-
3D seismic survey design by maximizing the spectral gap
Authors:
Yijun Zhang,
Ziyi Yin,
Oscar López,
Ali Siahkoohi,
Mathias Louboutin,
Felix J. Herrmann
Abstract:
The massive cost of 3D acquisition calls for methods to reduce the number of receivers by designing optimal receiver sampling masks. Recent studies on 2D seismic showed that maximizing the spectral gap of the subsampling mask leads to better wavefield reconstruction results. We enrich the current study by proposing a simulation-free method to generate optimal 3D acquisition by maximizing the spect…
▽ More
The massive cost of 3D acquisition calls for methods to reduce the number of receivers by designing optimal receiver sampling masks. Recent studies on 2D seismic showed that maximizing the spectral gap of the subsampling mask leads to better wavefield reconstruction results. We enrich the current study by proposing a simulation-free method to generate optimal 3D acquisition by maximizing the spectral gap of the subsampling mask via a simulated annealing algorithm. Numerical experiments confirm improvement of the proposed method over receiver sampling locations obtained by jittered sampling.
△ Less
Submitted 3 November, 2023;
originally announced November 2023.
-
Near-to mid-IR spectral purity transfer with a tunable frequency comb: methanol frequency metrology over a record frequency span
Authors:
D B A Tran,
Olivier Lopez,
M Manceau,
A Goncharov,
Michel Abgrall,
H Alvarez-Martinez,
R Le Targat,
E Cantin,
P. -E Pottie,
A Amy-Klein,
B Darquié
Abstract:
We report the development and operation of a frequency-comb-assisted high-resolution mid-infrared molecular spectrometer combining high spectral purity, SI-traceability, wide tunability and high sensitivity. An optical frequency comb is used to transfer the spectral purity of a SI-traceable 1.54 $μ$m metrology-grade frequency reference to a 10.3 $μ$m quantum cascade laser (QCL). The near-infrared…
▽ More
We report the development and operation of a frequency-comb-assisted high-resolution mid-infrared molecular spectrometer combining high spectral purity, SI-traceability, wide tunability and high sensitivity. An optical frequency comb is used to transfer the spectral purity of a SI-traceable 1.54 $μ$m metrology-grade frequency reference to a 10.3 $μ$m quantum cascade laser (QCL). The near-infrared reference is operated at the French time/frequency metrology institute, calibrated there to primary frequency standards, and transferred to Laboratoire de Physique des Lasers via the REFIMEVE fiber network. The QCL exhibits a sub-10 --15 frequency stability from 0.1 to 10 s and its frequency is traceable to the SI with a total uncertainty better than 4 x 10 --14 after 1-s averaging time. We have developed the instrumentation allowing comb modes to be continuously tuned over 9 GHz resulting in a QCL of record spectral purity uninterruptedly tunable at the precision of the reference over an unprecedented span of 1.4 GHz. We have used our apparatus to conduct sub-Doppler spectroscopy of methanol in a multi-pass cell, demonstrating state-of-art frequency uncertainties down to the few kilohertz level. We have observed weak intensity resonances unreported so far, resolved subtle doublets never seen before and brought to light discrepancies with the HITRAN database. This demonstrates the potential of our apparatus for probing subtle internal molecular processes, building accurate spectroscopic models of polyatomic molecules of atmospheric or astrophysical interest, and carrying out precise spectroscopic tests of fundamental physics.
△ Less
Submitted 27 October, 2023;
originally announced October 2023.
-
The Analytical Method algorithm for trigger primitives generation at the LHC Drift Tubes detector
Authors:
G. Abbiendi,
J. Alcaraz Maestre,
A. Álvarez Fernández,
B. Álvarez González,
N. Amapane,
I. Bachiller,
L. Barcellan,
C. Baldanza,
C. Battilana,
M. Bellato,
G. Bencze,
M. Benettoni,
N. Beni,
A. Benvenuti,
A. Bergnoli,
L. C. Blanco Ramos,
L. Borgonovi,
A. Bragagnolo,
V. Cafaro,
A. Calderon,
E. Calvo,
R. Carlin,
C. A. Carrillo Montoya,
F. R. Cavallo,
J. M. Cela Ruiz
, et al. (121 additional authors not shown)
Abstract:
The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency and rates, the full electronics of the CMS Drift Tube (DT) chambers will need to be replaced. In the new design, the time bin for the digitisation of the chamber signals will be of around 1~ns, and the totality of the s…
▽ More
The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency and rates, the full electronics of the CMS Drift Tube (DT) chambers will need to be replaced. In the new design, the time bin for the digitisation of the chamber signals will be of around 1~ns, and the totality of the signals will be forwarded asynchronously to the service cavern at full resolution. The new backend system will be in charge of building the trigger primitives of each chamber. These trigger primitives contain the information at chamber level about the muon candidates position, direction, and collision time, and are used as input in the L1 CMS trigger. The added functionalities will improve the robustness of the system against ageing. An algorithm based on analytical solutions for reconstructing the DT trigger primitives, called Analytical Method, has been implemented both as a software C++ emulator and in firmware. Its performance has been estimated using the software emulator with simulated and real data samples, and through hardware implementation tests. Measured efficiencies are 96 to 98\% for all qualities and time and spatial resolutions are close to the ultimate performance of the DT chambers. A prototype chain of the HL-LHC electronics using the Analytical Method for trigger primitive generation has been installed during Long Shutdown 2 of the LHC and operated in CMS cosmic data taking campaigns in 2020 and 2021. Results from this validation step, the so-called Slice Test, are presented.
△ Less
Submitted 3 February, 2023;
originally announced February 2023.
-
Optimized time-lapse acquisition design via spectral gap ratio minimization
Authors:
Yijun Zhang,
Ziyi Yin,
Oscar Lopez,
Ali Siahkoohi,
Mathias Louboutin,
Rajiv Kumar,
Felix J. Herrmann
Abstract:
Modern-day reservoir management and monitoring of geological carbon storage increasingly call for costly time-lapse seismic data collection. In this letter, we show how techniques from graph theory can be used to optimize acquisition geometries for low-cost sparse 4D seismic. Based on midpoint-offset domain connectivity arguments, the proposed algorithm automatically produces sparse non-replicated…
▽ More
Modern-day reservoir management and monitoring of geological carbon storage increasingly call for costly time-lapse seismic data collection. In this letter, we show how techniques from graph theory can be used to optimize acquisition geometries for low-cost sparse 4D seismic. Based on midpoint-offset domain connectivity arguments, the proposed algorithm automatically produces sparse non-replicated time-lapse acquisition geometries that favor wavefield recovery.
△ Less
Submitted 2 February, 2023;
originally announced February 2023.
-
Experimental study of the isospin transport with 40,48 Ca+ 40,48 Ca reactions at 35 MeV/nucleon
Authors:
Q. Fable,
A. Chbihi,
J. D. Frankland,
P. Napolitani,
G. Verde,
E. Bonnet,
B. Borderie,
R. Bougault,
E. Galichet,
T. Génard,
Diego D. Gruyer,
M. Henri,
Marco La Commara,
A. Le Fèvre,
J. Lemarié,
Nicolas Le Neindre,
Olivier Lopez,
M. Pârlog,
A. Rebillard-Soulié,
E. Vient,
M. Vigilante
Abstract:
We investigate the isospin transport with 40,48 Ca+ 40,48 Ca reactions at 35 MeV/nucleon, measured with the coupling of the VAMOS high acceptance spectrometer and the INDRA charged particle multidetector. Using the quasi-projectile remnant measured with VAMOS and carefully selected light-charged-particles measured in coincidence with INDRA, a reconstruction method is applied to estimate the excite…
▽ More
We investigate the isospin transport with 40,48 Ca+ 40,48 Ca reactions at 35 MeV/nucleon, measured with the coupling of the VAMOS high acceptance spectrometer and the INDRA charged particle multidetector. Using the quasi-projectile remnant measured with VAMOS and carefully selected light-charged-particles measured in coincidence with INDRA, a reconstruction method is applied to estimate the excited quasi-projectile (QP) on an event-by-event basis. The isospin diffusion is investigated using the isospin transport ratio with the asymmetry $δ$ = (N -- Z)/A of the projectile as an isospin-sensitive observable and the total transverse energy of Z $\le$ 2 nuclei for experimental centrality sorting. The experimental isospin transport ratios present, for both the reconstructed QP and its remnant, a clear evolution towards isospin equilibration with increasing dissipation of the collision while the full equilibration is not reached. A smoother evolution with less discrepancies between the two mixed systems in the case of the reconstructed QP is also observed. The isospin migration is investigated using the neutron-to-proton ratio of the light-charged-clusters and the velocity of the QP remnant as a sorting parameter. More particularly, we focused on an angular region centered around the mid-rapidity of the reaction so as to characterize the low-density neck emissions. A systematic neutron-enrichment is observed and interpreted as a consequence of isospin migration, more particularly for the symmetric systems which present no isospin gradient between the projectile and the target. We also noticed that the ^{2}H and ^{4}He particles exhibit very close multiplicities independently of the sorting variable for the symmetric systems.
△ Less
Submitted 28 October, 2022;
originally announced October 2022.
-
Experimental study of the $^{40,48}$Ca+ $^{40,48}$Ca reactions at 35 MeV/nucleon
Authors:
Q. Fable,
A. Chbihi,
M. Boisjoli,
J. D. Frankland,
A. Le Fèvre,
N. Le Neindre,
P. Marini,
G. Verde,
G. Ademard,
L. Bardelli,
C. Bhattacharya,
S. Bhattacharya,
E. Bonnet,
B. Borderie,
R. Bougault,
G. Casini,
M. Commara,
R. Dayras,
J. E. Ducret,
F. Farget,
E. Galichet,
T. Génard,
F. Gramegna,
D. Gruyer,
M. Henri
, et al. (19 additional authors not shown)
Abstract:
In this article we investigate $^{40,48}$Ca+$^{40,48}$Ca peripheral and semi-peripheral reactions at 35 MeV/nucleon. Data were obtained using the unique coupling of the VAMOS high acceptance spectrometer and the INDRA charged particle multidetector.The spectrometer allowed high resolution measurement of charge, mass and velocity of the cold projectile-like fragment (PLF), while the INDRA detector…
▽ More
In this article we investigate $^{40,48}$Ca+$^{40,48}$Ca peripheral and semi-peripheral reactions at 35 MeV/nucleon. Data were obtained using the unique coupling of the VAMOS high acceptance spectrometer and the INDRA charged particle multidetector.The spectrometer allowed high resolution measurement of charge, mass and velocity of the cold projectile-like fragment (PLF), while the INDRA detector recorded coincident charged particles with nearly $4π$ acceptance.The measured isotopic composition of the PLF identified in VAMOS and the average light charged particle (LCP) multiplicities are promising observables to study the isospin diffusion.The detection of the PLF in coincidence with LCP allows the reconstruction of the mass, charge and excitation energy of the associated initial quasi-projectile nuclei (QP), as well as the extraction of apparent temperatures.We investigate the suitability of the isoscaling method with the PLF and the experimental reconstructed QP.The extracted $α$ and $Δ$ isoscaling parameters present a dependence on the considered system combination that could justify their use as a surrogate for isospin asymmetry in isospin transport studies.The reconstruction of the QP allows to observe an evolution of the $α/Δ$ with the size of the QP, the latter being consistent with a strong surface contribution to the symmetry energy term in finite nuclei. This leads to the conclusion that the reconstruction of the primary source is mandatory for the study of the symmetry energy term based on the isoscaling method for such reactions.
△ Less
Submitted 30 August, 2022; v1 submitted 28 February, 2022;
originally announced February 2022.
-
Limitations due to residual interference in a fiber-based optical frequency reference at 1.55 $μ$m
Authors:
Karim Manamanni,
Tatiana Steshchenko,
Fabrice Wiotte,
Rodolphe Le Targat,
Michel Abgrall,
Olivier Lopez,
Étienne Cantin,
Paul-Éric Pottie,
Anne Amy-Klein,
Vincent Roncin,
Frédéric Du-Burck
Abstract:
We present an experimental investigation of the stability limits specific to optical frequency standards using a fiber-optic architecture and semiconductor lasers. A compact setup composed of a semiconductor laser frequency-locked onto an acetylene transition detected in saturated absorption has been implemented using only fiber-optic components. Fiber optic technology allows compact and reliable…
▽ More
We present an experimental investigation of the stability limits specific to optical frequency standards using a fiber-optic architecture and semiconductor lasers. A compact setup composed of a semiconductor laser frequency-locked onto an acetylene transition detected in saturated absorption has been implemented using only fiber-optic components. Fiber optic technology allows compact and reliable solutions for various applications. However, for high sensitivity and stability applications such as metrology, residual reflections induced by optical index inhomogeneities in connectors and fiber-coupled components leading to spurious interference significantly limit performance. We have examined the origin of the interference fringes superimposed on the detected signal and the limitations they cause to the frequency stability of the reference. The effects of temperature and beam power fluctuations are also examined. Our results show that the frequency stability is limited in the 10-13 range by the effect of interference fringes due to use of fiber components.
△ Less
Submitted 28 March, 2022; v1 submitted 19 January, 2022;
originally announced January 2022.
-
Brownian dynamics simulations of sphere clusters in optical tweezers
Authors:
Wyatt Vigilante,
Oscar Lopez,
Jerome Fung
Abstract:
Computationally modeling the behavior of wavelength-sized non-spherical particles in optical tweezers can give insight into the existence and stability of trap** equilibria as well as the optical manipulation of such particles more broadly. Here, we report Brownian dynamics simulations of non-spherical particles that account for detailed optical, hydrodynamic, and thermal interactions. We use a…
▽ More
Computationally modeling the behavior of wavelength-sized non-spherical particles in optical tweezers can give insight into the existence and stability of trap** equilibria as well as the optical manipulation of such particles more broadly. Here, we report Brownian dynamics simulations of non-spherical particles that account for detailed optical, hydrodynamic, and thermal interactions. We use a $T$-matrix formalism to calculate the optical forces and torques exerted by focused laser beams on clusters of wavelength-sized spheres, and we incorporate detailed diffusion tensors that capture the anisotropic Brownian motion of the clusters. For two-sphere clusters whose size is comparable to or larger than the wavelength, we observe photokinetic effects in elliptically-polarized beams. We also demonstrate that multiple trap** equilibria exist for a highly asymmetric chiral cluster of seven spheres. Our simulations may lead to practical suggestions for optical trap** and manipulation as well as a deeper understanding of the underlying physics.
△ Less
Submitted 1 September, 2020;
originally announced September 2020.
-
Industrial applications of digital rock technology
Authors:
Carl Fredrik Berg,
Olivier Lopez,
Håvard Berland
Abstract:
This article provides an overview of the current state of digital rock technology, with emphasis on industrial applications. We show how imaging and image analysis can be applied for rock ty** and modeling of end-point saturations. Different methods to obtain a digital model of the pore space from pore scale images are presented, and the strengths and weaknesses of the different methods are disc…
▽ More
This article provides an overview of the current state of digital rock technology, with emphasis on industrial applications. We show how imaging and image analysis can be applied for rock ty** and modeling of end-point saturations. Different methods to obtain a digital model of the pore space from pore scale images are presented, and the strengths and weaknesses of the different methods are discussed. We also show how imaging bridges the different subjects of geology, petrophysics and reservoir simulations, by being a common denominator for results in all these subjects. Network modeling is compared to direct simulations on grid models, and their respective strengths are discussed. Finally we present an example of digital rock technology applied to a sandstone oil reservoir. Results from digital rock modeling are compared to results from traditional laboratory experiments. We highlight the mutual benefits from conducting both traditional experiments and digital rock modeling.
△ Less
Submitted 2 May, 2020;
originally announced May 2020.
-
Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC
Authors:
G. Abbiendi,
J. Alcaraz Maestre,
A. Álvarez Fernández,
B. Álvarez González,
N. Amapane,
I. Bachiller,
J. M. Barcala,
L. Barcellan,
C. Battilana,
M. Bellato,
G. Bencze,
M. Benettoni,
N. Beni,
A. Benvenuti,
L. C. Blanco Ramos,
A. Boletti,
A. Bragagnolo,
J. A. Brochero Cifuentes,
V. Cafaro,
A. Calderon,
E. Calvo,
A. Cappati,
R. Carlin,
C. A. Carrillo Montoya,
F. R. Cavallo
, et al. (118 additional authors not shown)
Abstract:
The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irrad…
▽ More
The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irradiation facility (GIF++), at large ($\sim$O(100)) acceleration factor, showed ageing effects resulting in a degradation of the DT cell performance. However, full CMS simulations have shown almost no impact in the muon reconstruction efficiency over the full barrel acceptance and for the full integrated luminosity. A second spare DT chamber was moved inside the GIF++ bunker in October 2017. The chamber was being irradiated at lower acceleration factors, and only 2 out of the 12 layers of the chamber were switched at working voltage when the radioactive source was active, being the other layers in standby. In this way the other non-aged layers are used as reference and as a precise and unbiased telescope of muon tracks for the efficiency computation of the aged layers of the chamber, when set at working voltage for measurements. An integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC run has been absorbed by this second spare DT chamber and the final impact on the muon reconstruction efficiency is under study. Direct inspection of some extracted aged anode wires presented a melted resistive deposition of materials. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway. Strategies to mitigate the ageing effects are also being developed. From the long irradiation measurements of the second spare DT chamber, the effects of radiation in the performance of the DTs expected during the HL-LHC run will be presented.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
A new experiment to test parity symmetry in cold chiral molecules using vibrational spectroscopy
Authors:
A Cournol,
M. Manceau,
M. Pierens,
L Lecordier,
D Tran,
R. Santagata,
B. Argence,
A Goncharov,
O. Lopez,
M. Abgrall,
Y. Le Coq,
R. Le Targat,
H Alvarez Martinez,
W Lee,
D Xu,
P-E Pottie,
R Hendricks,
T Wall,
J Bieniewska,
B Sauer,
M. Tarbutt,
A. Amy-Klein,
S. Tokunaga,
B. Darquié
Abstract:
We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addressing the main challenges, including the development of buffer-gas sources of slow, cold polyatomic molecules, and the frequency-stabilisation of quantum cascade lasers calibrated using primary frequency standards. We re…
▽ More
We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addressing the main challenges, including the development of buffer-gas sources of slow, cold polyatomic molecules, and the frequency-stabilisation of quantum cascade lasers calibrated using primary frequency standards. We report investigations on achiral test species of which promising chiral derivatives have been synthesized.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
Combining fiber Brillouin amplification with a repeater laser station for fiber-based optical frequency dissemination over 1400 km
Authors:
Sebastian Koke,
Alexander Kuhl,
Thomas Waterholter,
Sebastian M. F. Raupach,
Olivier Lopez,
Etienne Cantin,
Nicolas Quintin,
Anne Amy-Klein,
Paul-Eric Pottie,
Gesine Grosche
Abstract:
We investigate optical frequency dissemination over a 1400 km long fiber link in looped configuration over a pair of underground fibers between Braunschweig and Strasbourg. This fiber link is the first to combine fiber Brillouin amplifiers with a repeater laser station. Phase-coherent operation over more than five days is demonstrated. We analyze the repeatability of the performance over four camp…
▽ More
We investigate optical frequency dissemination over a 1400 km long fiber link in looped configuration over a pair of underground fibers between Braunschweig and Strasbourg. This fiber link is the first to combine fiber Brillouin amplifiers with a repeater laser station. Phase-coherent operation over more than five days is demonstrated. We analyze the repeatability of the performance over four campaigns and present results of 65 days in total. The weighted mean of the fractional frequency offset of the transferred optical frequency over the complete data set is $(-1.1 \pm 0.4) \times 10^{-20}$. By analyzing the stabilization signals of the two individual fibers, the correlation of the phase noise on the two fibers is shown to be >98%.
△ Less
Submitted 29 October, 2019;
originally announced November 2019.
-
First industrial-grade coherent fiber link for optical frequency standard dissemination
Authors:
F. Guillou-Camargo,
V. Ménoret,
E. Cantin,
O. Lopez,
N. Quintin,
E. Camisard,
V. Salmon,
J. -M. Le Merdy,
G. Santarelli,
A. Amy-Klein,
P. -E. Pottie,
B. Desruelle,
C. Chardonnet
Abstract:
We report on a fully bi-directional 680~km fiber link connecting two cities for which the equipment, the set up and the characterization are managed for the first time by an industrial consortium. The link uses an active telecommunication fiber network with parallel data traffic and is equipped with three repeater laser stations and four remote double bi-directional Erbium-doped fiber amplifiers.…
▽ More
We report on a fully bi-directional 680~km fiber link connecting two cities for which the equipment, the set up and the characterization are managed for the first time by an industrial consortium. The link uses an active telecommunication fiber network with parallel data traffic and is equipped with three repeater laser stations and four remote double bi-directional Erbium-doped fiber amplifiers. We report a short term stability at 1~s integration time of $5.4\times 10^{-16}$ in 0.5~Hz bandwidth and a long term stability of $1.7\times10^{-20}$ at 65\,000 s of integration time. The accuracy of the frequency transfer is evaluated as $3\times 10^{-20}$. No shift is observed within the statistical uncertainty. We show a continuous operation over 5 days with an uptime of 99.93$\%$. This performance is comparable with the state of the art coherent links established between National Metrology Institutes in Europe. It is a first step in the construction of an optical fiber network for metrology in France, which will give access to an ultra-high performance frequency standard to a wide community of scientific users.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
Two-Branch Fiber Link for International Clock Networks
Authors:
Dan Xu,
Etienne Cantin,
Florian Frank,
Nicolas Quintin,
Frédéric Meynadier,
Philip Tuckey,
Anne Amy-Klein,
Olivier Lopez,
Paul-Eric Pottie
Abstract:
We present our work on realizing two-branch fiber links enabling multiple-partner clock comparisons in Europe. We report in detail on the setup connecting two long haul links, and report for the relative frequency stability and accuracy. We report on a combined uptime of 90% for our dual-branch link during almost one month. We finally discuss the combined uncertainty contribution of the ensemble o…
▽ More
We present our work on realizing two-branch fiber links enabling multiple-partner clock comparisons in Europe. We report in detail on the setup connecting two long haul links, and report for the relative frequency stability and accuracy. We report on a combined uptime of 90% for our dual-branch link during almost one month. We finally discuss the combined uncertainty contribution of the ensemble of the link architecture to a clock comparison. We show that the frequency transfer uncertainty is 2 x 10 --19 .
△ Less
Submitted 4 September, 2019;
originally announced September 2019.
-
Studying fundamental limit of optical fiber links to $10^{-21}$ level
Authors:
Dan Xu,
Won-kyu Lee,
Fabio Stefani,
Olivier Lopez,
Anne Amy-Klein,
Paul-eric Pottie
Abstract:
We present an hybrid fiber link combining effective optical frequency transfer and evaluation of performances with a self-synchronized two-way comparison. It enables us to detect the round-trip fiber noise and each of the forward and backward one-way fiber noises simultaneously. The various signals acquired with this setup allow us to study quantitatively several properties of optical fiber links.…
▽ More
We present an hybrid fiber link combining effective optical frequency transfer and evaluation of performances with a self-synchronized two-way comparison. It enables us to detect the round-trip fiber noise and each of the forward and backward one-way fiber noises simultaneously. The various signals acquired with this setup allow us to study quantitatively several properties of optical fiber links. We check the reciprocity of the accumulated noise forth and back over a bi-directional fiber to the level of $3.1(\pm 3.9)\times 10^{-20}$ based on a 160000s continuous data. We also analyze the noise correlation between two adjacent fibers and show the first experimental evidence of interferometric noise at very low Fourier frequency. We estimate redundantly and consistently the stability and accuracy of the transferred optical frequency over 43~km at $4\times 10^{-21}$ level after 16 days of integration and demonstrate that frequency comparison with instability as low as $8\times 10^{-18}$ would be achievable with uni-directional fibers in urban area.
△ Less
Submitted 26 July, 2019;
originally announced July 2019.
-
High-precision methanol spectroscopy with a widely tunable SI-traceable frequency-comb-based mid-infrared QCL
Authors:
R. Santagata,
D. Tran,
B. Argence,
O. Lopez,
S. Tokunaga,
F. Wiotte,
H. Mouhamad,
A. Goncharov,
M. Abgrall,
Y. Le Coq,
H. Alvarez-Martinez,
R. Le Targat,
W. Lee,
D. Xu,
P. -E. Pottie,
B. Darquié,
A. Amy-Klein
Abstract:
There is an increasing demand for precise molecular spectroscopy, in particular in the mid-infrared fingerprint window that hosts a considerable number of vibrational signatures, whether it be for modeling our atmosphere, interpreting astrophysical spectra or testing fundamental physics. We present a high-resolution mid-infrared spectrometer traceable to primary frequency standards. It combines a…
▽ More
There is an increasing demand for precise molecular spectroscopy, in particular in the mid-infrared fingerprint window that hosts a considerable number of vibrational signatures, whether it be for modeling our atmosphere, interpreting astrophysical spectra or testing fundamental physics. We present a high-resolution mid-infrared spectrometer traceable to primary frequency standards. It combines a widely tunable ultra-narrow Quantum Cascade Laser (QCL), an optical frequency comb and a compact multipass cell. The QCL frequency is stabilized onto a comb controlled with a remote near-infrared ultra-stable laser, transferred through a fiber link. The resulting QCL frequency stability is below 10-15 from 0.1 to 10s and its frequency uncertainty of 4x10-14 is given by the remote frequency standards. Continuous tuning over ~400 MHz is reported. We use the apparatus to perform saturated absorption spectroscopy of methanol in the low-pressure multipass cell and demonstrate a statistical uncertainty at the kHz level on transition center frequencies, confirming its potential for driving the next generation technology required for precise spectroscopic measurements.
△ Less
Submitted 23 July, 2019;
originally announced July 2019.
-
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Authors:
B. M. Roberts,
P. Delva,
A. Al-Masoudi,
A. Amy-Klein,
C. Bærentsen,
C. F. A. Baynham,
E. Benkler,
S. Bilicki,
S. Bize,
W. Bowden,
J. Calvert,
V. Cambier,
E. Cantin,
E. A. Curtis,
S. Dörscher,
M. Favier,
F. Frank,
P. Gill,
R. M. Godun,
G. Grosche,
C. Guo,
A. Hees,
I. R. Hill,
R. Hobson,
N. Huntemann
, et al. (29 additional authors not shown)
Abstract:
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17…
▽ More
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
△ Less
Submitted 8 July, 2019; v1 submitted 4 July, 2019;
originally announced July 2019.
-
The FAZIA setup: a review on the electronics and the mechanical mounting
Authors:
S. Valdré,
G. Casini,
N. Le Neindre,
M. Bini,
A. Boiano,
B. Borderie,
P. Edelbruck,
G. Poggi,
F. Salomon,
G. Tortone,
R. Alba,
S. Barlini,
E. Bonnet,
R. Bougault,
A. Bougard,
G. Brulin,
M. Bruno,
A. Buccola,
A. Camaiani,
A. Chbihi,
C. Ciampi,
M. Cicerchia,
M. Cinausero,
D. Dell'Aquila,
P. Desrues
, et al. (56 additional authors not shown)
Abstract:
In this paper the technological aspects of the FAZIA array will be explored. After a productive commissioning phase, FAZIA blocks started to measure and give very useful data to explore the physics of Fermi energy heavy-ion reactions. This was possible thanks to many technical measures and innovations developed in the commissioning phase and tuned during the first experimental campaigns. This pape…
▽ More
In this paper the technological aspects of the FAZIA array will be explored. After a productive commissioning phase, FAZIA blocks started to measure and give very useful data to explore the physics of Fermi energy heavy-ion reactions. This was possible thanks to many technical measures and innovations developed in the commissioning phase and tuned during the first experimental campaigns. This paper gives a detailed description of the present status of the FAZIA setup from the electronic and mechanical point of view, trying also to trace a path for new improvements and refinements of the apparatus.
△ Less
Submitted 5 April, 2019; v1 submitted 24 September, 2018;
originally announced September 2018.
-
A new "3D Calorimetry" of hot nuclei
Authors:
E. Vient,
L. Manduci,
E. Legouée,
L. Augey,
E. Bonnet,
B. Borderie,
R. Bougault,
A. Chbihi,
D. Dell'Aquila,
Q. Fable,
L. Francalanza,
J. D. Frankland,
E. Galichet,
D. Gruyer,
D. Guinet,
M. Henri,
M. La Commara,
G. Lehaut,
N. Le Neindre,
I. Lombardo,
O. Lopez,
P. Marini,
M. Parlog,
M. F. Rivet,
E. Rosato
, et al. (5 additional authors not shown)
Abstract:
In the domain of Fermi energy, it is extremely complex to isolate experimentally fragments and particles issued from the cooling of a hot nucleus produced during a heavy ion collision. This paper presents a new method to characterize more precisely hot Quasi-Projectiles. It tries to take into account as accurately as possible the distortions generated by all the other potential participants in the…
▽ More
In the domain of Fermi energy, it is extremely complex to isolate experimentally fragments and particles issued from the cooling of a hot nucleus produced during a heavy ion collision. This paper presents a new method to characterize more precisely hot Quasi-Projectiles. It tries to take into account as accurately as possible the distortions generated by all the other potential participants in the nuclear reaction. It is quantitatively shown that this method is a major improvement respect to classic calorimetries used with a 4$π$ detector array. By detailing and deconvolving the different steps of the reconstitution of the hot nucleus, this study shows also the respective role played by the experimental device and the event selection criteria on the quality of the determination of QP characteristics.
△ Less
Submitted 21 September, 2017;
originally announced September 2017.
-
Improving isotopic identification with \emph{INDRA} Silicon-CsI(\emph{Tl}) telescopes
Authors:
O. Lopez,
M. Parlog,
B. Borderie,
M. F. Rivet,
G. Lehaut,
G. Tabacaru,
L. Tassan-got,
P. Pawlowski,
E. Bonnet,
R. Bougault,
A. Chbihi,
D. Dell'Aquila,
J. D. Frankland,
E. Galichet,
D. Gruyer,
M. La Commara,
N. Le Neindre,
I. Lombardo,
L. Manduci,
P. Marini,
J. C. Steckmeyer,
G. Verde,
E. Vient,
J. P. Wieleczko
Abstract:
Profiting from previous works done with the \emph{INDRA} multidetector on the description of the light response $\mathcal L$ of the CsI(\emph{Tl}) crystals to different im**ing nuclei, we propose an improved $ΔE - \mathcal L$ identification-calibration procedure for Silicon-Cesium Iodide (Si-CsI) telescopes, namely an Advanced Mass Estimate (\emph{AME}) method. \emph{AME} is compared to the usua…
▽ More
Profiting from previous works done with the \emph{INDRA} multidetector on the description of the light response $\mathcal L$ of the CsI(\emph{Tl}) crystals to different im**ing nuclei, we propose an improved $ΔE - \mathcal L$ identification-calibration procedure for Silicon-Cesium Iodide (Si-CsI) telescopes, namely an Advanced Mass Estimate (\emph{AME}) method. \emph{AME} is compared to the usual, %$"ΔE - E"$ simple visual analysis of the corresponding two-dimensional map of $ΔE - E$ type, by using \emph{INDRA} experimental data from nuclear reactions induced by heavy ions in the Fermi energy regime. We show that the capability of such telescopes to identify both the atomic $Z$ and the mass $A$ numbers of light and heavy reaction products, can be quantitatively improved thanks to the proposed approach. This conclusion opens new possibilities to use \emph{INDRA} for studying these reactions especially with radioactive beams. Indeed, the determination of the mass for charged reaction products becomes of paramount importance to shed light on the role of the isospin degree of freedom in the nuclear equation of state.
△ Less
Submitted 27 July, 2017;
originally announced July 2017.
-
Test of special relativity using a fiber network of optical clocks
Authors:
P. Delva,
J. Lodewyck,
S. Bilicki,
E. Bookjans,
G. Vallet,
R. Le Targat,
P. -E. Pottie,
C. Guerlin,
F. Meynadier,
C. Le Poncin-Lafitte,
O. Lopez,
A. Amy-Klein,
W. -K. Lee,
N. Quintin,
C. Lisdat,
A. Al-Masoudi,
S. Dörscher,
C. Grebing,
G. Grosche,
A. Kuhl,
S. Raupach,
U. Sterr,
I. R. Hill,
R. Hobson,
W. Bowden
, et al. (6 additional authors not shown)
Abstract:
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted…
▽ More
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson--Mansouri--Sexl parameter $|α|\lesssim 1.1 \times10^{-8}$ quantifying a violation of time dilation, thus improving by a factor of around two the best known constraint obtained with Ives--Stilwell type experiments, and by two orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this paper will improve by orders of magnitude in the near future.
△ Less
Submitted 12 June, 2017; v1 submitted 13 March, 2017;
originally announced March 2017.
-
First international comparison of fountain primary frequency standards via a long distance optical fiber link
Authors:
J. Guéna,
S. Weyers,
M. Abgrall,
C. Grebing,
V. Gerginov,
P. Rosenbusch,
S. Bize,
B. Lipphardt,
H. Denker,
N. Quintin,
S. M. F. Raupach,
D. Nicolodi,
F. Stefani,
N. Chiodo,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
C. Chardonnet,
Y. Le Coq,
M. Lours,
G. Santarelli,
A. Amy-Klein,
R. Le Targat
, et al. (3 additional authors not shown)
Abstract:
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs…
▽ More
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs have been major contributors to accuracy of the International Atomic Time (TAI), with stated accuracies of around $3\times 10^{-16}$. They have also been the references for a number of absolute measurements of clock transition frequencies in various optical frequency standards in view of a future redefinition of the second. The phase coherent optical frequency transfer via a stabilized telecom fiber link enables far better resolution than any other means of frequency transfer based on satellite links. The agreement for each pair of distant fountains compared is well within the combined uncertainty of a few 10$^{-16}$ for all the comparisons, which fully supports the stated PFSs' uncertainties. The comparison also includes a rubidium fountain frequency standard participating in the steering of TAI and enables a new absolute determination of the $^{87}$Rb ground state hyperfine transition frequency with an uncertainty of $3.1\times 10^{-16}$.
This paper is dedicated to the memory of André Clairon, who passed away on the 24$^{th}$ of December 2015, for his pioneering and long-lasting efforts in atomic fountains. He also pioneered optical links from as early as 1997.
△ Less
Submitted 14 March, 2017; v1 submitted 2 March, 2017;
originally announced March 2017.
-
Hybrid fiber links for accurate optical frequency comparisons
Authors:
Won-Kyu Lee,
Fabio Stefani,
Anthony Bercy,
Olivier Lopez,
Anne Amy-Klein,
Paul-Eric Pottie
Abstract:
We present the first experimental demonstration over a 43-km-long urban fiber network of a local two-way optical frequency comparison, which does not require any synchronization of the measurements. It was combined with a regular active-noise compensation on another parallel fiber leading to a very reliable and robust frequency transfer. This hybrid scheme enables us to investigate the major limit…
▽ More
We present the first experimental demonstration over a 43-km-long urban fiber network of a local two-way optical frequency comparison, which does not require any synchronization of the measurements. It was combined with a regular active-noise compensation on another parallel fiber leading to a very reliable and robust frequency transfer. This hybrid scheme enables us to investigate the major limiting factors of the local two-way comparison. We analyze the contribution to the phase noise of the recovered signal by the interferometers at local and remote places. By using the ability of this set up to be injected by a single laser or two independent lasers, we measure the contribution to the long-term instability by the demodulated laser instabilities. We show that a fractional frequency instability level of $1\times10^{-20}$ at 10 000 s can be obtained with this simple setup after 43-km-long propagation in an urban area.
△ Less
Submitted 6 February, 2017;
originally announced February 2017.
-
Semi-automatic charge and mass identification in two-dimensional matrices
Authors:
D. Gruyer,
E. Bonnet,
A. Chbihi,
J. D. Frankland,
S. Barlini,
B. Borderie,
R. Bougault,
J. A. Duenas,
N. Le Neindre,
O. Lopez,
G. Pastore,
S. Piantelli,
S. Valdre,
G. Verde,
E. Vient,
A. Kordyasz,
T. Kozik,
M Pârlog
Abstract:
This article presents a new semi-automatic method for charge and mass identification in two-dimensional matrices. The proposed algorithm is based on the matrix's properties and uses as little information as possible on the global form of the identification lines, making it applicable to a large variety of matrices, including Particular attention has been paid to the implementation in a suitable…
▽ More
This article presents a new semi-automatic method for charge and mass identification in two-dimensional matrices. The proposed algorithm is based on the matrix's properties and uses as little information as possible on the global form of the identification lines, making it applicable to a large variety of matrices, including Particular attention has been paid to the implementation in a suitable graphical environment, so that only two mouse-clicks are required from the user to calculate all initialization parameters. Example applications to recent data from both INDRA and FAZIA telescopes are presented.
△ Less
Submitted 4 August, 2016; v1 submitted 27 July, 2016;
originally announced July 2016.
-
Ultra-stable optical frequency dissemination on a multi-access fibre network
Authors:
Anthony Bercy,
Olivier Lopez,
Paul-Eric Pottie,
Anne Amy-Klein
Abstract:
We report the dissemination of an ultrastable optical frequency signal to two distant users simultaneously using a branching network. The ultrastable signal is extracted along a main fibre link; it is optically tracked with a narrow-linewidth laser diode, which light is injected in a secondary link. The propagation noise of both links is actively compensated. We implement this scheme with two link…
▽ More
We report the dissemination of an ultrastable optical frequency signal to two distant users simultaneously using a branching network. The ultrastable signal is extracted along a main fibre link; it is optically tracked with a narrow-linewidth laser diode, which light is injected in a secondary link. The propagation noise of both links is actively compensated. We implement this scheme with two links of 50-km fibre spools, the extraction being setup at the mid-point of the main link. We show that the extracted signal at the end of the secondary link exhibits fractional frequency instability of 1.4x10-15 at 1-s measurement time, almost equal to the 1.3x10-15 instability of the main link output end. The long-term instabilities are also very similar, at a level of 3-5x10-20 at 3x104-s integration time. We also show that the setting up of this extraction device, or a simpler one, at the main link input, can test the proper functioning of the noise rejection on this main link. This work is a significant step towards a robust and flexible ultra-stable network for multi-users dissemination.
△ Less
Submitted 16 March, 2016;
originally announced March 2016.
-
A clock network for geodesy and fundamental science
Authors:
C. Lisdat,
G. Grosche,
N. Quintin,
C. Shi,
S. M. F. Raupach,
C. Grebing,
D. Nicolodi,
F. Stefani,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
J. -L. Robyr,
N. Chiodo,
S. Bilicki,
E. Bookjans,
A. Koczwara,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
M. Abgrall,
M. Lours,
T. Legero,
H. Schnatz
, et al. (10 additional authors not shown)
Abstract:
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of t…
▽ More
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of the clocks themselves. This is achieved by a phase-coherent optical frequency transfer via a 1415 km long telecom fiber link that enables substantially better precision than classical means of frequency transfer. The fractional precision in comparing the optical clocks of three parts in $10^{17}$ was reached after only 1000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than with any other existing frequency transfer method. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Cascaded optical fiber link using the Internet network for remote clocks comparison
Authors:
Nicola Chiodo,
Nicolas Quintin,
Fabio Stefani,
Fabrice Wiotte,
Emilie Camisard,
Christian Chardonnet,
Giorgio Santarelli,
Anne Amy-Klein,
Paul-Eric Pottie,
Olivier Lopez
Abstract:
We report a cascaded optical link of 1100 km for ultra-stable frequency distribution over an Internet fiber network. The link is composed of four spans for which the propagation noise is actively compensated. The robustness and the performance of the link are ensured by five fully automated optoelectronic stations, two of them at the link ends, and three deployed on the field and connecting the sp…
▽ More
We report a cascaded optical link of 1100 km for ultra-stable frequency distribution over an Internet fiber network. The link is composed of four spans for which the propagation noise is actively compensated. The robustness and the performance of the link are ensured by five fully automated optoelectronic stations, two of them at the link ends, and three deployed on the field and connecting the spans. This device coherently regenerates the optical signal with the heterodyne optical phase locking of a low-noise laser diode. Optical detection of the beat-note signals for the laser lock and the link noise compensation are obtained with stable and low-noise fibered optical interferometer. We show 3.5 days of continuous operation of the noise-compensated 4-span cascaded link leading to fractional frequency instability of 4x10-16 at 1-s measurement time and 1x10-19 at 2000 s. This cascaded link was extended to 1480-km with the same performance. This work is a significant step towards a sustainable wide area ultra-stable optical frequency distribution and comparison network at a very high level of performance.
△ Less
Submitted 22 September, 2015; v1 submitted 19 September, 2015;
originally announced September 2015.
-
Frequency and time transfer for metrology and beyond using telecommunication network fibres
Authors:
Olivier Lopez,
Fabien Kéfélian,
Haifeng Jiang,
Adil Haboucha,
Anthony Bercy,
Fabio Stefani,
Bruno Chanteau,
Amale Kanj,
Daniele Rovera,
Joseph Achkar,
Christian Chardonnet,
Paul-Eric Pottie,
Anne Amy-Klein,
Giorgio Santarelli
Abstract:
The distribution and the comparison of an ultra-stable optical frequency and accurate time using optical fibres have been greatly improved in the last ten years. The frequency stability and accuracy of optical links surpass well-established methods using the global navigation satellite system and geostationary satellites. In this paper, we present a review of the methods and the results obtained.…
▽ More
The distribution and the comparison of an ultra-stable optical frequency and accurate time using optical fibres have been greatly improved in the last ten years. The frequency stability and accuracy of optical links surpass well-established methods using the global navigation satellite system and geostationary satellites. In this paper, we present a review of the methods and the results obtained. We show that public telecommunication network carrying Internet data can be used to compare and distribute ultra-stable metrological signals over long distances. This novel technique paves the way for the deployment of a national and continental ultra-stable metrological optical network.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
Tackling the Limits of Optical Fiber Links
Authors:
Fabio Stefani,
Olivier Lopez,
Anthony Bercy,
Won-Kyu Lee,
Christian Chardonnet,
Giorgio Santarelli,
Paul-Eric Pottie,
Anne Amy-Klein
Abstract:
We theoretically and experimentally investigate relevant noise processes arising in optical fiber links, which fundamentally limit their relative stability. We derive the unsuppressed delay noise for three configurations of optical links: two-way method, Sagnac interferometry, and actively compensated link, respectively designed for frequency comparison, rotation sensing, and frequency transfer. W…
▽ More
We theoretically and experimentally investigate relevant noise processes arising in optical fiber links, which fundamentally limit their relative stability. We derive the unsuppressed delay noise for three configurations of optical links: two-way method, Sagnac interferometry, and actively compensated link, respectively designed for frequency comparison, rotation sensing, and frequency transfer. We also consider an alternative two-way setup allowing real-time frequency comparison and demonstrate its effectiveness on a proof-of-principle experiment with a 25-km fiber spool. For these three configurations, we analyze the noise arising from uncommon fiber paths in the interferometric ensemble and design optimized interferometers. We demonstrate interferometers with very low temperature sensitivity of respectively -2.2, -0.03 and 1 fs/K. We use one of these optimized interferometers on a long haul compensated fiber link of 540km. We obtain a relative frequency stability of 3E-20 after 10,000 s of integration time.
△ Less
Submitted 8 December, 2014;
originally announced December 2014.
-
Quantum cascade laser frequency stabilisation at the sub-Hz level
Authors:
Bérengère Argence,
Bruno Chanteau,
Olivier Lopez,
Daniele Nicolodi,
Michel Abgrall,
Christian Chardonnet,
Christophe Daussy,
Benoît Darquié,
Yann Le Coq,
Anne Amy-Klein
Abstract:
Quantum Cascade Lasers (QCL) are increasingly being used to probe the mid-infrared "molecular fingerprint" region. This prompted efforts towards improving their spectral performance, in order to reach ever-higher resolution and precision. Here, we report the stabilisation of a QCL onto an optical frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and 10-14, respectively. T…
▽ More
Quantum Cascade Lasers (QCL) are increasingly being used to probe the mid-infrared "molecular fingerprint" region. This prompted efforts towards improving their spectral performance, in order to reach ever-higher resolution and precision. Here, we report the stabilisation of a QCL onto an optical frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and 10-14, respectively. The comb is stabilised to a remote near-infrared ultra-stable laser referenced to frequency primary standards, whose signal is transferred via an optical fibre link. The stability and frequency traceability of our QCL exceed those demonstrated so far by two orders of magnitude. As a demonstration of its capability, we then use it to perform high-resolution molecular spectroscopy. We measure absorption frequencies with an 8x10-13 relative uncertainty. This confirms the potential of this setup for ultra-high precision measurements with molecules, such as our ongoing effort towards testing the parity symmetry by probing chiral species.
△ Less
Submitted 6 December, 2014;
originally announced December 2014.
-
Two-Way Optical Frequency Comparisons Over 100km Telecommunication Network Fibers
Authors:
Anthony Bercy,
Fabio Stefani,
Olivier Lopez,
Christian Chardonnet,
Paul-Eric Pottie,
Anne Amy-Klein
Abstract:
By using two-way frequency transfer, we demonstrate ultra-high resolution comparison of optical frequencies over a telecommunication fiber link of 100 km operating simultaneously digital data transfer. We first propose and experiment a bi-directional scheme using a single fiber. We show that the relative stability at 1 s integration time is 7 10^18 and scales down to 5 10^21. The same level of per…
▽ More
By using two-way frequency transfer, we demonstrate ultra-high resolution comparison of optical frequencies over a telecommunication fiber link of 100 km operating simultaneously digital data transfer. We first propose and experiment a bi-directional scheme using a single fiber. We show that the relative stability at 1 s integration time is 7 10^18 and scales down to 5 10^21. The same level of performance is reached when an optical link is implemented with an active compensation of the fiber noise. We also implement a real-time two-way frequency comparison over a uni-directional telecommunication network using a pair of parallel fibers. The relative frequency stability is 10^15 at 1 s integration time and reaches 2 10^17 at 40 000 s. The fractional uncertainty of the frequency comparisons was evaluated for the best case to 2 10^20. These results open the way to accurate and high resolution frequency comparison of optical clocks over intercontinental fiber networks.
△ Less
Submitted 21 August, 2014;
originally announced August 2014.
-
A widely tunable 10-$μ$m quantum cascade laser phase-locked to a state-of-the-art mid-infrared reference for precision molecular spectroscopy
Authors:
Papa Lat Tabara Sow,
Sinda Mejri,
Sean K. Tokunaga,
Olivier Lopez,
Andrey Goncharov,
Bérengère Argence,
Christian Chardonnet,
Anne Amy-Klein,
Christophe Daussy,
Benoît Darquié
Abstract:
We report the coherent phase-locking of a quantum cascade laser (QCL) at 10-$μ$m to the secondary frequency standard of this spectral region, a CO2 laser stabilized on a saturated absorption line of OsO4. The stability and accuracy of the standard are transferred to the QCL resulting in a line width of the order of 10 Hz, and leading to our knowledge to the narrowest QCL to date. The locked QCL is…
▽ More
We report the coherent phase-locking of a quantum cascade laser (QCL) at 10-$μ$m to the secondary frequency standard of this spectral region, a CO2 laser stabilized on a saturated absorption line of OsO4. The stability and accuracy of the standard are transferred to the QCL resulting in a line width of the order of 10 Hz, and leading to our knowledge to the narrowest QCL to date. The locked QCL is then used to perform absorption spectroscopy spanning 6 GHz of NH3 and methyltrioxorhenium, two species of interest for applications in precision measurements.
△ Less
Submitted 4 April, 2014;
originally announced April 2014.
-
Energy measurement and fragment identification using digital signals from partially depleted Si detectors
Authors:
G. Pasquali,
G. Pastore,
N. Le Neindre,
G. Ademard,
S. Barlini,
M. Bini,
E. Bonnet,
B. Borderie,
R. Bougault,
M. Bruno,
G. Casini,
A. Chbihi,
M. Cinausero,
J. A. Duenas,
P. Edelbruck,
J. D. Frankland,
F. Gramegna,
D. Gruyer,
A. Kordyasz,
T. Kozik,
O. Lopez,
T. Marchi,
L. Morelli,
A. Olmi,
A. Ordine
, et al. (14 additional authors not shown)
Abstract:
A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated with a depleted layer ranging from 90% to 60% of the detector thickness. Fragment identification has been performed using either the DE-E technique or Pulse Sha…
▽ More
A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated with a depleted layer ranging from 90% to 60% of the detector thickness. Fragment identification has been performed using either the DE-E technique or Pulse Shape Analysis (PSA). Both detectors are reverse mounted: particles enter from the low field side, to enhance the PSA performance. The achieved charge and mass resolution has been quantitatively expressed using a Figure of Merit (FoM). Charge collection efficiency has been evaluated and the possibility of energy calibration corrections has been considered. We find that the DE-E performance is not affected by incomplete depletion even when only 60% of the wafer is depleted. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds are higher than at full depletion. Good isotopic identification via PSA has been obtained from a partially depleted detector whose do** uniformity is not good enough for isotopic identification at full depletion.
△ Less
Submitted 20 February, 2014;
originally announced February 2014.
-
In-line extraction of an ultra-stable frequency signal over an optical fiber link
Authors:
Anthony Bercy,
Saïda Guellati-Khélifa,
Fabio Stefani,
Giorgio Santarelli,
Christian Chardonnet,
Paul-Eric Pottie,
Olivier Lopez,
Anne Amy-Klein
Abstract:
We demonstrate in-line extraction of an ultra-stable frequency signal over an optical link of 92-km of installed telecommunication fibers, following the proposition of G. Grosche in 2010. We show that the residual frequency noise at the extraction end is noticeably below that at the main link output when the extraction is near the input end, as expected from a simple model of the noise compensatio…
▽ More
We demonstrate in-line extraction of an ultra-stable frequency signal over an optical link of 92-km of installed telecommunication fibers, following the proposition of G. Grosche in 2010. We show that the residual frequency noise at the extraction end is noticeably below that at the main link output when the extraction is near the input end, as expected from a simple model of the noise compensation. We obtain relative frequency instabilities, expressed as overlap** Allan deviation, of 8x10-16 at 1 s averaging time and a few 10-19 at 1 day. These results are at the state-of-the-art for a link using urban telecommunication fibers. We also propose an improved scheme which delivers an ultra-stable signal of higher power, in order to feed a secondary link. In-line extraction opens the way to a broad distribution of an ultra-stable frequency reference, enabling a wide range of applications beyond metrology.
△ Less
Submitted 6 February, 2014;
originally announced February 2014.
-
The european FAZIA initiative: a high-performance digital telescope array for heavy-ion studies
Authors:
G. Casini,
S. Barlini,
G. Pasquali,
G. Pastore,
M. Bini,
S. Carboni,
A. Olmi,
S. Piantelli,
G. Poggi,
A. Stefanini,
S. Valdre',
E. Bonnet,
B. Borderie,
R. Bougault,
M. Bruno,
A. Chbihi,
M. Cinausero,
M. Degerlier,
P. Edelbruck,
J. D. Frankland,
F. Gramegna,
D. Gruyer,
M. Guerzoni,
A. Kordjasz,
T. Kozik
, et al. (14 additional authors not shown)
Abstract:
The european Fazia collaboration aims at building a new modular array for charged product identification to be employed for heavy-ion studies. The elementary module of the array is a Silicon-Silicon-CsI telescope, optimized for ion identification also via pulse shape analysis. The achievement of top performances imposes specific electronics which has been developed by FAZIA and features high quali…
▽ More
The european Fazia collaboration aims at building a new modular array for charged product identification to be employed for heavy-ion studies. The elementary module of the array is a Silicon-Silicon-CsI telescope, optimized for ion identification also via pulse shape analysis. The achievement of top performances imposes specific electronics which has been developed by FAZIA and features high quality charge and current preamplifiers, coupled to fully digital front-end. During the initial R&D phase, original and novel solutions have been tested in prototypes, obtaining unprecedented ion identification capabilities. FAZIA is now constructing a demonstrator array consisting of about two hundreds telescopes arranged in a compact and transportable configuration. In this contribution, we mainly summarize some aspects studied by FAZIA to improve the ion identification. Then we will briefly discuss the FAZIA program centered on experiments to be done with the demonstrator. First results on the isospin dynamics obtained with a reduced set-up demonstrate well the performance of the telescope and represent a good starting point towards future investigations with both stable and exotic beams.
△ Less
Submitted 5 September, 2013;
originally announced September 2013.
-
Mid-infrared laser phase-locking to a remote near-infrared frequency reference for high precision molecular spectroscopy
Authors:
Bruno Chanteau,
Olivier Lopez,
Wei Zhang,
Daniele Nicolodi,
Bérengère Argence,
Frédéric Auguste,
Michel Abgrall,
Christian Chardonnet,
Giorgio Santarelli,
Benoît Darquié,
Yann Le Coq,
Anne Amy-Klein
Abstract:
We present a new method for accurate mid-infrared frequency measurements and stabilization to a near-infrared ultra-stable frequency reference, transmitted with a long-distance fibre link and continuously monitored against state-of-the-art atomic fountain clocks. As a first application, we measure the frequency of an OsO4 rovibrational molecular line around 10 $μ$m with a state-of-the-art uncertai…
▽ More
We present a new method for accurate mid-infrared frequency measurements and stabilization to a near-infrared ultra-stable frequency reference, transmitted with a long-distance fibre link and continuously monitored against state-of-the-art atomic fountain clocks. As a first application, we measure the frequency of an OsO4 rovibrational molecular line around 10 $μ$m with a state-of-the-art uncertainty of 8x10-13. We also demonstrate the frequency stabilization of a mid-infrared laser with fractional stability better than 4x10-14 at 1 s averaging time and a line-width below 17 Hz. This new stabilization scheme gives us the ability to transfer frequency stability in the range of 10-15 or even better, currently accessible in the near-infrared or in the visible, to mid-infrared lasers in a wide frequency range.
△ Less
Submitted 29 April, 2013;
originally announced April 2013.
-
Mid-IR frequency measurement using an optical frequency comb and a long-distance remote frequency reference
Authors:
Bruno Chanteau,
Olivier Lopez,
Wei Zhang,
Giorgio Santarelli,
Yann Le Coq,
Frédéric Auguste,
Benoît Darquié,
Christian Chardonnet,
Anne Amy-Klein
Abstract:
We have built a frequency chain which enables to measure the absolute frequency of a laser emitting in the 28-31 THz frequency range and stabilized onto a molecular absorption line. The set-up uses an optical frequency comb and an ultrastable 1.55 $μ$m frequency reference signal, transferred from LNE-SYRTE to LPL through an optical link. We are now progressing towards the stabilization of the mid-…
▽ More
We have built a frequency chain which enables to measure the absolute frequency of a laser emitting in the 28-31 THz frequency range and stabilized onto a molecular absorption line. The set-up uses an optical frequency comb and an ultrastable 1.55 $μ$m frequency reference signal, transferred from LNE-SYRTE to LPL through an optical link. We are now progressing towards the stabilization of the mid-IR laser via the frequency comb and the extension of this technique to quantum cascade lasers. Such a development is very challenging for ultrahigh resolution molecular spectroscopy and fundamental tests of physics with molecules.
△ Less
Submitted 13 October, 2012;
originally announced October 2012.
-
Simultaneous remote transfer of accurate timing and optical frequency over a public fiber network
Authors:
Olivier Lopez,
Amale Kanj,
Paul-Eric Pottie,
Giovanni D. Rovera,
Joseph Achkar,
Christian Chardonnet,
Anne Amy-Klein,
Giorgio Santarelli
Abstract:
In this work we demonstrate for the first time that it is possible to transfer simultaneously an ultra-stable optical frequency and a precise and accurate timing over 540 km using a public telecommunication optical fiber networks with Internet data. The optical phase is used to carry both the frequency information and the timestamps by modulating a very narrow optical carrier at 1.55 $μ$m with spr…
▽ More
In this work we demonstrate for the first time that it is possible to transfer simultaneously an ultra-stable optical frequency and a precise and accurate timing over 540 km using a public telecommunication optical fiber networks with Internet data. The optical phase is used to carry both the frequency information and the timestamps by modulating a very narrow optical carrier at 1.55 $μ$m with spread spectrum signals using two-way satellite time transfer modems. The results in term of absolute time accuracy (250 ps) and long-term timing stability (20 ps) well outperform the conventional Global Navigation Satellite System or geostationary transfer methods.
△ Less
Submitted 4 October, 2012; v1 submitted 21 September, 2012;
originally announced September 2012.
-
Ultra-stable long distance optical frequency distribution using the Internet fiber network
Authors:
Olivier Lopez,
Adil Haboucha,
Bruno Chanteau,
Christian Chardonnet,
Anne Amy-Klein,
Giorgio Santarelli
Abstract:
We report an optical link of 540 km for ultrastable frequency distribution over the Internet fiber network. The stable frequency optical signal is processed enabling uninterrupted propagation on both directions. The robustness and the performance of the link are enhanced by a cost effective fully automated optoelectronic station. This device is able to coherently regenerate the return optical sign…
▽ More
We report an optical link of 540 km for ultrastable frequency distribution over the Internet fiber network. The stable frequency optical signal is processed enabling uninterrupted propagation on both directions. The robustness and the performance of the link are enhanced by a cost effective fully automated optoelectronic station. This device is able to coherently regenerate the return optical signal with a heterodyne optical phase locking of a low noise laser diode. Moreover the incoming signal polarization variation are tracked and processed in order to maintain beat note amplitudes within the operation range. Stable fibered optical interferometer enables optical detection of the link round trip phase signal. The phase-noise compensated link shows a fractional frequency instability in 10 Hz bandwidth of 5x10-15 at one second measurement time and 2x10-19 at 30 000 s. This work is a significant step towards a sustainable wide area ultrastable optical frequency distribution and comparison network.
△ Less
Submitted 28 September, 2012; v1 submitted 25 June, 2012;
originally announced June 2012.
-
Cascaded multiplexed optical link on a telecommunication network for frequency dissemination
Authors:
Olivier Lopez,
Adil Haboucha,
Fabien Kéfélian,
Haifeng Jiang,
Bruno Chanteau,
Vincent Roncin,
Christian Chardonnet,
Anne Amy-Klein,
Georgio Santarelli
Abstract:
We demonstrate a cascaded optical link for ultrastable frequency dissemination comprised of two compensated links of 150 km and a repeater station. Each link includes 114 km of Internet fiber simultaneously carrying data traffic through a dense wavelength division multiplexing technology, and passes through two routing centers of the telecommunication network. The optical reference signal is inser…
▽ More
We demonstrate a cascaded optical link for ultrastable frequency dissemination comprised of two compensated links of 150 km and a repeater station. Each link includes 114 km of Internet fiber simultaneously carrying data traffic through a dense wavelength division multiplexing technology, and passes through two routing centers of the telecommunication network. The optical reference signal is inserted in and extracted from the communication network using bidirectional optical add-drop multiplexers. The repeater station operates autonomously ensuring noise compensation on the two links and the ultra-stable signal optical regeneration. The compensated link shows a fractional frequency instability of 3 \times 10-15 at one second measurement time and 5 \times 10-20 at 20 hours. This work paves the way to a wide dissemination of ultra-stable optical clock signals between distant laboratories via the Internet network.
△ Less
Submitted 27 September, 2010;
originally announced September 2010.
-
Determination of the Boltzmann constant by laser spectroscopy as a basis for future measurements of the thermodynamic temperature
Authors:
Cyril Lemarchand,
Khelifa Djerroud,
Benoît Darquié,
Olivier Lopez,
Anne Amy-Klein,
Christian Chardonnet,
Christian J. Bordé,
Stephan Briaudeau,
Christophe Daussy
Abstract:
In this paper, we present the latest results on the measurement of the Boltzmann constant kB, by laser spectroscopy of ammonia at 10 ?m. The Doppler absorption profile of a ro-vibrational line of an NH3 gas sample at thermal and pressure equilibrium is measured as accurately as possible. The absorption cell is placed inside a large 1m3 thermostat filled with an ice-water mixture, which sets the…
▽ More
In this paper, we present the latest results on the measurement of the Boltzmann constant kB, by laser spectroscopy of ammonia at 10 ?m. The Doppler absorption profile of a ro-vibrational line of an NH3 gas sample at thermal and pressure equilibrium is measured as accurately as possible. The absorption cell is placed inside a large 1m3 thermostat filled with an ice-water mixture, which sets the temperature very close to 273.15 K. Analysing this profile, which is related to the Maxwell-Boltzmann molecular speed distribution, leads to a determination of the Boltzmann constant via a measurement of the Doppler width (proportional tosqrt(kBT)). A spectroscopic determination of the Boltzmann constant with an uncertainty as low as 37 ppm is obtained. Recent improvements with a new passive thermostat lead to a temperature accuracy, stability and homogeneity of the absorption cell better than 1 ppm over a day.
△ Less
Submitted 1 December, 2009; v1 submitted 13 November, 2009;
originally announced November 2009.
-
Measurement of the Boltzmann constant by the Doppler broadening technique at a 3,8x10-5 accuracy level
Authors:
Khelifa Djerroud,
Cyril Lemarchand,
Alexandre Gauguet,
Christophe Daussy,
Stephan Briaudeau,
Benoît Darquié,
Olivier Lopez,
Anne Amy-Klein,
Christian Chardonnet,
Christian J. Bordé
Abstract:
In this paper, we describe an experiment performed at the Laboratoire de Physique des Lasers and dedicated to an optical measurement of the Boltzmann constant. With the proposed innovative technique, determining comes down to an ordinary frequency measurement. The method consists in measuring as accurately as possible the Doppler absorption profile of a rovibrational line of ammonia in thermal e…
▽ More
In this paper, we describe an experiment performed at the Laboratoire de Physique des Lasers and dedicated to an optical measurement of the Boltzmann constant. With the proposed innovative technique, determining comes down to an ordinary frequency measurement. The method consists in measuring as accurately as possible the Doppler absorption profile of a rovibrational line of ammonia in thermal equilibrium. This profile is related to the Maxwell-Boltzmann molecular velocity distribution along the laser beam. A fit of the absorption line shape leads to a determination of the Doppler width proportional to sqrt(kT) and thus to a determination of the Boltzmann constant. The laser source is an ultra-stable CO2 laser with a wavelength . The absorption cell is placed in a thermostat kee** the temperature at 273.15 K within 1.4 mK. We were able to measure with a relative uncertainty as small as 3.8x10-5, which represents an improvement of an order of magnitude for an integration time comparable to our previous measurement published in 2007 [1]
△ Less
Submitted 12 November, 2009;
originally announced November 2009.
-
High-resolution microwave frequency dissemination on an 86-km urban optical link
Authors:
O. Lopez,
A. Amy-Klein,
M. Lours,
Ch. Chardonnet,
G. Santarelli
Abstract:
We report the first demonstration of a long-distance ultra stable frequency dissemination in the microwave range. A 9.15 GHz signal is transferred through a 86-km urban optical link with a fractional frequency stability of 1.3x10-15 at 1 s integration time and below 10-18 at one day. The optical link phase noise compensation is performed with a round-trip method. To achieve such a result we impl…
▽ More
We report the first demonstration of a long-distance ultra stable frequency dissemination in the microwave range. A 9.15 GHz signal is transferred through a 86-km urban optical link with a fractional frequency stability of 1.3x10-15 at 1 s integration time and below 10-18 at one day. The optical link phase noise compensation is performed with a round-trip method. To achieve such a result we implement light polarisation scrambling and dispersion compensation. This link outperforms all the previous radiofrequency links and compares well with recently demonstrated full optical links.
△ Less
Submitted 12 November, 2009; v1 submitted 20 July, 2009;
originally announced July 2009.
-
Long-distance frequency transfer over an urban fiber link using optical phase stabilization
Authors:
Haifeng Jiang,
Fabien Kéfélian,
Scott Crane,
Olivier Lopez,
Michel Lours,
Jacques Millo,
David Holleville,
Pierre Lemonde,
Christian Chardonnet,
Anne Amy-Klein,
Georgio Santarelli
Abstract:
We transferred the frequency of an ultra-stable laser over 86 km of urban fiber. The link is composed of two cascaded 43-km fibers connecting two laboratories, LNE-SYRTE and LPL in Paris area. In an effort to realistically demonstrate a link of 172 km without using spooled fiber extensions, we implemented a recirculation loop to double the length of the urban fiber link. The link is fed with a 1…
▽ More
We transferred the frequency of an ultra-stable laser over 86 km of urban fiber. The link is composed of two cascaded 43-km fibers connecting two laboratories, LNE-SYRTE and LPL in Paris area. In an effort to realistically demonstrate a link of 172 km without using spooled fiber extensions, we implemented a recirculation loop to double the length of the urban fiber link. The link is fed with a 1542-nm cavity stabilized fiber laser having a sub-Hz linewidth. The fiber-induced phase noise is measured and cancelled with an all fiber-based interferometer using commercial off the shelf pigtailed telecommunication components. The compensated link shows an Allan deviation of a few 10-16 at one second and a few 10-19 at 10,000 seconds.
△ Less
Submitted 12 September, 2008; v1 submitted 11 July, 2008;
originally announced July 2008.
-
Absolute frequency measurements for hyperfine structure determination of the R(26) 62-0 transition at 501.7 nm in molecular iodine
Authors:
Andrei Goncharov,
Olivier Lopez,
Anne Amy,
Frédéric Du Burck
Abstract:
The absolute frequencies of the hyperfine components of the R(26) 62-0 transition in molecular iodine at 501.7 nm are measured for the first time with an optical clockwork based on a femtosecond laser frequency comb generator. The set-up is composed of an Ar+ laser locked to a hyperfine component of the R(26) 62-0 transition detected in a continuously pumped low-pressure cell (0.33 Pa). The dete…
▽ More
The absolute frequencies of the hyperfine components of the R(26) 62-0 transition in molecular iodine at 501.7 nm are measured for the first time with an optical clockwork based on a femtosecond laser frequency comb generator. The set-up is composed of an Ar+ laser locked to a hyperfine component of the R(26) 62-0 transition detected in a continuously pumped low-pressure cell (0.33 Pa). The detected resonances show a linewidth of 45 kHz (half-width at half-maximum). The uncertainty of the frequency measurement is estimated to be 250 Hz.
△ Less
Submitted 27 June, 2007;
originally announced June 2007.
-
Agile low phase noise radio-frequency sine wave generator applied to experiments on ultracold atoms
Authors:
Olivier Morizot,
Julien De Lapeyre De Bellair,
Fabrice Wiotte,
Olivier Lopez,
Paul-Eric Pottie,
Hélène Perrin
Abstract:
We report on the frequency performance of a low cost (~500$) radio-frequency sine wave generator, using direct digital synthesis (DDS) and a field-programmable gate array (FPGA). The output frequency of the device may be changed dynamically to any arbitrary value ranging from DC to 10 MHz without any phase slip. Sampling effects are substantially reduced by a high sample rate, up to 1 MHz, and b…
▽ More
We report on the frequency performance of a low cost (~500$) radio-frequency sine wave generator, using direct digital synthesis (DDS) and a field-programmable gate array (FPGA). The output frequency of the device may be changed dynamically to any arbitrary value ranging from DC to 10 MHz without any phase slip. Sampling effects are substantially reduced by a high sample rate, up to 1 MHz, and by a large memory length, more than 2.10^5 samples. By using a low noise external oscillator to clock the DDS, we demonstrate a phase noise as low as that of the master clock, that is at the level of -113 dB.rad^2/Hz at 1 Hz from the carrier for an output frequency of 3.75 MHz. The device is successfully used to confine an ultracold atomic cloud of rubidium 87 in a RF-based trap, and there is no extra heating from the RF source.
△ Less
Submitted 16 April, 2007;
originally announced April 2007.
-
High Resolution Frequency Standard Dissemination via Optical Fibre Metropolitan Network
Authors:
Francois Narbonneau,
Michel Lours,
Olivier Lopez,
Anne Amy-Klein,
Christophe Daussy,
Christian Chardonnet,
Sebastien Bize,
Andre Clairon,
Giorgio Santarelli
Abstract:
We present in this paper results on a new dissemination system of ultra-stable reference signal at 100 MHz on a standard fibre network. The 100 MHz signal is simply transferred by amplitude modulation of an optical carrier. Two different approaches for compensating the noise introduced by the link have been implemented. The limits of the two systems are analyzed and several solution suggested in…
▽ More
We present in this paper results on a new dissemination system of ultra-stable reference signal at 100 MHz on a standard fibre network. The 100 MHz signal is simply transferred by amplitude modulation of an optical carrier. Two different approaches for compensating the noise introduced by the link have been implemented. The limits of the two systems are analyzed and several solution suggested in order to improve the frequency stability and to further extend the distribution distance. Nevertheless, our system is a good tool for the best cold atom fountains comparison between laboratories, up to 100 km, with a relative frequency resolution of 10-14 at one second integration time and 10-17 for one day of measurement. The distribution system may be upgraded to fulfill the stringent distribution requirements for the future optical clocks.
△ Less
Submitted 15 March, 2006;
originally announced March 2006.