-
Practical Approach to Extending Baselines of Telescopes using Continuous-Variable Quantum Information
Authors:
Bran Purvis,
Randy Lafler,
R. Nicholas Lanning
Abstract:
Interferometric telescopes are instrumental for the imaging of distant astronomical bodies, but optical loss heavily restricts how far telescopes in an array can be placed from one another, leading to a bottleneck in the resolution that can be achieved. An entanglement-assisted approach to this problem has been proposed by Gottesman, Jennewein, and Croke (GJC12) [Physical Review Letters, 109(7):07…
▽ More
Interferometric telescopes are instrumental for the imaging of distant astronomical bodies, but optical loss heavily restricts how far telescopes in an array can be placed from one another, leading to a bottleneck in the resolution that can be achieved. An entanglement-assisted approach to this problem has been proposed by Gottesman, Jennewein, and Croke (GJC12) [Physical Review Letters, 109(7):070503, July 2011], as a possible solution to the issue of optical loss if the entangled state can be distributed across long distances by employing a quantum repeater network. In this paper, we propose an alternative entanglement-assisted scheme that interferes a two-mode squeezed vacuum state with the astronomical state and then measures the resulting state by means of homodyne detection. We use a continuous-variable approach and compute the Fisher information with respect to the mutual coherence of the astronomical source. We show that when the Fisher information is observed cumulatively at the rate at which successful measurements can be performed, our proposed scheme does not outperforms the traditional direct detection approach or the entanglement-assisted approach of GJC12.
△ Less
Submitted 6 March, 2024;
originally announced March 2024.
-
Quantum time transfer: a practical method for lossy and noisy channels
Authors:
Randy Lafler,
R. Nicholas Lanning
Abstract:
Timing requirements for long-range quantum networking are driven by the necessity of synchronizing the arrival of photons, from independent sources, for Bell-state measurements. Thus, characteristics such as repetition rate and pulse duration influence the precision required to enable quantum networking tasks such as teleportation and entanglement swap**. Some solutions have been proposed utiliz…
▽ More
Timing requirements for long-range quantum networking are driven by the necessity of synchronizing the arrival of photons, from independent sources, for Bell-state measurements. Thus, characteristics such as repetition rate and pulse duration influence the precision required to enable quantum networking tasks such as teleportation and entanglement swap**. Some solutions have been proposed utilizing classical laser pulses, frequency combs, and biphoton sources. In this article, we explore the utility of the latter method since it is based upon quantum phenomena, which makes it naturally covert, and potentially quantum secure. Furthermore, it can utilize relatively low performance quantum-photon sources and detection equipment, but provides picosecond-level timing precision even under high loss and high noise channel conditions representative of daytime space-Earth links. Therefore, this method is relevant for daytime space-Earth quantum networking and/or providing high-precision secure timing in GPS denied environments.
△ Less
Submitted 29 June, 2023; v1 submitted 1 November, 2022;
originally announced November 2022.
-
An Optimal Polarization-Entanglement Source: Frequency-Converted SPDC with Degeneracy, Indistinguishability, and Ultra-High Purity Configurable Over a Large Spectral Range
Authors:
Randy Lafler,
R. Nicholas Lanning
Abstract:
Modeling and simulations of entanglement-based quantum-networking protocols commonly assume perfect entangled states. Some investigations have been performed which show how imperfections cause the efficiency of the protocols to rapidly deteriorate. For polarization-entangled states created by SPDC, the fundamentals of phase matching lead to a trade-off problem for the optimal properties of the sta…
▽ More
Modeling and simulations of entanglement-based quantum-networking protocols commonly assume perfect entangled states. Some investigations have been performed which show how imperfections cause the efficiency of the protocols to rapidly deteriorate. For polarization-entangled states created by SPDC, the fundamentals of phase matching lead to a trade-off problem for the optimal properties of the state. We present a new SPDC method which circumvents the trade-off problem and allows one to obtain degeneracy, indistinguishability, and heralded-single-photon spectral purity greater than 99% for any target SPDC wavelength in the visible and NIR spectrum. Therefore, our method can in principle generate optimal polarization-entangled states for polarization-entanglement-based quantum-networking protocols.
△ Less
Submitted 24 June, 2022; v1 submitted 16 July, 2021;
originally announced July 2021.
-
Measurement of directional range components of nuclear recoil tracks in a fiducialised dark matter detector
Authors:
J. B. R. Battat,
E. J. Daw,
A. C. Ezeribe,
J. -L. Gauvreau,
J. L. Harton,
R. Lafler,
E. R. Lee,
D. Loomba,
W. Lynch,
E. H. Miller,
F. Mouton,
S. Paling,
N. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. G. Schuckman II,
D. P. Snowden-Ifft,
N. J. C. Spooner
Abstract:
We present results from the first measurement of axial range components of fiducialized neutron induced nuclear recoil tracks using the DRIFT directional dark matter detector. Nuclear recoil events are fiducialized in the DRIFT experiment using temporal charge carrier separations between different species of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this measurement, neutron-i…
▽ More
We present results from the first measurement of axial range components of fiducialized neutron induced nuclear recoil tracks using the DRIFT directional dark matter detector. Nuclear recoil events are fiducialized in the DRIFT experiment using temporal charge carrier separations between different species of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this measurement, neutron-induced nuclear recoil tracks were generated by exposing the detector to $^{252}$Cf source from different directions. Using these events, the sensitivity of the detector to the expected axial directional signatures were investigated as the neutron source was moved from one detector axis to another. Results obtained from these measurements show clear sensitivity of the DRIFT detector to the axial directional signatures in this fiducialization gas mode.
△ Less
Submitted 28 July, 2017;
originally announced July 2017.
-
Low Threshold Results and Limits from the DRIFT Directional Dark Matter Detector
Authors:
J. B. R. Battat,
A. C. Ezeribe,
J. -L. Gauvreau,
J. L. Harton,
R. Lafler,
E. Law,
E. R. Lee,
D. Loomba,
A. Lumnah,
E. H. Miller,
A. Monte,
F. Mouton,
S. M. Paling,
N. S. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. G. Schuckman II,
D. P. Snowden-Ifft,
N. J. C. Spooner,
N. Waldram
Abstract:
We present results from a 54.7 live-day shielded run of the DRIFT-IId detector, the world's most sensitive, directional, dark matter detector. Several improvements were made relative to our previous work including a lower threshold for detection, a more robust analysis and a tenfold improvement in our gamma rejection factor. After analysis, no events remain in our fiducial region leading to an exc…
▽ More
We present results from a 54.7 live-day shielded run of the DRIFT-IId detector, the world's most sensitive, directional, dark matter detector. Several improvements were made relative to our previous work including a lower threshold for detection, a more robust analysis and a tenfold improvement in our gamma rejection factor. After analysis, no events remain in our fiducial region leading to an exclusion curve for spin-dependent WIMP-proton interactions which reaches 0.28 pb at 100 GeV/c^2 a fourfold improvement on our previous work. We also present results from a 45.4 live-day unshielded run of the DRIFT-IId detector during which 14 nuclear recoil-like events were observed. We demonstrate that the observed nuclear recoil rate of 0.31+/-0.08 events per day is consistent with detection of ambient, fast neutrons emanating from the walls of the Boulby Underground Science Facility.
△ Less
Submitted 27 March, 2017; v1 submitted 31 December, 2016;
originally announced January 2017.
-
The novel properties of SF$_6$ for directional dark matter experiments
Authors:
N. S. Phan,
R. Lafler,
R. J. Lauer,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller
Abstract:
SF$_{6}$ is an inert and electronegative gas that has a long history of use in high voltage insulation and numerous other industrial applications. Although SF$_{6}$ is used as a trace component to introduce stability in tracking chambers, its highly electronegative properties have limited its use in tracking detectors. In this work we present a series of measurements with SF$_{6}$ as the primary g…
▽ More
SF$_{6}$ is an inert and electronegative gas that has a long history of use in high voltage insulation and numerous other industrial applications. Although SF$_{6}$ is used as a trace component to introduce stability in tracking chambers, its highly electronegative properties have limited its use in tracking detectors. In this work we present a series of measurements with SF$_{6}$ as the primary gas in a low pressure Time Projection Chamber (TPC), with a thick GEM used as the avalanche and readout device. The first results of an $^{55}$Fe energy spectrum in SF$_{6}$ are presented. Measurements of the mobility and longitudinal diffusion confirm the negative ion drift of SF$_{6}$. However, the observed waveforms have a peculiar but interesting structure that indicates multiple drift species and a dependence on the reduced field ($E/p$), as well as on the level of water vapor contamination. The discovery of a distinct secondary peak in the waveform, together with its identification and use for fiducializing events in the TPC, are also presented. Our measurements demonstrate that SF$_{6}$ is an ideal gas for directional dark matter detection. In particular, the high fluorine content is desirable for spin-dependent sensitivity, negative ion drift ensures low diffusion over large drift distances, and the multiple species of charge carriers allow for full detector fiducialization.
△ Less
Submitted 20 December, 2016; v1 submitted 16 September, 2016;
originally announced September 2016.
-
First measurement of nuclear recoil head-tail sense in a fiducialised WIMP dark matter detector
Authors:
J. B. R. Battat,
E. Daw,
A. C. Ezeribe,
J. -L. Gauvreau,
J. L. Harton,
R. Lafler,
E. R. Lee,
D. Loomba,
A. Lumnah,
E. H. Miller,
F. Mouton,
A. StJ. Murphy,
S. M. Paling,
N. S. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. G. Schuckman II,
D. P. Snowden-Ifft,
N. J. C. Spooner
Abstract:
Recent computational results suggest that directional dark matter detectors have potential to probe for WIMP dark matter particles below the neutrino floor. The DRIFT-IId detector used in this work is a leading directional WIMP search time projection chamber detector. We report the first measurements of the detection of the directional nuclear recoils in a fully fiducialised low-pressure time proj…
▽ More
Recent computational results suggest that directional dark matter detectors have potential to probe for WIMP dark matter particles below the neutrino floor. The DRIFT-IId detector used in this work is a leading directional WIMP search time projection chamber detector. We report the first measurements of the detection of the directional nuclear recoils in a fully fiducialised low-pressure time projection chamber. In this new operational mode, the distance between each event vertex and the readout plane is determined by the measurement of minority carriers produced by adding a small amount of oxygen to the nominal CS$_{2}$ + CF$_{4}$ target gas mixture. The CS$_2$ + CF$_4$ + O$_2$ mixture has been shown to enable background-free operation at current sensitivities. Sulfur, fluorine, and carbon recoils were generated using neutrons emitted from a $^{252}$Cf source positioned at different locations around the detector. Measurement of the relative energy loss along the recoil tracks allowed the track vector sense, or the so-called head-tail asymmetry parameter, to be deduced. Results show that the previously reported observation of head-tail sensitivity in pure CS$_{2}$ is well retained after the addition of oxygen to the gas mixture.
△ Less
Submitted 24 November, 2016; v1 submitted 16 June, 2016;
originally announced June 2016.
-
Reducing DRIFT Backgrounds with a Submicron Aluminized-Mylar Cathode
Authors:
James B. R. Battat,
Ed Daw,
Alexei Dorofeev,
Anthony C. Ezeribe,
Jennifer R. Fox,
Jean-Luc Gauvreau,
Michael Gold,
Lydia Harmon,
John Harton,
Randy Lafler,
Robert J. Lauer,
Eric R. Lee,
Dinesh Loomba,
Alexander Lumnah,
John Matthews,
Eric H. Miller,
Frederic Mouton,
Alexander St. J. Murphy,
Nguyen Phan,
Stephen W. Sadler,
Andrew Scarff,
Fred Schuckman II,
Daniel Snowden-Ifft,
Neil J. C. Spooner,
Daniel Walker
Abstract:
Background events in the DRIFT-IId dark matter detector, mimicking potential WIMP signals, are predominantly caused by alpha decays on the central cathode in which the alpha particle is completely or partially absorbed by the cathode material. We installed a 0.9 micron thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of ca…
▽ More
Background events in the DRIFT-IId dark matter detector, mimicking potential WIMP signals, are predominantly caused by alpha decays on the central cathode in which the alpha particle is completely or partially absorbed by the cathode material. We installed a 0.9 micron thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of cathode (wire, thin-film, and radiologically clean thin-film) with a focus on the ratio of background events to alpha decays. Two independent methods of measuring the absolute alpha decay rate are used to ensure an accurate result, and agree to within $10\%$. Using alpha range spectroscopy, we measure the radiologically cleanest cathode version to have a contamination of $3.3\pm0.1$ ppt $^{234}$U and $73\pm2$ ppb $^{238}$U. This cathode reduces the probability of producing an RPR from an alpha decay by a factor of $70\pm20$ compared to the original stainless steel wire cathode. First results are presented from a texturized version of the cathode, intended to be even more transparent to alpha particles. These efforts, along with other background reduction measures, have resulted in a drop in the observed background rate from 500/day to 1/day. With the recent implementation of full-volume fiducialization, these remaining background events are identified, allowing for background-free operation.
△ Less
Submitted 1 May, 2015; v1 submitted 11 February, 2015;
originally announced February 2015.
-
Background Assay and Rejection in DRIFT
Authors:
Jeff Brack,
Ed Daw,
Alexei Dorofeev,
Anthony Ezeribe,
Jean-Luc Gauvreau,
Michael Gold,
John Harton,
Randy Lafler,
Robert Lauer,
Eric R. Lee,
Dinesh Loomba,
John Matthews,
Eric H. Miller,
Alissa Monte,
Alex Murphy,
Sean Paling,
Nguyen Phan,
Steve Sadler,
Andrew Scarff,
Daniel Snowden-Ifft,
Neil Spooner,
Sam Telfer,
Daniel Walker,
Matt Williams,
Leonid Yuriev
Abstract:
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with directional sensitivity to WIMP-induced nuclear recoils. Its primary backgrounds were due to alpha decays from contamination on the central cathode. Efforts to reduce these backgrounds led to replacing the 20 μm wire central cathode with one constructed from 0.9 μm aluminized mylar, which is almost totally transparent to alp…
▽ More
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with directional sensitivity to WIMP-induced nuclear recoils. Its primary backgrounds were due to alpha decays from contamination on the central cathode. Efforts to reduce these backgrounds led to replacing the 20 μm wire central cathode with one constructed from 0.9 μm aluminized mylar, which is almost totally transparent to alpha particles. Detailed modeling of the nature and origin of the remaining backgrounds led to an in-situ, ppt-sensitive assay of alpha decay backgrounds from the central cathode. This led to further improvements in the thin-film cathode resulting in over 2 orders of magnitude reduction in backgrounds compared to the wire cathode. Finally, the addition of O$_2$ to CS$_2$ gas was found to produce multiple species of electronegative charge carriers, providing a method to determine the absolute position of nuclear recoils and reject all known remaining backgrounds while retaining a high efficiency for nuclear recoil detection.
△ Less
Submitted 8 April, 2014;
originally announced April 2014.
-
Long-term study of backgrounds in the DRIFT-II directional dark matter experiment
Authors:
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. R. Fox,
J. -L. Gauvreau,
M. Gold,
L. J. Harmon,
J. Harton,
R. Lafler,
J. M. Landers,
R. Lauer,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Pipe,
M. Robinson,
S. Sadler,
A. Scarff,
D. P. Snowden-Ifft
, et al. (4 additional authors not shown)
Abstract:
Low-pressure gas Time Projection Chambers being developed for directional dark matter searches offer a technology with strong particle identification capability combined with the potential to produce a definitive detection of Galactic Weakly Interacting Massive Particle (WIMP) dark matter. A source of events able to mimic genuine WIMP-induced nuclear recoil tracks arises in such experiments from t…
▽ More
Low-pressure gas Time Projection Chambers being developed for directional dark matter searches offer a technology with strong particle identification capability combined with the potential to produce a definitive detection of Galactic Weakly Interacting Massive Particle (WIMP) dark matter. A source of events able to mimic genuine WIMP-induced nuclear recoil tracks arises in such experiments from the decay of radon gas inside the vacuum vessel. The recoils that result from associated daughter nuclei are termed Radon Progeny Recoils (RPRs). We present here experimental data from a long-term study using the DRIFT-II directional dark matter experiment at the Boulby Underground Laboratory of the RPRs, and other backgrounds that are revealed by relaxing the normal cuts that are applied to WIMP search data. By detailed examination of event classes in both spatial and time coordinates using 5.5 years of data, we demonstrate the ability to determine the origin of 4 specific background populations and describe development of new technology and mitigation strategies to suppress them.
△ Less
Submitted 12 May, 2014; v1 submitted 21 July, 2013;
originally announced July 2013.
-
OpenSQUID: a flexible open-source software framework for the control of SQUID electronics
Authors:
Felix T. Jaeckel,
Randy J. Lafler,
S. T. P. Boyd
Abstract:
Commercially available computer-controlled SQUID electronics are usually delivered with software providing a basic user interface for adjustment of SQUID tuning parameters, such as bias current, flux offset, and feedback loop settings. However, in a research context it would often be useful to be able to modify this code and/or to have full control over all these parameters from researcher-written…
▽ More
Commercially available computer-controlled SQUID electronics are usually delivered with software providing a basic user interface for adjustment of SQUID tuning parameters, such as bias current, flux offset, and feedback loop settings. However, in a research context it would often be useful to be able to modify this code and/or to have full control over all these parameters from researcher-written software. In the case of the STAR Cryoelectronics PCI/PFL family of SQUID control electronics, the supplied software contains modules for automatic tuning and noise characterization, but does not provide an interface for user code. On the other hand, the Magnicon SQUIDViewer software package includes a public application programming interface (API), but lacks auto-tuning and noise characterization features. To overcome these and other limitations, we are develo** an "open-source" framework for controlling SQUID electronics which should provide maximal interoperability with user software, a unified user interface for electronics from different manufacturers, and a flexible platform for the rapid development of customized SQUID auto-tuning and other advanced features. We have completed a first implementation for the STAR Cryoelectronics hardware and have made the source code for this ongoing project available to the research community on SourceForge (http://opensquid.sourceforge.net) under the GNU public license.
△ Less
Submitted 2 January, 2013; v1 submitted 1 November, 2012;
originally announced November 2012.