Data Format Standardization and DICOM Integration for Hyperpolarized 13C MRI
Authors:
Ernesto Diaz,
Renuka Sriram,
Jeremy W. Gordon,
Avantika Sinha,
Xiaoxi Liu,
Sule Sahin,
Jason Crane,
Marram P Olson,
Hsin-Yu Chen,
Jenna Bernard,
Daniel B. Vigneron,
Zhen Jane Wang,
Duan Xu,
Peder E. Z. Larson
Abstract:
Hyperpolarized (HP) 13C MRI has shown promise as a valuable modality for in vivo measurements of metabolism and is currently in human trials at 15 research sites worldwide. With this growth it is important to adopt standardized data storage practices as it will allow sites to meaningfully compare data.
In this paper we (1) describe data that we believe should be stored and (2) demonstrate pipeli…
▽ More
Hyperpolarized (HP) 13C MRI has shown promise as a valuable modality for in vivo measurements of metabolism and is currently in human trials at 15 research sites worldwide. With this growth it is important to adopt standardized data storage practices as it will allow sites to meaningfully compare data.
In this paper we (1) describe data that we believe should be stored and (2) demonstrate pipelines and methods that utilize the Digital Imaging and Communications in Medicine (DICOM) standard. This includes proposing a set of minimum set of information that is specific to HP 13C MRI studies. We then show where the majority of these can be fit into existing DICOM Attributes, primarily via the "Contrast/Bolus" module.
We also demonstrate pipelines for utilizing DICOM for HP 13C MRI. DICOM is the most common standard for clinical medical image storage and provides the flexibility to accommodate the unique aspects of HP 13C MRI, including the HP agent information but also spectroscopic and metabolite dimensions. The pipelines shown include creating DICOM objects for studies on human and animal imaging systems with various pulse sequences. We also show a python-based method to efficiently modify DICOM objects to incorporate the unique HP 13C MRI information that is not captured by existing pipelines. Moreover, we propose best practices for HP 13C MRI data storage that will support future multi-site trials, research studies and technical developments of this imaging technique.
△ Less
Submitted 5 May, 2024;
originally announced May 2024.
-
T2 Relaxation during Radiofrequency (RF) pulses
Authors:
Peder E. Z. Larson
Abstract:
Radiofrequency (RF) pulses are a critical part of every MRI pulse sequence, and must be specifically designed for ultrashort echo time (UTE) and zero echo time (ZTE) acquisitions. When considering the behavior of RF pulses, most often longitudinal T1 or transverse T2 relaxation is assumed to be negligible during the RF pulses themselves. This is usually valid with conventional sequences since most…
▽ More
Radiofrequency (RF) pulses are a critical part of every MRI pulse sequence, and must be specifically designed for ultrashort echo time (UTE) and zero echo time (ZTE) acquisitions. When considering the behavior of RF pulses, most often longitudinal T1 or transverse T2 relaxation is assumed to be negligible during the RF pulses themselves. This is usually valid with conventional sequences since most tissue T1s and T2s are much longer than typical RF pulse durations. However, when imaging tissues that have transverse relaxation times that are of the order of, or shorter than, the RF pulse duration, as is often the case with UTE and ZTE MRI, then relaxation during the pulse must be considered. This article covers the theory of T2/T2* relaxation during an RF pulse, and the implications and applications of this for imaging of ultrashort-T2* species.
△ Less
Submitted 1 December, 2023;
originally announced December 2023.
-
Lung Imaging with UTE MRI
Authors:
Peder E. Z. Larson
Abstract:
Cross-sectional imaging of the lungs, or pulmonary imaging, has proven to be an incredibly valuable tool in a wide range of pulmonary diseases. The vast majority of lung imaging is done with CT, as it is fast enough to freeze respiratory motion and provides high spatial resolution to visualize fine structure of the lungs.
MRI of the lungs is inherently challenging due to the presence of large lo…
▽ More
Cross-sectional imaging of the lungs, or pulmonary imaging, has proven to be an incredibly valuable tool in a wide range of pulmonary diseases. The vast majority of lung imaging is done with CT, as it is fast enough to freeze respiratory motion and provides high spatial resolution to visualize fine structure of the lungs.
MRI of the lungs is inherently challenging due to the presence of large local magnetic field gradients, relatively low proton density, and motion. The benefits of performing MRI for lung imaging include no ionizing radiation, opportunities for multiple contrasts, and integration with other MRI also offers the opportunity to obtain multiple tissue contrasts.
The most common lung MRI techniques are structural T1-weighted scans, but also emerging are functional contrasts such as ventilation and perfusion, as well as other MRI contrast mechanisms including T2-weighting and diffusion-weighting. Finally, lung MRI can be combined with other MRI scanning techniques, including cardiac MRI, abdominal MRI, whole-body MRI, and PET/MRI, for increasing examination efficiency by only requiring a single scan session and providing more comprehensive assessment that includes evaluation of the pulmonary system.
This article covers pulse sequences, motion management methods, image reconstruction, and contrast mechanisms of UTE MRI (e.g. T1-weighting, ventilation map**) for imaging of the lung.
△ Less
Submitted 1 December, 2023;
originally announced December 2023.
-
Physics-driven Deep Learning for PET/MRI
Authors:
Abhejit Rajagopal,
Andrew P. Leynes,
Nicholas Dwork,
Jessica E. Scholey,
Thomas A. Hope,
Peder E. Z. Larson
Abstract:
In this paper, we review physics- and data-driven reconstruction techniques for simultaneous positron emission tomography (PET) / magnetic resonance imaging (MRI) systems, which have significant advantages for clinical imaging of cancer, neurological disorders, and heart disease. These reconstruction approaches utilize priors, either structural or statistical, together with a physics-based descrip…
▽ More
In this paper, we review physics- and data-driven reconstruction techniques for simultaneous positron emission tomography (PET) / magnetic resonance imaging (MRI) systems, which have significant advantages for clinical imaging of cancer, neurological disorders, and heart disease. These reconstruction approaches utilize priors, either structural or statistical, together with a physics-based description of the PET system response. However, due to the nested representation of the forward problem, direct PET/MRI reconstruction is a nonlinear problem. We elucidate how a multi-faceted approach accommodates hybrid data- and physics-driven machine learning for reconstruction of 3D PET/MRI, summarizing important deep learning developments made in the last 5 years to address attenuation correction, scattering, low photon counts, and data consistency. We also describe how applications of these multi-modality approaches extend beyond PET/MRI to improving accuracy in radiation therapy planning. We conclude by discussing opportunities for extending the current state-of-the-art following the latest trends in physics- and deep learning-based computational imaging and next-generation detector hardware.
△ Less
Submitted 11 June, 2022;
originally announced June 2022.
-
Synthetic PET via Domain Translation of 3D MRI
Authors:
Abhejit Rajagopal,
Yutaka Natsuaki,
Kristen Wangerin,
Mahdjoub Hamdi,
Hongyu An,
John J. Sunderland,
Richard Laforest,
Paul E. Kinahan,
Peder E. Z. Larson,
Thomas A. Hope
Abstract:
Historically, patient datasets have been used to develop and validate various reconstruction algorithms for PET/MRI and PET/CT. To enable such algorithm development, without the need for acquiring hundreds of patient exams, in this paper we demonstrate a deep learning technique to generate synthetic but realistic whole-body PET sinograms from abundantly-available whole-body MRI. Specifically, we u…
▽ More
Historically, patient datasets have been used to develop and validate various reconstruction algorithms for PET/MRI and PET/CT. To enable such algorithm development, without the need for acquiring hundreds of patient exams, in this paper we demonstrate a deep learning technique to generate synthetic but realistic whole-body PET sinograms from abundantly-available whole-body MRI. Specifically, we use a dataset of 56 $^{18}$F-FDG-PET/MRI exams to train a 3D residual UNet to predict physiologic PET uptake from whole-body T1-weighted MRI. In training we implemented a balanced loss function to generate realistic uptake across a large dynamic range and computed losses along tomographic lines of response to mimic the PET acquisition. The predicted PET images are forward projected to produce synthetic PET time-of-flight (ToF) sinograms that can be used with vendor-provided PET reconstruction algorithms, including using CT-based attenuation correction (CTAC) and MR-based attenuation correction (MRAC). The resulting synthetic data recapitulates physiologic $^{18}$F-FDG uptake, e.g. high uptake localized to the brain and bladder, as well as uptake in liver, kidneys, heart and muscle. To simulate abnormalities with high uptake, we also insert synthetic lesions. We demonstrate that this synthetic PET data can be used interchangeably with real PET data for the PET quantification task of comparing CT and MR-based attenuation correction methods, achieving $\leq 7.6\%$ error in mean-SUV compared to using real data. These results together show that the proposed synthetic PET data pipeline can be reasonably used for development, evaluation, and validation of PET/MRI reconstruction methods.
△ Less
Submitted 11 June, 2022;
originally announced June 2022.
-
Scan-specific Self-supervised Bayesian Deep Non-linear Inversion for Undersampled MRI Reconstruction
Authors:
Andrew P. Leynes,
Nikhil Deveshwar,
Srikantan S. Nagarajan,
Peder E. Z. Larson
Abstract:
Magnetic resonance imaging is subject to slow acquisition times due to the inherent limitations in data sampling. Recently, supervised deep learning has emerged as a promising technique for reconstructing sub-sampled MRI. However, supervised deep learning requires a large dataset of fully-sampled data. Although unsupervised or self-supervised deep learning methods have emerged to address the limit…
▽ More
Magnetic resonance imaging is subject to slow acquisition times due to the inherent limitations in data sampling. Recently, supervised deep learning has emerged as a promising technique for reconstructing sub-sampled MRI. However, supervised deep learning requires a large dataset of fully-sampled data. Although unsupervised or self-supervised deep learning methods have emerged to address the limitations of supervised deep learning approaches, they still require a database of images. In contrast, scan-specific deep learning methods learn and reconstruct using only the sub-sampled data from a single scan. Here, we introduce Scan-Specific Self-Supervised Bayesian Deep Non-Linear Inversion (DNLINV) that does not require an auto calibration scan region. DNLINV utilizes a deep image prior-type generative modeling approach and relies on approximate Bayesian inference to regularize the deep convolutional neural network. We demonstrate our approach on several anatomies, contrasts, and sampling patterns and show improved performance over existing approaches in scan-specific calibrationless parallel imaging and compressed sensing.
△ Less
Submitted 12 February, 2024; v1 submitted 1 March, 2022;
originally announced March 2022.
-
Least Squares Optimal Density Compensation for the Gridding Non-uniform Discrete Fourier Transform
Authors:
Nicholas Dwork,
Daniel O'Connor,
Ethan M. I. Johnson,
Corey A. Baron,
Jeremy W. Gordon,
John M. Pauly,
Peder E. Z. Larson
Abstract:
The Gridding algorithm has shown great utility for reconstructing images from non-uniformly spaced samples in the Fourier domain in several imaging modalities. Due to the non-uniform spacing, some correction for the variable density of the samples must be made. Existing methods for generating density compensation values are either sub-optimal or only consider a finite set of points (a set of measu…
▽ More
The Gridding algorithm has shown great utility for reconstructing images from non-uniformly spaced samples in the Fourier domain in several imaging modalities. Due to the non-uniform spacing, some correction for the variable density of the samples must be made. Existing methods for generating density compensation values are either sub-optimal or only consider a finite set of points (a set of measure 0) in the optimization. This manuscript presents the first density compensation algorithm for a general trajectory that takes into account the point spread function over a set of non-zero measure. We show that the images reconstructed with Gridding using the density compensation values of this method are of superior quality when compared to density compensation weights determined in other ways. Results are shown with a numerical phantom and with magnetic resonance images of the abdomen and the knee.
△ Less
Submitted 16 June, 2021; v1 submitted 11 June, 2021;
originally announced June 2021.
-
Anisotropic field-of-views in radial imaging
Authors:
Peder E. Z. Larson,
Paul T. Gurney,
Dwight G. Nishimura
Abstract:
Radial imaging techniques, such as projection-reconstruction (PR), are used in magnetic resonance imaging (MRI) for dynamic imaging, angiography, and short-imaging. They are robust to flow and motion, have diffuse aliasing patterns, and support short readouts and echo times. One drawback is that standard implementations do not support anisotropic field-of-view (FOV) shapes, which are used to match…
▽ More
Radial imaging techniques, such as projection-reconstruction (PR), are used in magnetic resonance imaging (MRI) for dynamic imaging, angiography, and short-imaging. They are robust to flow and motion, have diffuse aliasing patterns, and support short readouts and echo times. One drawback is that standard implementations do not support anisotropic field-of-view (FOV) shapes, which are used to match the imaging parameters to the object or region-of-interest. A set of fast, simple algorithms for 2-D and 3-D PR, and 3-D cones acquisitions are introduced that match the sampling density in frequency space to the desired FOV shape. Tailoring the acquisitions allows for reduction of aliasing artifacts in undersampled applications or scan time reductions without introducing aliasing in fully-sampled applications. It also makes possible new radial imaging applications that were previously unsuitable, such as imaging elongated regions or thin slabs. 2-D PR longitudinal leg images and thin-slab, single breath-hold 3-D PR abdomen images, both with isotropic resolution, demonstrate these new possibilities. No scan time to volume efficiency is lost by using anisotropic FOVs. The acquisition trajectories can be computed on a scan by scan basis.
△ Less
Submitted 12 January, 2021;
originally announced January 2021.
-
A Metabolite Specific 3D Stack-of-Spiral bSSFP Sequence for Improved Lactate Imaging in Hyperpolarized [1-$^{13}$C]Pyruvate Studies on a 3T Clinical Scanner
Authors:
Shuyu Tang,
Robert Bok,
Hecong Qin,
Galen Reed,
Mark VanCriekinge,
Romelyn Delos Santos,
William Overall,
Juan Santos,
Jeremy Gordon,
Zhen Jane Wang,
Daniel B. Vigneron,
Peder E. Z. Larson
Abstract:
Purpose: The balanced steady-state free precession sequence has been previously explored to improve the efficient use of non-recoverable hyperpolarized $^{13}$C magnetization, but suffers from poor spectral selectivity and long acquisition time. The purpose of this study was to develop a novel metabolite-specific 3D bSSFP ("MS-3DSSFP") sequence with stack-of-spiral readouts for improved lactate im…
▽ More
Purpose: The balanced steady-state free precession sequence has been previously explored to improve the efficient use of non-recoverable hyperpolarized $^{13}$C magnetization, but suffers from poor spectral selectivity and long acquisition time. The purpose of this study was to develop a novel metabolite-specific 3D bSSFP ("MS-3DSSFP") sequence with stack-of-spiral readouts for improved lactate imaging in hyperpolarized [1-$^{13}$C]pyruvate studies on a clinical 3T scanner.
Methods: Simulations were performed to evaluate the spectral response of the MS-3DSSFP sequence. Thermal $^{13}$C phantom experiments were performed to validate the MS-3DSSFP sequence. In vivo hyperpolarized [1-$^{13}$C]pyruvate studies were performed to compare the MS-3DSSFP sequence with metabolite specific gradient echo ("MS-GRE") sequences for lactate imaging.
Results: Simulations, phantom and in vivo studies demonstrate that the MS-3DSSFP sequence achieved spectrally selective excitation on lactate while minimally perturbing other metabolites. Compared with MS-GRE sequences, the MS-3DSSFP sequence showed approximately a 2.5-fold SNR improvement for lactate imaging in rat kidneys, prostate tumors in a mouse model and human kidneys.
Conclusions: Improved lactate imaging using the MS-3DSSFP sequence in hyperpolarized [1-$^{13}$C]pyruvate studies was demonstrated in animals and humans. The MS-3DSSFP sequence could be applied for other clinical applications such as in the brain or adapted for imaging other metabolites such as pyruvate and bicarbonate.
△ Less
Submitted 20 August, 2020;
originally announced August 2020.
-
A Regional Bolus Tracking and Real-time B$_1$ Calibration Method for Hyperpolarized $^{13}$C MRI
Authors:
Shuyu Tang,
Eugene Milshteyn,
Galen Reed,
Jeremy Gordon,
Robert Bok,
Xucheng Zhu,
Zihan Zhu,
Daniel B. Vigneron,
Peder E. Z. Larson
Abstract:
Purpose: Acquisition timing and B$_1$ calibration are two key factors that affect the quality and accuracy of hyperpolarized $^{13}$C MRI. The goal of this project was to develop a new approach using regional bolus tracking to trigger Bloch-Siegert B$_1$ map** and real-time B$_1$ calibration based on regional B$_1$ measurements, followed by dynamic imaging of hyperpolarized $^{13}C$ metabolites…
▽ More
Purpose: Acquisition timing and B$_1$ calibration are two key factors that affect the quality and accuracy of hyperpolarized $^{13}$C MRI. The goal of this project was to develop a new approach using regional bolus tracking to trigger Bloch-Siegert B$_1$ map** and real-time B$_1$ calibration based on regional B$_1$ measurements, followed by dynamic imaging of hyperpolarized $^{13}C$ metabolites in vivo.
Methods: The proposed approach was implemented on a system which allows real-time data processing and real-time control on the sequence. Real-time center frequency calibration upon the bolus arrival was also added. The feasibility of applying the proposed framework for in vivo hyperpolarized $^{13}$C imaging was tested on healthy rats, tumor-bearing mice and a healthy volunteer on a clinical 3T scanner following hyperpolarized [1-$^{13}$C]pyruvate injection. Multichannel receive coils were used in the human study.
Results: Automatic acquisition timing based on either regional bolus peak or bolus arrival was achieved with the proposed framework. Reduced blurring artifacts in real-time reconstructed images were observed with real-time center frequency calibration. Real-time computed B$_1$ scaling factors agreed with real-time acquired B$_1$ maps. Flip angle correction using B$_1$ maps results in a more consistent quantification of metabolic activity (i.e, pyruvate-to-lactate conversion, k$_{PL}$). Experiment recordings are provided to demonstrate the real-time actions during the experiment.
Conclusion: The proposed method was successfully demonstrated on animals and a human volunteer, and is anticipated to improve the efficient use of the hyperpolarized signal as well as the accuracy and robustness of hyperpolarized $^{13}$C imaging.
△ Less
Submitted 20 August, 2020;
originally announced August 2020.
-
Attenuation Coefficient Estimation for PET/MRI With Bayesian Deep Learning pseudo-CT and Maximum Likelihood Estimation of Activity and Attenuation
Authors:
Andrew P. Leynes,
Sangtae P. Ahn,
Kristen A. Wangerin,
Sandeep S. Kaushik,
Florian Wiesinger,
Thomas A. Hope,
Peder E. Z. Larson
Abstract:
A major remaining challenge for magnetic resonance-based attenuation correction methods (MRAC) is their susceptibility to sources of MRI artifacts (e.g. implants, motion) and uncertainties due to the limitations of MRI contrast (e.g. accurate bone delineation and density, and separation of air/bone). We propose using a Bayesian deep convolutional neural network that, in addition to generating an i…
▽ More
A major remaining challenge for magnetic resonance-based attenuation correction methods (MRAC) is their susceptibility to sources of MRI artifacts (e.g. implants, motion) and uncertainties due to the limitations of MRI contrast (e.g. accurate bone delineation and density, and separation of air/bone). We propose using a Bayesian deep convolutional neural network that, in addition to generating an initial pseudo-CT from MR data, also produces uncertainty estimates of the pseudo-CT to quantify the limitations of the MR data. These outputs are combined with MLAA reconstruction that uses the PET emission data to improve the attenuation maps. With the proposed approach (UpCT-MLAA), we demonstrate accurate estimation of PET uptake in pelvic lesions and show recovery of metal implants. In patients without implants, UpCT-MLAA had acceptable but slightly higher RMSE than Zero-echo-time and Dixon Deep pseudo-CT when compared to CTAC. In patients with metal implants, MLAA recovered the metal implant; however, anatomy outside the implant region was obscured by noise and crosstalk artifacts. Attenuation coefficients from the pseudo-CT from Dixon MRI were accurate in normal anatomy; however, the metal implant region was estimated to have attenuation coefficients of air. UpCT-MLAA estimated attenuation coefficients of metal implants alongside accurate anatomic depiction outside of implant regions.
△ Less
Submitted 13 October, 2021; v1 submitted 10 January, 2020;
originally announced January 2020.
-
Simultaneous Segmentation and Relaxometry for MRI through Multitask Learning
Authors:
Peng Cao,
**g Liu,
Shuyu Tang,
Andrew Leynes,
Janine M. Lupo,
Duan Xu,
Peder E. Z. Larson
Abstract:
Purpose: This study demonstrated an MR signal multitask learning method for 3D simultaneous segmentation and relaxometry of human brain tissues. Materials and Methods: A 3D inversion-prepared balanced steady-state free precession sequence was used for acquiring in vivo multi-contrast brain images. The deep neural network contained 3 residual blocks, and each block had 8 fully connected layers with…
▽ More
Purpose: This study demonstrated an MR signal multitask learning method for 3D simultaneous segmentation and relaxometry of human brain tissues. Materials and Methods: A 3D inversion-prepared balanced steady-state free precession sequence was used for acquiring in vivo multi-contrast brain images. The deep neural network contained 3 residual blocks, and each block had 8 fully connected layers with sigmoid activation, layer norm, and 256 neurons in each layer. Online synthesized MR signal evolutions and labels were used to train the neural network batch-by-batch. Empirically defined ranges of T1 and T2 values for the normal gray matter, white matter and cerebrospinal fluid (CSF) were used as the prior knowledge. MRI brain experiments were performed on 3 healthy volunteers as well as animal (N=6) and prostate patient (N=1) experiments. Results: In animal validation experiment, the differences/errors (mean difference $\pm$ standard deviation of difference) between the T1 and T2 values estimated from the proposed method and the ground truth were 113 $\pm$ 486 and 154 $\pm$ 512 ms for T1, and 5 $\pm$ 33 and 7 $\pm$ 41 ms for T2, respectively. In healthy volunteer experiments (N=3), whole brain segmentation and relaxometry were finished within ~5 seconds. The estimated apparent T1 and T2 maps were in accordance with known brain anatomy, and not affected by coil sensitivity variation. Gray matter, white matter, and CSF were successfully segmented. The deep neural network can also generate synthetic T1 and T2 weighted images. Conclusion: The proposed multitask learning method can directly generate brain apparent T1 and T2 maps, as well as synthetic T1 and T2 weighted images, in conjunction with segmentation of gray matter, white matter and CSF.
△ Less
Submitted 27 November, 2019;
originally announced November 2019.
-
Bone Material Analogues for PET/MRI Phantoms
Authors:
Dharshan Chandramohan,
Peng Cao,
Misung Han,
Hongyu An,
John J. Sunderland,
Paul E. Kinahan,
Richard Laforest,
Thomas A. Hope,
Peder E. Z. Larson
Abstract:
Purpose: To develop bone material analogues that can be used in construction of phantoms for simultaneous PET/MRI systems.
Methods: Plaster was used as the basis for the bone material analogues tested in this study. It was mixed with varying concentrations of an iodinated CT contrast, a gadolinium-based MR contrast agent, and copper sulfate to modulate the attenuation properties and MRI properti…
▽ More
Purpose: To develop bone material analogues that can be used in construction of phantoms for simultaneous PET/MRI systems.
Methods: Plaster was used as the basis for the bone material analogues tested in this study. It was mixed with varying concentrations of an iodinated CT contrast, a gadolinium-based MR contrast agent, and copper sulfate to modulate the attenuation properties and MRI properties (T1 and T2*). Attenuation was measured with CT and 68Ge transmission scans, and MRI properties were measured with quantitative ultrashort echo time pulse sequences. A proof-of-concept skull was created by plaster casting.
Results: Undoped plaster has a 511 keV attenuation coefficient (~0.14 cm-1) similar to cortical bone (0.10-0.15 cm-1), but slightly longer T1 (~500 ms) and T2* (~1.2 ms) MR parameters compared to bone (T1 ~ 300 ms, T2* ~ 0.4 ms). Do** with the iodinated agent resulted in increased attenuation with minimal perturbation to the MR parameters. Do** with a gadolinium chelate greatly reduced T1 and T2*, resulting in extremely short T1 values when the target T2* values were reached, while the attenuation coefficient was unchanged. Do** with copper sulfate was more selective for T2* shortening and achieved comparable T1 and T2* values to bone (after 1 week of drying), while the attenuation coefficient was unchanged.
Conclusions: Plaster doped with copper sulfate is a promising bone material analogue for a PET/MRI phantom, mimicking the MR properties (T1 and T2*) and 511 keV attenuation coefficient of human cortical bone.
△ Less
Submitted 14 March, 2020; v1 submitted 24 October, 2019;
originally announced October 2019.
-
Extreme MRI: Large-Scale Volumetric Dynamic Imaging from Continuous Non-Gated Acquisitions
Authors:
Frank Ong,
Xucheng Zhu,
Joseph Y. Cheng,
Kevin M. Johnson,
Peder E. Z. Larson,
Shreyas S. Vasanawala,
Michael Lustig
Abstract:
Purpose: To develop a framework to reconstruct large-scale volumetric dynamic MRI from rapid continuous and non-gated acquisitions, with applications to pulmonary and dynamic contrast enhanced (DCE) imaging.
Theory and Methods: The problem considered here requires recovering hundred-gigabytes of dynamic volumetric image data from a few gigabytes of k-space data, acquired continuously over severa…
▽ More
Purpose: To develop a framework to reconstruct large-scale volumetric dynamic MRI from rapid continuous and non-gated acquisitions, with applications to pulmonary and dynamic contrast enhanced (DCE) imaging.
Theory and Methods: The problem considered here requires recovering hundred-gigabytes of dynamic volumetric image data from a few gigabytes of k-space data, acquired continuously over several minutes. This reconstruction is vastly under-determined, heavily stressing computing resources as well as memory management and storage. To overcome these challenges, we leverage intrinsic three dimensional (3D) trajectories, such as 3D radial and 3D cones, with ordering that incoherently cover time and k-space over the entire acquisition. We then propose two innovations: (1) A compressed representation using multi-scale low rank matrix factorization that constrains the reconstruction problem, and reduces its memory footprint. (2) Stochastic optimization to reduce computation, improve memory locality, and minimize communications between threads and processors. We demonstrate the feasibility of the proposed method on DCE imaging acquired with a golden-angle ordered 3D cones trajectory and pulmonary imaging acquired with a bit-reversed ordered 3D radial trajectory. We compare it with "soft-gated" dynamic reconstruction for DCE and respiratory resolved reconstruction for pulmonary imaging.
Results: The proposed technique shows transient dynamics that are not seen in gating based methods. When applied to datasets with irregular, or non-repetitive motions, the proposed method displays sharper image features.
Conclusion: We demonstrated a method that can reconstruct massive 3D dynamic image series in the extreme undersampling and extreme computation setting.
△ Less
Submitted 5 February, 2020; v1 submitted 30 September, 2019;
originally announced September 2019.
-
Imaging Renal Urea Handling in Rats at Millimeter Resolution using Hyperpolarized Magnetic Resonance Relaxometry
Authors:
Galen D. Reed,
Cornelius von Morze,
Alan S. Verkman,
Bertram L. Koelsch,
Myriam M. Chaumeil,
Michael Lustig,
Sabrina M. Ronen,
Jeff M. Sands,
Peder E. Z. Larson,
Zhen J. Wang,
Jan Henrik Ardenkjær Larsen,
John Kurhanewicz,
Daniel B. Vigneron
Abstract:
\textit{In vivo} spin spin relaxation time ($T_2$) heterogeneity of hyperpolarized \textsuperscript{13}C urea in the rat kidney was investigated. Selective quenching of the vascular hyperpolarized \textsuperscript{13}C signal with a macromolecular relaxation agent revealed that a long-$T_2$ component of the \textsuperscript{13}C urea signal originated from the renal extravascular space, thus allow…
▽ More
\textit{In vivo} spin spin relaxation time ($T_2$) heterogeneity of hyperpolarized \textsuperscript{13}C urea in the rat kidney was investigated. Selective quenching of the vascular hyperpolarized \textsuperscript{13}C signal with a macromolecular relaxation agent revealed that a long-$T_2$ component of the \textsuperscript{13}C urea signal originated from the renal extravascular space, thus allowing the vascular and renal filtrate contrast agent pools of the \textsuperscript{13}C urea to be distinguished via multi-exponential analysis. The $T_2$ response to induced diuresis and antidiuresis was performed with two imaging agents: hyperpolarized \textsuperscript{13}C urea and a control agent hyperpolarized bis-1,1-(hydroxymethyl)-1-\textsuperscript{13}C-cyclopropane-$^2\textrm{H}_8$. Large $T_2$ increases in the inner-medullar and papilla were observed with the former agent and not the latter during antidiuresis suggesting that $T_2$ relaxometry may be used to monitor the inner-medullary urea transporter (UT)-A1 and UT-A3 mediated urea concentrating process. Two high resolution imaging techniques - multiple echo time averaging and ultra-long echo time sub-2 mm$^3$ resolution 3D imaging - were developed to exploit the particularly long relaxation times observed.
△ Less
Submitted 2 November, 2015; v1 submitted 31 October, 2015;
originally announced November 2015.