-
Enhancing Membrane-Based Scanning Force Microscopy Through an Optical Cavity
Authors:
Thomas Gisler,
David Hälg,
Vincent Dumont,
Shobhna Misra,
Letizia Catalini,
Eric C. Langman,
Albert Schliesser,
Christian L. Degen,
Alexander Eichler
Abstract:
The new generation of strained silicon nitride resonators harbors great promise for scanning force microscopy, especially when combined with the extensive toolbox of cavity optomechanics. However, accessing a mechanical resonator inside an optical cavity with a scanning tip is challenging. Here, we experimentally demonstrate a cavity-based scanning force microscope based on a silicon nitride membr…
▽ More
The new generation of strained silicon nitride resonators harbors great promise for scanning force microscopy, especially when combined with the extensive toolbox of cavity optomechanics. However, accessing a mechanical resonator inside an optical cavity with a scanning tip is challenging. Here, we experimentally demonstrate a cavity-based scanning force microscope based on a silicon nitride membrane sensor. We overcome geometric constraints by making use of the extended nature of the mechanical resonator normal modes, which allows us to spatially separate the scanning and readout sites of the membrane. Our microscope is geared towards low-temperature applications in the zeptonewton regime, such as nanoscale nuclear spin detection and imaging.
△ Less
Submitted 11 June, 2024;
originally announced June 2024.
-
Membrane-in-the-middle optomechanics with a soft-clamped membrane at milliKelvin temperatures
Authors:
Eric Planz,
Xiang Xi,
Thibault Capelle,
Eric C. Langman,
Albert Schliesser
Abstract:
Soft-clamped silicon nitride membrane resonators reach coherence times tau in excess of 100 ms at milliKelvin bath temperatures. However, harnessing strong optomechanical coupling in dry dilution refrigerators remains challenging due to vibration issues and heating by optical absorption. Here, we propose to address these issues with an actuator-free optical cavity and mechanical resonator design,…
▽ More
Soft-clamped silicon nitride membrane resonators reach coherence times tau in excess of 100 ms at milliKelvin bath temperatures. However, harnessing strong optomechanical coupling in dry dilution refrigerators remains challenging due to vibration issues and heating by optical absorption. Here, we propose to address these issues with an actuator-free optical cavity and mechanical resonator design, in which the cavity is mounted on a simple vibration-isolation platform. We observe dynamical backaction when the cavity is driven with a free-space optical beam stabilized close to the red sideband using a two-beam locking scheme. Finally, we characterize the effect of absorption heating on the coherence time, and find a scaling with the intracavity power P as tau proportional to P to the power of -(0.34+/-0.04).
△ Less
Submitted 10 October, 2023; v1 submitted 1 August, 2023;
originally announced August 2023.
-
Laser cooling a membrane-in-the-middle system close to the quantum ground state from room temperature
Authors:
Sampo A. Saarinen,
Nenad Kralj,
Eric C. Langman,
Yeghishe Tsaturyan,
Albert Schliesser
Abstract:
Many protocols in quantum science and technology require initializing a system in a pure quantum state. In the context of the motional state of massive resonators, this enables studying fundamental physics at the elusive quantum-classical transition, and measuring force and acceleration with enhanced sensitivity. Laser cooling has been a method of choice to prepare mechanical resonators in the qua…
▽ More
Many protocols in quantum science and technology require initializing a system in a pure quantum state. In the context of the motional state of massive resonators, this enables studying fundamental physics at the elusive quantum-classical transition, and measuring force and acceleration with enhanced sensitivity. Laser cooling has been a method of choice to prepare mechanical resonators in the quantum ground state, one of the simplest pure states. However, in order to overcome the heating and decoherence by the thermal bath, this usually has to be combined with cryogenic cooling. Here, we laser-cool an ultracoherent, soft-clamped mechanical resonator close to the quantum ground state directly from room temperature. To this end, we implement the versatile membrane-in-the-middle setup with one fiber mirror and one phononic crystal mirror, which reaches a quantum cooperativity close to unity already at room temperature. We furthermore introduce a powerful combination of coherent and measurement-based quantum control techniques, which allows us to mitigate thermal intermodulation noise. The lowest occupancy we reach is 30 phonons, limited by measurement imprecision. Doing away with the necessity for cryogenic cooling should further facilitate the spread of optomechanical quantum technologies.
△ Less
Submitted 30 January, 2023; v1 submitted 22 June, 2022;
originally announced June 2022.
-
Strong parametric coupling between two ultra-coherent membrane modes
Authors:
David Hälg,
Thomas Gisler,
Eric C. Langman,
Shobhna Misra,
Oded Zilberberg,
Albert Schliesser,
Christian L. Degen,
Alexander Eichler
Abstract:
We demonstrate parametric coupling between two modes of a silicon nitride membrane. We achieve the coupling by applying an oscillating voltage to a sharp metal tip that approaches the membrane surface to within a few 100 nm. When the voltage oscillation frequency is equal to the mode frequency difference, the modes exchange energy periodically and much faster than their free energy decay rate. Thi…
▽ More
We demonstrate parametric coupling between two modes of a silicon nitride membrane. We achieve the coupling by applying an oscillating voltage to a sharp metal tip that approaches the membrane surface to within a few 100 nm. When the voltage oscillation frequency is equal to the mode frequency difference, the modes exchange energy periodically and much faster than their free energy decay rate. This flexible method can potentially be useful for rapid state control and transfer between modes, and is an important step towards parametric spin sensing experiments with membrane resonators.
△ Less
Submitted 24 September, 2021;
originally announced September 2021.
-
Modelling and observation of nonlinear dam** in dissipation-diluted nanomechanical resonators
Authors:
Letizia Catalini,
Massimiliano Rossi,
Eric C. Langman,
Albert Schliesser
Abstract:
Dissipation dilution enables extremely low linear loss in stressed, high-aspect ratio nanomechanical resonators, such as strings or membranes. Here, we report on the observation and theoretical modelling of nonlinear dissipation in such structures. We introduce an analytical model based on von Kármán theory, which can be numerically evaluated using finite-element models for arbitrary geometries. W…
▽ More
Dissipation dilution enables extremely low linear loss in stressed, high-aspect ratio nanomechanical resonators, such as strings or membranes. Here, we report on the observation and theoretical modelling of nonlinear dissipation in such structures. We introduce an analytical model based on von Kármán theory, which can be numerically evaluated using finite-element models for arbitrary geometries. We use this approach to predict nonlinear loss and (Duffing) frequency shift in ultracoherent phononic membrane resonators. A set of systematic measurements with silicon nitride membranes shows good agreement with the model for low-order soft-clamped modes. Our analysis also reveals quantitative connections between these nonlinearities and dissipation dilution. This is of interest for future device design, and can provide important insight when diagnosing the performance of dissipation dilution in an experimental setting.
△ Less
Submitted 23 April, 2021; v1 submitted 22 December, 2020;
originally announced December 2020.
-
Membrane-based scanning force microscopy
Authors:
David Hälg,
Thomas Gisler,
Yeghishe Tsaturyan,
Letizia Catalini,
Urs Grob,
Marc-Dominik Krass,
Martin Héritier,
Hinrich Mattiat,
Ann-Katrin Thamm,
Romana Schirhagl,
Eric C. Langman,
Albert Schliesser,
Christian L. Degen,
Alexander Eichler
Abstract:
We report the development of a scanning force microscope based on an ultra-sensitive silicon nitride membrane transducer. Our development is made possible by inverting the standard microscope geometry - in our instrument, the substrate is vibrating and the scanning tip is at rest. We present first topography images of samples placed on the membrane surface. Our measurements demonstrate that the me…
▽ More
We report the development of a scanning force microscope based on an ultra-sensitive silicon nitride membrane transducer. Our development is made possible by inverting the standard microscope geometry - in our instrument, the substrate is vibrating and the scanning tip is at rest. We present first topography images of samples placed on the membrane surface. Our measurements demonstrate that the membrane retains an excellent force sensitivity when loaded with samples and in the presence of a scanning tip. We discuss the prospects and limitations of our instrument as a quantum-limited force sensor and imaging tool.
△ Less
Submitted 11 June, 2020;
originally announced June 2020.