-
TREX-DM: a low background Micromegas-based TPC for low-mass WIMP detection
Authors:
F. J. Iguaz,
J. G. Garza,
F. Aznar,
J. F. Castel,
S. Cebrian,
T. Dafni,
J. A. Garcia,
I. G. Irastorza,
A. Lagraba,
G. Luzon,
A. Peiro
Abstract:
Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background Micromegas-based TPC for low-mass WIMP detection. Its main goal is the operation of an active detection mass $\sim$0.3 kg, with an energy threshold below 0.4 keVee and ful…
▽ More
Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background Micromegas-based TPC for low-mass WIMP detection. Its main goal is the operation of an active detection mass $\sim$0.3 kg, with an energy threshold below 0.4 keVee and fully built with previously selected radiopure materials. This work describes the commissioning of the actual setup situated in a laboratory on surface and the updates needed for a possible physics run at the Canfranc Underground Laboratory (LSC) in 2016. A preliminary background model of TREX-DM is also presented, based on a Geant4 simulation, the simulation of the detector's response and two discrimination methods: a conservative muon/electron and one based on a neutron source. Based on this background model, TREX-DM could be competitive in the search for low-mass WIMPs. In particular it could be sensitive, e.g., to the low-mass WIMP interpretation of the DAMA/LIBRA and other hints in a conservative scenario.
△ Less
Submitted 7 January, 2016;
originally announced January 2016.
-
TREX-DM: a low-background Micromegas-based TPC for low-mass WIMP detection
Authors:
F. J. Iguaz,
J. G. Garza,
F. Aznar,
J. F. Castel,
S. Cebrián,
T. Dafni,
J. A. García,
I. G. Irastorza,
A. Lagraba,
G. Luzón,
A. Peiró
Abstract:
If Dark Matter is made of Weakly Interacting Massive Particles (WIMPs) with masses below $\sim$20 GeV, the corresponding nuclear recoils in mainstream WIMP experiments are of energies too close, or below, the experimental threshold. Gas Time Projection Chambers (TPCs) can be operated with a variety of target elements, offer good tracking capabilities and, on account of the amplification in gas, ve…
▽ More
If Dark Matter is made of Weakly Interacting Massive Particles (WIMPs) with masses below $\sim$20 GeV, the corresponding nuclear recoils in mainstream WIMP experiments are of energies too close, or below, the experimental threshold. Gas Time Projection Chambers (TPCs) can be operated with a variety of target elements, offer good tracking capabilities and, on account of the amplification in gas, very low thresholds are achievable. Recent advances in electronics and in novel radiopure TPC readouts, especially micro-mesh gas structure (Micromegas), are improving the scalability and low-background prospects of gaseous TPCs. Here we present TREX-DM, a prototype to test the concept of a Micromegas-based TPC to search for low-mass WIMPs. The detector is designed to host an active mass of $\sim$0.300 kg of Ar at 10 bar, or alternatively $\sim$0.160 kg of Ne at 10 bar, with an energy threshold below 0.4 keVee, and is fully built with radiopure materials. We will describe the detector in detail, the results from the commissioning phase on surface, as well as a preliminary background model. The anticipated sensitivity of this technique may go beyond current experimental limits for WIMPs of masses of 2-8 GeV.
△ Less
Submitted 8 August, 2016; v1 submitted 4 December, 2015;
originally announced December 2015.
-
Comissioning of TREX-DM, a low background Micromegas-based Time Projection Chamber for low mass WIMP detection
Authors:
F. J. Iguaz,
J. G. Garza,
F. Aznar,
J. F. Castel,
S. Cebrian,
T. Dafni,
J. A. Garcia,
I. G. Irastorza,
A. Lagraba,
G. Luzon,
A. Peiro
Abstract:
Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background Micromegas-based Time Projection Chamber for low-mass WIMP detection. Its main goal is the operation of an active detection mass $\sim$0.3 kg, with an energy threshold bel…
▽ More
Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background Micromegas-based Time Projection Chamber for low-mass WIMP detection. Its main goal is the operation of an active detection mass $\sim$0.3 kg, with an energy threshold below 0.4~keVee and fully built with previously selected radiopure materials. This work focuses on the commissioning of the actual setup situated in a laboratory on surface. A preliminary background model of the experiment is also presented, based on Geant4 simulations and two discrimination methods: a conservative muon/electron and one based on a $^{252}$Cf source. Based on this model, TREX-DM could be competitive in the search for low mass WIMPs and, in particular, it could be sensitive to the WIMP interpretation of the DAMA/LIBRA hint.
△ Less
Submitted 7 September, 2015;
originally announced September 2015.
-
Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres
Authors:
Diego Gonzalez-Diaz,
V. Alvarez,
F. I. G. Borges,
M. Camargo,
S. Carcel,
S. Cebrian,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Diaz,
R. Esteve,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
J. J. Gomez-Cadenas,
R. M. Gutierrez,
J. Hauptman,
J. A. Hernando Morata,
D. C. Herrera,
I. G. Irastorza,
L. Labarga,
A. Laing
, et al. (58 additional authors not shown)
Abstract:
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +-0.13 mm-sigma (longitudinal)…
▽ More
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +-0.13 mm-sigma (longitudinal), 0.8 +-0.15 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent mixture. The TPC, that houses 1.1 kg of gas in its active volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8mm x 8mm x 1.2mm for approximately 10 cm/MeV-long electron tracks. This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the 0bbnu decay in 136Xe, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks.
△ Less
Submitted 17 June, 2015; v1 submitted 14 April, 2015;
originally announced April 2015.
-
Lessons from the operation of the "Penning-Fluorescent" TPC and prospects
Authors:
Diego Gonzalez-Diaz,
F. Aznar,
J. Castel,
S. Cebrian,
T. Dafni,
J. A. Garcia,
J. G. Garza,
H. Gomez,
D. C. Herrera,
F. J. Iguaz,
I. G. Irastorza,
A. Lagraba,
G. Luzon,
A. Rodriguez,
E. Ruiz-Choliz,
L. Segui,
A. Tomas E. Ferrer-Ribas,
I. Giomataris
Abstract:
We have recently reported the development of a new type of high-pressure Xenon time projection chamber operated with an ultra-low diffusion mixture and that simultaneously displays Penning effect and fluorescence in the near-visible region (300 nm). The concept, dubbed `Penning-Fluorescent' TPC, allows the simultaneous reconstruction of primary charge and scintillation with high topological and ca…
▽ More
We have recently reported the development of a new type of high-pressure Xenon time projection chamber operated with an ultra-low diffusion mixture and that simultaneously displays Penning effect and fluorescence in the near-visible region (300 nm). The concept, dubbed `Penning-Fluorescent' TPC, allows the simultaneous reconstruction of primary charge and scintillation with high topological and calorimetric fidelity.
△ Less
Submitted 15 May, 2015; v1 submitted 14 April, 2015;
originally announced April 2015.
-
TREX-DM: a low background Micromegas-based TPC for low mass WIMP detection
Authors:
F. J. Iguaz,
J. G. Garza,
F. Aznar,
J. F. Castel,
S. Cebrian,
T. Dafni,
J. A. Garcia,
H. Gomez,
D. Gonzalez-Diaz,
I. G. Irastorza,
A. Lagraba,
G. Luzon,
A. Peiro,
A. Rodriguez
Abstract:
Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we present the TREX-DM experiment, a low background Micromegas-based TPC for low-mass WIMP detection. Its main goal is the operation of an active detection mass $\sim$0.300 kg, with an energy threshold below 0.4 keVee and fu…
▽ More
Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we present the TREX-DM experiment, a low background Micromegas-based TPC for low-mass WIMP detection. Its main goal is the operation of an active detection mass $\sim$0.300 kg, with an energy threshold below 0.4 keVee and fully built with previously selected radiopure materials. This article describes the actual setup, the first results of the comissioning in Ar+2\%iC$_4$H$_{10}$ at 1.2 bar and the future updates for a possible physics run at the Canfranc Underground Laboratory in 2016. A first background model is also presented, based on Geant4 simulations and a muon/electron discrimination method. In a conservative scenario, TREX-DM could be sensitive to DAMA/LIBRA and other hints of positive WIMPs signals, with some space for improvement with a neutron/electron discrimination method or the use of other light gases.
△ Less
Submitted 24 March, 2015;
originally announced March 2015.