-
High Accuracy Determination of Rheological Properties of Drilling Fluids Using the Marsh Funnel
Authors:
Sanket Biswas,
Harshita Tiwari,
Sujata Verma,
Kamlesh Kumari
Abstract:
Efficient and safe drilling operations require precise determination of rheological properties in drilling fluids, encompassing dynamic viscosity for Newtonian fluids, and apparent viscosity, plastic viscosity, and yield point for non-Newtonian fluids. Conventional viscometers like vibrating wire, ZNN-D6, and Fann-35 offer high accuracy but are limited by cost and complexity in small-scale industr…
▽ More
Efficient and safe drilling operations require precise determination of rheological properties in drilling fluids, encompassing dynamic viscosity for Newtonian fluids, and apparent viscosity, plastic viscosity, and yield point for non-Newtonian fluids. Conventional viscometers like vibrating wire, ZNN-D6, and Fann-35 offer high accuracy but are limited by cost and complexity in small-scale industries and labs. To address this, our research presents a novel mathematical model based on the Herschel-Bulkley model, aiming to accurately characterise drilling fluids' rheological properties using the Marsh funnel as an alternative device -- an economical, operator-friendly, and power-independent equipment. Drawing inspiration from seminal works by Li et al. (2020), Sedaghat (2017), and Guria et al. (2013), this innovative framework establishes a universal inverse linear relationship between a fluid's flow factor and final discharge time. For any fluid, it utilises its density and flow factor (or final discharge time) to determine all its rheological properties. Specifically, it evaluates dynamic viscosity for Newtonian fluids, apparent viscosity, plastic viscosity, and yield point for weighted non-Newtonian fluids, and apparent viscosity for non-weighted non-Newtonian fluids, with average systematic errors (against Fann-35 measurements) of 0.39%, 3.52%, 2.17%, 18.38%, and 5.84%, respectively, surpassing the precision of alternative mathematical models found in the aforementioned literature. Furthermore, while our framework's precision in plastic viscosity and yield point assessment of non-weighted non-Newtonian fluids slightly lags behind the framework of Li et al. (2020), it outperforms the model of Sedaghat (2017). In conclusion, despite minor limitations, our proposed mathematical model holds huge promise for drilling fluid rheology in petroleum, drilling, and related industries.
△ Less
Submitted 12 August, 2023; v1 submitted 9 August, 2023;
originally announced August 2023.
-
Relative estimation of scattering noise and its utility to select radiation detector for Gamma CT scanner
Authors:
Mayank Goswami,
Kajal Kumari
Abstract:
This study investigates two unavoidable noise factors: electronic noise and radiation scattering, associated with detectors and their electronics. This study proposes a novel methodology to estimate electronic and scattering noise separately. It utilizes mathematical tools, namely, Kanpur theorem-1, standard deviation, similarity dice coefficient parameters, and experimental Computerized Tomograph…
▽ More
This study investigates two unavoidable noise factors: electronic noise and radiation scattering, associated with detectors and their electronics. This study proposes a novel methodology to estimate electronic and scattering noise separately. It utilizes mathematical tools, namely, Kanpur theorem-1, standard deviation, similarity dice coefficient parameters, and experimental Computerized Tomography technique. Four types of gamma detectors: CsI (Tl), LaBr_3 (Ce), NaI (Tl) and HPGe are used with their respective electronics. A detector having integrated circuit electronics is shown to impart significantly less (~33% less) electronic noise in data as compared to detectors with distributed electronics. Kanpur Theorem-1 signature is proposed as a scattering error estimate. An empirical expression is developed showing that scattering noise depends strongly on mass attenuation coefficients of detector crystal material and weakly on their active area. The difference between predicted and estimated relative scattering is 14.6%. The methodology presented in this study will assist the related industry in selecting the appropriate detector of optimal diameter, thickness, material composition, and hardware as per requirement.
△ Less
Submitted 15 February, 2023;
originally announced February 2023.
-
Non-volatile electrically programmable integrated photonics with a 5-bit operation
Authors:
Rui Chen,
Zhuoran Fang,
Christopher Perez,
Forrest Miller,
Khushboo Kumari,
Abhi Saxena,
Jiajiu Zheng,
Sarah J. Geiger,
Kenneth E. Goodson,
Arka Majumdar
Abstract:
Scalable programmable photonic integrated circuits (PICs) can potentially transform the current state of classical and quantum optical information processing. However, traditional means of programming, including thermo-optic, free carrier dispersion, and Pockels effect result in either large device footprints or high static energy consumptions, significantly limiting their scalability. While chalc…
▽ More
Scalable programmable photonic integrated circuits (PICs) can potentially transform the current state of classical and quantum optical information processing. However, traditional means of programming, including thermo-optic, free carrier dispersion, and Pockels effect result in either large device footprints or high static energy consumptions, significantly limiting their scalability. While chalcogenide-based non-volatile phase-change materials (PCMs) could mitigate these problems thanks to their strong index modulation and zero static power consumption, they often suffer from large absorptive loss, low cyclability, and lack of multilevel operation. Here, we report a wide-bandgap PCM antimony sulfide (Sb2S3)-clad silicon photonic platform simultaneously achieving low loss, high cyclability, and 5-bit operation. We switch Sb2S3 via an on-chip silicon PIN diode heater and demonstrate components with low insertion loss (<1.0 dB), high extinction ratio (>10 dB), and high endurance (>1,600 switching events). Remarkably, we find that Sb2S3 can be programmed into fine intermediate states by applying identical and thermally isolated pulses, providing a unique approach to controllable multilevel operation. Through dynamic pulse control, we achieve on-demand and accurate 5-bit (32 levels) operations, rendering 0.50 +- 0.16 dB contrast per step. Using this multilevel behavior, we further trim random phase error in a balanced Mach-Zehnder interferometer. Our work opens an attractive pathway toward non-volatile large-scale programmable PICs with low-loss and on-demand multi-bit operations.
△ Less
Submitted 1 January, 2023;
originally announced January 2023.
-
Do we really need to recalibrate the CT system Configuration for every experiment?
Authors:
Kajal Kumari,
Mayank Goswami
Abstract:
Different technical and physical factors may affect the image quality reconstructed using a Computed Tomography system. We have developed and designed a 2D Gamma Computed Tomography set up to study the effect of some physical parameters. One must decide the number of detectors and set CT geometry parameters or configuration like the fan-beam angle and number of rotations. Usually, geometry paramet…
▽ More
Different technical and physical factors may affect the image quality reconstructed using a Computed Tomography system. We have developed and designed a 2D Gamma Computed Tomography set up to study the effect of some physical parameters. One must decide the number of detectors and set CT geometry parameters or configuration like the fan-beam angle and number of rotations. Usually, geometry parameters are determined based on the objects size. This study shows the influence of the density distribution of same-sized phantom or objects on CT geometry parameters. Due to limited space, industrial applications may not allow a CT system to move around the object (under investigation). On-spot customization of CT system configuration may be required according to similar situations. The same problem is experienced in medical science, material science, and many other fields in which the CT system is widely used for non-destructive imaging. The number of detectors in the scanning array is one major factor that optimizes a CT system. Of course, more detectors are desired for better resolution. Changing the number of detectors requires recalibration of CT geometry. A simulated work is presented to study the influence of the density distribution of same-sized objects and the number of detectors on CT system configuration. The same is verified experimentally also. A comparison between simulated and experimental results shows a good agreement.
△ Less
Submitted 18 August, 2022;
originally announced August 2022.
-
Noise analysis, error estimates, and Gamma Radiation Measurement for limited detector computerized tomography application
Authors:
Kajal Kumari,
Mayank Goswami
Abstract:
Computed Tomography is one of the efficient and vital modalities of non-destructive techniques (NDT). Various factors influence the CT reconstruction result, including limited projection data, detector electronics optimization, background noise, detection noise, discretized nature of projection data, and many more. Radiation hardening and other aging factors that affect the operational settings ma…
▽ More
Computed Tomography is one of the efficient and vital modalities of non-destructive techniques (NDT). Various factors influence the CT reconstruction result, including limited projection data, detector electronics optimization, background noise, detection noise, discretized nature of projection data, and many more. Radiation hardening and other aging factors that affect the operational settings may require recalibration of electronics parameters. Two well-known exercises are utilized with the motivation to improve reliability and accuracy in inverse recovery. The first exercise brute-forces an optimal candidate from the set of calibration methods for minimum error in inverse recovery. The second exercise, Kanpur Theorem-1 (KT-1) examines if optimal calibration sets electronics to impart minimum noise. The mutual conformity between statistics-derived CLT and Riemann integral transform-based KT-1 is shown first time using gamma radiation measurement. The analysis shows that measurement data with normal distribution inflicts the least noise in inverse recovery.
△ Less
Submitted 16 May, 2022;
originally announced May 2022.
-
Effect of scattering and electronic noise upon selection of detectors for Gamma Computerized Tomography
Authors:
Kajal Kumari,
Snehlata Shakya,
Mayank Goswami
Abstract:
Computed tomography (CT) has become a vital tool in a variety of fields as a result of technological developments and continual improvement. High-quality CT images are desirable for image interpretation and obtaining information from CT images. A variety of things influence the CT image quality. Various research groups have investigated and attempted to improve image quality by examining noise/err…
▽ More
Computed tomography (CT) has become a vital tool in a variety of fields as a result of technological developments and continual improvement. High-quality CT images are desirable for image interpretation and obtaining information from CT images. A variety of things influence the CT image quality. Various research groups have investigated and attempted to improve image quality by examining noise/error associated with CT geometry. This study aims to select detectors for CT, which yield the least amount of noise in projection data. Three distinct gamma-ray detectors that are routinely used in CT have been compared in terms of scattering and electrical noise. The sensitivity of Kanpur Theorem-1 to scattering noise is demonstrated in this work and used to quantify the relative level of scattering noise. The detector measures the signal multiple times, and the standard deviation of the signal is used to calculate the electronic noise. It is observed that IC CsI(Tl) scintillation detector produces low electronic noise and relative scattering noise as compared to conventional electronic detectors; NaI(Tl) and HPGe.
△ Less
Submitted 25 May, 2022;
originally announced May 2022.
-
Evaluation of finite difference based asynchronous partial differential equations solver for reacting flows
Authors:
Komal Kumari,
Emmet Cleary,
Swapnil Desai,
Diego A. Donzis,
Jacqueline H. Chen,
Konduri Aditya
Abstract:
Next-generation exascale machines with extreme levels of parallelism will provide massive computing resources for large scale numerical simulations of complex physical systems at unprecedented parameter ranges. However, novel numerical methods, scalable algorithms and re-design of current state-of-the art numerical solvers are required for scaling to these machines with minimal overheads. One such…
▽ More
Next-generation exascale machines with extreme levels of parallelism will provide massive computing resources for large scale numerical simulations of complex physical systems at unprecedented parameter ranges. However, novel numerical methods, scalable algorithms and re-design of current state-of-the art numerical solvers are required for scaling to these machines with minimal overheads. One such approach for partial differential equations based solvers involves computation of spatial derivatives with possibly delayed or asynchronous data using high-order asynchrony-tolerant (AT) schemes to facilitate mitigation of communication and synchronization bottlenecks without affecting the numerical accuracy. In the present study, an effective methodology of implementing temporal discretization using a multi-stage Runge-Kutta method with AT schemes is presented. Together these schemes are used to perform asynchronous simulations of canonical reacting flow problems, demonstrated in one-dimension including auto-ignition of a premixture, premixed flame propagation and non-premixed autoignition. Simulation results show that the AT schemes incur very small numerical errors in all key quantities of interest including stiff intermediate species despite delayed data at processing element (PE) boundaries. For simulations of supersonic flows, the degraded numerical accuracy of well-known shock-resolving WENO (weighted essentially non-oscillatory) schemes when used with relaxed synchronization is also discussed. To overcome this loss of accuracy, high-order AT-WENO schemes are derived and tested on linear and non-linear equations. Finally the novel AT-WENO schemes are demonstrated in the propagation of a detonation wave with delays at PE boundaries.
△ Less
Submitted 3 April, 2022;
originally announced April 2022.
-
AI based Scintillation Detector Calibration
Authors:
Navaneeth P. R.,
Kajal Kumari,
Mayank Goswami
Abstract:
Data set generated from the scintillation detector is used to build a mathematical model based on three different algorithms: (a) Multiple Polynomial Regression (b) Support Vector Regression (c) Neural Network algorithm. Using visualizations and correlations, it is found that the Median of the data will give accurate results and average time has a major contribution in radiation measurement.
Data set generated from the scintillation detector is used to build a mathematical model based on three different algorithms: (a) Multiple Polynomial Regression (b) Support Vector Regression (c) Neural Network algorithm. Using visualizations and correlations, it is found that the Median of the data will give accurate results and average time has a major contribution in radiation measurement.
△ Less
Submitted 14 December, 2021;
originally announced December 2021.
-
Sensitivity Analysis of calibration methods and factors effecting the statistical nature of radiation measurement
Authors:
Mayank Goswami,
Kajal Kumari
Abstract:
Scintillator detectors electronics is recalibrated against the datasheet given by the manufacturer. Optimal and mutual dependent values of (a) high voltage at PMT (Photomultiplier Tube), (b) amplifier gain, (c) average time to count the radiation particles (set by operator), and (d) number of instances/sample number are estimated. Total 5: two versions of Central Limit Theorem (CLT), (3) industry…
▽ More
Scintillator detectors electronics is recalibrated against the datasheet given by the manufacturer. Optimal and mutual dependent values of (a) high voltage at PMT (Photomultiplier Tube), (b) amplifier gain, (c) average time to count the radiation particles (set by operator), and (d) number of instances/sample number are estimated. Total 5: two versions of Central Limit Theorem (CLT), (3) industry preferred Pulse Width Saturation, (4) calibration based on MPPC coupled Gamma-ray detector and (5) gross method are used. It is shown that CLT method is the most optimal method to calibrate detector and its respective electronics couple. An inverse modeling-based Computerized Tomography method is used for verification. It is shown that statistically averaging results are more accurate and precise data than mode and median, if the data is not skewed and random number of samples are used during the calibration process. It is also shown that the average time to count the radiation particle is the most important parameter affecting the optimal calibration setting for precision and accurate measurements of gamma radiation.
△ Less
Submitted 9 September, 2021;
originally announced September 2021.
-
Direct Numerical Simulations of turbulent flows using high-order Asynchrony-Tolerant schemes: accuracy and performance
Authors:
Komal Kumari,
Diego A. Donzis
Abstract:
Direct numerical simulations (DNS) are an indispensable tool for understanding the fundamental physics of turbulent flows. Because of their steep increase in computational cost with Reynolds number ($R_λ$), well-resolved DNS are realizable only on massively parallel supercomputers, even at moderate $R_λ$. However, at extreme scales, the communications and synchronizations between processing elemen…
▽ More
Direct numerical simulations (DNS) are an indispensable tool for understanding the fundamental physics of turbulent flows. Because of their steep increase in computational cost with Reynolds number ($R_λ$), well-resolved DNS are realizable only on massively parallel supercomputers, even at moderate $R_λ$. However, at extreme scales, the communications and synchronizations between processing elements (PEs) involved in current approaches become exceedingly expensive and are expected to be a major bottleneck to scalability. In order to overcome this challenge, we developed algorithms using the so-called Asynchrony-Tolerant (AT) schemes that relax communication and synchronization constraints at a mathematical level, to perform DNS of decaying and solenoidally forced compressible turbulence. Asynchrony is introduced using two approaches, one that avoids synchronizations and the other that avoids communications. These result in periodic and random delays, respectively, at PE boundaries. We show that both asynchronous algorithms accurately resolve the large-scale and small-scale motions of turbulence, including instantaneous and intermittent fields. We also show that in asynchronous simulations the communication time is a relatively smaller fraction of the total computation time, especially at large processor count, compared to standard synchronous simulations. As a consequence, we observe improved parallel scalability up to $262144$ processors for both asynchronous algorithms.
△ Less
Submitted 23 March, 2020;
originally announced March 2020.
-
A Unified Approach for Deriving Optimal Finite Differences
Authors:
Komal Kumari,
Raktim Bhattacharya,
Diego A. Donzis
Abstract:
A unified approach to derive optimal finite differences is presented which combines three critical elements for numerical performance especially for multi-scale physical problems, namely, order of accuracy, spectral resolution and stability. The resulting mathematical framework reduces to a minimization problem subjected to equality and inequality constraints. We show that the framework can provid…
▽ More
A unified approach to derive optimal finite differences is presented which combines three critical elements for numerical performance especially for multi-scale physical problems, namely, order of accuracy, spectral resolution and stability. The resulting mathematical framework reduces to a minimization problem subjected to equality and inequality constraints. We show that the framework can provide analytical results for optimal schemes and their numerical performance including, for example, the type of errors that appear for spectrally optimal schemes. By coupling the problem in this unified framework, one can effectively decouple the requirements for order of accuracy and spectral resolution, for example. Alternatively, we show how the framework exposes the tradeoffs between e.g. accuracy and stability and how this can be used to construct explicit schemes that remain stable with very large time steps. We also show how spectrally optimal schemes only bias odd-order derivatives to remain stable, at the expense of accuracy, while leaving even-order derivatives with symmetric coefficients. Schemes constructed within this framework are tested for diverse model problems with an emphasis on reproducing the physics accurately.
△ Less
Submitted 7 August, 2019;
originally announced August 2019.