Design and Construction of the MicroBooNE Detector
Authors:
MicroBooNE Collaboration,
R. Acciarri,
C. Adams,
R. An,
A. Aparicio,
S. Aponte,
J. Asaadi,
M. Auger,
N. Ayoub,
L. Bagby,
B. Baller,
R. Barger,
G. Barr,
M. Bass,
F. Bay,
K. Biery,
M. Bishai,
A. Blake,
V. Bocean,
D. Boehnlein,
V. D. Bogert,
T. Bolton,
L. Bugel,
C. Callahan,
L. Camilleri
, et al. (215 additional authors not shown)
Abstract:
This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, a…
▽ More
This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, and acceptance tests are reported.
△ Less
Submitted 17 January, 2017; v1 submitted 17 December, 2016;
originally announced December 2016.
-
Design and operation of a setup with a camera and adjustable mirror to inspect the sense-wire planes of the Time Projection Chamber inside the MicroBooNE cryostat
Authors:
Benjamin Carls,
Glenn Horton-Smith,
Catherine C. James,
Robert M. Kubinski,
Stephen Pordes,
Anne Schukraft,
Thomas Strauss
Abstract:
Detectors in particle physics, particularly when including cryogenic components, are often enclosed in vessels that do not provide any physical or visual access to the detectors themselves after installation. However, it can be desirable for experiments to visually investigate the inside of the vessel. The MicroBooNE cryostat hosts a TPC with sense-wire planes, which had to be inspected for damage…
▽ More
Detectors in particle physics, particularly when including cryogenic components, are often enclosed in vessels that do not provide any physical or visual access to the detectors themselves after installation. However, it can be desirable for experiments to visually investigate the inside of the vessel. The MicroBooNE cryostat hosts a TPC with sense-wire planes, which had to be inspected for damage such as breakage or sagging. This paper describes an approach to view the inside of the MicroBooNE cryostat with a setup of a camera and a mirror through one of its cryogenic service nozzles. The paper describes the camera and mirror chosen for the operation, the illumination, and the mechanical structure of the setup. It explains how the system was operated and demonstrates its performance.
△ Less
Submitted 26 August, 2015; v1 submitted 7 July, 2015;
originally announced July 2015.
-
The design, construction and performance of the MICE scintillating fibre trackers
Authors:
M. Ellis,
P. R. Hobson,
P. Kyberd,
J. J. Nebrensky,
A. Bross,
J. Fagan,
T. Fitzpatrick,
R. Flores,
R. Kubinski,
J. Krider,
R. Rucinski,
P. Rubinov,
C. Tolian,
T. L. Hart,
D. M. Kaplan,
W. Luebke,
B. Freemire,
M. Wojcik,
G. Barber,
D. Clark,
I. Clark,
P. J. Dornan,
A. Fish,
S. Greenwood,
R. Hare
, et al. (27 additional authors not shown)
Abstract:
Charged-particle tracking in the international Muon Ionisation Cooling Experiment (MICE) will be performed using two solenoidal spectrometers, each instrumented with a tracking detector based on 350 μm diameter scintillating fibres. The design and construction of the trackers is described along with the quality-assurance procedures, photon-detection system, readout electronics, reconstruction and…
▽ More
Charged-particle tracking in the international Muon Ionisation Cooling Experiment (MICE) will be performed using two solenoidal spectrometers, each instrumented with a tracking detector based on 350 μm diameter scintillating fibres. The design and construction of the trackers is described along with the quality-assurance procedures, photon-detection system, readout electronics, reconstruction and simulation software and the data-acquisition system. Finally, the performance of the MICE tracker, determined using cosmic rays, is presented.
△ Less
Submitted 11 July, 2010; v1 submitted 19 May, 2010;
originally announced May 2010.