Optical calibration of the SNO+ detector in the water phase with deployed sources
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
F. Barão,
N. Barros,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
M. Chen,
O. Chkvorets,
B. Cleveland,
D. Cookman,
J. Corning,
M. A. Cox,
C. Deluce,
M. M. Depatie
, et al. (98 additional authors not shown)
Abstract:
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light…
▽ More
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. The calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.
△ Less
Submitted 4 October, 2021; v1 submitted 7 June, 2021;
originally announced June 2021.
-
Factoring Multidimensional Data to Create a Sophisticated Bayes Classifier
Authors:
Anthony LaTorre
Abstract:
In this paper we derive an explicit formula for calculating the marginal likelihood of a given factorization of a categorical dataset. Since the marginal likelihood is proportional to the posterior probability of the factorization, these likelihoods can be used to order all possible factorizations and select the "best" way to factor the overall distribution from which the dataset is drawn. The bes…
▽ More
In this paper we derive an explicit formula for calculating the marginal likelihood of a given factorization of a categorical dataset. Since the marginal likelihood is proportional to the posterior probability of the factorization, these likelihoods can be used to order all possible factorizations and select the "best" way to factor the overall distribution from which the dataset is drawn. The best factorization can then be used to construct a Bayes classifier which benefits from factoring out mutually independent sets of variables.
△ Less
Submitted 18 May, 2021; v1 submitted 11 May, 2021;
originally announced May 2021.
-
The SNO+ Experiment
Authors:
SNO+ Collaboration,
:,
V. Albanese,
R. Alves,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
S. Back,
F. Barão,
Z. Barnard,
A. Barr,
N. Barros,
D. Bartlett,
R. Bayes,
C. Beaudoin,
E. W. Beier,
G. Berardi,
A. Bialek,
S. D. Biller,
E. Blucher
, et al. (229 additional authors not shown)
Abstract:
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of pr…
▽ More
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of process plants, commissioning efforts, electronics upgrades, data acquisition systems, and calibration techniques. The SNO+ collaboration is reusing the acrylic vessel, PMT array, and electronics of the SNO detector, having made a number of experimental upgrades and essential adaptations for use with the liquid scintillator. With low backgrounds and a low energy threshold, the SNO+ collaboration will also pursue a rich physics program beyond the search for $0νββ$ decay, including studies of geo- and reactor antineutrinos, supernova and solar neutrinos, and exotic physics such as the search for invisible nucleon decay. The SNO+ approach to the search for $0νββ$ decay is scalable: a future phase with high $^{130}$Te-loading is envisioned to probe an effective Majorana mass in the inverted mass ordering region.
△ Less
Submitted 25 August, 2021; v1 submitted 23 April, 2021;
originally announced April 2021.
-
Development, characterisation, and deployment of the SNO+ liquid scintillator
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
D. Bartlett,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
D. Braid,
E. Caden,
E. J. Callaghan,
J. Caravaca
, et al. (201 additional authors not shown)
Abstract:
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity,…
▽ More
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity, ease of handling, and logistical availability. Its properties have been extensively characterized and are presented here. This liquid scintillator is now used in several neutrino physics experiments in addition to SNO+.
△ Less
Submitted 21 February, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Measurement of neutron-proton capture in the SNO+ water phase
Authors:
The SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
N. Barros,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
D. Chauhan,
M. Chen,
O. Chkvorets,
B. Cleveland,
M. A. Cox,
M. M. Depatie,
J. Dittmer
, et al. (108 additional authors not shown)
Abstract:
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.…
▽ More
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.2-MeV capture $γ$ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. In addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb.
△ Less
Submitted 13 July, 2020; v1 submitted 24 February, 2020;
originally announced February 2020.
-
Search for invisible modes of nucleon decay in water with the SNO+ detector
Authors:
SNO+ Collaboration,
:,
M. Anderson,
S. Andringa,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
D. Bartlett,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
D. Braid,
E. Caden,
E. J. Callaghan,
J. Caravaca,
J. Carvalho
, et al. (173 additional authors not shown)
Abstract:
This paper reports results from a search for nucleon decay through 'invisible' modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently de-excite, often emitting detectable gamma rays. A search for such gamma rays yields limits of…
▽ More
This paper reports results from a search for nucleon decay through 'invisible' modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently de-excite, often emitting detectable gamma rays. A search for such gamma rays yields limits of $2.5 \times 10^{29}$ y at 90% Bayesian credibility level (with a prior uniform in rate) for the partial lifetime of the neutron, and $3.6 \times 10^{29}$ y for the partial lifetime of the proton, the latter a 70% improvement on the previous limit from SNO. We also present partial lifetime limits for invisible dinucleon modes of $1.3\times 10^{28}$ y for $nn$, $2.6\times 10^{28}$ y for $pn$ and $4.7\times 10^{28}$ y for $pp$, an improvement over existing limits by close to three orders of magnitude for the latter two.
△ Less
Submitted 13 December, 2018;
originally announced December 2018.
-
Neutron detection in the SNO+ water phase
Authors:
Y. Liu,
S. Andringa,
D. Auty,
F. Barão,
R. Bayes,
E. Caden,
C. Grant,
J. Grove,
B. Krar,
A. LaTorre,
L. Lebanowski,
J. Lidgard,
J. Maneira,
P. Mekarski,
S. Nae,
T. Pershing,
I. Semenec,
K. Singh,
P. Skensved,
B. Tam,
A. Wright
Abstract:
SNO+ is a multipurpose neutrino experiment located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector started taking physics data in May 2017 and is currently completing its first phase, as a pure water Cherenkov detector. The low trigger threshold of the SNO+ detector allows for a substantial neutron detection efficiency, as observed with a deployed ^{241}Am^{9}Be source. Usi…
▽ More
SNO+ is a multipurpose neutrino experiment located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector started taking physics data in May 2017 and is currently completing its first phase, as a pure water Cherenkov detector. The low trigger threshold of the SNO+ detector allows for a substantial neutron detection efficiency, as observed with a deployed ^{241}Am^{9}Be source. Using a statistical analysis of one hour AmBe calibration data, we report a neutron capture constant of 208.2 + 2.1(stat.) us and a lower bound of the neutron detection efficiency of 46% at the center of the detector.
△ Less
Submitted 21 August, 2018;
originally announced August 2018.
-
Current Status and Future Prospects of the SNO+ Experiment
Authors:
SNO+ Collaboration,
:,
S. Andringa,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
D. Braid,
E. Caden,
E. Callaghan,
J. Caravaca,
J. Carvalho,
L. Cavalli,
D. Chauhan,
M. Chen,
O. Chkvorets,
K. Clark
, et al. (133 additional authors not shown)
Abstract:
SNO+ is a large liquid scintillator-based experiment located 2km underground at SNOLAB, Sudbury, Canada. It reuses the Sudbury Neutrino Observatory detector, consisting of a 12m diameter acrylic vessel which will be filled with about 780 tonnes of ultra-pure liquid scintillator. Designed as a multipurpose neutrino experiment, the primary goal of SNO+ is a search for the neutrinoless double-beta de…
▽ More
SNO+ is a large liquid scintillator-based experiment located 2km underground at SNOLAB, Sudbury, Canada. It reuses the Sudbury Neutrino Observatory detector, consisting of a 12m diameter acrylic vessel which will be filled with about 780 tonnes of ultra-pure liquid scintillator. Designed as a multipurpose neutrino experiment, the primary goal of SNO+ is a search for the neutrinoless double-beta decay (0$νββ$) of 130Te. In Phase I, the detector will be loaded with 0.3% natural tellurium, corresponding to nearly 800 kg of 130Te, with an expected effective Majorana neutrino mass sensitivity in the region of 55-133 meV, just above the inverted mass hierarchy. Recently, the possibility of deploying up to ten times more natural tellurium has been investigated, which would enable SNO+ to achieve sensitivity deep into the parameter space for the inverted neutrino mass hierarchy in the future. Additionally, SNO+ aims to measure reactor antineutrino oscillations, low-energy solar neutrinos, and geoneutrinos, to be sensitive to supernova neutrinos, and to search for exotic physics. A first phase with the detector filled with water will begin soon, with the scintillator phase expected to start after a few months of water data taking. The 0$νββ$ Phase I is foreseen for 2017.
△ Less
Submitted 28 January, 2016; v1 submitted 24 August, 2015;
originally announced August 2015.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Update on the MiniCLEAN Dark Matter Experiment
Authors:
K. Rielage,
M. Akashi-Ronquest,
M. Bodmer,
R. Bourque,
B. Buck,
A. Butcher,
T. Caldwell,
Y. Chen,
K. Coakley,
E. Flores,
J. A. Formaggio,
D. Gastler,
F. Giuliani,
M. Gold,
E. Grace,
J. Griego,
N. Guerrero,
V. Guiseppe,
R. Henning,
A. Hime,
S. Jaditz,
C. Kachulis,
E. Kearns,
J. Kelsey,
J. R. Klein
, et al. (21 additional authors not shown)
Abstract:
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o…
▽ More
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
Characterization of the Hamamatsu R11780 12 inch Photomultiplier Tube
Authors:
J. Brack,
B. Delgado,
J. Dhooghe,
J. Felde,
B. Gookin,
S. Grullon,
J. R. Klein,
R. Knapik,
A. LaTorre,
S. Seibert,
K. Shapiro,
R. Svoboda,
L. Ware,
R. Van Berg
Abstract:
Future large water Cherenkov and scintillator detectors have been proposed for measurements of long baseline neutrino oscillations, proton decay, supernova and solar neutrinos. To ensure cost-effectiveness and optimize scientific reach, one of the critical requirements for such detectors are large-area, high performance photomultiplier tubes (PMTs). One candidate for such a device is the Hamamatsu…
▽ More
Future large water Cherenkov and scintillator detectors have been proposed for measurements of long baseline neutrino oscillations, proton decay, supernova and solar neutrinos. To ensure cost-effectiveness and optimize scientific reach, one of the critical requirements for such detectors are large-area, high performance photomultiplier tubes (PMTs). One candidate for such a device is the Hamamatsu R11780, a 12" PMT that is available in both standard and high quantum efficiency versions. Measurements of the single photoelectron response characteristics, relative efficiencies of the standard and high quantum efficiency versions, a preliminary measurement of the absolute quantum efficiency of the standard quantum efficiency version, and a two-dimensional scan of the relative efficiency across the photocathode surface are presented in this paper. All single photoelectron investigations were made using a Cherenkov light source at room temperature at a gain of 1*10^7. These results show that the R11780 PMT is a excellent candidate for such large optical detectors, including the peak-to-valley ratios greater than 2, transit time spreads around 1.3 ns, and late-pulsing probabilities less than 5%.
△ Less
Submitted 7 February, 2013; v1 submitted 9 October, 2012;
originally announced October 2012.