Showing 1–2 of 2 results for author: Kuś, A
-
qtOCT: quantitative transmission optical coherence tomography
Authors:
Wojciech Krauze,
Martyna Mazur,
Arkadiusz Kuś
Abstract:
Transmission optical coherence tomography (OCT) enables analysis of biological specimens in vitro through detection of forward scattered light. Up to now, transmission OCT was considered as a technique that cannot directly retrieve quantitative phase and is thus a qualitative method. In this paper, we present qtOCT, a novel quantitative transmission optical coherence tomography method. Unlike exis…
▽ More
Transmission optical coherence tomography (OCT) enables analysis of biological specimens in vitro through detection of forward scattered light. Up to now, transmission OCT was considered as a technique that cannot directly retrieve quantitative phase and is thus a qualitative method. In this paper, we present qtOCT, a novel quantitative transmission optical coherence tomography method. Unlike existing approaches, qtOCT allows for a direct, easy, fast and rigorous retrieval of 2D integrated phase information from transmission full-field swept-source OCT measurements. Our method is based on coherence gating and allows user-defined temporal measurement range selection, making it potentially suitable for analyzing multiple-scattering samples. We demonstrate high consistency between qtOCT and digital holographic microscopy phase images. This approach enhances transmission OCT capabilities, positioning it as a viable alternative to quantitative phase imaging techniques.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
-
3D scattering microphantom sample to assess quantitative accuracy in tomographic phase microscopy techniques
Authors:
Wojciech Krauze,
Arkadiusz Kuś,
Michał Ziemczonok,
Max Haimowitz,
Shwetadwip Chowdhury,
Małgorzata Kujawińska
Abstract:
In this paper we present a method to robustly evaluate the quantitative accuracy of various tomographic phase microscopy (TPM) methods with a multiple scattering 3D-printed microphantom with known geometry and refractive index distribution. We demonstrate this method by fabricating a multiple-scattering phantom and comparing 3D refractive index results that are output from three TPM reconstruction…
▽ More
In this paper we present a method to robustly evaluate the quantitative accuracy of various tomographic phase microscopy (TPM) methods with a multiple scattering 3D-printed microphantom with known geometry and refractive index distribution. We demonstrate this method by fabricating a multiple-scattering phantom and comparing 3D refractive index results that are output from three TPM reconstruction methods operating with visible and near-infrared wavelengths. One of these methods assumes the sample to be weak-scattering, while the other two take multiple scattering into account. This study can be readily extended to more complex microphantoms fabricated to more closely capture scattering characteristics of real-world scattering objects, such as tissue.
△ Less
Submitted 19 August, 2022;
originally announced August 2022.