequent beta decays, and, in some cases, $β$-delayed neutrons. The most precise measurement of the rate of $^{12}\mathrm C(μ^-,ν)^{12}\mathrm B$ to date is reported: $6.57^{+0.11}_{-0.21}\times10^{3}\,\mathrm s^{-1}$, or $(17.35^{+0.35}_{-0.59})\%$ of nuclear captures. By tagging excited states emitting gammas, the ground state transition rate to $^{12}$B has been determined to be $5.68^{+0.14}_{-0.23}\times10^3\,\mathrm s^{-1}$. The heretofore unobserved reactions $^{12}\mathrm C(μ^-,να)^{8}\mathrm{Li}$, $^{13}\mathrm C(μ^-,ν\mathrm nα)^{8}\mathrm{Li}$, and $^{13}\mathrm C(μ^-,ν\mathrm n)^{12}\mathrm B$ are measured. Further, a population of $β$n decays following stop** muons is identified with $5.5σ$ significance. Statistics limit our ability to identify these decays definitively. Assuming negligible production of $^{8}$He, the reaction $^{13}\mathrm C(μ^-,να)^{9}\mathrm{Li}$ is found to be present at the $2.7σ$ level. Limits are set on a variety of other processes.
△ Less
Submitted 17 May, 2016; v1 submitted 23 December, 2015;
originally announced December 2015.
-
Measurement of $θ_{13}$ in Double Chooz using neutron captures on hydrogen with novel background rejection techniques
Authors:
Y. Abe,
S. Appel,
T. Abrahão,
H. Almazan,
C. Alt,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
L. Camilleri,
R. Carr,
M. Cerrada,
E. Chauveau,
P. Chimenti,
A. P. Collin,
J. M. Conrad,
J. I. Crespo-Anadón
, et al. (120 additional authors not shown)
Abstract:
The Double Chooz collaboration presents a measurement of the neutrino mixing angle $θ_{13}$ using reactor $\overlineν_{e}$ observed via the inverse beta decay reaction in which the neutron is captured on hydrogen. This measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050…
▽ More
The Double Chooz collaboration presents a measurement of the neutrino mixing angle $θ_{13}$ using reactor $\overlineν_{e}$ observed via the inverse beta decay reaction in which the neutron is captured on hydrogen. This measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050m from two reactor cores. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties. Accidental coincidences, the dominant background in this analysis, are suppressed by more than an order of magnitude with respect to our previous publication by a multi-variate analysis. These improvements demonstrate the capability of precise measurement of reactor $\overlineν_{e}$ without gadolinium loading. Spectral distortions from the $\overlineν_{e}$ reactor flux predictions previously reported with the neutron capture on gadolinium events are confirmed in the independent data sample presented here. A value of $\sin^{2}2θ_{13} = 0.095^{+0.038}_{-0.039}$(stat+syst) is obtained from a fit to the observed event rate as a function of the reactor power, a method insensitive to the energy spectrum shape. A simultaneous fit of the hydrogen capture events and of the gadolinium capture events yields a measurement of $\sin^{2}2θ_{13} = 0.088\pm0.033$(stat+syst).
△ Less
Submitted 28 December, 2015; v1 submitted 29 October, 2015;
originally announced October 2015.
-
Online Monitoring of the Osiris Reactor with the Nucifer Neutrino Detector
Authors:
G. Boireau,
L. Bouvet,
A. P. Collin,
G. Coulloux,
M. Cribier,
H. Deschamp,
V. Durand,
M. Fechner,
V. Fischer,
J. Gaffiot,
N. Gerard Castaing,
R. Granelli,
Y. Kato,
T. Lasserre,
L. Latron,
P. Legou,
A. Letourneau,
D. Lhuillier,
G. Mention,
T. Mueller,
T-A. Nghiem,
N. Pedrol,
J. Pelzer,
M. Pequignot,
Y. Piret
, et al. (29 additional authors not shown)
Abstract:
Originally designed as a new nuclear reactor monitoring device, the Nucifer detector has successfully detected its first neutrinos. We provide the second shortest baseline measurement of the reactor neutrino flux. The detection of electron antineutrinos emitted in the decay chains of the fission products, combined with reactor core simulations, provides an new tool to assess both the thermal power…
▽ More
Originally designed as a new nuclear reactor monitoring device, the Nucifer detector has successfully detected its first neutrinos. We provide the second shortest baseline measurement of the reactor neutrino flux. The detection of electron antineutrinos emitted in the decay chains of the fission products, combined with reactor core simulations, provides an new tool to assess both the thermal power and the fissile content of the whole nuclear core and could be used by the Inter- national Agency for Atomic Energy (IAEA) to enhance the Safeguards of civil nuclear reactors. Deployed at only 7.2m away from the compact Osiris research reactor core (70MW) operating at the Saclay research centre of the French Alternative Energies and Atomic Energy Commission (CEA), the experiment also exhibits a well-suited configuration to search for a new short baseline oscillation. We report the first results of the Nucifer experiment, describing the performances of the 0.85m3 detector remotely operating at a shallow depth equivalent to 12m of water and under intense background radiation conditions. Based on 145 (106) days of data with reactor ON (OFF), leading to the detection of an estimated 40760 electron antineutrinos, the mean number of detected antineutrinos is 281 +- 7(stat) +- 18(syst) electron antineutrinos/day, in agreement with the prediction 277(23) electron antineutrinos/day. Due the the large background no conclusive results on the existence of light sterile neutrinos could be derived, however. As a first societal application we quantify how antineutrinos could be used for the Plutonium Management and Disposition Agreement.
△ Less
Submitted 25 May, 2016; v1 submitted 18 September, 2015;
originally announced September 2015.
-
Prompt directional detection of galactic supernova by combining large liquid scintillator neutrino detectors
Authors:
V. Fischer,
T. Chirac,
T. Lasserre,
C. Volpe,
M. Cribier,
M. Durero,
J. Gaffiot,
T. Houdy,
A. Letourneau,
G. Mention,
M. Pequignot,
V. Sibille,
M. Vivier
Abstract:
Core-collapse supernovae produce an intense burst of electron antineutrinos in the few-tens-of-MeV range. Several Large Liquid Scintillator-based Detectors (LLSD) are currently operated worldwide, being very effective for low energy antineutrino detection through the Inverse Beta Decay (IBD) process. In this article, we develop a procedure for the prompt extraction of the supernova location by rev…
▽ More
Core-collapse supernovae produce an intense burst of electron antineutrinos in the few-tens-of-MeV range. Several Large Liquid Scintillator-based Detectors (LLSD) are currently operated worldwide, being very effective for low energy antineutrino detection through the Inverse Beta Decay (IBD) process. In this article, we develop a procedure for the prompt extraction of the supernova location by revisiting the details of IBD kinematics over the broad energy range of supernova neutrinos. Combining all current scintillator-based detector, we show that one can locate a canonical supernova at 10 kpc with an accuracy of 45 degrees (68% C.L.). After the addition of the next generation of scintillator-based detectors, the accuracy could reach 12 degrees (68% C.L.), therefore reaching the performances of the large water Cerenkov neutrino detectors. We also discuss a possible improvement of the SuperNova Early Warning System (SNEWS) inter-experiment network with the implementation of a directionality information in each experiment. Finally, we discuss the possibility to constrain the neutrino energy spectrum as well as the mass of the newly born neutron star with the LLSD data
△ Less
Submitted 25 August, 2015; v1 submitted 21 April, 2015;
originally announced April 2015.
-
Experimental Parameters for a Cerium 144 Based Intense Electron Antineutrino Generator Experiment at Very Short Baselines
Authors:
J. Gaffiot,
T. Lasserre,
G. Mention,
M. Vivier,
M. Cribier,
M. Durero,
V. Fischer,
A. Letourneau,
E. Dumonteil,
I. S. Saldikov,
G. V. Tikhomirov
Abstract:
The standard three-neutrino oscillation paradigm, associated with small squared mass splittings $\ll 0.1\ \mathrm{eV^2}$, has been successfully built up over the last 15 years using solar, atmospheric, long baseline accelerator and reactor neutrino experiments. However, this well-established picture might suffer from anomalous results reported at very short baselines in some of these experiments.…
▽ More
The standard three-neutrino oscillation paradigm, associated with small squared mass splittings $\ll 0.1\ \mathrm{eV^2}$, has been successfully built up over the last 15 years using solar, atmospheric, long baseline accelerator and reactor neutrino experiments. However, this well-established picture might suffer from anomalous results reported at very short baselines in some of these experiments. If not experimental artifacts, such results could possibly be interpreted as the existence of at least an additional fourth sterile neutrino species, mixing with the known active flavors with an associated mass splitting $\ll 0.1\ \mathrm{eV^2}$, and being insensitive to standard weak interactions. Precision measurements at very short baselines (5 to 15 m) with intense MeV electronic antineutrino emitters can be used to probe these anomalies. In this article, the expected antineutrino signal and backgrounds of a generic experiment which consists of deploying an intense beta minus radioactive source inside or in the vicinity of a large liquid scintillator detector are studied. The technical challenges to perform such an experiment are identified, along with quantifying the possible source and detector induced systematics, and their impact on the sensitivity to the observation of neutrino oscillations at short baselines.
△ Less
Submitted 9 February, 2015; v1 submitted 24 November, 2014;
originally announced November 2014.
-
Sensitivity of Next-Generation Tritium Beta-Decay Experiments for keV-Scale Sterile Neutrinos
Authors:
S. Mertens,
T. Lasserre,
S. Groh,
F. Glueck,
A. Huber,
A. W. P. Poon,
M. Steidl,
N. Steinbrink,
C. Weinheimer
Abstract:
We investigate the sensitivity of tritium $β$-decay experiments for keV-scale sterile neutrinos. Relic sterile neutrinos in the keV mass range can contribute both to the cold and warm dark matter content of the universe. This work shows that a large-scale tritium beta-decay experiment, similar to the KATRIN experiment that is under construction, can reach a statistical sensitivity of the active-st…
▽ More
We investigate the sensitivity of tritium $β$-decay experiments for keV-scale sterile neutrinos. Relic sterile neutrinos in the keV mass range can contribute both to the cold and warm dark matter content of the universe. This work shows that a large-scale tritium beta-decay experiment, similar to the KATRIN experiment that is under construction, can reach a statistical sensitivity of the active-sterile neutrino mixing of $\sin^2θ\sim 10^{-8}$. The effect of uncertainties in the known theoretical corrections to the tritium $β$-decay spectrum were investigated, and found not to affect the sensitivity significantly. It is demonstrated that controlling uncorrelated systematic effects will be one of the main challenges in such an experiment.
△ Less
Submitted 14 December, 2014; v1 submitted 2 September, 2014;
originally announced September 2014.
-
Ortho-positronium observation in the Double Chooz Experiment
Authors:
Y. Abe,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadon,
K. Crum,
A. S. Cucoanes
, et al. (121 additional authors not shown)
Abstract:
The Double Chooz experiment measures the neutrino mixing angle $θ_{13}$ by detecting reactor $\barν_e$ via inverse beta decay. The positron-neutron space and time coincidence allows for a sizable background rejection, nonetheless liquid scintillator detectors would profit from a positron/electron discrimination, if feasible in large detector, to suppress the remaining background. Standard particle…
▽ More
The Double Chooz experiment measures the neutrino mixing angle $θ_{13}$ by detecting reactor $\barν_e$ via inverse beta decay. The positron-neutron space and time coincidence allows for a sizable background rejection, nonetheless liquid scintillator detectors would profit from a positron/electron discrimination, if feasible in large detector, to suppress the remaining background. Standard particle identification, based on particle dependent time profile of photon emission in liquid scintillator, can not be used given the identical mass of the two particles. However, the positron annihilation is sometimes delayed by the ortho-positronium (o-Ps) metastable state formation, which induces a pulse shape distortion that could be used for positron identification. In this paper we report on the first observation of positronium formation in a large liquid scintillator detector based on pulse shape analysis of single events. The o-Ps formation fraction and its lifetime were measured, finding the values of 44$\%$ $\pm$ 12$\%$ (sys.) $\pm$ 5$\%$ (stat.) and $3.68$ns $\pm$ 0.17ns (sys.) $\pm$ 0.15ns (stat.) respectively, in agreement with the results obtained with a dedicated positron annihilation lifetime spectroscopy setup.
△ Less
Submitted 7 October, 2014; v1 submitted 25 July, 2014;
originally announced July 2014.
-
Improved measurements of the neutrino mixing angle $θ_{13}$ with the Double Chooz detector
Authors:
Y. Abe,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadón,
K. Crum,
A. S. Cucoanes
, et al. (121 additional authors not shown)
Abstract:
The Double Chooz experiment presents improved measurements of the neutrino mixing angle $θ_{13}$ using the data collected in 467.90 live days from a detector positioned at an average distance of 1050 m from two reactor cores at the Chooz nuclear power plant. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties with respect t…
▽ More
The Double Chooz experiment presents improved measurements of the neutrino mixing angle $θ_{13}$ using the data collected in 467.90 live days from a detector positioned at an average distance of 1050 m from two reactor cores at the Chooz nuclear power plant. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties with respect to previous publications, whereas the efficiency of the $\barν_{e}$ signal has increased. The value of $θ_{13}$ is measured to be $\sin^{2}2θ_{13} = 0.090 ^{+0.032}_{-0.029}$ from a fit to the observed energy spectrum. Deviations from the reactor $\barν_{e}$ prediction observed above a prompt signal energy of 4 MeV and possible explanations are also reported. A consistent value of $θ_{13}$ is obtained from a fit to the observed rate as a function of the reactor power independently of the spectrum shape and background estimation, demonstrating the robustness of the $θ_{13}$ measurement despite the observed distortion.
△ Less
Submitted 21 January, 2015; v1 submitted 30 June, 2014;
originally announced June 2014.
-
Precision Muon Reconstruction in Double Chooz
Authors:
Double Chooz collaboration,
Y. Abe,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadón,
K. Crum
, et al. (119 additional authors not shown)
Abstract:
We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volu…
▽ More
We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volumes. All muons are fit under the hypothesis that they are through-going and ultrarelativistic. If the energy depositions suggest that the muon may have stopped, the reconstruction fits also for this hypothesis and chooses between the two via the relative goodness-of-fit. In the ideal case of a through-going muon intersecting the center of the detector, the resolution is ~40 mm in each transverse dimension. High quality muon reconstruction is an important tool for reducing the impact of the cosmogenic isotope background in Double Chooz.
△ Less
Submitted 15 August, 2014; v1 submitted 23 May, 2014;
originally announced May 2014.
-
CeLAND: search for a 4th light neutrino state with a 3 PBq 144Ce-144Pr electron antineutrino generator in KamLAND
Authors:
A. Gando,
Y. Gando,
S. Hayashida,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
H. Ishikawa,
M. Koga,
R. Matsuda,
S. Matsuda,
T. Mitsui,
D. Motoki,
K. Nakamura,
Y. Oki,
M. Otani,
I. Shimizu,
J. Shirai,
F. Suekane,
A. Suzuki,
Y. Takemoto,
K. Tamae,
K. Ueshima,
H. Watanabe,
B. D. Xu,
S. Yamada
, et al. (41 additional authors not shown)
Abstract:
The reactor neutrino and gallium anomalies can be tested with a 3-4 PBq (75-100 kCi scale) 144Ce-144Pr antineutrino beta-source deployed at the center or next to a large low-background liquid scintillator detector. The antineutrino generator will be produced by the Russian reprocessing plant PA Mayak as early as 2014, transported to Japan, and deployed in the Kamioka Liquid Scintillator Anti-Neutr…
▽ More
The reactor neutrino and gallium anomalies can be tested with a 3-4 PBq (75-100 kCi scale) 144Ce-144Pr antineutrino beta-source deployed at the center or next to a large low-background liquid scintillator detector. The antineutrino generator will be produced by the Russian reprocessing plant PA Mayak as early as 2014, transported to Japan, and deployed in the Kamioka Liquid Scintillator Anti-Neutrino Detector (KamLAND) as early as 2015. KamLAND's 13 m diameter target volume provides a suitable environment to measure the energy and position dependence of the detected neutrino flux. A characteristic oscillation pattern would be visible for a baseline of about 10 m or less, providing a very clean signal of neutrino disappearance into a yet-unknown, sterile neutrino state. This will provide a comprehensive test of the electron dissaperance neutrino anomalies and could lead to the discovery of a 4th neutrino state for Delta_m^2 > 0.1 eV^2 and sin^2(2theta) > 0.05.
△ Less
Submitted 13 April, 2014; v1 submitted 3 December, 2013;
originally announced December 2013.